You are on page 1of 15

Footing Design Calculation

Footing No. F1
Column Length (m) = 0.45
Column Width (m) = 0.45
Support Reaction (Kip) = 40.9152278 Service 182 KN
Support Reaction (Kip) = 59.3270803 Factored 263.9 KN
Bearing capacity (Kip/ft²) = 1.75
Footing Size, B (m x m) = 1.5 1.47380355 1473.80355
Footing Size, B (ft x ft) = 4.92
Footing Depth (m) = 1.5
qᵤ (kip/ft²) = 2.45088408 Upward

Assume d (m) = 0.2 T= 0.25

Assume d (in) = 7.872

Critical Perimeter, bₒ (in) = 102.336

Vᵤ₁ (Kip) = 48.186773

øVc (Kip) = 132.371779

Punching Shear Check, Vᵤ₁ < øVc = Ok

Vᵤ₂ (Kip) = 20.7644781

øVc (Kip) = 38.184167

One-way Shear Check, Vᵤ₂ < øVc = Ok

Moment, Mᵤ (Kip-in) = 214.538588

As (in²) = 0.57813399

As (min) (in²) = 1.5492096 999.488066 mm2

Consider bar size = 12 mm


Area = 113.328 mm2

Required As with c/c = 170.079069 mm C/C

Punching Shear Check Formulae: Moment Calculation Formulae:


[ Vᵤ₁ = qᵤ*(B² - bₒ²) ] [ Mᵤ = qᵤ*B*(B/2 - C/2)²/2 ]
[ Vc = 4*(√f'c)*b0*d ]
Reinforcement Calculation Formulae:
One-way Shear Check Formulae: [ As = Mu/(0.9*fy*(d-a/2)) ]
[ Vᵤ₂ = qᵤ*B*(B/2 - C/2) ] [ a = As*fy/(0.85*f'c*B) ]
[ Vc = 2*(√f'c)*B*d ] [ As (min) = 200*B*d/fy ]
Footing Design Calculation

Footing No. F2
Column Length (m) = 0.45
Column Width (m) = 0.45
Support Reaction (Kip) = 106.33463 Service 473 KN
Support Reaction (Kip) = 154.185214 Factored 685.85 KN
Bearing capacity (Kip/ft²) = 1.75
Footing Size, B (m x m) = 2.4 2.37593456 2375.93456
Footing Size, B (ft x ft) = 7.872
Footing Depth (m) = 1.5
qᵤ (kip/ft²) = 2.48812708 Upward

Assume d (m) = 0.25 T= 0.3

Assume d (in) = 9.84

Critical Perimeter, bₒ (in) = 110.208

Vᵤ₁ (Kip) = 141.068764

øVc (Kip) = 178.192779

Punching Shear Check, Vᵤ₁ < øVc = Ok

Vᵤ₂ (Kip) = 62.6377433

øVc (Kip) = 76.368334

One-way Shear Check, Vᵤ₂ < øVc = Ok

Moment, Mᵤ (Kip-in) = 1201.89302

As (in²) = 2.51779164

As (min) (in²) = 3.0984192 1998.97613 mm2

Consider bar size = 12 mm


Area = 113.328 mm2

Required As with c/c = 136.063255 mm C/C

Punching Shear Check Formulae: Moment Calculation Formulae:


[ Vᵤ₁ = qᵤ*(B² - bₒ²) ] [ Mᵤ = qᵤ*B*(B/2 - C/2)²/2 ]
[ Vc = 4*(√f'c)*b0*d ]
Reinforcement Calculation Formulae:
One-way Shear Check Formulae: [ As = Mu/(0.9*fy*(d-a/2)) ]
[ Vᵤ₂ = qᵤ*B*(B/2 - C/2) ] [ a = As*fy/(0.85*f'c*B) ]
[ Vc = 2*(√f'c)*B*d ] [ As (min) = 200*B*d/fy ]
Footing Design Calculation

Footing No. F3
Column Length (m) = 0.45
Column Width (m) = 0.45
Support Reaction (Kip) = 138.482309 Service 616 KN
Support Reaction (Kip) = 200.799349 Factored 893.2 KN
Bearing capacity (Kip/ft²) = 1.75
Footing Size, B (m x m) = 2.8 2.71140418 2711.40418
Footing Size, B (ft x ft) = 9.184
Footing Depth (m) = 1.5
qᵤ (kip/ft²) = 2.38066644 Upward

Assume d (m) = 0.3 T= 0.35

Assume d (in) = 11.808

Critical Perimeter, bₒ (in) = 118.08

Vᵤ₁ (Kip) = 186.392508

øVc (Kip) = 229.105002

Punching Shear Check, Vᵤ₁ < øVc = Ok

Vᵤ₂ (Kip) = 84.2640124

øVc (Kip) = 106.915668

One-way Shear Check, Vᵤ₂ < øVc = Ok

Moment, Mᵤ (Kip-in) = 1948.52102

As (in²) = 3.33861238

As (min) (in²) = 4.33778688 2798.56658 mm2

Consider bar size = 16 mm


Area = 201.472 mm2

Required As with c/c = 201.575193 mm C/C

Punching Shear Check Formulae: Moment Calculation Formulae:


[ Vᵤ₁ = qᵤ*(B² - bₒ²) ] [ Mᵤ = qᵤ*B*(B/2 - C/2)²/2 ]
[ Vc = 4*(√f'c)*b0*d ]
Reinforcement Calculation Formulae:
One-way Shear Check Formulae: [ As = Mu/(0.9*fy*(d-a/2)) ]
[ Vᵤ₂ = qᵤ*B*(B/2 - C/2) ] [ a = As*fy/(0.85*f'c*B) ]
[ Vc = 2*(√f'c)*B*d ] [ As (min) = 200*B*d/fy ]
Footing Design Calculation

Footing No. F3
Column Length (m) = 0.45
Column Width (m) = 0.45
Support Reaction (Kip) = 167.482663 Service 745 KN
Support Reaction (Kip) = 242.849862 Factored 1080.25 KN
Bearing capacity (Kip/ft²) = 1.75
Footing Size, B (m x m) = 3 2.98182424 2981.82424
Footing Size, B (ft x ft) = 9.84
Footing Depth (m) = 1.5
qᵤ (kip/ft²) = 2.50811626 Upward

Assume d (m) = 0.3 T= 0.35

Assume d (in) = 11.808

Critical Perimeter, bₒ (in) = 118.08

Vᵤ₁ (Kip) = 227.671745

øVc (Kip) = 229.105002

Punching Shear Check, Vᵤ₁ < øVc = Ok

Vᵤ₂ (Kip) = 103.211191

øVc (Kip) = 114.552501

One-way Shear Check, Vᵤ₂ < øVc = Ok

Moment, Mᵤ (Kip-in) = 2589.77521

As (in²) = 4.43734272

As (min) (in²) = 4.6476288 2998.4642 mm2

Consider bar size = 16 mm


Area = 201.472 mm2

Required As with c/c = 201.575193 mm C/C

Punching Shear Check Formulae: Moment Calculation Formulae:


[ Vᵤ₁ = qᵤ*(B² - bₒ²) ] [ Mᵤ = qᵤ*B*(B/2 - C/2)²/2 ]
[ Vc = 4*(√f'c)*b0*d ]
Reinforcement Calculation Formulae:
One-way Shear Check Formulae: [ As = Mu/(0.9*fy*(d-a/2)) ]
[ Vᵤ₂ = qᵤ*B*(B/2 - C/2) ] [ a = As*fy/(0.85*f'c*B) ]
[ Vc = 2*(√f'c)*B*d ] [ As (min) = 200*B*d/fy ]
Footing Design Calculation

Footing No. F3
Column Length (m) = 0.45
Column Width (m) = 0.45
Support Reaction (Kip) = 228.181078 Service 1015 KN
Support Reaction (Kip) = 330.862563 Factored 1471.75 KN
Bearing capacity (Kip/ft²) = 1.75
Footing Size, B (m x m) = 3.5 3.48046224 3480.46224
Footing Size, B (ft x ft) = 11.48
Footing Depth (m) = 1.5
qᵤ (kip/ft²) = 2.51052097 Upward

Assume d (m) = 0.4 T= 0.45

Assume d (in) = 15.744

Critical Perimeter, bₒ (in) = 133.824

Vᵤ₁ (Kip) = 311.348424

øVc (Kip) = 346.203114

Punching Shear Check, Vᵤ₁ < øVc = Ok

Vᵤ₂ (Kip) = 144.161545

øVc (Kip) = 178.192779

One-way Shear Check, Vᵤ₂ < øVc = Ok

Moment, Mᵤ (Kip-in) = 4326.5763

As (in²) = 5.43419583

As (min) (in²) = 7.2296448 4664.27764 mm2

Consider bar size = 12 mm


Area = 113.328 mm2

Required As with c/c = 85.0395347 mm C/C

Punching Shear Check Formulae: Moment Calculation Formulae:


[ Vᵤ₁ = qᵤ*(B² - bₒ²) ] [ Mᵤ = qᵤ*B*(B/2 - C/2)²/2 ]
[ Vc = 4*(√f'c)*b0*d ]
Reinforcement Calculation Formulae:
One-way Shear Check Formulae: [ As = Mu/(0.9*fy*(d-a/2)) ]
[ Vᵤ₂ = qᵤ*B*(B/2 - C/2) ] [ a = As*fy/(0.85*f'c*B) ]
[ Vc = 2*(√f'c)*B*d ] [ As (min) = 200*B*d/fy ]