You are on page 1of 2

Bulletin #D19 - English

Countermeasures against noise from flexible coupling


DSE9101

The following modification should be effective in solving


abnormal noise coming from the flexible coupling,
caused by wear on the fitting surface between isolation
rubber and inertia plate.

1. If the fitting hole of the inertia plate has no


wear:

a. Machine isolation rubber according to figure 1.

b. Fit the special spacer (figure 2) together with the


modified rubber (figure 1) onto the inertia plate.

c. The special spacer is available from Daihatsu.

Ordering details: Figure 1

G403420230Z ISOLATION RUBBER SPACER

Figure 2

2. If the fitting holes of the inertia plate require


rectification due to excessive wear:

a. Re-bore fitting hole of the inertia plate to


155 0 ~ +0.1mm (this is 5 mm oversize from original
diameter).

b. Machine isolation rubber according to figure 3.

c. Fit the special spacer (figure 4) together with the


modified rubber (figure 3) onto the inertia plate.

d. The special spacer is available from Daihatsu.

Ordering details:

W302850110Z ISOLATION RUBBER SPACER (4-


B) Figure 3
Figure 4

Legal Notice
Copyright 2000 by marine industrial concerns s.a..
All rights reserved. E-mail comments to Webmaster
Updated 09.11.2004