You are on page 1of 13

p

Proposal Document

Graha Bhakti Theatre,


Budaya, Indonesia

Fire Curtain

Quote Number: 73743

Date: 28.01.22

Submitted By: Gregory Allan

Version: 001
Contents

1 TECHNICAL RESPONSE .............................................................................................. 3


1.1 SOLUTION OVERVIEW ................................................................................................................ 4
1.2 FIRE CURTAIN (BRAIL OPTION) .................................................................................................... 5
1.3 PRELIMINARIES, INSTALLATION AND LOGISTICS ........................................................................... 5
1.4 LIST OF EXCLUSIONS.................................................................................................................. 6
2 QUOTATION/BOQ ...................................................................................................... 7
3 APPENDICES .............................................................................................................. 9
1 Technical Response
1.1 Solution Overview

From studying the provided information, J&C Joel understand the requirement for the Fire
Curtain system. The proposal comprises the following in accordance with the provided
information.

The following items are proposed as per the documents above:

- Fire Curtain (brail option)

Within this document, our proposal details below.


1. A brail fire curtain which is suspended from the top just above the proscenium
opening. When the curtain opens it folds / bunches up and stores neatly above the
proscenium opening out of view from the auditorium.
The curtain is a FABRIC ONLY curtain with wall-mounted guides and lift lines, see
description below.
The approximate weight of this system is 500kg spread evenly across the full width
of the fire curtain, to be confirmed.
Normally these curtains are used where there is restricted head-height and not
enough head-height for a straight-lift safety curtain.

The brail fire curtain system is the simplest and most cost-effective system of the two
described above.
This systems utilise Zetex fabric which is rated up to 30 minutes.
Zetex fabrics are woven from highly texturized continuous filament yarns and treated with a
proprietary vermiculite-based coating. The coating allows heat to dissipate evenly across the
surface of the fabric, significantly boosting its temperature rating and abrasion resistance.
1.2 Fire Curtain (brail option)

We have quoted to supply a 18m(w) x 9.5m(h) Brail Zetex fire curtain.


The fire curtain will consist of a fire curtain winch mounted onto the stage floor. The
winch will be complete with a hydraulic damper, to aid and slow down the last part of
the travel when the curtain is released, so it has a smooth landing at the end of
travel. The Curtain Itself is a Brail system, which consists of a series of drop lines
that terminate to a bottom bar within the Zetex Fire Rated Cloth which stacks and
deploy behind the proscenium wall. The system will have fixed steel guides either
side of the framework, and a padded buffer on the bottom for a soft landing.
Emergency release cables will be provided on each side of the proscenium wall, as
well as the control panel for raising the curtain on one side.

1.3 Preliminaries, Installation and Logistics

PRELIMINARIES

We will provide full design drawings (can be in SolidWorks and/or dwg, stp and ifc format as
well as PDF but BIM design not allowed for) including GA layouts and Shop Drawings, for
which we will require detailed As-Built construction drawings from the Main Contractor.

Project Management is provided throughout the Design, Manufacturing and Installation


stages.

Training, As-Built Drawings and an O&M Manual are included.

INSTALLATION

A team of two (2) experienced J&C Joel mechanical & electrical installation engineers will
lead teams during the installation period (estimated 3 weeks).

For the test-and-commission of the Control system, the appointed Control supplier will be on
site for a period of one (1) week to provide a satisfactory system and ensure all works
correctly.

General travel expenses included.


Accommodation and local travel expenses are included.

Load test is excluded for all systems as it is expected to be performed by a local


organisation.

LOGISTICS

Standard sea-freight carriage of all materials to port only.


1.4 List of exclusions

Below is a list of exclusions as part of this bid proposal within the scope of works for the
Stage Machinery contract.

BIM design is not included in this proposal.

Materials:
- Secondary steelwork. J&C Joel will provide loading information and location requirement. It
is expected the design, supply and installation of secondary steelwork to be performed by
the Steelwork Contractor of which J&C Joel will liaise closely with.
- Electrical power & control cabling, containment, trunking and cable tray as required. J&C
Joel will provide sizing, cable types and routing advice. It is expected the design, supply and
installation of electrical cabling and containment to be performed by the Electrical Contractor
of which J&C Joel will liaise closely with.

Installation:
- Any cable installation or cabling works not included or described above is excluded.
- Any secondary steelwork works not included or described above is excluded.
- Access equipment excluded, this is expected to be provided by the Main Contractor.
- Forklift or any lifting equipment required during unloading excluded.

Logistics:
- Any and all import taxes, duties and clearance costs excluded
2 Quotation/BoQ
SUPPLEMENTARY COSTING SHEET

Originator GA Date 11.01.22


Quote Number Customer MTJ
Description Budaya Theatre - Stage trap steelwork system
Individual
Description Qty Total Cost
Cost

Brail Fire Curtain Proposal 1 £84,175 £84,175

Page Total (ex works) £84,175


3 Appendices
This drawing is the property of J&C
Joel Limited and associated
companies. It must not be copied or
the contents divulged to any third
party without prior written consent.

Rev. By Date DESCRIPTION

0 JRC 29/01/18 First Issue

Status:
A-
B-
C-

SL SR
All dimensions in mm unless otherwise stated
Do not scale
Scale N/A Paper A1
Drawn by JRC Date 29/01/18

Checked BRO Date 29/01/18

J&C Joel Limited


T: +44 (0)1422 833835 F: +44 (0)1422 835157
sales@jcjoel.com
J&C Joel Middle East
Tel: +971 (0)4 884 7801 Fax: +971 (0)4 884 7180
uaesales@jcjoel.ae

J&C Joel Hong Kong Limited


T: +852 2357 5333 F: +852 2357 4777
hksales@jcjoel.com

J&C Joel Macau Limited


T: +853 6545 1223
macausales@jcjoel.com

J&C Joel Europe


T: +44 (0)1422 833835 F: +44 (0)1422 835157
eusales@jcjoel.com

J&C Joel South Africa


T: +27 11 0835277
sasales@jcjoel.com

Project Sharjah Arts Centre


Title Fire Curtain

Rev
Drawing No 2298-GA-005 0
ID Task Task Name Duration Start Finish Jan '22 Feb '22 Mar '22 Apr '22 May '22 Jun '22 Jul '22
Mode 15 22 29 05 12 19 26 05 12 19 26 02 09 16 23 30 07 14 21 28 04 11 18 25 02 09
1 Brail Fire Curtain 110 days Mon 31/01/22 Fri 01/07/22
2 Approval 5 days Mon 31/01/22 Fri 04/02/22
3 Approval 1 day Mon 31/01/22 Mon 31/01/22
4 Approval of Fabric 1 day Fri 04/02/22 Fri 04/02/22
5 Payment Date 50% 1 day Tue 01/02/22 Tue 01/02/22
6 Design 31 days Fri 04/02/22 Fri 18/03/22
7 Receive site As-Builts 1 day Fri 04/02/22 Fri 04/02/22
8 Design 4 wks Mon 07/02/22 Fri 04/03/22
9 Approval of drawings (Client) 1 wk Mon 07/03/22 Fri 11/03/22
10 Revisions of drawings 5 days Mon 14/03/22 Fri 18/03/22
11 Procurement & Manufacturing 95 days Mon 14/02/22 Fri 24/06/22
12 Mechanical Elements (Motors/Brakes) 8 wks Mon 14/02/22 Fri 08/04/22
13 Structural Elements (frame/guide, 4 wks Mon 14/03/22 Fri 08/04/22
smoke seals)
14 Zetex Plus Cloth 4 wks Mon 30/05/22 Fri 24/06/22
15 Logistics 60 days Mon 11/04/22 Fri 01/07/22
16 Mechanical Elements (sea freight) 6 wks Mon 11/04/22 Fri 20/05/22
17 Structural Elements (sea freight) 6 wks Mon 11/04/22 Fri 20/05/22
18 Zetex Plus Cloth (air freight) 1 wk Mon 27/06/22 Fri 01/07/22

Task Inactive Summary External Tasks

Split Manual Task External Milestone

Milestone Duration-only Deadline


Project: Budaya-FIRE CURTAIN
Summary Manual Summary Rollup Progress
Date: Fri 28/01/22
Project Summary Manual Summary Manual Progress

Inactive Task Start-only

Inactive Milestone Finish-only

Page 1

You might also like