You are on page 1of 15

Adequacy of Built-up Columns Su

INPUT
Nominal Size
Wood Species & Structural Grade
Load
Governing Load Combination
Moisture Condition
Temperature
Incision
Column Length
No. of Rows of Bolts
Bolt Diameter at Support
No. of Laminates
Connection of Laminates
Center-to-Center Spacing
Location of Lateral Supports for strong axis
Location of Lateral Supports for weak axis
Adequacy of Built-up Columns Subjected to Axial Compression Only

UT
3 x 16
ALASKA HEMLOCK No. 1
100000
D + Lr
Dry
38
No
144
0
0
4
Bolts

Full Lateral Support


None
ns Subjected to Axial Compression Only

OUTPUT
Fc
Cd
Cm
Cf
Ct
Ci
Fc*
Slenderness ratio (strong axis)
Slenderness ratio (weak axis)
Cp (strong axis)
Cp (weak axis)
fc'
Ag
An
ft (net area)
Adequate for Compression on Net Area
ft (gross area)
Adequate for Tension on Gross Area
TPUT
1100
1.25
1
1
1
1
1375
0
14.4
1
0.672309327601261
924.425325451734
152.5
152.5
655.737704918033
pression on Net Area
655.737704918033
nsion on Gross Area
Adequacy of Dimension Lumber Truss Members Subjected to

Input
Nominal Size 3 x 10
Wood Species & Structural Grade HEM-FIR No. 2
Load 6400
Governing Load Combination D + Lr
Moisture Condition Dry
Temperature 38
Incision No
Span of Truss member 10 ft
No. of Rows of Bolts 2
Bolt Diameter at Support 0.875
Center-to-Center Spacing 20 in
Location of Lateral Support None
russ Members Subjected to Axial Tension Only

Output
Ft 525
Cd 1.25
Cm 1
Cf 1.1
Ct 1
Ci 1
Ft' 721.875
Ag 23.125
An 18.4375
ft (net area) 347.118644067797
Adequate for Tension on Net Area
ft (gross area) 276.756756756757
Adequate for Tension on Gross Area

You might also like