You are on page 1of 11

S.No B.S.R. Ref. Particulars Qty.

Unit Rate Amount


No.

BSR Ref. Particulars Qty Unit Rate Amount


No.

B P QURA
. a Tn a m
S r Yi t o
. t . t e u
Ri n
. c t
u
Rl
e a
f r
. s

N
o
.
7
0
0
4
R.
s 0
. 0
G- SCHEDULE

– ELECTRIC WORK (INTRNAL WIRING) FOR FACULTY OF ENGINEERING.

S. Bsr Particulars Qty. Unit Rate Amount


No No. in Rs. in Rs.
1 E-020100 Wiring for light point/ fan point/exhaust fan
point/call bell point with 1.5 Sq.mm FR.
P.V.C. insulated Flexible Copper conductor
& 1.5 sq mm nominal size FR PVC
insulated unsheathed flexible copper earth
conductor 1.1 KV grade (1S.694) of
category I and approved make, in recessed
P.V.C conduit not less than 2 mm thick
including conduit fittings, switch, round
tiles, 18 SWG metal box, 6 A switch 3 mm
thick phenolic laminated sheet, zinc
plaated/brass screws, cup wahers, making
connections, testing etc. as required.
Short Point (Upto 3 Mtr.)
1.a 450 Nos. 188.5 84825
Medium Point (Upto 6 Mtr.)
1.b 650 Nos. 334 217000
Long Point (Upto 10 Mtr.)
1.c 200 Nos. 489.5 97900
2 E 20200 Wiring of twing control light point with 1.5
sq.mm nominal size FR PVC
inslatedunsheathed flexible copper
conductor 1.1 kv grade and 1.5 sq.mm
. mominal size FR PVC insulated unsheathed
flexible copper earth conductor 1.1 kv grade
(IS:694) of approved make in
surface/recessed ISI marked medium duty
PVC conduit & it’s accessories, round tile,
18 SWG M.S. box with earth terminal,
screwless cage connectors for neutral
looping in switch (Group 1)
Short point (up to 3 mtr.) 20 No. 207 4140

Medium point (up to 6 mtr.) 25 No. 375.5 9387.50

Long point (up to 10 mtr.) 15 No. 548.5 8227.50


3 E-0203000 Wiring for Three pin 5Amp. Light point
with 1.5 Sq.mm FR. P.V.C insulated
Copper conductor 1.1 K.V. Grade cable
(IS:694) of Group I and approved make, in
recessed P.V.C conduit not less than 2 mm
thick including conduit fittings,
6Amp.switch, round tiles, 18 SWG metal
box with 3 mm sunmica sheet with bakelite
base, making connections etc. as required.

2
.a On board 200 Nos. 69 13800

.b Short Point (Upto 3 Mtr.) 37 Nos. 231.5 8565.50

.c Medium Point (Upto 6 Mtr.) 25 Nos. 377 9425

4 E-040600 S& F of power plug point accessories on 18


S.W.G. metel box with P.L. sheet , 6pin
16Amp.switch & socket out let making
connection , testing etc. 285 Nos. 140 39900
5. E-040100 Supplying & drawing FR P.V.C. insulated
& unsheathed flexible copper conductor
I.S.I. Marked of 1.1kv.grade & approved
make in conduit including making
connection etc. required (Group 1)
5.a 1 x 1.5 Sq. mm 200 Rmt. 11 2200

5.b 1 x 2.5 Sq. mm 250 Rmt. 15.50 3875

5.c 2 x 2.5 Sq. mm + 1.5sq.mm. 4225 Rmt. 40.00 169000

5.d 2 x 4 Sq. mm + 2.5 sq.mm. 3200 Rmt. 62 198400

5.e 2 x 6 Sq. mm + 2.5 sq.mm. 1025 Rmt. 89 91225

5.f 1 x 10 Sq. mm 275 Rmt 55.50 15262.5


6 E-020400 Supply and fixing of following sizes of
P.V.C conduit pipe not less than 2 mm thick
in recess with cutting the wall/roof in
regular shape and size, making good the
same as required. (Group 1)
6.a 20 mm 2100 Rmt. 21 44100

6.b 25 mm 6500 Rmt. 29 188500

6.c 40 mm 500 Rmt. 64 32000


7. E-050900 P & F surface type 10mm. thick teak wood
board with varnish and ant termite treatment
including fixing gutties etc. complete .
7.a 150 x 75 mm 25 Nos. 13 325

7.b 250 x 300 mm 50 Nos. 33 1650

7.c 375 x 450 mm 20 Nos. 56 1120

3
8. E-060100 P & F 240/415 V 10 KA breaking capacity
M.C.B.s on existing board/sheets including
making connections etc. as required
(Group 2)

Single Pole M.C.B of rating 6 A to 32 A 200 Nos. 114 22800

Single Pole M.C.B of rating 40 A to 63 A 22 Nos. 212 4664

Double pole M.C.B. of rating 6A to 32 A. 25 Nos. 332 800

Double pole M.C.B. of rating 40A to 63 A. 10 Nos. 487 4870

Tripal pole M.C.B. of rating 6A to 32 A. 35 Nos. 539 18865

Tripal pole M.C.B. of rating 40A to63 A. 20 Nos. 804 16080

Tripal pole & neutral M.C.B. of rating 40A 20 Nos. 1033 20660
to63 A.
9. E-060200 P & F 240/415 Volt Isolator on the existing
board/sheet including drilling holes making
connections etc. as required (Group 2)
Double pole 63A Rating. 15 Nos. 286 4290

10. E-060500 P& F Recessed/ surface mounting heavy


duty horizontal type sheet steel distribution
board phophatised/ power painted complete
with 100a copper bus bar, shorting link,
neutral link, and din bar, conforming
making internal DB terminations with
copper lugs, testing etc. as required (Group
2)
(Double Door Three phase) 6 Nos. 1680 10080
8 way
12 way 10 Nos. 2335 23350
11. E-060700 P&F Metal clayed industrial plug top &
socket unit with pin & sleeve type contact
porcelain // bakelite base in sheet steel
enclousure (without m.c.b.) including
making connection with lugs ,testing etc.as
required (Group1)
Single phase (Three pin) 20amp 20 Nos. 629 12580
Three phase (Five pin) 30amp 25 Nos 1376 34400

12. E-071400 P&F 6 amp.surface type ceiling rose


including making connection testing etc. as
required 1300 Nos. 16 20800

13. E-071500 P&F 6 amp.bakelite batten / angle holder


including making connection testing etc. as
required. 550 Nos. 18 9900

4
14. E-51100 P&F of 3mm. PVC sheet for fan box with
help of screws , cup washer as requird 550 Nos. 9 4950

15. E-050500 P&F sheet for boxes/ frames including


making holes for switches etc. with brass
screws, washers / zinc plated nut and bolts
as required.
Bakelite sheet 4.8mm. thick 25 Sqm. 676 16900

16. E-073100 P&F following modular accessories made


out of unbreakable and fire retardant poly
carbonate with silver contacts including
making connection tasting etc. as required
(Group 2)
6A one way switch 1200 Nos. 74 88000

6A two way switch 20 Nos 86 1720

6A Bell push 50 Nos. 86 4300

16A one way switch 225 Nos. 103 23175

6A 3 pin shuttered socket. 185 Nos. 103 19055

6A 6 pin shuttered socket. 225 Nos 172 38700


.
2 pin Telephone socket 55 Nos. 97 5335

Rj -11 Telephone jack single two line 50 Nos. 80 4000

Rj -45Computer jack with shutter 100 Nos. 138 13800

T.V. coaxial socket 40 Nos. 74 2960

Five step fan regulator 400 Nos. 402 160800

Blanking plate 50 Nos. 17 850

17. E-073200 P&F following size mounting gride plates


with cover plates (Group 2)
1/2Module 100 Nos. 57 5700

3Module 225 Nos. 57 12825

4Module 100 Nos. 69 6900

5/6Module 125 Nos. 92 11500

8Module 90 Nos. 115 10350

10/12Module 50 Nos. 143 7150

16/18Module 150 Nos. 172 25800

5
18. E-073300 P&F following size hot dip galvanized M.S.
box with eathing terminal in recess /
surfaces suitable for modular accessories as
required. 100 Nos. 27 2700
1-2 Module
225 Nos. 30 6750
3Module

4Module 100 Nos. 39 3900

5/6Module 125 Nos. 68 8500

8Module 90 Nos. 79 7110

10/12Module 50 Nos. 107 5350

16/18Module 150 Nos. 135 20250

19. E-040300 Supplying and drawing PVC jacketed with


annealed bare copper inner conductor &
tinned copper conductor shielding foam PE
dielectric Coaxial cable of approved map in
existing surface or recessed conduitev /
casing capping including making
connection as required
RG-6 1200 Rmt. 17 20400
RG-11 1000 Rmt. 34 34000
20. E-040400 Supplying and drawing PVC/ Polythene
insulated & PVC sheathed unarmoured /
armoured telephone cable with 0.5mm. dia
tinned / annealed copper conductor taped &
confirming to ITD specification S/WT-
129C of approved map in existing surface
or recessed conduit / casing capping

Un armoured

1 pair 2000 Rmt. 5.50 11000

2 pair 500 Rmt. 7.50 3750

10 pair 150 Rmt. 30 4500

20 pair 200 Rmt. 56 11200

50 pair 200 Rmt. 118 23600

6
21. E-040800 P&F Krone type man distribution frame
(MDF) in the recess / surface made out of
16 SWG sheet steel box , front openable ,
having locking arrangements duly painted
with two coat of red oxide paint & two coat
of enamel paint . 1 Nos. 800 800
10 pair

20 pair 1 Nos. 1200 1200

50 pair 3 Nos. 2200 2200


22. E-71800 P&F ISI marked Flush type 2 pin telephone
socket with plug with plug top including
Making connection testing etc as required 80 Nos. 35 2800

Total 2079747.

7
Name of work :- CONSTRUCTION OF FACUILTY OF ENGINEERING AT PRATAP NAGAR
CAMPUS OF J.R.N. RAJASTHAN VIDYAPEETH , UDAIPUR.

“H” SCHEDULE
PART “1st ”

Rates are to be quoted on Roof area basis floor wise as detailed below for work to be
executed as given in technical specification of each floor .

1. STILT FLOOR ………Per sq.mt. /sq.ft.

2. GROUND FLOOR WITHOUT STILT FLOOR ………Per sq.mt. /sq.ft.

3. GROUND FLOOR WITH STILT FLOOR ………Per sq.mt. /sq.ft.

3. FIRST FLOOR ………Per sq.mt. /sq.ft.

TECHNICAL CONSULTANT REGISTRAR

Date ---------------------- Signature & seal of the tenderer

8
TECHINACL SPECIFICATIONS FOR THE WORK
THE LABOUR RATE FOR CONSTRUCTION OF FACULTY OF ENGINEERING IS INVITED WITH
MATERIAL LIKE SAND , BRICKS, STONE AND CRUSHER AGGREGATES .ALL OTHER REQUIR MATERIAL
WILL BE PROVIDED BY THE UNIVERSITY AT SITE THE WORKS WITCH ARE REQUIR TO BE CARRIED
FOR EACH FLOOR IS SPECIFICED HERE UNDER .

A STILT FLOOR --- ceiling height. 3.25mt. to 3.5mt.

1. Site clearance & levelling of ground as per requirements


1A. Earth work in excavation in foundation trenches or drains in all types of soils including
dressing of sides and ramming of bottoms, lift upto 1.5 Mtr. including taking out the
excavated soil and depositing and refilling of jhiri with watering and ramming and disposal
of surplus excavated soil as within a lead of 50 Mtr.

2. P&L cement concrete including curing compaction etc. complete using stone aggregate
nominal size 20mm. in foundation plinth, excluding the cost of shuttering, using 1:3:6 mix

3. Filling in plinth with available excavated earth& supplied if required under floors
including watering ramming consolidation and dressing complete including lead up to
50mt. And lift up to 1.5mt.

4. Random rubble dry stone kharanja under floor

5. Random rubble stone masonary for foundation and plinth in cement sand mortar 1:6 for
above 30 cm thick walls.

6. P&L in position M-20 grade of cement concrete for all RCC structural elements up to
plinth lvl. including curing, compaction, finishing with rendering in cement sand mortar 1:3
(1 cement : 3 Coarse sand) and making good the joints, excluding cost of centering and
shuttering and reinforcement .

7. P&L in position M-20 grade of cement concrete for all RCC structural elements for super
structure. including curing, compaction, finishing with rendering in cement sand mortar 1:3
(1 cement : 3 Coarse sand) and making good the joints, excluding cost of centering and
shuttering and reinforcement .for columns,pillars,posts etc.

8. P&L in position M-20 grade of cement concrete for all RCC structural elements for super
structure . including curing, compaction, finishing with rendering in cement sand mortar 1:3
(1 cement : 3 Coarse sand) and making good the joints, excluding cost of centering and
shuttering and reinforcement .for suspended floors, roofs ,landings ,staircases balconies,
sills , beams, chhajjas ,lintel , etc.

9. Centering and shuttering with plywood or steel sheets, including strutting, propping,
bracing both ways with steel telescopic prop and removal of form work for
for columns, pillars, posts , struts, balconies, sills , beams, chhajjas ,lintel
suspended floors, roofs ,landings ,staircases etc.

9
10. Fabricating steel reinforcement for RCC work including cutting, bending placing in
position and binding (including cost of binding wire) all complete

11. Brick Masonary in super structure in CM 1:6 with bricks


of class designation 75 inch.

12. Fixing of kota/ marble stone Flooring, Skirting, laid over 20mm thick base of CM 1:4 and
jointed with gray/ white cement slurry to match the shade of the slab including rubbing and
mirror polishing complete .

13. Plaster on new surface on wall in cement sand moratar 1:6 including racking of joints etc.
complete fine finished for1st storey . height form plinth level 20 mm thick
14. Plaster on new surface of ceiling in cement sand mortar 1:4 including racking of joints etc
complete fine finished 12 mm thick

15. Providing edge moulding 25mm. th. Marble / kota stone including machine polishing to
edge to give high gloss finishing for stair case tread edge .

16. Filling of sunk portion of toilet roof with earthen pots of required height including filling
voids with1:2:4 light concrete using brick bats completes leveling & dressing the surface by
Thick C.C. 1:2:4 .

17. Finishing with 25m thick cement plaster on roofs & toilet sunk portation in cm. 1:4 thick
including water proofing
compounde2% of cement used with. neat cement finishing curing etc. complete in all
Respect.(Cement will be provided by department)

18. Providing & fixing of cement Cover block of required thickness in all R.C.C. Work for
adequate cover.

19. Providing & fixing wiremesh of 26 gauge (murga jali) at the junction of All R.C.C.
work & masonry work before plaster.

10
11

You might also like