SCHEDULE OF SPECIFICATIONS
PROJECT : RENOVATION
LOCATION :
The Schedule of Specifications shall be used in conjunction with and shall be subjected to
the General Conditions of the Specifications. Both the General Conditions of the
Specifications and the Schedule of Specification shall supplement each other and shall be
known as the “Specification”. All work included under these Schedule of Specifications shall
be subjected to the General conditions of the contract accompanying these Specifications.
HEADING PAGE
A. Schedule of Concreting 3
D. Schedule of Waterproofing 4
E. Schedule of Carpentry 4
J. Schedule of Painting 6
Page 2
Proposed RENOVATION NOV2021
A. SCHEDULE OF CONCRETING
3,000 psi (27.60 Mpa) – For pedestals, columns, footings, beams, and
girders, structural (suspended) slabs, canopies, gutters, parapet walls,
bedded slabs, sidewalks, curbs, and gutters and other non-structural
elements, lean concrete.
3. Painted cement plaster finish for interior and exterior walls as shown on
plans.
All sample for all masonry finishes shall be approved by the owner or his
representative.
1. Ceramic Tile 60 x 60 – use china granite non skid tiles (verify size) on all
Toilet & Bath and verify on plans.
2. Granite Tile 60 x 60 – use ceramic glazed tiles (verify size) on the rest of
the area and verify on plans
Tiles shall be firmly secured in place. Joints shall be wall-filled, lines kept
straight and true, and finished surfaces brought to a true place. Intersection
shall be perfectly formed using corner guides. Cutting and drilling of tiles shall
be neatly done without marring the tile surface.
Page 3
Proposed RENOVATION NOV2021
5. 9mm thk. Gypsum Board – use on all interior & exterior ceiling unless
otherwise specified. Refer to RCP.
6. 9mm thk. Gypsum Board Moisture Resistance on all T&B & exterior ceiling
unless otherwise specified.
Treat all wood members with clear wood preserver. After the necessary
preparation, apply interior Primer and Sealer. Tint with tinting-colors-in-oil.
Repair surface imperfections with glazing putty. Dry overnight, sand, then
spotcoat with topcoat. For a washable flat enamel finish, use semi-gloss
enamel. Thin. Tint with tinting-colors-in-oil. Color shall be subject to
Architect’s approval.
D. SCHEDULE OF WATERPROOFING
E. SCHEDULE OF CARPENTRY
2. Kiln-dried Tanguile:
3. Tanguile, kiln-dried, for all doors jambs of interior and exterior wood doors
in direct contact with concrete.
Page 4
Proposed RENOVATION NOV2021
Page 5
Proposed RENOVATION NOV2021
5. Panel boards – Japanese made circuit breakers, molded case with locally
fabricated enclosures, Mitsubishi, Fuji or equal.
6. Rigid metal conduits – Matsushita brand of approved quality, for conduits
1 ½”
diameter or larger. Electrical metal tubing for conduits 1 ¼ diameter or
lesser.
7. Boxes, cabinets and wire gutters – to conform with National Electric Code
as to size and gauge numbers.
8. Utility and outlet boxes – locally manufactured, conforming to NEC and UL
standards.
9. Chandeliers – Owner Supplied.
All sample of lighting fixtures and diffusers shall be submitted to the Architect
for approval.
J. SCHEDULE OF PAINTING
1. Latex paint, 2-coat job, semi-gloss, for all interior concrete and masonry
plaster walls.
2. Latex paint finish for exterior concrete masonry walls as shown on plans.
3. Enamel paint, 2-coat job, and flat & semi-gloss, for plywood ceiling and
moldings as shown on plans.
4. Stain finish for all wood doors, jambs, and casing.
5. Epoxy spray finish with 2-coats antirust primer for all metal works
including all exposed steel works.
6. Antirust primer, 2-coats for all concealed steel works.
7. Painting materials shall be Boysen, Davies brand or approved equal
Prepared By: