Job Safety Analysis Sheet

JOB DESCRIPTION: ARC WELDING, CUTTING, GRINDING JSA Ref. No. JSA / KOC / 05
Facility: GC - Work Area / Equipment: Permit No.
Date:
PERSONAL PROTECTIVE EQUIPMENT & TOOLS: Hard Hat, Safety Shoes, Apron, Welding Hood, Safety Goggles, Hand
Gloves, Multi Gas Detector,
SEQUENCE OF
Yes /
BASIC JOB POTENTIAL HAZARDS PRECAUTIONS
No
STEPS
 Ensure the worksite is free from flammable / toxic vapor or
Presence of flammable / toxic Vapor
liquid by safe preparation (isolation, depressurizing, draining,
or Liquid
venting, flushing, purging as required)

 The entry of non – certified tools / equipment (Welding


Transformer, Generator, Mobile Plant etc) to be authorized
Fire & Explosion under Permit to Work System.
 Keep the fire extinguishers & fire hoses in ready condition.
 Keep trained fire watch as standby
Planning
Non – compliance of KOC F & S  Refer Chapter -16 KOC F& S Regulations, HSEMS
Regulations and HSE MS Procedures - Doc. No. SA.KOC.021 ‘Welding & Cutting’; Doc.
Procedures No. SA.KOC.004 “Permit to Work”.

Unintended Shutdown of Facility /


 Identify the safety override required for the work.
Equipment

 Take a Hot Work Permit and other associated permits from


Unauthorized Work
Asset Owner.
 Ensure the welding equipment (torch, cable, electrode holder,
Defective Tools transformer, generator, cable connector, plugs, sockets etc)
are free from defect and earthed as needed.
Radiation from UV / IR Rays (Flash
 Wear protective goggles.
Eye)
 Ensure proper ventilation and fume extraction equipment in
Exposure to Welding Fumes
case of welding inside an enclosure
Burns  Wear long sleeved coverall, leather apron; welder’s hood.
Cutting / Welding
Falling of Sparks / hot bids  Enclose the welding area through tarpaulin.

 Ensure the cables have proper insulation and connector as


well as termination joints are safe for the purpose.
Electric Shock
 Locate the emergency stop switch for immediate power
isolation.

 Keep Welding Generator at least 5 meters away from hot work


Transformer / Generator near the Hot
area.
Work area
 Stop the generator when not in use.
 Ensure proper wind up & housekeeping at worksite.
Windup &  The accessories (torch, cable, electrode holder) not being used
Scattered Material
Housekeeping must be disconnected from transformer / generator and stored
separately.

Additional
Hazards
(Other than indicated
above)

Name: Designation:
KOC / ID. No. Company: SKEC
JSA Done By
Controlling Team:PMC/AMEC/KOC Contract No.(If Applicable):26422
Signature: Date: