Vessel : TOIN-Tomini Infinity Report No : TOIN/PSC/2021/S3

Port : Salvador ( 12-Nov-2021 ) IMO No : 9545716

Dear Sir,

With reference to the captioned vessel inspected at Salvador - 12-Nov-2021 we acknowledge with thanks your report

received on contents of which duly noted.

With regard to the observation items made, we would like to comment as follows :

Code Action Description


Code
16 ENGINE ROOM - PROPULSION MAIN ENGINE WITH LUBE OIL LEAK
Root Cause
Immediate Cause - Sub standard Acts/Practices
2:Failure to follow Procedure / Instructions / PMS Routine
      Lube oil leak on the main engine drain gallery due to lube oil leak from No.4 unit exhaust valve
drain pipe connecting to exhaust valve actuator.
Immediate Cause - Substandard Conditions
25:Defective Tool / Equipment
      Lube oil leak on the main engine drain gallery due to lube oil leak from No.4 unit exhaust valve
drain pipe connecting to exhaust valve actuator
Basic / Root Causes - Personal Factors
6:Improper Motivation
    6.10:Improper attempt to gain attention
      Lube oil leak on the main engine drain gallery due to lube oil leak from No.4 unit exhaust valve
drain pipe connecting to exhaust valve actuator
Basic / Root Causes - Job Factors
12:Inadequate Maintenance / Inspection
    12.3:Inadequate adjustment / assembly
      Lube oil leak on the main engine drain gallery due to lube oil leak from No.4 unit exhaust valve
drain pipe connecting to exhaust valve actuator
Deficiency Actions
Corrective Action
Lube oil leak from No. 4 unit exhaust valve oil return line connecting to exhaust valve actuator was
collected over the drain gallery. Leaking pipe removed, cleaned and retightened .
Rank/Discipline : C/E, LPSQ Superitendent
Due on : 25-Nov-2021 Corrected : 12-Nov- Verified/Closed on : 15-Jan-
On 2021 2022
Preventive Action
before tightening the parts surface to be cleaned and inspected properly
Rank/Discipline : C/E, LPSQ Superitendent
Due on : Corrected : Verified/Closed on :
On
16 ENGINE ROOM - GENERATORS NO.1 & 2 WITH LUBE OIL LEAK.

Printed By : Manoj Tyagi

Printed On : 15-Feb-2022 20:51:06 Page 1 of 4


TOMINI SHIPPING
PSC INSPECTION

Code Action Description


Code
Root Cause
Immediate Cause - Sub standard Acts/Practices
2:Failure to follow Procedure / Instructions / PMS Routine
      Lube oil traces from cam case door gaskets rectified by renewing the gaskets
Immediate Cause - Substandard Conditions
25:Defective Tool / Equipment
      Lube oil traces from cam case door gaskets rectified by renewing the gaskets
Basic / Root Causes - Personal Factors
6:Improper Motivation
    6.10:Improper attempt to gain attention
      Lube oil traces from cam case door gaskets rectified by renewing the gaskets
Basic / Root Causes - Job Factors
12:Inadequate Maintenance / Inspection
    12.3:Inadequate adjustment / assembly
      Lube oil traces from cam case door gaskets rectified by renewing the gaskets
Deficiency Actions
Corrective Action
Lube oil traces from cam case door gaskets, rectified by renewing the gaskets
Rank/Discipline : C/E, LPSQ Superitendent
Due on : 25-Nov-2021 Corrected : 12-Nov- Verified/Closed on : 15-Jan-
On 2021 2022
Preventive Action
cam case door gaskets to be renewed after every inspection.
Rank/Discipline : C/E, LPSQ Superitendent
Due on : Corrected : 15-Dec- Verified/Closed on : 15-Jan-
On 2021 2022
16 ENGINE ROOM - STEERING GEAR ROOM ANGLE INDICATOR IS BROKE (STAR BOARD)
Root Cause
Immediate Cause - Sub standard Acts/Practices
2:Failure to follow Procedure / Instructions / PMS Routine
      Steering gear local rudder angle indicator scale fabicated with teflon sheet and fixed in place. 
Immediate Cause - Substandard Conditions
25:Defective Tool / Equipment
      Steering gear local rudder angle indicator scale fabicated with teflon sheet and fixed in place. 
Basic / Root Causes - Personal Factors
6:Improper Motivation
    6.10:Improper attempt to gain attention
      Steering gear local rudder angle indicator scale fabicated with teflon sheet and fixed in place. 
Basic / Root Causes - Job Factors
12:Inadequate Maintenance / Inspection
    12.7:Inadequate assessment of repair needs
      Steering gear local rudder angle indicator scale fabicated with teflon sheet and fixed in place. 
Deficiency Actions
Corrective Action
Steering gear local rudder angle indicator scale fabicated with teflon sheet and fixed in place.

Printed By : Manoj Tyagi

Printed On : 15-Feb-2022 20:51:06 Page 2 of 4


TOMINI SHIPPING
PSC INSPECTION

Code Action Description


Code
Rank/Discipline : C/E, LPSQ Superitendent
Due on : 25-Nov-2021 Corrected : 12-Nov- Verified/Closed on : 15-Jan-
On 2021 2022
Preventive Action
Defective parts to be renewed at the first opportunity.
Rank/Discipline : C/E, LPSQ Superitendent
Due on : Corrected : 15-Dec- Verified/Closed on : 15-Jan-
On 2021 2022
0 ENGINE ROOM - DECK AIR COMPRESSOR OUT OF ORDER
Root Cause
Immediate Cause - Sub standard Acts/Practices
15:Inadequate Servicing Equipment / Machinery in operation
      Deck Air Compressor is out of order due to non availability of spare V-belt. Expected to be be 
received at the next port and compressor will be made operational.
Immediate Cause - Substandard Conditions
26:Incorrect Material
      V-BELT SUPPLIED WAS NOT SUITABLE FOR USE
Basic / Root Causes - Personal Factors
6:Improper Motivation
    6.10:Improper attempt to gain attention
      Deck Air Compressor is out of order due to non availability of spare V-belt. Expected to be be 
received at the next port and compressor will be made operational.
Basic / Root Causes - Job Factors
13:Excessive Wear and Tear
    13.2:Improper decision on extension of service life
      Deck Air Compressor is out of order due to non availability of spare V-belt. Expected to be be 
received at the next port and compressor will be made operational.
Deficiency Actions
Corrective Action
deck air compressor belt renewed.
Rank/Discipline : C/E, LPSQ Superitendent
Due on : 16-Nov-2021 Corrected : 16-Nov- Verified/Closed on : 15-Jan-
On 2021 2022
Preventive Action
All Engineers instructed to keep ROB as per office advise Minimum 1 spare belt for each
equipment.
Rank/Discipline : C/E, LPSQ Superitendent
Due on : 26-Nov-2021 Corrected : 26-Nov- Verified/Closed on : 15-Jan-
On 2021 2022
16 BRIDGE - WIPERS OUT OF ORDER
Root Cause
Immediate Cause - Sub standard Acts/Practices
2:Failure to follow Procedure / Instructions / PMS Routine
      WINDOW WIPER ELECTRICAL SUPPLY DISCONNECTED FOR MAINTENANCE

Printed By : Manoj Tyagi

Printed On : 15-Feb-2022 20:51:06 Page 3 of 4


TOMINI SHIPPING
PSC INSPECTION

Code Action Description


Code
Immediate Cause - Substandard Conditions
25:Defective Tool / Equipment
      2 UNIT OF WINDOW WIPERS NOT IN OPERATION, DUE TO FAULTY CONTROLLER AND
MOTOR.
Basic / Root Causes - Personal Factors
6:Improper Motivation
    6.10:Improper attempt to gain attention
      WINDOW WIPER ELECTRICAL SUPPLY DISCONNECTED FOR MAINTENANCE
Basic / Root Causes - Job Factors
12:Inadequate Maintenance / Inspection
    12.6:Inadequate scheduling of maintenance work
      WINDOW WIPER ELECTRICAL SUPPLY DISCONNECTED FOR MAINTENANCE
Deficiency Actions
Corrective Action
Non operational bridge window wipers overahuled and made operational, tested and found in good
working condition.
Rank/Discipline : C/E, LPSQ Superitendent
Due on : 25-Nov-2021 Corrected : 19-Nov- Verified/Closed on : 15-Dec-
On 2021 2021
Preventive Action
As a practice bridge window wipers to be tried every week in order to prevent them from seizing.
Rank/Discipline : C/E, LPSQ Superitendent
Due on : 25-Nov-2021 Corrected : 19-Nov- Verified/Closed on : 15-Dec-
On 2021 2021