Professional Documents
Culture Documents
U
H
0/
67
00
7/
01
/2
ST
O f
(Revision – R1)
r:S
tte
C o n s u lta n ts
S S T M a rin e S o lu tio n s L td
Le
th
R oom N o. 804( 7 Floor), Rose View Plaza
Bangladesh.
E-mail: sstmarines@gmail.com
IN
P roject : P7 2 1
D ate : 0 4 JULY, 2 0 1 7
D o c . N o : P7 2 1 -1 5 4 -X-R1
SIRAJ 0 4 JULY, 2 0 1 7 R1 SB
Se
Page1
X
SST MARINE SOLUTIONS LTD
U
1 INTRODUCTION
This calculation is in accordance with the requirements of RINA Rules 2016 (Pt B, Ch 10, Sec 4).
H
2 SHIP'S PARTICULARS
0/
Length O.A = 70.00 m
Length BP = 66.98 m
67
Depth MLD = 5.30 m
00
3 CALCULATION OF EQUIPMENT NUMBER
2/3
EN = ∆ + 2. h. B + 0.1A
7/
where
01
1728.58 t [ See Attachment 01 ]
B = Moulded Breadth in [ m ]
= 12.00 m
/2
h = Effective height, in m, from the summer load waterline to the top of the uppermost house
= a + Σh n
ST
= 9.70 m
a = Freeboard amidships from the summer load waterline to the upper deck, in m.
= 2.50 m
r:S
greater than B/4. Where a house having a breadth greater than B/4 is above a house with a
breadth of B/4 or less , the upper house is to be included and the lower ignored.
2
A = Area in [m ] in profile view,of the parts of the hull, superstructures and houses above the summer
load waterline which are within the length LE and also have a breadth greater than B/4.
tte
= 367.20 m
LE = Equipment Length equal to Rule Length, L without being taken neither less than 96% nor graeter
Le
= 66.98 m
Computation of h & A
l h Profile Area
h ( Effective )
Items
2
(m) (m) ( m )
(m)
IN
Se
So EN = 413.55
P721 - Equipment Number Calculation of 1200 CBM LPG CARRIER (Hull: RSL - 41~42)
Page2
X
SST MARINE SOLUTIONS LTD
U
4 SELECTING OF ANCHORING & MOORING EQUIPMENTS
H
Table 1 : For Anchor, Chain Cables
0/
Equipment
Stockless Anchor Stud link Chain cables
Number,
Diameter [mm]
67
A< EN <=B Mass per Total
Number
A B Anchor [kg] Length[m] Q1 Q2 Q3
00
Table 2 : For Towline and Mooring Ropes
7/
Equipment Recommended Towlines & Mooring Lines
A< EN <=B
Length Br. Load Length Br. Load
01
Number
A B [m] [kN] [m] [kN]
/2
Q1 = Chain Diameter Grade K1 (Ordinary quality )
ST
r:S
OR
tte
2 ) Where three anchors are provided, two are to be connected to their own chain cables and positioned
The third anchor is intended as spare and is not required for the purpose of classification.
IN
R
e
Se
P721 - Equipment Number Calculation of 1200 CBM LPG CARRIER (Hull: RSL - 41~42)
X
GHS 15.50 1200 CBM LPG CARRIER(RSL-41 & 42)
U
ATTACHMENT 01 : HYDROSTATICS DATA
H
=====================================
0/
HYDROSTATIC PROPERTIES
67
LCF Displacement Buoyancy-Ctr. Weight/ Moment/
00
Trim is per 66.98m.
7/
NOTES:
01
1) Main Hull and negative spaces are included in the calculation.
2) Draft, VCB, KML & KMT are measured relative to moulded baseline.
ST
Profile View
H
r:S
tte
Le
A
IN
R
e
Se
Se
e
R
IN
A
Le
tte
r:S
H
ST
/2
01
7/
00
67
0/
H
U
X
Shanghai, 07 July 2017
# PLANS HAS BEEN REVIEWED ON THE BASIS OF CURRENT RELATED APPLICABLE RULES (AS AVAILABLE IN
LEOSHIP). THEY ARE TO BE DULY CONSIDERED DURING ISSUANCE OF CERTIFICATES. IN CASE OF APPLICABLE
RULES MODIFICATION, ADDITIONAL REMARKS OR NEW SUBMISSION OF PLANS MAYBE NECESSARY.
# IT IS HIGHLIGHTED TO MONITOR THE PLAN APPROVAL STATUS (MISSING DOCUMENT / OPEN REMARKS)
THROUGH THE ATTENDING SURVEYOR IN CHARGE.
# SURVEY REQUIREMENTS SPECIFIED IN THE APPLICABLE ITS FOR CLASS AND STATUTORY ASPECTS SHALL BE
APPLIED AND CHECKED BY ATTENDING RINA SURVEYOR.
Yours faithfully,
RINA Services S.p.A.
GIUSEPPE ZAGARIA