You are on page 1of 2

Statement of Requirements for Roof Project

PROJECT CODE (To be filled by Clenergy):


※CUSTOMER INFORMATION
Company: BCFG-San Pedro 2 Country: Philippines
Street no.: #25 Maharlika, San Antonio, San Pedro, Laguna Tel/Telefax: +63 919 082 5449
Contact: Jun Ortiz / Jay Talavera / Rowel Braceros E-mail: jun.frontken@outlook.com
PROJECT INFORMATION
※Project name: 2MW Roof Mount Solar Project ※Project location: San Antonio, San Pedro, Laguna
※Project size: 2MWp ※Delivery date: Q2-Q3 2021
※Expected project starting date: Q3 2021 ※Expected COD date: Q3-Q4 2021
Project status: Preparing for permits Preparing for bidding Ready to start
※Target price per watt : 0.5 USD

※Trade terms: FOB CIF DDP Other


Geographical conditions
※Local latitude&longitude: 14.3849299,121.0811503 ※Wind load: 270 KPH
m/s
2
Height above sea level: 32 m ※Snow load: KN/m
cm
※Area category

Category I Category II Category III Category IV


Flat, open ground, Fences, farms, a few Suburbs, industrial Urban area, ≧15% area
without shelter constructions or scattered trees areas, forests building higher than 15m
※Corrosivity Category
C1/Very low C2/Low C3/Medium C4/High C5/Very high
Urban areas, industrial areas with
Certain deserts, Central Urban areas, coastal high pollution or substantial effect Industrial areas with very high
Arctic/Antarctica with very Rural areas, small areas with medium of chlorides, and coastal areas pollution or significant effect of
low pollution and time of town with low pollution. pollution or some effect without spray salt water or, chlorides, or coastal areas
wetness of chlorides exposure to strong effect of de- sheltered positions on coastline
icing salts.
※Regulation/Standard/Code NSCP
※PV Module
Manufacturer: Trina Solar Module Inclination (in degree) : °
Module Weight: 24 kg Module Power: 450 Wp
Module Type: Framed Frameless Module Dimension: L*W*T= 2102 * 1040 * 35 mm
Module Array: Portrait/Vertical Landscape/Horizontal

Rows Rows

Columns Columns
Number of Modules: 4469
Module arrangement (Rows*Columns*Units):

ROOF INFORMATION
Roof load limitation: psfKN/m2

Roof orientation :

※Roof type
Pitched roof Flat roof
A) Slope (in degree): ° A) Building height: m
B) Building height: m B) Ballast Penetrative fixing Other
C) Rafter spacing: m C) Approximate Area for Array : m2
D) Purline spacing: m
E) Approximate Area for Array : m2

1/2 Form No. F-RD-023 (EN) Version:V2.5


Statement of Requirements for Roof Project

PROJECT CODE (To be filled by Clenergy):


※Roof material
A) Tile roof : tile Flat tile Slate

B) Metal sheet roof (penetration Yes No )


Corrugated sheet Trapezoidal sheet Others (roof type and spacing required)
a: mm a: mm
b (height): mm b: mm
c (thickness): mm c: mm
d (insulation layer): mm d: mm
e (insulation layer): mm
f (thickness): mm

※Fixed on (roof layout required)


on metal purlin thickness: mm
on wood purlin on the crown of metal sheet
(perpendicular to water flow direction Yes No)
PRODUCTS PREFERRED
Available accessory: Rail Cap Cable Clip for Rail Cable Clip for PV module
Cable Tray Grounding Lug&Clip Joint Box Bracket
Mounting system:
I don't know

If products are not pre-determined, please try to fill in as much known information about the project in this form. For more detailed information about
Clenergy products, please contact our sales representatives.

SPECIAL REQUIREMENTS:

The items with "※" are required to provide definitely. Drawings or pictures or other project information about roof condition are preferred. Need any
help you can find us at http://www.clenergy.com.cn
REVISION RECORD(to be filled by Clenergy):
Item Date Project Code Revised Parts Content & Reason Version Requested by
1 Ground information

2 Ground information

3 Ground information

4 Ground information

5 Ground information

Requested by: Checked by: Responded by: Date:

2/2 Form No. F-RD-023 (EN) Version:V2.5

You might also like