Professional Documents
Culture Documents
3
Datos -3 m
QLL := 7.359 10
s
kg
ρG := 30.360 d pLL := 90μm 3
3 -3 m
m QHL := 1.472 10
d pLH := 90μm s
kg
ρHL := 993
3 3
m m
QG := 0.166
kg s
ρLL := 833.884
3
m
( (
K := 0.11 1.07 - 0.074 ln 1 + 0.01 P1 ))
K = 0.033
m
k := 0.033
s
(ρLL - ρG) m
Vt := k = 0.17
ρG s
m
Vv := 0.75 Vt = 0.127
s
Paso 2
t H := 5min
t S := 3min
QL := QLL + QHL
3
VH := t H QL = 2.649 10 L
3
VS := t S QL = 1.59 10 L
L = 6 LD := 4
D
Paso 3
( )
3
4 VH + VS
DT := = 1.31 m
0.6 π LD
Se utiliza este diámetro debido a que equivale a 5ft, siendo el diámetro inmediato
D := 1.524m
superior comercial al obtenido
Paso 4
2
π D 2
A := = 1.824 m
4
Paso 5
HV := 0.6096m
HV
xV := = 0.4
HH := 175cm = 1.75 m D
HLLV := 0.3048m = 0.305 m HH
xH := = 1.148
D
HLLB := 0.1524m = 0.152 m
HLLV
xLLV := = 0.2
D
HLLB
xLLB := = 0.1
D
-5
a := -4.755930 10 d := -6.358805 g := -4.916411
b := 3.924091 e := 5.668973 h := -1.801705
c := 0.174875 f := 4.018448 i := -0.145348
2 3 4
a + c xV + e xV + g xV + i xV
yV := = 0.373
2 3 4
1 + b xV + d xV + f xV + h xV
2
AV := A yV = 0.681 m
2 3 4
a + c xH + e xH + g xH + i xH
yH := = -0.286
2 3 4
1 + b xH + d xH + f xH + h xH
2
AH := A yH = -0.522 m
2 3 4
a + c xLLV + e xLLV + g xLLV + i xLLV
yLLV := = 0.142
2 3 4
1 + b xLLV + d xLLV + f xLLV + h xLLV
2 3 4
a + c xLLB + e xLLB + g xLLB + i xLLB
yLLB := = 0.052
2 3 4
1 + b xLLB + d xLLB + f xLLB + h xLLB
2
ALLV := A yLLV = 0.26 m
2
ALLB := A yLLB = 0.095 m
Paso 6
VH + VS
L := = 4.8 m
A - AV - ALLV
Paso 7
HV
ϕ := = 4.788 s
Vv
Paso 8
QG m
VVA := = 0.244
AV s
Paso 9
LMin := VVA ϕ = 1.167 m
L
Relacion := = 4.115 Cumple la condición de ser L>Lmin
LMin
Paso 10
d p := 90
- 12 2 - 20 2
K1 := 6.5185 10 d pLL = 5.279984999999999 10 m
3
-8 m
K2 := 5.28 10
2
s
VHL := K2
(ρHL - ρLL) = 6.001 10- 3 m
μLL s
Paso 11
t HL :=
(
12 HLLB + D - HV 3
= 2.133 10 s
)
VHL
Paso 12
θLL :=
( A - AV) L = 745.462 s Cumple condición de tHL>tLL, por ende, se utiliza la longitud
QLL calculada en el paso 6
Paso 13
L
R LD := = 3.15 Cumple la condición de 1.5 < L/D < 6
D
Paso 14
HH := D - HV = 0.914 m
VH 2
ANLL := ALLV + = 0.812 m
L
Paso 15
3
-6 m
K2 := 4.4 10
2
s
( ρHL - ρLL) -3m
VLL := K2 = 1.167 10
μHL s
Paso 15
4 QHL
DB1 := = 1.267 m
π VLL
HHLB := 2 DB1 = 2.535 m
Tabla Resumen
Variable Valor Unidad
Diámetro tambor 1,524 m
Longitud tambor 4,8 m
Diámetro bota 1,267 m
Altura bota 2,535 m
Temperatura tambor 310,93 K
Presión tambor 3.447.380 Pa
Caudal de Alimentación 0,175 m3/s
Caudal de salida Gas 0,166 m3/s
Caudal salida Condensado 7,36E-03 m3/s
Caudal salida Agua 1,47E-03 m3/s
216271597237 m
0.875 m