Group No:2
Submitted To:
Rating:
220V/24-0-24V
100 VA
We know the following relations:
Et = 4.44*f*Bm*Ai
Here Ai = Ag * ks
1
Also Et = Te
Here T2 = 248
V2 = 48
So Te = 5.16
Assuming efficiency = 92%
VA 100
I2 = V 2 × efficiency = 48× 0.92 =2.2644 A
I2
Area of cross section of conductor = a = del 2
Here as we have measured diameter of 0.7 mm and by seeing the SWG
table, 22 number is fit so using round table conductors,
SWG 22 diameter = 0.711 mm
Enamel coating additional diameter = 0.055 mm
Total net diameter = 0.711+0.055 = 0.766mm
SWG 22 area = 0.3973 sq.mm
SWG 22 area with enamel coating = 0.460837085mm
I2 = 2.2644 A
According to formula: del2 = 2.2644/0.460837085
So del2 = 4.91366 A/sq.mm
Where:
A = 32mm
B = 95mm
C = 48mm
D = 16mm
E = 15mm
F = 15mm
Now:
Gross Area:
Measurements for thickness of lamination strip are done by all group
members separately in the manner 3,2,2 respectively by three members.
First 5 are done using normal calipers while last 2 are done using digital
one.
Measurements
1 0.4
2 0.4
3 0.4
4 0.5
5 0.5
6 0.4
7 0.4
Mean thickness: 0.42857mm
Ag = depth*A = (No. of laminations*lamination thickness)*A
= (76*0.42857)*32
= 1042.28572 sq.mm
As told that single phase shell transformer stacking factor value should be
between 0.8 and 0.9 so we would take value of 0.87
Ai = ks * Ag = 0.87*1042.28572 = 906.788576 sq.mm
B value
As Te1 = 5.16 and Te2 = 5.02 so should get mean value which is:
Temean =( Te1 + Te2 )/2 = (5.16+5.02)/2 = 5.09
1 1
B = Te∗4.44∗f ∗Ai = = 1.02465296 Tesla
5.0 9∗4.44∗50∗906.788576∗10−6
Summary
- Both Te’s are comparable.
5.16−5.02
- Difference in values : 5.02
× 100=2.78 %