You are on page 1of 2

1.

0 Design Check of RC Beam at R/F

1.1) Design Parameters

Concrete strength, fcu = 45 N/mm2


Steel strength, fy = fyv = 500 N/mm2
cover, c = 50 mm

B D
1.2) Design check of Beam (RB14) 500 x 1000 beam

1.2.1) Loading

Construction load, LL = 1.5 Kpa


Dead load of slab, DLs = 4.90 Kpa (thickness= 200 mm)
Dead load of beam, DLb = 12.25 KN/m
Dead load of hanger wall, DLh = 0.2*24.5*3.5 = 17.15 KN/m (thickness = 200 mm)

Based upon the Design Report Ref.: OFL4068/10/20


Point forces of lower collar on beam:

A B
Compression 827 827
Tension 516 516
Shear 36 36

Check Compression
Hence, Total critial point load, P = 2*PA = 1654 KN (where PA = 827)
Total critical shear, v = 2*vx = 72 KN (where vx = vy = 36)

1.2.2) Structural Analysis

Assuming s/s for conservative,


Span length, l = 9m
For load width, s = 1.5 m
For design loading, w = 1.4DL + 1.6LL = 55.05 KN/m

For loading acted on mid point for conservative,


M = wl^2/8 + Pl/4+ vy*e = 4315 KNm (where e = 1.25/2 = 0.625m)
V = wl/2 + P/2 = 1075 KN

1.2.3) Design Check

I) Capacity Check

Design check of beam: -

i) Check Moment

k = M/fcu*b*d^2 = 0.248 > 0.156 (d =1200-50-10-(40*3)/2) = 880 mm)


compression bar required
As' = (k-k')*fcu*bd^2/(0.87fy*(d-d') = 4422 mm2 (d' =50+10+20/2= 70 mm)

Provide Top Reinforcement: 4T40, As, pro' = 5024 > As' OK

As = 0.156*fcu*bd^2/(0.87*fy*.775d) + As' = 13585 mm2

Provide Bottom Reinforcement, 6T40 x 2 , As,pro = 15072 mm2 > As = 13585 OK


< 4%bh = 20000 OK
ii) Check Shear

v = V/bd = 2.44 N/mm2 < 0.8√ fcu OK

100 As/bd = 3.43 => vc = 0.65 N/mm2

Hence,
vc+vr< v <0.8sqrt(fcu) => =
Asv/sv(req)=(v-vc)b/(0.87fyv) = 2.06

Provide T10 @150 (D.S) => Asv/sv = 2.09 > Asv/sv (req) = 2.06 OK