You are on page 1of 3

INDIVIDUAL PROJECT BRIEF

Reinforced Concrete Design 2 (CESB4014/ CESB423)

(Semester 1 2020 2021)

An architectural floor layout plan of a proposed 2 storey mall building is shown in attached file. The
proposed building is to be located at Lot 6065-6067 mukim Dengkil, Selangor beside the chemical
factories and near to the sea as well. The building would be constructed using reinforced concrete frame
structure. The structure has to be designed using limit state approach complying the requirements of
design code (EC2) and local authority (Malaysian Standard, MS). The required design parameters have
to be considered with proper justification. The particular data of the project for each student is different
as shown in the given table, every student must have to use their own data. Design the structure
considering the following notes.

Conceptual design stage:

(1) The construction materials would be used in the design of the structure should be selected based
on the requirements of safety and durability of structure should be considered and need to be
reported in the project.
(2) The conceptual model of structure needs to be finalized and should comply the requirements of
architect, considering stability of structure, easy construction, low cost, faster construction of
elements.
(3) Layout plans of structural elements should be finalized considering proper load path of the
structure.
(4) Should discuss the concept of optimal design of all structural elements and need to design the
elements accordingly.

Detail design stage:

(1) Once the structural model and layout plan have been finalized, the structure need to be analysed
using engineering tools (software).
(2) All elements of the structure need to be designed through manual design calculation by using
internal forces which are obtained from structural analysis software. Both ultimate limit
state and serviceability limit state must be taken care off in the design. Every student has to
design selected elements (3 elements) of slab, flat slab, beam, column and foundation with
proper structural details. The selection must be done through group discussion with proper
justification to avoid similarity/copying of design amongst the members.

1
Additional data:
Concrete RM 250/m3 for grade A and Concrete RM 300/m3 for grade B
Formwork = RM 50/m2
Steel Bar grade 500 = RM 4/kg

ASSESSMENT AND REPORTING STRUCTURE OF CORNERSTONE PROJECT

Part 1: CONCEPTUAL DESIGN OF STRUCTURAL SYSTEM ( 15 marks)

Q1. Ability to evaluate and synthesize the design solution of structural elements i.e. slabs, columns and
foundations CO2, PO2b, C6, WP1(WK5), WP2

a) Select the suitable concrete type and grade based on building functions and location of your
project. [1.5 marks]
b) Select the optimum construction method whether cast in situ or precast based on all constraint
in the project site.
[1.5 marks]
c) Evaluate the economical structural system to be adopted in the project by designing two types
of structural system for each of structural elements namely slabs, beams, columns.
[6 marks]

Q2. Ability to illustrate solutions for reinforced concrete design problems with appropriate
consideration for public health and safety, culture, society, and environment CO3, PO3c, WK5

a) Illustrate the use of safety factor for materials according to EUROCODE 2 in reinforced
concrete design. [1.5 marks]

b) Illustrate the use of safety factor for actions according to EUROCODE 2 in reinforced
concrete design.
[1.5 marks]
c) Explain the influence of culture, society and environment in reinforced concrete design.
[3 marks]

Due date and form of Due: Week 6 (15 October 2020)


submission Student are required to scan and submit their work in softcopy to my
email address Agusril@uniten.edu.my by naming the file with your
name and student Id. Ei: Agusril (CE0104XXX) _Part1

2
Part 2 DETAIL DESIGN REPORT (25 Marks)

Q3. Ability to apply CAD/ structural engineering software to analyse and design reinforced concrete
frame structure CO4, PO5a, WK6

a) Develop 3 dimensional frame structure using Tekla Structural Designer (TSD) (7 marks)
b) Produce detail drawing using Autocad and TSD software (6 Marks)

Q4. Ability to apply the concept to design reinforced concrete two way slab, flat slab, short and slender
columns, reinforced concrete foundations, design reinforced concrete retaining wall and simply
supported pre-stressed concrete beam CO1, PO1b, WK3

a) Design of 1 selected beam and compared with TSD (2 marks)


b) Design of 1 selected column (Ground Floor) and compared with TSD (2 marks)
c) Design of 1 selected slab and compared with TSD (2 marks)
d) Design of 1 Staircase (2 marks)
e) Design of 1 Pile cap with the same location with previous selected column (2 marks)
f) Serviceability/Deflection checking (for 1 beam and 1 slab) (2 marks)

Note: part II a) to e), you must use structural analysis results from TSD.

Total marks for Cornerstone project (40 marks)

Due date and form of Due: Week 13 (10 December 2020)


submission Student are required to scan and submit their work in softcopy to my
email address Agusril@uniten.edu.my by naming the file with your
name and student Id. Ei: Agusril (CE0104XXX) _Part2