You are on page 1of 1

SAUDIARAMCO.

NOTES:
1. LINE SIZES TO BE DETERMINED BY VENDORS.

2. ELECTRICAL REQUIREMENTS TO BE IN ACCORDANCE


WITH 17-SAMSS-515.

3. INSTRUMENTS TO BE SELECTED IN ACCORDANCE WITH


34-SAMSS-831.
PA
4. L.O. COOLER MAY BE MANUFACTURER STANDARD IF

OF
HEAT LOAD IS 8.8 KW (30,000 BTU) OR LESS.
L

CONSENT
5. SHELL AND TUBE EXCHANGER IF SPECIFIED.

6. POSITIVE DISPLACEMENT ROTARY PUMPS HORIZONTAL


OR VERTICAL SUBMERGED.

7. SECOND ISOLATION VALVE IS ONLY REQUIRED IF PS


PT
IS LOCATED FAR FROM PROCESS.

TTEN
L
8. THE CIRCULATING SYSTEM TO BE SEPERATE

WRI
FROM MAIN SKID.

9. LOCATION OF DRAIN VALVE SHALL ENSURE


PI

THE
COMPLETE DRAINAGE OF TANK.
SEE NOTE-7
10. SAMPLING GATE VALVE IN TURBULENT FLOW AREA

THOUT
SHALL BE PROVIDED

WI NG
DRAWI
RO RO RO RO RO LEGEND
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-004
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT

S
THI
AIR FAILURE OPEN VS -VIBRATION SWITCH
BEARING
PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
(TYP.) FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR FAILURE CLOSE XS -LIMIT SWITCH
AIR LINE

FROM
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
FAILURE STEADY
TI TI TI TI H INSTRUMENT
PDI H DATA LOGGER POINT

NPUTS
ELECTRICAL LINE AOV -AIR OPERATED VALVE
FILTER PDIT
AT -ANALYZER TRANSMITTER
F-FLOW P-PRESS.
L-LEVEL T-TEMP.

I
DT -DENSITY TRANSMITTER

NED
X-MISC. A-ALARM
ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC -FLOW CONTROLLER
MOUNTED INSTR.

OBTAI
FV -FLOW CONTROL VALVE
FCV -FLOW CONTROL VALVE
BOARD MOUNTED
FG FG FG FG (SELF-ACTUATED) INSTRUMENT
FE -FLOW ELEMENT
R/G
FG -FLOW SIGHT GLASS XL STATUS LIGHTS
FHV -FLOW MANUAL CONT. VALVE R=RED, G=GREEN

BE
FHTd -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
REDUCER
FM -FLOW METER
MOTOR STATUS

PART,SHALL
NOTE-10 RO FO -RESTRICTION ORIFICE ML
PILOT LIGHT
SPECTACLE
FQI -FLOW TOTALIZER INDICATOR
PLATE-OPEN
FR -FLOW RECORDER
LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
SPECTACLE
FY -FLOW RELAY
PLATE-CLOSED
HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
TT H XA H GATE VALVE HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
TI GLOBE VALVE
LV -LEVEL CONTROL VALVE RACK MOUNTED
CHECK VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
PLUG VALVE

N
LG -LEVEL GAUGE GLASS ELECTRICAL

I
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
BALL VALVE
LI -LEVEL INDICATOR

FULL,OR
DOUBLE DISC LR -LEVEL RECORDER INSTRUMENT
GATE VALVE LS -LEVEL SWITCH AIR SUPPLY REQUIRED

LT -LEVEL TRANSMITTER
ANGLE VALVE H
NOTE-10 LTd -LEVEL TRANSDUCER HIGH LOW
ML -MOTOR STATUS LIGHT L
PRESS RELIEF
MOV -MOTOR OPERATED VALVE
VALVE NA -ANNUNCIATOR TWO PEN RECORDER
PB -PUSHBUTTON
VACUUM RELIEF

N
I
PC -PRESSURE CONTROLLER FF
VALVE FOUNDATION
PV -PRESS. CONTROL VALVE
FIELDBUS INSTRUMENT

ON
M PCV -PRESS. CONTROL VALVE
MOTOR OPERATED
VALVE (SELF ACTUATED)

REPRODUCTI
PdC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
P PISTON OPERATED PdI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
VALVE
M M PdIC -PRESSURE DIFFERENTIAL (DCS) DISTRIBUTED CONTROL
INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
CONTROL VALVE IN CONTROL ROOM
PdIS -PRESSURE DIFFERENTIAL
R/G R/G INDICATOR SWITCH
P
BALL TYPE (DCS) DISTRIBUTED CONTROL
PdT -PRESS. DIFF. TRANSMITTER
CONTROL VALVE SYSTEM, OPERATOR INACCESSIBLE
XL XL WITH POSITIONER PdTd -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
PG -PRESSURE GAGE
R/G S (DCS) DISTRIBUTED CONTROL
SOLENOID VALVE PI -PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
R/G IN FIELD

SAUDIARAMCO.NO
XL PR -PRESSURE RECORDER
VALVE NORMALLY PS -PRESSURE SWITCH
PZV PZV XL DISTRIBUTED CONTROL
CLOSED PT -PRESSURE TRANSMITTER
PX -PRESSURE POINT INTERCONNECTING LOGIC
HS HS PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
SI -SPEED INDICATOR CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
ON/OFF TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC

COOLER IBT -INVERTED BUCKET TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
PI PI STEAM TRAP
(SELF-ACTUATED) CAN BE NORMALLY
DISPLAYED ON CRT
TE -TEMP. ELEMENT
LA SEE NOTE-5 -TIGHT SHUT OFF
TSO TG -THERMOMETER LOCAL DCS OR AUXILIARY

OF
S.C. -SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
L HOA TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER

PROPERTY
(PLC) PROGRAMMABLE LOGIC
HS HS TS -TEMP. SWITCH
CONTROLLER I/O POINT
M M HOA OWS -OILY WATER SEWER TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTd -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL

REFERENCE DRAWINGS
LT
LETTER IDENTIFICATION OF LINES AD-036204

SOLE
PIPING SYMBOLS AB-036227
L
EQUIPMENT SYMBOLS AB-036305
FROM PS INSTRUMENT SYMBOLS AC-036950
L
PIPING LAYOUT INDEX

THE
PLOT PLAN
PROCESS FLOW DIAGRAM
HYDROSTATIC TEST DIAGRAM

ARE
DRAWING CONTROL FOR J.O.
INSTRUMENT INSTALLATION SCHEDULES

N
HEREINED
LG DWG. RESPONSIBILITY STANDARDS COMMITTEE:

CONTAI
VIBRATION AND LUBRICATION
REVISION VALIDATION

SEE NOTE-6 TI THIS REVISION NO. 02 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

ON
765200-0217-004

NFORMATI
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)

ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE

HJM MBA MBA


NOTE_9
02/20/17 02/20/17 02/20/17

SLOPE REV.NO. DATE REVISION DESCRIPTION

I
CHANGED 17-AMSS-015 TO 17-SAMSS-515 AND 34-AMSS-831 TO
02 2/15/17
34-SAMSS-831

THE
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
765200 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY

AND
LUBE OIL RESERVOIR DRAWING TYPE

LUBE OIL CIRCULATION SYSTEM STD

NG
PIPING & INSTRUMENT DIAGRAM

DRAWI
STD. DWG. SAUDI ARABIA

S
UNIT NO. PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THI
990 A AA-036859 001 02
Saudi Aramco 5994 ENG. (04/14)

VECTOR CADD-07