CERTIFICATE OF CALIBRATION

CERTIFICATE NO: AMCO / 1013

This certifies that the instrument below has been tested/calibrated using equipment
traceable to National/International Standards or verified by ratio type measurements
using self-calibrating techniques

Information on the calibration process and the results are produced below and given in the
accompanying sheets of this document. All Traceable documents are on File at AMCO and
may be examined on request

Customer Name : HAMTE HEAVY INDUSTRIES


Address: Al-Jubail, Kingdom of Saudi Arabia
Description: Electric Welding Machine
Manufacturer: ESAB
Model: ESAB LHF 400
Serial No: 318-212-7779
ID : NA Calibration date: 07 Sept 2017
Location: AL JUBAIL Calibration due date: 06 March 2017

The instrument was calibrated using the following reference, maintained at AMCO Instrument &
Equipment Calibration division conforming to requirements

Reference Standard Equipment Used


Description Model Certificate No Serial No Due Date
Check Master 2016003987 705-11-0170 2nd April 17
True RMS SC-160178 21180147 16 Jan 2017

Calibrated by: Approved by:

Muhammad Shabbir Mohammad Turi


Inspection Engineer Department Manager

Note: The measurement results only pertain to instrument calibrated


This certificate and the attached measurements shall not be reproduced without AMCO permission.

Address: P.O Box 70401Al-Khobar-31952. K.S.A Website: www.amco-consult.com


Ph: +966 (0) 595566007, +966 (0) 13 8907501 Email: sales@amco-consult.com
CALIBRATION RESULTS Ref No : AMCO / 1013

Customer Name : HAMTE HEAVY INDUSTRIES


Address: Al-Jubail, Kingdom of Saudi Arabia
Description: Electric Welding Machine
Manufacturer: : ESAB
Model: ESAB LHF 400 Relative Humidity48 ±5%rh
Serial No:318-212-7779 Temperature: 22 ± 2Co
ID : NA Calibration date: 07 Match 16
Location AL JUBAIL Calibration due date: 06 March 17

Performance Test Results For ELECTRIC WELDING MACHINE

DC CURRENT:

Range UUT Setting (A) Master Reading Error % Error (FS)


(A)
400 DC 100.00 102.20 2.20 0.55
150.00 152.30 2.30 1.58
201.00 204.00 3.00 1.00
250.00 25.10 4.12 1.12

Power Source – No Load Voltage Accuracy Test

Rated Measured Output Voltage


No Load Voltage Increasing Decreasing Mean
80.0 76.0 75.8 75.90

POWER SOURCE LOAD VOLTAGE ACCURACY TEST

Function Tested UUT Setting (A) Master Reading Error % Error (FS)
(A)
Load Voltage 24.00 23.95 -0.10 -0.312

OTHER TESTS RESULT


General Information about the Calibration
Calibrated on function of voltage and current Welding Process Pass
Phvsical Condition of the U U T
Power Supply Pass
Tolerance