50 250 50

10 MM DIA DSB FOR VERTICAL 10 MM DIA DSB FOR HORIZONTAL


BARS BARS
PLUMBING SPECIFICATIONS

50
LIFTING HANDLE
1. ALLPLUMBING WORKS SHALL CONFORM TO THE NEW
250 RULES AND REGULATIONS OF THE NATIONAL PLUMBING
CODE OF THE PHILIPPINES AND LOCAL HEALTH
12 MM DIA DSB FOR CB HANDLE AUTHORITIES
2. SIZE OF PIPES SHALL BE IN CONFORMANCE WITH THE
50

CONCRETE COVER REQUIREMENTS OF THE NATIONAL PLUMBING CODE OF


THE PHILIPPINES
P CATCH BASIN PLAN 3. WATER PIPING SHALL CONSISTS 1" AND 12" uPVC PIPE .
5 5 SCALE : 1 : 20 m
4. WASTE AND SOIL PIPING SHALL CONSISTS 100 MM AND 50
MM PVC PIPE SCHEDULE 40.
5.PIPING SHALL BE CONCEALED WHENEVER POSSIBLE,
WHERE PIPE CANNOT BE CONCEALED, THY SHALL RUN
PARALLEL TO AND AS CLOSE AS POSSIBLE.
6.PIPING SHALL BE CONCEALED WHENEVER POSSIBLE,
50 250 50 CONCRETE COVER
12 MM DIA DSB FOR WHERE PIPE CANNOT BE CONCEALED, THY SHALL RUN
CB HANDLE PARALLEL TO AND AS CLOSE AS POSSIBLE.
10 MM DIA DSB FOR HORIZONTAL 7. MINIMUM OF SOIL AND WASTE PIPE SLOPE SHALL BE
50

BARS
4" CHB WITH 1/2" TWO PERCENT.
PLASTER 10 MM DIA DSB FOR VERTICAL 8. ALL PVC PIPING CONNECTIONS SHALL BE JOINED USING
350

BARS QUALIFIED PVC SOLVENT CEMENT.


9. VENT PIPES IN ROOF SPACES SHALL RUN AS CLOSE AS
50 MM DIA PVC
WASTE PIPE
POSSIBLE TO EITHER SIDE OF ROOF WITH HORIZONTAL
@ 2% SLOPE PIPING SLOPE DOWN TO STACKS WITHOUT FORMING TRAPS.
80

VERTICAL VENT PIPES MAYBE CONNECTED INTO ONE MAIN


VENT RISER ABOVE THE HIGHEST VENTED FIXTURES.
P CATCH BASIN SECTION
5 5 SCALE : 1 : 20 m

PREPARED: PROJECT: SHEET CONTENTS: APPROVED: SHEET NO.


PLUMBING SPECIFICATIONS
PROPOSED
TWO STOREY RESIDENTIAL BUILDING CATCH BASIN PLAN
MR. MAX BARANDINO P13
CATCH BASIN SECTION
13 16
LOCATION: BRGY. NARRA, CATARMAN NORTHERN SAMAR OWNER