evaluation primary air Design Value Combustion Operation Range for Design

Lower heat Combustible Total air Percentage Primary air


Load point Load
value mass flow consumption primary air volume flow

% kJ/kg kg/h m³/h i.N. % m³/h i.N.

FLD 1 100% 16 18.671 128.636 70% 90.045

FLD 2 100% 11 27.173 140.264 70% 98.185

FLD 3 100% 8 37.332 144.465 70% 101.125

FLD 4 60% 8 22.399 92.535 70% 64.774

FLD 5 60% 11 16.29 89.486 70% 62.64

FLD 6 87% 16 16.29 112.232 70% 78.562

FLD G 100% 12 24.9 126.769 70% 88.738

FLD 1´ 110% 16 20.538 141.5 70% 99.05

FLD 2´ 110% 11 29.89 154.29 70% 108.003

FLD 3´ 110% 8 41.065 158.909 70% 111.237


Range for Design Design Surcharge

Percentage Primary air Temperature at Temperature Control Design


primary air volume flow air inlet primary air surcharge surcharge

% m³/h i.N. °C °C % %

75% 96.477 5% 10%

75% 105.198 average 5% 10%

75% 108.349 25°C 25°C 5% 10%

75% 69.401 fluctuation 5% 10%

75% 67.114 5°C - 60°C 5% 10%

75% 84.174 5% 10%

75% 95.077 5% 10%

75% 106.125 0% 0%

75% 115.718 0% 0%

75% 119.182 0% 0%
MAX-selection Design
Pressure
Design Volume flow Design pressure
Volume increase
flow fan
increase fan fan

m³/h i.N. mbar m³/h i.N. mbar

107.25

116.945
> 60
120.448 120.448
mbar
77.151

74.609

93.573

105.693

102.587

111.86

115.209
Comment

Note:

rate of cross over: 1,16

To consider for the air intake: -


dusty air
- max. temperature (shift air
intake)
- variations of temperature
over the year
Evaluation Secondary Air Load point FLD 1

Load % 100%

Lower heat value kJ/kg 16


Design Value Combustion
Combustible mass flow kg/h 18.671

Total air consumption m³/h i.N. 128.64

Percentage secondary air % 30%

Secondary air volume flow m³/h i.N. 38.59


Operation Range for Design
Percentage secondary air % 40%

Secondary air volume flow m³/h i.N. 51.45

Temperature at air inlet °C

Temperature secondary air °C


Design Surcharge
Control surcharge % 5%

Design surcharge % 10%

Design Volume flow Fan m³/h i.N. 59.01


MAX-selection
Design pressure increase fan mbar

Volume flow fan m³/h i.N.


Design
Pressure increase fan mbar

Comment Air intake from the boiler hous


FLD 2 FLD 3 FLD 4 FLD 5 FLD 6 FLD G FLD 1´ FLD 2´ FLD 3´

100% 100% 60% 60% 87% 100% 110% 110% 110%

11 8 8 11 16 12 16 11 8

27.173 37.332 22.399 16.29 16.29 24.9 20.538 29.89 41.065

140.26 144.47 92.54 89.49 112.23 126.77 141.50 154.29 158.91

30% 30% 30% 30% 30% 30% 30% 30% 30%

42.08 43.34 27.76 26.85 33.67 38.03 42.45 46.29 47.67

40% 35% 35% 40% 40% 40% 40% 40% 35%

56.11 50.56 32.39 35.79 44.89 50.71 56.60 61.72 55.62

average 25°C fluctuation 5°C - 60°C

40°C

5% 5% 5% 5% 5% 5% 0% 0% 0%

10% 10% 10% 10% 10% 10% 0% 0% 0%

64.35 62.66 40.14 41.05 51.49 58.16 49.53 54.00 51.65

64.35

> 90 mbar

Air intake from the boiler house: - worm, dust free air