FOREWORD
Rev. 5 N° sheets 10
June 1997
This specification has been restructured from conceptual and graphical point of
view as “Company specification”, its general revision has been performed in
accordance with CEE rules which require functional requirements evidence and
discriminating elements deletion.
In particular:
- the specification does not take into account only one type of steel, but the
minimum mechanical properties has been fixed;
–––––––––––––––––––––––––––––
Il presente documento è RISERVATO ed è di proprietà dell'AGIP. Esso non sarà mostrato a Terzi né sarà utilizzato per scopi diversi da quelli per i quali è stato inviato.
This document is CONFIDENTIAL and the sole property of AGIP. It shall neither be shown to third parties nor used for purposes other than those for which it has been sent.
00190.MAT.MEC.SDS
Rev. 5 June 1997
Sheet 3
CONTENTS
1 GENERAL
1.1 Scope
2.3 Ergonomics
2.4 Safety
2.7 Documentation
3 SUPPLEMENTARY ELEMENTS
3.1.1 Enclosures
–––––––––––––––––––––––––––––
Il presente documento è RISERVATO ed è di proprietà dell'AGIP. Esso non sarà mostrato a Terzi né sarà utilizzato per scopi diversi da quelli per i quali è stato inviato.
This document is CONFIDENTIAL and the sole property of AGIP. It shall neither be shown to third parties nor used for purposes other than those for which it has been sent.
00190.MAT.MEC.SDS
Rev. 5 June 1997
Sheet 4
1 GENERAL
1.1 SCOPE
This specification aims to defines the additional requirements to UNI code 663
for the supply of high class seamless steel pipes, to be used for the fabrication of
pressure vessels handling hydrocarbons.
This specification covers also the requirements for supply of materials to be used
in sour environment with H 2S.
–––––––––––––––––––––––––––––
Il presente documento è RISERVATO ed è di proprietà dell'AGIP. Esso non sarà mostrato a Terzi né sarà utilizzato per scopi diversi da quelli per i quali è stato inviato.
This document is CONFIDENTIAL and the sole property of AGIP. It shall neither be shown to third parties nor used for purposes other than those for which it has been sent.
00190.MAT.MEC.SDS
Rev. 5 June 1997
Sheet 5
ASME Sect. VIII Div. I Boiler & Pressure Vessel code - Pressure
Vessel
1.2.4 Legislation
–––––––––––––––––––––––––––––
Il presente documento è RISERVATO ed è di proprietà dell'AGIP. Esso non sarà mostrato a Terzi né sarà utilizzato per scopi diversi da quelli per i quali è stato inviato.
This document is CONFIDENTIAL and the sole property of AGIP. It shall neither be shown to third parties nor used for purposes other than those for which it has been sent.
00190.MAT.MEC.SDS
Rev. 5 June 1997
Sheet 6
Steel shall be ageing type resistant, it shall be killed with aluminium and should
have a fine grain structure. The residual total aluminium content shall be not less
than 0.02%.
Steel shall be worked with a process selected by Contractor; the procedure shall
be declared and approved by Company.
The materials shall be in accordance at least with the requirements specified by
UNI Code 663, relevant material Fe 35.2.
Alternative materials supposed as equivalent or better could be submitted to
Company approval; the proposal shall be justified with comments and anyway
shall satisfy the additional requirements of this specification.
Mn V + Cr + Mo Ni + Cu
CE = C + + +
6 5 15
Where,
CE = ≤ 0.45
–––––––––––––––––––––––––––––
Il presente documento è RISERVATO ed è di proprietà dell'AGIP. Esso non sarà mostrato a Terzi né sarà utilizzato per scopi diversi da quelli per i quali è stato inviato.
This document is CONFIDENTIAL and the sole property of AGIP. It shall neither be shown to third parties nor used for purposes other than those for which it has been sent.
00190.MAT.MEC.SDS
Rev. 5 June 1997
Sheet 7
Steel grade Fe 52-2, which complies with the characteristics specified by UNI
code 663, shall also give a minimum yield strength (from proportionality to
0.20% at environmental temperature) equal to:
Rp 0.2 34 Kg/mm²
When heat treatment is requested after welding, the above minimum value shall
be noticed on the sample cut from a normalised pipe and afterwards submitted to
a stress relieving at 600°C.
Heating velocity and soaking time at stress relieving temperature shall be in
compliance with ISPESL Codes, collection "S", chapter S 8.
Charpy V Impact tests are requested in accordance with UNI Code 4714 at
temperature of -20°C, on the following samples cut from pipes along
transversal direction (in derogation to what specified by UNI Code 663 chapter
7.3):
- three samples cut in such a way that each sample will have a tangential
surface to the internal surface of the pipe;
The notch on the samples shall be made orthogonal to the pipe surface. The
minimum average value requested for each three samples shall be 40 Joule (is
allowed a minimum value of 30 Joule for one sample).
Material to be used with fluids containing H 2S which can cause SSC (“Sulphide
Stress Cracking”) and HIC (“Hydrogen Induced Cracking”), shall comply with
the additional requirements of specification 05589.MAT.COR.SPC.
–––––––––––––––––––––––––––––
Il presente documento è RISERVATO ed è di proprietà dell'AGIP. Esso non sarà mostrato a Terzi né sarà utilizzato per scopi diversi da quelli per i quali è stato inviato.
This document is CONFIDENTIAL and the sole property of AGIP. It shall neither be shown to third parties nor used for purposes other than those for which it has been sent.
00190.MAT.MEC.SDS
Rev. 5 June 1997
Sheet 8
The austenitic grain average dimensions, measured in accordance with UNI Code
3245, shall be not greater than that one of reticule n. 5 allowing not more than
20% of grain corresponding to a reticule n. 4.
Moreover a check of the microstructure, which shall be consistent with the
normalised conditions, is requested. These checks shall be carried out on
longitudinal sections close to the internal surface.
2.3 Ergonomics
2.4 Safety
–––––––––––––––––––––––––––––
Il presente documento è RISERVATO ed è di proprietà dell'AGIP. Esso non sarà mostrato a Terzi né sarà utilizzato per scopi diversi da quelli per i quali è stato inviato.
This document is CONFIDENTIAL and the sole property of AGIP. It shall neither be shown to third parties nor used for purposes other than those for which it has been sent.
00190.MAT.MEC.SDS
Rev. 5 June 1997
Sheet 9
The tests to be carried out are defined in the paragraph 2.2.1 of this specification.
The pieces shall be tested one by one by ISPESL which will issue the official
certificates.
For each pipe a segment 200 mm long , with ISPESL stamp, shall be supplied
This pipe segments shall be used for possible test samples during fabrication.
An heat and check analysis for each homogeneous lot coming from the same
heat are requested.
The residual magnetism shall be checked on 10% of pipes of the same lot and
heat, and shall be not more than 20 Gauss.
–––––––––––––––––––––––––––––
Il presente documento è RISERVATO ed è di proprietà dell'AGIP. Esso non sarà mostrato a Terzi né sarà utilizzato per scopi diversi da quelli per i quali è stato inviato.
This document is CONFIDENTIAL and the sole property of AGIP. It shall neither be shown to third parties nor used for purposes other than those for which it has been sent.
00190.MAT.MEC.SDS
Rev. 5 June 1997
Sheet 10
2.7 Documentation
Testing documentation which pipes Contractor shall supply must include at least
the following information:
3 SUPPLEMENTARY ELEMENTS
3.1.1 Enclosures
–––––––––––––––––––––––––––––