Fortress Metal Detector Interface
1. Detect – illuminates with a red LED upon detec�on.
2. LED Bar Graph – center-reading meter contains a green and red zone to visually quan�fy the signal of product,
metal, or background noise. The larger the signal the more significant the effect/contamina�on being detected.
3. Fault – flashes upon system fault.
4. LCD Display – digital screen shows system status and enables programming via menus.
5. So� Keys – used to edit menu op�ons.
6. Enter – used to confirm changes to menu op�ons.
7. Exit – cancels any changes and returns to the previous menu.
8. Menu – navigates through submenus. Refer to Sec�on 2.3 in Operator set-up manual for further details.
9. Product – indicates with a green LED whether a product is running through the Detector; a red LED represents
a high product effect reading.
10. Hard Keys – dedicated shortcut keys provide quick access to the most commonly used features.
11. Arrow Keys – used to navigate within menu op�ons, and increase/decrease values when edi�ng.
Refer to Operator Setup manual for more informa�on regarding Interface.

For technical support; 1-888-220-8737 / 416-754-2898


service@fortresstechnology.com
The purpose of Calibra�on is to “teach” the metal detector a product effect, “learn” it (it’s a good product) and
ignore it or phase it out at a par�cular “Phase” point.

To Learn a new product or re-calibrate at any


�me, simply press the <Calibrate> key two
�mes and let good product pass through the
detector (learn vibra�on if product light does
not come on by firmly pressing on detector).

metal detector
detection fault
product normal high

sensitivity
1 The 1st �me <Calibrate> key is pressed; the Setup
metal detector
fixed
display will change to “Calibrate” menu: Phase:______ dry select
detection fault
product normal high product

enter calibrate
sensitivity
2 The 2nd �me <Calibrate> key is pressed; Setup fast
the display will show “fast” learn mode: se
testlect exit
Phase:______ dry
product
Once the detector has learned the product effect (or vibra�on), “fast” will change back to “fixed”. The phase select
menu
enter calibrate
unit
number should change to a new value.
WWW.FORTRESSTECHNOLOGY.COM
NOTE: Product Light must come on for phase number to change
exit test

To check if “Calibrated” properly, background signal from the product should be monitored. select
menumetal detector unit
To return to the main menu press the ‘EXIT’ key.
WWW.FORTRESSTECHNOLOGY.COM detection
Press so� key arrow next to ‘Signal’ to reset signal and pass product through detector. product normal high

If “Calibrated” properly, (detector has “phased out” good


product), signal with good product should be under ‘60’ Product 1 Rej: 0
(20-30 typical). Metal test samples should exceed a Sens: 100 Signal: 20
signal level of ‘100’ to get a detec�on.

Signal will always display the highest number level. The processor updates this signal every second but must be reset
enter
to view the current signal level. To reset “Signal” at any �me, press so� key arrow next to signal.
NOTE: The lower the sensi�vity to pick up the sample, the be�er to minimize
exit outside noise interference.
Sensi�vity may be increased, as long as, the signal from product is under “60”.

For technical support; 1-888-220-8737 / 416-754-2898 menu


service@fortresstechnology.com WWW.FORTRESSTECHNOLOGY.COM