Maintenance

Node

Construction MP/SP-Platform

A50016-D1703-M1-4-7620
Construction MP/SP-Platform Maintenance
Node

f Important Notice on Product Safety


Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the
parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal injury or in prop-
erty damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply
with the applicable safety standards.

The same text in German:


Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Spannung. Einige Teile
können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverletzungen und
Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und
wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte
müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

Trademarks:
All designations used in this document can be trademarks, the use of which by third parties for their
own purposes could violate the rights of their owners.

Copyright (C) Siemens AG 2005.

Issued by the Communications Group


Hofmannstraße 51
D-81359 München

Technical modifications possible.


Technical specifications and features are binding only insofar as
they are specifically and expressly agreed upon in a written contract.

2 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Reason for Update


Summary:
Issue 4

Details:
Chapter/Section Reason for Update

chap 2, 4 New modules for the CPG-3300, IPS-3300 and


SGSN section

chap 4 module A2SC deleted

Issue History
Issue Date of issue Reason for Update
Number

1 Jun 2004 New hardware version

2 Sep 2004 Update of MP and CPG/IPS section

3 Feb 2005 New hardware configuration for CPG-3200 (large


configuration)

4 July 2005 see above

A50016-D1703-M1-4-7620 3
Construction MP/SP-Platform Maintenance
Node

4 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

This document consists of a total of 111 pages. All pages are issue 4.

Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

2 Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1 R:SSNC (Basic Rack Maximal Configuration with 1 SCE and ASN (E)) . . 11
2.2 R:SSNC (Basic Rack with up to 2 SCE and 1 ASN(H)) . . . . . . . . . . . . . . . 13
2.3 R:SSNC (ASN5 Basic Rack Maximal Configuration with SXCB) . . . . . . . . 15
2.4 R:SSNC (Extension Rack with up to 4 SCE) . . . . . . . . . . . . . . . . . . . . . . . 16
2.5 Code Numbers for R:SSNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.6 R:OEM:GGSN-C (CPG-3200) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.6.1 CPG-3200 Basic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.6.2 CPG-3200 Double Basic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.6.3 CPG-3200 Medium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.6.4 CPG-3200 Large. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.7 R:OEM:GGSN-C (CPG-3300) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.7.1 General Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.7.2 Fuse Assignment CPG-3300 Configuration . . . . . . . . . . . . . . . . . . . . . . . . 26
2.7.3 CPG-3300 Basic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.7.4 SUP2/MSFC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.7.5 48-port E/FE card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.7.6 MWAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.7.7 CPG-3300 Large. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.7.8 CPG-3300 Extra Large . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.7.9 Local Charging Gateway (LCG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
2.8 R:OEM:eGGSN-C (IPS-3300) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
2.8.1 General Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
2.8.2 Fuse Assignment IPS-3300 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . 34
2.8.3 IPS-3300 Basic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
2.8.4 16-port GE card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
2.8.5 CSM/CSG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
2.8.6 IPS-3300 Large. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
2.9 R:OEM:SGSN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
2.9.1 General Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
2.9.2 2G-SGSN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
2.9.3 3G-SGSN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
2.9.4 2G/3G-SGSN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
2.10 Code Numbers for R:OEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

3 Module Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
3.1 MPP (Main Processor Platform) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
3.1.1 F:SCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
3.1.1.1 F:SCB (module side). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
3.1.1.2 F:SCB (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
3.1.1.3 F:SCB (cabling). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
3.1.2 F:SCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.1.2.1 F:SCE (module side). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

A50016-D1703-M1-4-7620 5
Construction MP/SP-Platform Maintenance
Node

3.1.2.2 F:SCE (backplane). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52


3.1.2.3 F:SCE (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
3.1.3 F:ASN(E) (ASN40 shelf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
3.1.3.1 F:ASN(E) (module side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
3.1.3.2 F:ASN(E) (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
3.1.3.3 F:ASN(E) (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
3.1.4 F:ASN(H) (ASN20 shelf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
3.1.4.1 F:ASN(H) (module side). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
3.1.4.2 F:ASN(H) (cabling). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
3.1.5 F:SXCB (ASN5 shelf). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
3.1.5.1 F:SXCB (module side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
3.1.5.2 F:SXCB (backplane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
3.1.5.3 F:SXCB (cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
3.1.6 F:SXCB (ASN5 single shelf with AMXE and MP:OAMD). . . . . . . . . . . . . . . 71
3.2 SPP (Server Processor Platform) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
3.2.1 Normal Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
3.2.2 HD Shelf. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
3.3 OEM Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
3.3.1 AFS (Force PC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
3.3.2 HUB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
3.3.3 GPS (Radio Clock). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

4 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
4.1 Main Processor Platform (MPP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
4.1.1 ACCG (Q145) (Q1022) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.1.2 ACCG (Q1161). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
4.1.3 ALIB (Q1065) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
4.1.4 AMXE (Q1019). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
4.1.5 ASMX (Q1147). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
4.1.6 ASMG8/8 (Q1146) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
4.1.7 ASMG16/16 (Q1034) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
4.1.8 GMX:E (Q1032) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
4.1.9 LIC:1,5A (Q1013) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
4.1.10 LIC:1.5A-P (Q1125) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
4.1.11 LIC:2A (Q1014) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
4.1.12 LIC:155A (Q1018-X1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
4.1.13 LIC:TSC V2 (Q1148-X1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
4.1.14 LIC:2A-P (Q1126-X1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
4.1.15 LIC:155D-P (Q1137-X301). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.1.16 LIC:155E-P (Q1137-X401). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.1.17 LIC:155F-P (Q1137-X401) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
4.1.18 MDD (U107-X100) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
4.1.19 MDD (U2594) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
4.1.20 MOD (Q1028). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
4.1.21 MPUC (Q80-X401). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
4.1.22 MPUC (Q82-X401). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
4.1.23 MPUD (Q83-X401). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
4.1.24 MPUD (Q83-X801). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

6 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.25 MPUD (Q83-X901) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94


4.1.26 MPUD (Q208-X801) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
4.1.27 MPUD (Q208-X901) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
4.1.28 MPUD (Q202) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
4.1.29 MPUD (Q208) (Q85) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
4.1.30 MPUE (Q270-X901) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
4.1.31 MPUE (Q270-X801) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
4.1.32 MPUE (Q271-X801) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
4.1.33 MPUE (Q271-X901) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
4.1.34 MPUE (Q272) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
4.1.35 MPUE (Q274-X801) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
4.1.36 PSAG (Q6124) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
4.2 Server Processor Platform (SPP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
4.2.1 LIC:ETH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
4.2.2 LIC:STM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
4.2.3 LIC:CFR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
4.2.4 Server Processor (SP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
4.2.5 MCP (Main Control Processor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
4.2.6 PS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

A50016-D1703-M1-4-7620 7
Construction MP/SP-Platform Maintenance
Node

8 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

1 Introduction
The construction manual contains all the hardware components of a network node that
are relevant for fault clearance using maintenance and nonstandard manuals.
The construction manual is divided into the following sections:
• Racks (division, layout of fuse panel)
• Module Frames (module side)
• Modules (faceplate, displays)
Two new GGSNs (CPG-3200 and CPG-3300) based on Cisco platforms have been in-
i troduced for the Siemens GPRS and UMTS networks. The old GGSN (CPG-3000)
based on SP-platform is still supported, but only for features until GR3.1/UCR2.1. New
features are only available on GGSN (CPG-3200/CPG-3300)

A50016-D1703-M1-4-7620 9
Construction MP/SP-Platform Maintenance
Node

2 Racks
2.1 R:SSNC (Basic Rack Maximal Configuration with 1 SCE and
ASN (E))
2.2 R:SSNC (Basic Rack with up to 2 SCE and 1 ASN(H))
2.3 R:SSNC (ASN5 Basic Rack Maximal Configuration with SXCB)
2.4 R:SSNC (Extension Rack with up to 4 SCE)
2.5 Code Numbers for R:SSNC
2.6 R:OEM:GGSN-C (CPG-3200)
2.7 R:OEM:GGSN-C (CPG-3300)
2.8 R:OEM:eGGSN-C (IPS-3300)
2.9 R:OEM:SGSN
2.10 Code Numbers for R:OEM

10 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

2.1 R:SSNC (Basic Rack Maximal Configuration with 1 SCE


and ASN (E))

ON ON
OFF OFF
01 02 03 04 05 06 07 08 09 10 11 22 23 24 25 26 27 28 29 30 31 32
50

49

Fuse Panel MUT01


Fan Tray MUT02

F:SCE MUT03

IDF for F:SCE in MUT03 MUT14 on rear side

F:ASN(E) 1 MUT05

F:ASN(E) 0 MUT07

IDF for F:SCB in MUT09 MUT18 on rear side

F:SCB MUT09

Fan Box MUT10

Fig. 2.1 R:SSNC

FU MUT Connector Unit

01, 32 MUT02 X2/X1, X7/X6 Fan Tray

08 MUT03 D221P4 F:SCE - ACCG0 / AMXE0

09 MUT03 D221P4 F:SCE - MPU00, 10, 20, 30, 40, 50,


60, 70

24 MUT03 D261P4 F:SCE - ACCG1 / AMXE1

25 MUT03 D261P4 F:SCE - MPU01, 11, 21, 31, 41, 51,


61, 71

28 MUT05 C263P1 F:ASN(E) 1

29 MUT05 C263P3 F:ASN(E) 1

30 MUT05 C263P5 F:ASN(E) 1

03 MUT07 C263P1 F:ASN(E) 0

04 MUT07 C263P3 F:ASN(E) 0

05 MUT07 C263P5 F:ASN(E) 0

Tab. 2.1 Fuse Assignment R:SSNC (basic rack)

A50016-D1703-M1-4-7620 11
Construction MP/SP-Platform Maintenance
Node

FU MUT Connector Unit

02 MUT09 C179P1 F:SCB side 0

31 MUT09 C191P1 F:SCB side 1

10, 32 MUT10 X6/X7, X1/X2 FAN-BOX

49, 50 MUT01 reserved for SM:ALMC

Tab. 2.1 Fuse Assignment R:SSNC (basic rack)

12 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

2.2 R:SSNC (Basic Rack with up to 2 SCE and 1 ASN(H))

ON ON
OFF OFF
01 02 03 04 05 06 07 08 09 10 11 22 23 24 25 26 27 28 29 30 31 32
50

49

Fuse Panel MUT01


Fan Tray MUT02

F:SCE MUT03

IDF for F:SCE in MUT 03 MUT14 on rear side

F:SCE MUT05

IDF for F:SCE in MUT 05 MUT16 on rear side

F:ASN(H) MUT07

IDF for F:SCB in MUT 09 MUT18 on rear side

F:SCB MUT09

Fan Box MUT10

Fig. 2.2 R:SSNC

#SCEs Fuse Assignment Fan Tray Position

1SCE 1,2,3,4,5,10,26,28,29,31,32,49,50 MUT 02 (as in Fig. 2.2)


2SCE 1SCE + 8,9,24,25 MUT03 (MUT02 empty)

Tab. 2.2 fuse assignment used for 1 to 4 SCE configurations

FU MUT Connector Unit

01 MUT02, (07) X2/X1 Fan Tray

02 MUT09 C179P1 F:SCB side 0

03 MUT07 C263P1 F:ASN 0

04 MUT07 C263P3 F:ASN 0

05 MUT07 C263P5 F:ASN 0

08, 09, 24, 25 MUT03 D221P4/5, D261P4/5 F:SCE

28 MUT05 C263P1 F:SCE

Tab. 2.3 Fuse Assignment R:SSNC (basic rack)

A50016-D1703-M1-4-7620 13
Construction MP/SP-Platform Maintenance
Node

FU MUT Connector Unit

29 MUT05 C263P3 F:SCE

30 MUT05 C263P5 F:ASN 1

31 MUT09 C191P1 F:SCB side 1

10, 32 MUT10 X6/X7, X1/X2 Fan Box

49, 50 MUT01 reserved for SM:ALCM

Tab. 2.3 Fuse Assignment R:SSNC (basic rack)

14 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

2.3 R:SSNC (ASN5 Basic Rack Maximal Configuration with


SXCB)
ON ON
OFF OFF
01 02 03 04 05 06 07 08 09 10 11 22 23 24 25 26 27 28 29 30 31 32
50

49

Breaker Panel MUT01


Fan Tray MUT02

F:SCE MUT03

IDF for F:SCE in MUT 03 MUT14 on the back

F:SCE MUT05

IDF for F:SCE in MUT 05 MUT16 on the back

F:SCE MUT07

IDF for F:SCB in MUT 07 MUT18 on the back

F:SXCB MUT09

IDF for F:SCE in MUT 09 MUT19 on the back

Fan Box MUT10

Fig. 2.3 R:SSNC

FU MUT Unit

01 MUT02, (03, 05, 07) Fan Tray

08, 09, 24, 25 MUT03 F:SCE

04, 05, 28, 29 MUT05 F:SCE

06, 07, 26, 27 MUT07 F:SCE

02, 03, 30, 31 MUT09 F:SCE

10, 32 MUT10 Fan Box

49, 50 reserved for SM:ALCM

Tab. 2.4 Fuse Assignment R:SSNC (basic rack)

A50016-D1703-M1-4-7620 15
Construction MP/SP-Platform Maintenance
Node

2.4 R:SSNC (Extension Rack with up to 4 SCE)


ON ON
OFF OFF
01 02 03 04 05 06 07 08 09 10 11 22 23 24 25 26 27 28 29 30 31 32
50

49

Breaker Panel MUT01


Fan Tray MUT02

F:SCE MUT03

IDF for F:SCE in MUT 03 MUT14 on the back

F:SCE MUT05

IDF for F:SCE in MUT 05 MUT16 on the back

F:SCE MUT07

IDF for F:SCB in MUT 07 MUT18 on the back

F:SCE or F:SXCB MUT09

IDF for F:SCE in MUT 09 MUT19 on the back

Fan Box MUT10

Fig. 2.4 R:SSNC with up to 4SCE

#SCEs Fuse Assignment


1SCE 1,2,3,10,30,31,32,49,50
2SCE 1SCE + 6,7,26,27
3SCE 2SCE + 4,5,28,29
4SCE 3SCE + 8,9,24,25

Tab. 2.5 fuse assignment used for 1 to 4 SCE configurations

FU MUT Connector Unit

01 MUT02 X2/X1, X7/X6 Fan Tray

08 MUT03 D221P4 F:SCE - ACCG0 / AMXE0

09 MUT03 D221P4 F:SCE - MPU00, 10, 20, 30, 40, 50, 60, 70

Tab. 2.6 Fuse Assignment R:SSNC (extension rack)

16 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

FU MUT Connector Unit

24 MUT03 D261P4 F:SCE - ACCG1 / AMXE1

25 MUT03 D261P4 F:SCE - MPU01, 11, 21, 31, 41, 51, 61, 71

04 MUT05 D221P4 F:SCE - ACCG0 / AMXE0

05 MUT05 D221P4 F:SCE - MPU00, 10, 20, 30, 40, 50, 60, 70

28 MUT05 D261P4 F:SCE - ACCG1 / AMXE1

29 MUT05 D261P4 F:SCE - MPU01, 11, 21, 31, 41, 51, 61, 71

06 MUT07 D221P4 F:SCE - ACCG0 / AMXE0


07 MUT07 D221P4 F:SCE - MPU00, 10, 20, 30, 40, 50, 60, 70

26 MUT07 D261P4 F:SCE - ACCG1 / AMXE1

27 MUT07 D261P4 F:SCE - MPU01, 11, 21, 31, 41, 51, 61, 71

02 MUT09 D221P4 F:SCE - ACCG0 / AMXE0

03 MUT09 D221P4 F:SCE - MPU00, 10, 20, 30, 40, 50, 60, 70

30 MUT09 D261P4 F:SCE - ACCG1 / AMXE1


31 MUT09 D261P4 F:SCE - MPU01, 11, 21, 31, 41, 51, 61, 71

10, 32 MUT10 X6/X7, X1/X2 FAN-BOX

49, 50 reserved for SM:ALMC

Tab. 2.6 Fuse Assignment R:SSNC (extension rack)

A50016-D1703-M1-4-7620 17
Construction MP/SP-Platform Maintenance
Node

2.5 Code Numbers for R:SSNC

Designation Code Numbers Remarks

R:SSNC, 7ft S30805-C2782-X


R:SSNC, 8ft S30805-C2781-X
Breaker-Panel S30805-D2744-X1 for 7ft and 8ft
Fan-Box S32007-U102-X200
Intermediate Distri- C39324-A111-B91 1 x per F:SCE, 1 x per F:SCB
bution Frame (IDF)
Fan Tray S30807-U2620-X

F:SCE S30804-B2820-X100 With ethernet


M:LIC:2A S32006-Q1014-X1 E1-LIC
M:LIC:155A S32006-Q1018-X1 155 Mbit/s, 2 Ports, 2 x STM-1/OC-
3c el.
M:LIC2A-P S32006-Q1126-X1 E1-LIC (PCP2000 8ports)
M:LIC155D-P S32006-Q1137-X301 STM1-LIC e (PCP2000 2ports)
M:LIC155E-P S32006-Q1137-X401 STM1-LIC optical short haul
(PCP2000 2ports)
M:LIC155F-P S32006-Q1137-X501 STM1-LIC optical long haul
(PCP2000 2ports)
M:LIC:TSC S32006-Q1148-X1 (PCP2000 8ports)
M:LIC:34A-P S32006-Q1150-X1 E3-LIC (PCP2000 4ports)
M:MPUD S30813-Q202-X801 DP (1GB) Encryption/Traffic Handler
M:AMXE S32006-Q1019-X1
M:ACCG S32006-Q1161-X1

F:ASN(E) S32004-B113-X
M:GMX:E S32006-Q1032-X1
M:ASMG16/16 S32006-Q1034-X1
M:PSAG S30050-Q6124-X

F:ASN(H) S32004-B121-X
M:GMX:E S32006-Q1032-X1
M:ASMG8/8 S32006-Q1146-X1

F:SCB S30804-B2755-X With ethernet

Tab. 2.7 Code Numbers for R:SSNC

18 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Designation Code Numbers Remarks

M:FOTX S30813-Q64-X
M:LIC:2A S32006-Q1014-X1 2 Mbit/s, 8 Ports, el. E1
M:LIC2A-P S32006-Q1126-X1 E1-LIC (PCP2000 8ports)
M:MPUD S30813-Q202-X801 DP (1GB) Encryption/Traffic Handler
M:MPUE S30813-Q272-X1 DP (1GB) Encryption/Traffic Handler
M:AMXE S32006-Q1019-X1
M:ALIB S32006-Q1065-X1
M:MOD S32006-Q1028-X
M:MDD S32007-U107-X100
M:MPUD S30813-Q208-X801 SA (1GB) with F:SCB with Ethernet
Interface

F:SXCB S32004-B122-X ASN(5)


M:LIC:2A S32006-Q1014-X1 E1-LIC
M:LIC:155A S32006-Q1018-X1 155 Mbit/s, 2 Ports, 2 x STM-1/OC-
3c el.
M:LIC2A-P S32006-Q1126-X1 E1-LIC (PCP2000 8ports)
M:MPUD S30813-Q85-X801 SA (1GB)
M:MPUD S30813-Q208-X801 SA, with ethernet
M:MPUE S30813-Q272-X801 DP (1GB) Encryption/Traffic Handler
M:AMXE S32006-Q1019-X1
M:ASMX S32006-Q1147-X1
M:MOD S32006-Q1028-X
M:MDD S32007-U107-X100

Tab. 2.7 Code Numbers for R:SSNC

A50016-D1703-M1-4-7620 19
Construction MP/SP-Platform Maintenance
Node

2.6 R:OEM:GGSN-C (CPG-3200)

2.6.1 CPG-3200 Basic

ON ON
OFF OFF
01 02 03 04 05 06 07 08 09 10 11 22 23 24 25 26 27 28 29 30 31 32
50

49

Breaker Panel MUT01

Rack-Alarm Unit MUT02

CPG-3200-CGW MUT03
CPG-3200-CGW MUT04

empty MUT05
empty MUT20

empty MUT06
IDF optional MUT21

CPG-3200-TS MUT07

empty MUT08

empty MUT10
empty MUT11

CPG-3200-GGSN MUT13

CPG-3200-GGSN MUT15

Fig. 2.5 R:OEM:GGSN-C (CPG-3200 Basic)

FU MUT Unit

MUT01 Breaker Panel

29 MUT02 Rack-Alarm Unit

08,25 MUT03 CPG-3200-CGW optional

07,26 MUT04 CPG-3200-CGW optional

MUT05 empty

MUT20 empty

MUT06 empty

Tab. 2.8 Fuse Assignment CPG-3200 Basic Configuration

20 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

FU MUT Unit

MUT21 IDF optional

04 MUT07 CPG-3200-TS optional

MUT08 empty

MUT10 empty

MUT11 empty

MUT13 empty

01,32 MUT15 CPG-3200-GGSN

Tab. 2.8 Fuse Assignment CPG-3200 Basic Configuration

2.6.2 CPG-3200 Double Basic

ON ON
OFF OFF
01 02 03 04 05 06 07 08 09 10 11 22 23 24 25 26 27 28 29 30 31 32
50

49

Breaker Panel MUT01

Rack-Alarm Unit MUT02

CPG-3200-CGW MUT03

CPG-3200-CGW MUT04

empty MUT05

IDF optional MUT20

empty MUT06

IDF optional MUT21

CPG-3200-TS MUT07

empty MUT08
empty MUT10

empty MUT11

CPG-3200-GGSN MUT13

CPG-3200-GGSN MUT15

Fig. 2.6 R:OEM:GGSN-C (CPG-3200 Double Basic)

A50016-D1703-M1-4-7620 21
Construction MP/SP-Platform Maintenance
Node

FU MUT Unit

MUT01 Breaker Panel

29 MUT02 Rack-Alarm Unit

08,25 MUT03 CPG-3200-CGW optional

07,26 MUT04 CPG-3200-CGW optional

MUT05 empty

MUT20 IDF optional

MUT06 empty
MUT21 IDF optional

04 MUT07 CPG-3200-TS optional

MUT08 empty

MUT10 empty

MUT11 empty
02,31 MUT13 CPG-3200-GGSN

01,32 MUT15 CPG-3200-GGSN

Tab. 2.9 Fuse Assignment CPG-3200 Double Basic Configuration

22 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

2.6.3 CPG-3200 Medium


ON ON
OFF OFF
01 02 03 04 05 06 07 08 09 10 11 22 23 24 25 26 27 28 29 30 31 32
50

49

Breaker Panel MUT01

Rack-Alarm Unit MUT02

CPG-3200-CGW MUT03

CPG-3200-CGW MUT04

CPG-3200-SLB MUT05

IDF optional MUT20

CPG-3200-SLB MUT06

IDF optional MUT21

CPG-3200-TS MUT07

CPG-3200-Switch MUT08
CPG-3200-Switch MUT10

empty MUT11

CPG-3200-GGSN MUT13

CPG-3200-GGSN MUT15

Fig. 2.7 R:OEM:GGSN-C (CPG-3200 Medium)

FU MUT Unit

MUT01 Breaker Panel

29 MUT02 Rack-Alarm Unit

08,25 MUT03 CPG-3200-CGW optional

07,26 MUT04 CPG-3200-CGW optional

06,27 MUT05 CPG-3200-SLB

MUT20 IDF optional

05,28 MUT06 CPG-3200-SLB

MUT21 IDF optional

Tab. 2.10 Fuse Assignment CPG-3200 Medium Configuration

A50016-D1703-M1-4-7620 23
Construction MP/SP-Platform Maintenance
Node

FU MUT Unit

04 MUT07 CPG-3200-TS optional

25F,08F MUT08 CPG-3200-SWITCH

26F,07F MUT10 CPG-3200-SWITCH

MUT11 empty

02,31 MUT13 CPG-3200-GGSN

01,32 MUT15 CPG-3200-GGSN

Tab. 2.10 Fuse Assignment CPG-3200 Medium Configuration

F stands for Front cabling, double assignment


i
F

2.6.4 CPG-3200 Large


ON ON
OFF OFF
01 02 03 04 05 06 07 08 09 10 11 22 23 24 25 26 27 28 29 30 31 32
50

49

Breaker Panel MUT01

Rack-Alarm Unit MUT02

CPG-3200-CGW MUT03

CPG-3200-CGW MUT04

CPG-3200-SLB MUT05

IDF optional MUT20

CPG-3200-SLB MUT06

IDF optional MUT21

CPG-3200-TS MUT07

CPG-3200-Switch MUT08
CPG-3200-Switch MUT10

CPG-3200-GGSN MUT11

CPG-3200-GGSN MUT13

CPG-3200-GGSN MUT15

Fig. 2.8 R:OEM:GGSN-C (CPG-3200 Large)

24 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

FU MUT Unit

MUT01 Breaker Panel

29 MUT02 Rack-Alarm Unit

08,25 MUT03 CPG-3200-CGW

07,26 MUT04 CPG-3200-CGW

06,27 MUT05 CPG-3200-SLB

MUT20 IDF optional

05,28 MUT06 CPG-3200-SLB


MUT21 IDF optional

04 MUT07 CPG-3200-TS

25F,08F MUT08 CPG-3200-Switch

26F,07F MUT10 CPG-3200-Switch

03,30 MUT11 CPG-3200-GGSN


02,31 MUT13 CPG-3200-GGSN

01,32 MUT15 CPG-3200-GGSN

Tab. 2.11 Fuse Assignment CPG-3200 Large Configuration

2.7 R:OEM:GGSN-C (CPG-3300)

2.7.1 General Layout


Four configurations are possible for the CPG-3300. A basic configuration, a medium
configuration, a large configuration and an extra large configuration. The difference be-
tween these configurations is the number of MWAM (Mobile Wireless Access Module)
cards and 48-port (fast) ethernet cards. The terminal server and the LAN-switch catalyst
are both optional. In the basic configuration there is no board redundancy. The other
configurations contain redundant SUP2- and 48-Port E/FE cards. An option for the
GGSN is the Local Charging Gateway (LCG).

A50016-D1703-M1-4-7620 25
Construction MP/SP-Platform Maintenance
Node

Local CGW

Local CGW

Terminal Server

Catalyst 3550

Catalyst 3550

7613 GGSN
(1/2/3/4 MWAMs)
(1/2 Ethernet Cards)

Fig. 2.9 CPG-3300 configuration layout

2.7.2 Fuse Assignment CPG-3300 Configuration


FU valid for the 7613 GGSN integrated in the Siemens cabinet.

FU MUT Unit FU

Local CGW 4B, 8B


Local CGW 4A, 8A
Terminal Server 6B
Catalyst 3550 7A, 3A
7613 GGSN 1A, 1B, 2A
5A, 5B, 6A

Tab. 2.12 Fuse Assignment

26 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

2.7.3 CPG-3300 Basic

Cisco 7613 GGSN Basic


1 SUP2/MSFC2
2
3 48-port E/FE card
4
5 optional line card
6 optional line card
7
8
9 optional IPSec card
10 optional line cards
11 optional line cards
12 MWAM #1
13
4000W DC 4000W DC
Power Supply Power Supply

Fig. 2.10 R:OEM:GGSN-C (CPG-3300 Basic)

2.7.4 SUP2/MSFC2

Fig. 2.11 SUP2/MSFC2 Front Panel

A50016-D1703-M1-4-7620 27
Construction MP/SP-Platform Maintenance
Node

LED Color Description

Status Orange The module is booting or running diagnostics (normal initialization sequence).

An over temperature condition has occurred. (A minor threshold has been exceeded
during environmental monitoring.)

Green All diagnostics pass; the module is operational (normal initialization sequence).

Red Diagnostic test failed; the module is not operational. (The fault occurred during the
initialization sequence.)

An over temperature condition has occurred. (A major threshold has been exceeded
during environmental monitoring.)
System1 Orange The power supply or power supply fan failed.

Incompatible power supplies are installed.

The redundant clock failed.

One VTT2 module has failed or the VTT module temperature minor threshold has
been exceeded3.

Red Two VTT modules failed or the VTT module temperature major threshold has been
exceeded3.

The temperature of the supervisor engine major threshold has been exceeded.

Green All chassis environmental monitors are reporting OK.

Active Orange The supervisor engine is in standby mode.

Green The supervisor engine is operational and active.


PWR MGMT Orange Sufficient power is not available for all modules.
1

Green Sufficient power is available for all modules.


Switch Load If the system is operational, the switch load meter indicates (as an approximate per-
centage) the current traffic load over the backplane.
PCMCIA The PCMCIA LED is lit when no PCMCIA card is in the slot and goes when you insert
a card.
Link Orange The link has been disabled by software.

Flashing or- The link is bad and has been disabled due to a hardware failure.
ange

Green The port is operational

OFF No signal is detected.

Tab. 2.13 SUP2

28 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

1. The SYSTEM and PWR MGMT LED indications on a redundant supervisor engine
are synchronized to the active supervisor engine.
2. VTT = voltage termination module. The VTT module terminates signals on the system
switching bus.
3. If no redundant supervisor engine is installed and there is a VTT module minor or ma-
jor over temperature condition, the system shuts down.

A50016-D1703-M1-4-7620 29
Construction MP/SP-Platform Maintenance
Node

2.7.5 48-port E/FE card

Fig. 2.12 48-port E/FE card

LED Color Description

Status Red The module is resetting (The system has just been powered on or the module
has been hot inserted - this is the normal initialization sequence.).

An overtemperature condition has occurred (A major threshold has been ex-


ceeded during environmental monitoring.).

If the module fails to download code and configuration information successfully


during the initial reset, the LED stays red; the module does not come online.

Orange The module is booting or running diagnostics (the normal initialization se-
quence).

An overtemperature condition has occurred (A minor threshold has been ex-


ceeded during environmental monitoring.).

Green All diagnostics pass; the module is operational.

Green to Or- The module is disabled through the CLI1.


ange

Off The module is not receiving power.


Link Green The port is active (link connected and operational).

Orange The module or port is disabled through the CLI command or the module
is initializing2.
Flashing Or- The port is faulty and has been disabled.
ange

Off The port is not active or the link is not connected.

Tab. 2.14 48-port E/FE card status LEDs

1. CLI = command-line interface.


2. This is a good time to verify that all LINK LEDs are functioning.

30 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

2.7.6 MWAM

Fig. 2.13 MWAM Front Panel


MWAM Status LED
The Status LED indicates the operating states of the module.

Color/State Description

Green All diagnostic tests pass. The module is operational.


Red A diagnostic other than an individual port test failed.
Orange Indicates one of three conditions:
- The module is running through its boot and self-test
diagnostic sequence.
- The module is disabled.
- The module is in the shutdown state.
Off The module power is off.

Tab. 2.15 MWAM Status LEDs

A50016-D1703-M1-4-7620 31
Construction MP/SP-Platform Maintenance
Node

2.7.7 CPG-3300 Large

Cisco 7613 GGSN Large


1 SUP2/MSFC2
2 Redundant SUP2/MSFC2
3 48-port E/FE card
4 Redundant 48-port E/FE
5 optional line card
6 optional line card
7 MWAM #3
8
9 optional IPSec card
10 optional line cards
11 optional line cards
12 MWAM #1
13 MWAM #2
4000W DC 4000W DC
Power Supply Power Supply

Fig. 2.14 R:OEM:GGSN-C (CPG-3300 Large)

2.7.8 CPG-3300 Extra Large

Cisco 7613 GGSN Extra Large


1 SUP2/MSFC2
2 Redundant SUP2/MSFC2
3 48-port E/FE card
4 Redundant 48-port E/FE
5 optional line card
6 optional line card
7 MWAM #3
8 MWAM #4
9 optional IPSec card
10 optional line cards
11 optional line cards
12 MWAM #1
13 MWAM #2
4000W DC 4000W DC
Power Supply Power Supply

Fig. 2.15 R:OEM:GGSN-C (CPG-3300 Extra Large)

32 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

2.7.9 Local Charging Gateway (LCG)


Under normal circumstances, GGSNs support the centralized charging gateway in
which call records are sent to the remote billing centre via the Ga-interface.

Gn-interface Gi-interface
GGSN
O&M interface

CPG-3200/3300

Ga-interface

LCG

Charging Interface (FTP) Ga-interface

Fig. 2.16 GGSN architecture


In order to prevent loss of data, a GGSN can be equipped with a local charging gateway
(LCG). The communication between the GGSN and the LCG runs over the internal Ga-
interface. If the connection between the GGSN and the central charging gateway (CCG)
were to fail, the GGSN would continue sending charging data to the LCG until the con-
nection is recovered. The GGSN re-establishes the original path to the CCG and con-
tinues sending charging data to that destination. The charging data which was collected
during the downtime of the link can then be transferred from the LCG via FTP. When
redundancy is required, a second LCG can be installed. Or as an alternative, an LCG
can be shared amongst multiple GGSNs. The component responsible for this is the Sun
Netra V240 Server which is designed for high-performance, high-density environments
and provides significant expandability. Occupying only two rack units of vertical space,
the Netra V240 server is configured with high-performance, 64-bit, SPARC® Version 9-
compliant UltraSPARC IIIi processors, each with 1 MB of L2 cache.
In order to store this charging data on the LCG, the SUN StorEdge 3310 SCSI Disk array
is implemented. This is a high performance storage system with Redundant Array Inex-
pensive Device (RAID) technology. Its disk drivers form factor is 3.5 inch and the power
consumption is 700 W.

2.8 R:OEM:eGGSN-C (IPS-3300)

2.8.1 General Layout


eGGSN provides a combination of GGSN, Selection Service Gateway (SSG) and a
Content Server Gateway (CSG) from a single platform, the Cisco 7613 router. Two con-
figurations are possible for the IPS-3300. A basic configuration and a large configura-
tion. The difference between these two configurations is the number of MWAM (Mobile
Wireless Access Module) SSG and GGSN cards and Content Switching Module (CSM)
CSG cards. For a large configuration, all these are doubled. The terminal server and the
LAN-switch catalyst are both optional while at the same time the eGGSN can be
equipped with the optional Local Charging Gateway (LCG) as described in 2.7.9 "Local

A50016-D1703-M1-4-7620 33
Construction MP/SP-Platform Maintenance
Node

Charging Gateway (LCG)". eGGSN is redundant by the use of a dual-shelf approach


where GGSN, SSG and CSG are identically configured.

Local CGW Local CGW

Disk Array Disk Array

Terminal Server Terminal Server

Catalyst 3550 Catalyst 3550

7613 eGGSN 7613 eGGSN


(1/2 GGSNs) (1/2 GGSNs)
(2/4 CSGs) (2/4 CSGs)
(1/2 SSGs) (1/2 SSGs)

Fig. 2.17 IPS-3300 configuration layout

2.8.2 Fuse Assignment IPS-3300 Configuration


FU valid for the 7613 GGSN integrated in the Siemens cabinet.

FU MUT Unit FU

Local CGW 4B, 8B


Disk Array 3B, 7B
Terminal Server 6B
Catalyst 3550 7A, 3A
7613 eGGSN 1A, 1B, 2A
5A, 5B, 6A

Tab. 2.16 Fuse Assignment

34 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

2.8.3 IPS-3300 Basic

Cisco 7613 eGGSN Basic


1 SUP2/MSFC2
2 Redundant SUP2/MSFC2
3 48-port E/FE card
4 CSM/CSG #1
5 48-pt E/FE or 16-pt GE
6 CSM FWLB or opt. LIC
7 MWAM SSG #1
8
9 CSM/CSG #2
10
11
12 MWAM GGSN #1
13
4000W DC 4000W DC
Power Supply Power Supply

Fig. 2.18 R:OEM:eGGSN-C (IPS-3300 Basic)

2.8.4 16-port GE card


For SUP2/MSFC2, 48-port E/FE card and MWAM see chapter 2.7.4, 2.7.5 and 2.7.6.

Fig. 2.19 16-port E/FE card


See Tab. 2.14 for further information about the LED status.

2.8.5 CSM/CSG

Fig. 2.20 CSM/CSG Front Panel

A50016-D1703-M1-4-7620 35
Construction MP/SP-Platform Maintenance
Node

Color Description

Off - The module is waiting for the supervisor engine to provide power.
- The module is not on line.
- The module is not receiving power, which could be caused by the
following:
˚ Power is not available to the CSG.
˚ Module temperature is over the limit. Enter the show environment
temperature mod command to display the temperature of each of four
sensors on the CSG.

Red - The module is released from reset by the supervisor engine and is boot-
ing.
- If the boot code fails to execute, the LED stays red after power up.
Orange - The module is initializing hardware or communicating with the supervi-
sor engine.
- A fault occurred during the initialization sequence.
- The module has failed to download its Field Programmable Gate Arrays
(FPGAs) on power up, but continues with the remainder of the initializa-
tion sequence and provides the module online status from the supervisor
engine.
- The module has not received module online status from the supervisor
engine. This problem could be caused by the supervisor engine detecting
a failure in an external loopback test that is issued to the CSG.
Green - The module is operational; the supervisor engine has provided module
online status.
Green to - The module is disabled through the supervisor engine CLI using the fol-
orange lowing commands:
˚ config terminal
˚ no power enable module mod

Tab. 2.17 CSM/CSG

36 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

2.8.6 IPS-3300 Large

Cisco 7613 eGGSN Large


1 SUP2/MSFC2
2 Redundant SUP2/MSFC2
3 48-port E/FE card
4 CSM/CSG #1
5 48-pt E/FE or 16-pt GE
6 CSM FWLB or opt. LIC
7 MWAM SSG #1
8 MWAM SSG #2
9 CSM/CSG #2
10 CSM/CSG #3
11 CSM/CSG #4
12 MWAM GGSN #1
13 MWAM GGSN #2
4000W DC 4000W DC
Power Supply Power Supply

Fig. 2.21 R:OEM:eGGSN-C (IPS-3300 Large)

A50016-D1703-M1-4-7620 37
Construction MP/SP-Platform Maintenance
Node

2.9 R:OEM:SGSN

2.9.1 General Layout


The SGSN configuration is always realized with the XpressPass140 High Density shelf
(XP140HD), also named SURPASS hiD3140, and Cisco Catalyst Switch. For the cards
in the XpressPass140HD there are three possibilities: 2G, 3G or combined 2G/3G. Each
OEM rack of the SGSN system must contain either two XP140 frames or two XP140 HS
frames. Both frame types can not be mixed.

breaker panel breaker panel


GPS GPS
optional power splitter optional power splitter
optional DC/AC conv. optional DC/AC conv.
catalyst switch 0 -

- PIX515
- catalyst switch 0
- PIX515
- catalyst switch 1
front cable duct front cable duct
XpressPass140HD SGSN XpressPass140HD SGSN
2G 2G
3G 3G
2G/3G 2G/3G

air duct air duct


optional IDF optional IDF
optional front cable duct optional front cable duct
optional IDF optional IDF
optional front cable duct optional front cable duct

XpressPass140HD SGSN XpressPass140HD SGSN


2G 2G
3G 3G
2G/3G 2G/3G

optional IDF optional IDF


optional front cable duct optional front cable duct
optional IDF optional IDF
optional front cable duct optional front cable duct

Fig. 2.22 R:OEM:SGSN layout


The SGSN on the left is the layout without the Cisco integrated private internet ex-
change for IPSec (PIX515), the model on the right is with PIX515.

38 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

MUT Unit

MUT01 Breaker Panel

MUT02 GPS

MUT03 optional AC/DC convertor

MUT04 Catalyst Switch 0

MUT05 Access Switch XpressPass 140

MUT07 Access Switch XpressPass 140

MUT10 front cable duct


MUT11 air duct

MUT12 optional power splitter

MUT15 optional IDF

MUT16 optional IDF

MUT17 optional IDF


MUT18 optional IDF

MUT19 optional cable duct

MUT20 optional cable duct

MUT21 optional cable duct

MUT22 optional cable duct

Tab. 2.18 Fuse Assignment R:OEM:SGSN

MUT Unit

MUT23 PIX515

MUT24 Catalyst Switch 0

MUT25 PIX515

MUT26 Catalyst Switch 1

Tab. 2.19 Additional Fuse Assignment R:OEM:SGSN for PIX515

A50016-D1703-M1-4-7620 39
Construction MP/SP-Platform Maintenance
Node

2.9.2 2G-SGSN

XP140 2G-SGSN
1 PSU1
2 PSU2
3 PSU3
4 LIC (Gb)
5 LIC (Gb)
6 LIC (Gb)
7 LIC (Gb)
8 SP-BSSGP
9 LIC-STM1 to SSNC
10 SP-GTP
11 LIC-STM1(Gn-redundancy)
12 LIC (Gb)
13 LIC (Gn)
14 LIC (Gn)
15 MCP1

Fig. 2.23 2G-SGSN


The Gn-interface can be realized using only a single LIC per frame (either Ethernet or
ATM). For Gn redundancy, a second LIC which connects the two frames has to be used.

2.9.3 3G-SGSN

XP140 3G-SGSN
1 PSU1
2 PSU2
3 PSU3
4
5
6
7
8
9 LIC-STM1 to SSNC
10 LIC-STM1 to XP140HD
11 SP-GTP
12 SP-GTP
13 LIC (Gn)
14 LIC(Gn) redundancy F
15 MCP1

Fig. 2.24 3G-SGSN

40 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

The Gn-interface can be realized using only a single LIC per frame (either Ethernet or
ATM). For Gn redundancy, a second LIC which connects the two frames has to be used.
For Iu cross routing, a second LIC which connects the two frames has to be used. This
LIC provides Gn redundancy as well.

2.9.4 2G/3G-SGSN

XP140 2G/3G-SGSN
1 PSU1
2 PSU2
3 PSU3
4 LIC (Gb)
5 LIC (Gb)
6 LIC (Gb)
7 LIC (Gb)
8 SP-BSSGP
9 LIC-STM1 to SSNC
10 optional LIC-STM1
11 SP-GTP
12 LIC-STM1 to XP140HD
13 LIC (Gb)
14 LIC STM1/Ethernet (Gn)
15 MCP1

Fig. 2.25 2G/3G-SGSN

The Gn-interface can be realized using only a single LIC per frame (either Ethernet or
ATM). For Gn redundancy, a second LIC which connects the two frames has to be used.
For Iu cross routing, a second LIC which connects the two frames has to be used. This
LIC provides Gn redundancy as well. In order to obtain high performance, a second LIC
to the SSNC is needed. The number of Gn LICs must be reduced to less than the max-
imum values in order to support high Iu traffic and Iu cross functionality.

A50016-D1703-M1-4-7620 41
Construction MP/SP-Platform Maintenance
Node

2.10 Code Numbers for R:OEM

Designation Code Numbers Remarks

R:OEM:SGSN, 7ft S32005-C110-A100 ACCESS Switch HD, CATALYST


R:OEM:SGSN, 8ft S32005-C112-A100 ACCESS Switch HD, CATALYST
R:OEM:GGSN S32005-C122-X Rack (7ft) 4 BEAM RACK
R:OEM:GGSN S32005-C123-X Rack (8ft) 4 BEAM RACK
Breaker-Panel S32005-D110-X1
Fan S30050-B5681-X101
Fan-Box S32007-U102-X200
IDF C39324-A111-B91 Only for optical LIC Modules
Filter Fan C39300-A195-A11
ACCESS Switch 2 S30122-U1009-X100 SW R4.1 is necessary, Codenumber
with two Power Supplies
M:MCP S30122-U1012-X MCP Control card
M:PS S30122-U1013-X Power supply
M:PM:MCP S30122-U1015-X SP-Control Card Personality Module
M:PM:PS S30122-U1016-X Personality module:Power supply
M:PM:COAX:8 S30122-U1019-X Personality module with 8 pairs of
1.0x2.3 coax connectors
M:PM:FR S30122-U1022-X Personality module for FR-card
M:LIC:E1/T1:CFR S30122-U1023-X Eight port E1/T1 120 channelized
Frame Relay
M:LIC:ETH10/100 S30122-U1029-X ETH 10/100 LAN
M:PM:ETH S30122-U1030-X Personality module for ETH 10/100
LAN card
M:LIC:D-STM1 S30122-U1031-X Dual port STM1 ELECTR
M:BIAS-HP S32006-Q2020-X401
M:BIAS-HP S32006-Q2020-X501
M:BIAS-FX S32006-Q2022-X1
M:LIC:STM1:O15 S30122-U1053-X100 Intermediate reach 15 km FC/PC
Power Splitter S30122-U1054-X
ACCESS SWITCH S30122-U1055-X
HD
M:PSU S30122-U1057-X Power Supply for HD
M:PM:MCP-S S30122-U1059-X Personality Module XP 140HD Card
Type S PM

Tab. 2.20 Code Numbers for R:OEM

42 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Designation Code Numbers Remarks

M:PM:COAX:8 S30122-U1060-X Personality Module XP 140HD


1.0x2.3 PM
M:PM:E1/T1 S30122-U1061-X Personality Module XP 140HD RJ45
PM
M:LAN S30122-U1063-X Personality Module XP140HD Lan
PM
M:PM:STM1:CU S30122-U1066-X XP 140 BNC75 E1 CLK SEC 4.6
PPM PM
M:PM:STM1:CUHD S30122-U1088-X XP 140HD BNC75 OPT E1 CLK SEC
4.6 PPM PM
Hub S30122-U1007-X Baystack 106 HUB
CATALYST S30122-U1065-X
SWITCH
ACC FILE SERVER S30122-U1008-X Force PC
DCIRC S30050-B5886-X
Mounting Kit DCIRC S32005-C110-H1 Kit for DCIRC 7ft
Mounting Kit DCIRC S32005-C112-H1 Kit for DCIRC 8ft
Mounting Kit DCIRC S32005-C110-H100 Kit for DCIRC 7ft, 8ft
RCDA:GPS S30122-U1004-X Radio Clock
Mounting Kit RC- S32005-C110-H2 Kit for Radio ClockS32005-
DA:GPS C110/C112-X (7ft/8ft)
Mounting Kit RC- S32005-C110-H200 Kit for Radio Clock S32005-
DA:GPS C110/112-X100 (7ft/8ft)
Mounting Kit Power S32005-C110-H3 Kit for Power Splitter
ANTA:RCD S30122-U649-X Antenna
LPA:RCD S30122-U649-X100 Lightning Protection for Antenna
AMPLA:ANT S30122-U650-X Amplifier
SW:CR-300 S30122-U1069-X Software to License Support for Car-
rier Routing Feature PAK
SW:LNSGRTN-LTU S30122-U1087-X SW License for Unlimited LNS Tun-
nels
M:E3-ATM S30122-U1043-X 3 Port Unchannelized E3;ATM Line
Module
M:E3-I/O S30122-U1044-X 3 Port E3 Interface Adapter
M:SRP-10-ECC S30122-U1068-X 10 GIG SRP with Error Checking and
Correcting Capability
M:SRP-I/O S30122-U1038-X Switch and Route Processor Inter-
face Adapter

Tab. 2.20 Code Numbers for R:OEM

A50016-D1703-M1-4-7620 43
Construction MP/SP-Platform Maintenance
Node

Designation Code Numbers Remarks

M:E3-FR S30122-U1071-X 3 Port Unchannelized E3, FR and


PPP Line Module
M:E3-I/O S30122-U1044-X 3 Port E3 Interface Adapter
M:OC3/OC12-ATM S30122-U1072-X 4 Port OC3/STM1 and 1
OC12/STM4 ATM Line Module
M:OC3/OC12-POS S30122-U1073-X 4 Port OC3/STM1 and 1
OC12/STM4 POS Line Module
M:OC3-4SM I/O S30122-U1074-X 4 Port OC3/STM1 SM I/O
M:OC12-SM I/O S30122-U1086-X 1 Port OC12/STM4 SM I/O
M:TS-L2TP S30122-U1076-X Supports L2TP LNS and GRE Multi-
cast Tunneling
M:GE/FE-8 S30122-U1077-X 1 Port GE and 8 Port 10/100 FE Line
Module
M:FE-8 I/O S30122-U1078-X 8 Port 10/100 FE I/O
M:GE S I/O S30122-U1080-X 2 Port Gigabit Ethernet I/O SM
M:FAN-14 S30122-U1082-X Replacement Fan for 14 Slot Chas-
sis
M:PDU S30122-U1083-X Replacement Power Distribution Unit
for ERX-700 or ERX-1400

Tab. 2.20 Code Numbers for R:OEM

44 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

3 Module Frames
3.1 MPP (Main Processor Platform)
3.2 SPP (Server Processor Platform)
3.3 OEM Devices

A50016-D1703-M1-4-7620 45
Construction MP/SP-Platform Maintenance
Node

3.1 MPP (Main Processor Platform)


3.1.1 F:SCB
3.1.2 F:SCE
3.1.3 F:ASN(E) (ASN40 shelf)
3.1.4 F:ASN(H) (ASN20 shelf)
3.1.5 F:SXCB (ASN5 shelf)
3.1.6 F:SXCB (ASN5 single shelf with AMXE and MP:OAMD)

3.1.1 F:SCB

3.1.1.1 F:SCB (module side)

P1

P2

C P3

P4

P5

P1

P2
LIC or MPU 00

LIC or MPU 01

LIC or MPU 10

LIC or MPU 11

D P3

MPU:SA 00

MPU:SA 01
ACCG 00

ACCG 01
AMXE 00

AMXE 01

IMDD 01
MOD 00

MOD 01
MDD 00
P4
ALIB

P5
C103

C127

C139

C159

C179

C191

C201

C221

C243

C275

C299

C319

C339

C361
C115

Modules with displays and switches in F:SCB

ACCG (Q145) (Q1022) ACCG (Q1161) AMXE (Q1019) ALIB (Q1065)

MPUC (Q80-X401) MPUC (Q82-X401) MPUD (Q83-X401) MPUD (Q83-X801)

MPUD (Q83-X901) MPUD (Q208-X801) MPUD (Q208-X801) MPUE (Q270-X801)

MPUE (Q270-X901) MPUE (Q271-X801) MPUE (Q271-X901) MPUE (Q274-X801)

MDD (U107-X100) MDD (U2594) MOD (Q1028)

Tab. 3.1 Modules with displays and switches in F:SCB

46 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

3.1.1.2 F:SCB (backplane)


17 16 5 5
P1 14
17 16
3 3
15 15 14 6
P2 1
6

10 6
P3
C 3 3
P4 11 20 1

P5 12 14
22 22 3 3
P1 14

P2
3 3
D P3 21 21

P4 6
20
6 4
4 4 4
P5 6 24 28 28
28 28 20
375

263
375
363
351

329
319
309
299

275

251

231
211

191
179

169

149

127
115
103
285

233

139
Strapping plugs
Connector 20
C169P4 code plug ACCG0 / 1
D285P4 code plug MPU-SA0
D285P5 code plug MPU-SA1
Connector 22
C233P4 SCSI term. MDD/MOD Plane 0
C377P4 SCSI term. MDD/MOD Plane 1

3.1.1.3 F:SCB (cabling)


for example: C263P1, C263R1
i P is the upper plug within one system unit; R is the lower plug within one system unit;

Cabling F:SCB <--> IDF (Connector 1

From F:SCB To IDF / Strapping Plug

Connector Unit MOLOC

1 F:SCB C103P2 IDF x001, E1-sym./COAX, DS1-sym

1 F:SCB C103P4 IDF x003, E1-sym./COAX, DS1-sym

Tab. 3.2 F:SCB <---> IDF (Connector 1)

A50016-D1703-M1-4-7620 47
Construction MP/SP-Platform Maintenance
Node

Cabling F:SCB <--> Ethernet (Connector 21, 28)

From F:SCB Ethernet interface

Connector Unit MOLOC

21 F:SCB 09D309P3 AUI interface to MPU(SA)0

21 F:SCB 09D329P3 AUI interface to MPU(SA)1

28 F:SCB 09D299P5 MPU(SA)0 only frame X2755

28 F:SCB 09D319P5 MPU(SA)1 only frame X2755

28 F:SCB 09D127P5 MPU10 only frame X2755


28 F:SCB 09D139P5 MPU11 only frame X2755

Tab. 3.3 F:SCB <---> Ethernet (Connector 21, 28)

Cabling F:SCB <--> F:MBD (Connector 3)

From F:SCB To F:MBD

Connector Unit MOLOC Unit MOLOC

3 - FOTX F:SCB / AMX0 09C149P1 (P2) F:MBD0 / MBDA0 C157P1

3 - FOTX F:SCB / AMX1 09C211P1 (P2) F:MBD0 / MBDA0 C157P3

3 - FOTX F:SCB / AMX0 09C149P5 (P1) F:MBD0 / MBDA0 C157P5

3 - FOTX F:SCB / AMX1 09C211P5 (P1) F:MBD0 / MBDA0 D157P2

3 - FOTX F:SCB / AMX0 09D149P3 (P4) F:MBD1 / MBDA0 C157P1

3 - FOTX F:SCB / AMX1 09C211P3 (P4) F:MBD1 / MBDA0 C157P3

3 - FOTX F:SCB / AMX0 09D149P2 (P3) F:MBD1 / MBDA0 C157P5

3 - FOTX F:SCB / AMX1 09D211P2 (P3) F:MBD1 / MBDA0 D157P2

Tab. 3.4 Cabling F:SCB <--> F:MBD

Cabling F:SCB <----> F:BPCE (Connector 4)

From F:SCB To F:BPCE

Connector Unit MOLOC Unit MOLOC

4 - FOTX F:SCB 09D149P4 (P5) F:BPCE 07D209P3 (P2)

4 - FOTX F:SCB 09D169P4 (P5) F:BPCE 07D285P3 (P2)

4 - FOTX F:SCB 09D211P4 (P5) F:BPCE 07D209P5 (P2)

4 - FOTX F:SCB 09D231P4 (P5) F:BPCE 07D285P5 (P2)

Tab. 3.5 Cabling F:SCB <----> F:BPCE (Connector 4)

48 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Cabling F:SCB <--> F:PIOP(B) (Connector 4)

From F:SCB To F:PIOP(B)

Connector Unit MOLOC Unit MOLOC

4 - FOTX F:SCB 09D149P4 (P5) F:PIOP(B)0 03C109P3 (P2)

4 - FOTX F:SCB 09D169P4 (P5) F:PIOP(B)1 07C109P3 (P2)

4 - FOTX F:SCB 09D211P4 (P5) F:PIOP(B)0 03D109P3 (P2)

4 - FOTX F:SCB 09D231P4 (P5) F:PIOP(B)1 07D109P3 (P2)

Tab. 3.6 Cabling F:SCB <---> F:PIOP(B) (Connector 4)

Cabling F:SCB <----> F:SCE (Connector 6, 24)

From F:SCB To F:SCE Remarks

Connector Unit MOLOC Unit MOLOC

6 F:SCB 09C169P2 F:SCE 03C241P1 Clock interface T0 out next


frame plane 0
6 F:SCB 09C169R2 F:SCE 05C241P1

6 F:SCB 09C169P3 F:SCE 07C241P1

6 F:SCB 09D251P4 F:SCE 03C241P2 Clock interface T0 out next


frame plane 1
6 F:SCB 09D251R4 F:SCE 05C241P2

6 F:SCB 09D251P5 F:SCE 07C241P2

24 F:SCB 09D191P5 F:SCE, ext. rack 07C241P3 Alarm out

Tab. 3.7 Cabling F:SCB <----> F:SCE (Connector 6, 24)

Cabling F:SCB <----> F:ASN(E) (Connector 5, 12, 14, 16)

From F:SCB To F:ASN(E) Remarks

Connector Unit MOLOC Unit MOLOC

5 F:SCB 09C251P1 F:ASN(E) 1 05C103P1 RTTL interface

5 F:SCB 09C169P1 F:ASN(E) 1 07C103P1

12 F:SCB 09C191P5 F:ASN(E) 0 07C123P2 Alarm out

14 F:SCB 09C169P5 F:ASN(E) 0 07C133P3 ASN interface

14 F:SCB 09C231P1 F:ASN(E) 1 05C133P3

14 F:SCB 09C231P2 F:ASN(E) 1 05C133P4

14 F:SCB 09D169P1 F:ASN(E) 0 07C133P4

16 F:SCB 09C263P1 F:ASN(E) 0 07C123R2 Line timing out

16 F:SCB 09C263R1 F:ASN(E) 1 05C123R2

Tab. 3.8 Cabling F:SCB <----> F:ASN(E) (Connector 5, 12, 14, 16)

A50016-D1703-M1-4-7620 49
Construction MP/SP-Platform Maintenance
Node

Cabling F:SCB <----> Breaker panel (Connector 11)

From F:SCB To Breaker panel

Connector Unit MOLOC Unit

11 F:SCB 09C191P4 ALMC alarm in

Tab. 3.9 Cabling F:SCB <----> Breaker panel (Connector 11)

Cabling F:SCB <----> F:ASN(H) (Connector 5, 12,14, 16)

From F:SCB To F:ASN(H) Remarks

Connector Unit MOLOC Unit MOLOC

5 F:SCB 09C169P1 F:ASN(H) 07C173P2 RTTL interface

5 F:SCB bas. Rack 09C251P1 F:ASN(H) 07D321R1

5 F:SCB ext. Rack 1 09C251P1 F:ASN(H) 07D321P2


12 F:SCB 09C191P5 F:ASN(H) 07C163P1 Alarm out

14 F:SCB 09C169P5 F:ASN(H) 07C111P3 ASN interface

14 F:SCB 09C169P1 F:ASN(H) 07C111P4

14 F:SCB 09C231P1 F:ASN(H) 07C259P3

14 F:SCB 09C231P2 F:ASN(H) 07C259P4

16 F:SCB 09C263P1 F:ASN(H) 07C173R2 Line timing out

16 F:SCB 09C263R1 F:ASN(H) 07C321R2

Tab. 3.10 Cabling F:SCB <----> F:ASN(H) (Connector 5, 12,14, 16)

Cabling F:SCB internal (Connector 10, 14, 15, 16, 17)

From F:SCB To F:SCB

Connector Unit MOLOC Unit MOLOC

10 (**) F:SCB 09C191P3 Radio Clock

14 (*) F:SCB 09C169P5 F:SCB 09D169P1

14 (*) F:SCB 09C231P1 F:SCB 09C231P2

15 (#) F:SCB 09C251P2 F:SCB 09C263P2

16 / 17 (*) F:SCB 09C263P1 F:SCB 09C275P1

(*) Reference clock in F:SCB if F:ASN(E) is not existing


(**) only for stand alone
(#) Frame internal in every F:SCB

Tab. 3.11 Cabling F:SCB internal (Connector 10, 14, 15 16, 17)

50 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

3.1.2 F:SCE

3.1.2.1 F:SCE (module side)

P1

P2

C P3

P4

P5

P1

P2
LIC or MPU 20

LIC or MPU 21

LIC or MPU 30

LIC or MPU 31

LIC or MPU 40

LIC or MPU 41

LIC or MPU 50

LIC or MPU 51

LIC or MPU 61
LIC or MPU 11
LIC or MPU 00

LIC or MPU 01

LIC or MPU 10

LIC or MPU 60

LIC or MPU 70

LIC or MPU 71
D P3

ACCG 00

ACCG 01
AMXE 00

AMXE 01
P4

P5
C103

C115

C127

C139

C151

C163

C175

C187

C211

C231

C251

C271

C291

C303

C315

C327

C339

C351

C363

C375
Modules with displays and switches in F:SCE

ACCG (Q145) (Q1022) ACCG (Q1161) AMXE (Q1019) LIC:1,5A (Q1013)

LIC:1.5A-P (Q1125) LIC:2A (Q1014) LIC:2A-P (Q1126-X1) MPUC (Q80-X401)

MPUC (Q82-X401) MPUD (Q83-X401) MPUD (Q83-X801) MPUD (Q83-X901)

MPUD (Q208-X801) MPUD (Q208-X901) MPUE (Q270-X801) MPUE (Q270-X901)

MPUE (Q270-X801) MPUE (Q271-X901) MPUE (Q271-X801) MDD (U107-X100)

MDD (U2594) MOD (Q1028)

Tab. 3.12 Modules with displays and switches in F:SCE

A50016-D1703-M1-4-7620 51
Construction MP/SP-Platform Maintenance
Node

3.1.2.2 F:SCE (backplane)

6 5 6
P1 6 6
3 3
6 5 6
P2 1 1 1 1 1 1 1 1 1 1 1 1
5

C P3 1 1 14 11 14 1 1 1 1 1
3 3
P4 1 1 1 1 14 12 14 1 1 1 1 1 1 1

P5 1 1 14 14 1 1 1 1 1
3 3
P1 14 14

16
P2 14 14
16
D 14
3 3
14
P3

P4 14 14

P5 24 24 24 24 24 24 24 20 14 14 24 24 24 24 24 24 24 20

281

241
375

363
351

339

327
315

303

291

261

221

201

187

175

163

151
139

127

115
103
3.1.2.3 F:SCE (cabling)
for example: C263P1, C263R1
i P is the upper plug within one system unit; R is the lower plug within one system unit;

Cabling F:SCE <--> IDF and Strapping plugs (Connector 1)


LIC interfaces

From F:SCE To IDF / Strapping Plug

Connector Unit MOLOC

1 F:SCE C103P2 IDF x005, E1- sym./COAX, /DS1- COAX

1 F:SCE C103P4 IDF x007, E1- sym./COAX, /DS1- COAX


1 F:SCE C115P2/P3/P4/P5 strapping plugs

1 F:SCE C127P2 IDF x013, E1- sym./COAX, /DS1- COAX

1 F:SCE C127P4 IDF x015, E1- sym./COAX, /DS1- COAX

1 F:SCE C139P2/P3/P4/P5 strapping plugs

1 F:SCE C151P2 IDF x001, E1- sym./COAX, /DS1- COAX (*)

1 F:SCE C151P4 IDF x003, E1- sym./COAX, /DS1- COAX (*)

1 F:SCE C163P2/P3/P4/P5 strapping plugs (*)

1 F:SCE C175P2 IDF x009, E1- sym./COAX, /DS1- COAX

1 F:SCE C175P4 IDF x011, E1- sym./COAX, /DS1- COAX

1 F:SCE C187P2/P3/P4/P5 strapping plugs

1 F:SCE C339P2 IDF x017, E1- sym./COAX, /DS1- COAX

1 F:SCE C339P4 IDF x019, E1- sym./COAX, /DS1- COAX

1 F:SCE C351P2/P3/P4/P5 strapping plugs

Tab. 3.13 Cabling F:SCE <-> IDF and strapping plugs (connector 1)

52 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

From F:SCE To IDF / Strapping Plug

Connector Unit MOLOC

1 F:SCE C363P2 IDF x025, E1- sym./COAX, /DS1- COAX

1 F:SCE C363P4 IDF x027, E1- sym./COAX, /DS1- COAX

1 F:SCE C375P2/P3/P4/P5 strapping plugs

1 F:SCE C151P3 IDF x001/ Port 0 for Mobile Networks (*)

1 F:SCE C151P4 IDF x001/ Port 1 for Mobile Networks (*)

1 F:SCE C163P2 IDF x002/ Port 0 for Mobile Networks (*)


1 F:SCE C163P4 IDF x002/ Port 1 for Mobile Networks (*)

Tab. 3.13 Cabling F:SCE <-> IDF and strapping plugs (connector 1)

Cabling F:SCE <--> F:MBD (Connector 3)

From SSNC To MBD

Connector Unit MOLOC Unit MOLOC

3 - FOTX F:SCE0 / AMX0 C221P1 F:MBD0 / MBDA1 C259P1

3 - FOTX F:SCE0 / AMX1 C262P1 F:MBD0 / MBDA1 C259P3

3 - FOTX F:SCE0 / AMX0 C221P5 F:MBD0 / MBDA1 C259P5

3 - FOTX F:SCE0 / AMX1 C261P5 F:MBD0 / MBDA1 D259P2

3 - FOTX F:SCE0 / AMX0 C221P1 F:MBD1 / MBDA1 C259P1

3 - FOTX F:SCE0 / AMX1 C261P1 F:MBD1 / MBDA1 C259P3

3 - FOTX F:SCE0 / AMX0 C221P5 F:MBD1 / MBDA1 C259P5

3 - FOTX F:SCE0 / AMX1 C261P5 F:MBD1 / MBDA1 D259P2

3 - FOTX F:SCE1 / AMX0 C221P1 F:MBD0 / MBDA2 C125P1

3 - FOTX F:SCE1 / AMX1 C261P1 F:MBD0 / MBDA2 C125P3

3 - FOTX F:SCE1 / AMX0 C221P5 F:MBD0 / MBDA2 C125P5

3 - FOTX F:SCE1 / AMX1 C261P5 F:MBD0 / MBDA2 D125P2

3 - FOTX F:SCE1 / AMX0 C221P1 F:MBD1 / MBDA2 C125P1

3 - FOTX F:SCE1 / AMX1 C261P1 F:MBD1 / MBDA2 C125P3

3 - FOTX F:SCE1 / AMX0 C221P5 F:MBD1 / MBDA2 C125P5

3 - FOTX F:SCE1 / AMX1 C261P5 F:MBD1 / MBDA2 D125P2

3 - FOTX F:SCE1 / AMX0 C221P1 F:MBD0 / MBDA3 C325P1

3 - FOTX F:SCE2 / AMX1 C261P1 F:MBD0 / MBDA3 C325P3

3 - FOTX F:SCE2 / AMX0 C221P5 F:MBD0 / MBDA3 C325P5

3 - FOTX F:SCE2 / AMX1 C261P5 F:MBD0 / MBDA3 D325P2

3 - FOTX F:SCE2 / AMX0 C221P1 F:MBD1 / MBDA3 C325P1

3 - FOTX F:SCE2 / AMX1 C261P1 F:MBD1 / MBDA3 C325P3

3 - FOTX F:SCE2 / AMX0 C221P5 F:MBD1 / MBDA3 C325P5

3 - FOTX F:SCE2 / AMX1 C261P5 F:MBD1 / MBDA3 D325P2

Tab. 3.14 Cabling F:SCE<--> F:MBD

A50016-D1703-M1-4-7620 53
Construction MP/SP-Platform Maintenance
Node

From SSNC To MBD

Connector Unit MOLOC Unit MOLOC

3 - FOTX F:SCE3 / AMX0 C221P1 F:MBD0 / MBDA4 C293P1

3 - FOTX F:SCE3 / AMX1 C261P1 F:MBD0 / MBDA4 C293P3

3 - FOTX F:SCE3 / AMX0 C221P5 F:MBD0 / MBDA4 C293P5

3 - FOTX F:SCE3 / AMX1 C261P5 F:MBD0 / MBDA4 D293P2

3 - FOTX F:SCE3 / AMX0 C221P1 F:MBD1 / MBDA4 C293P1

3 - FOTX F:SCE3 / AMX1 C261P1 F:MBD1 / MBDA4 C293P3


3 - FOTX F:SCE3 / AMX0 C221P5 F:MBD1 / MBDA4 C293P5

3 - FOTX F:SCE3 / AMX1 C261P5 F:MBD1 / MBDA4 D293P2

Tab. 3.14 Cabling F:SCE<--> F:MBD

54 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Cabling F:SCE <----> F:SCB (Connector 5, 11)


Clock in basic rack from F:SCB to F:SCE MUT03
Clock in basic rack from F:SCB to F:SCE MUT05
Clock in extension rack from F:SCB to F:SCE MUT07

From F:SCE To F:SCB Remarks

Connector Unit MOLOC Unit MOLOC

5 F:SCE 03C241P2 F:SCB 09D251P4 RTTL interface

5 F:SCE 03C241P1 F:SCB 09C169P2

5 F:SCE 05C241P2 F:SCB 09D251R4

5 F:SCE 05C241P1 F:SCB 09C169R2

5 F:SCE 07C241P1 F:SCB 09C169P3

5 F:SCE ext. rack 07C241P1 F:SCB ext. rack 09D251P5

5 F:SCE ext. rack 07C241P2 F:SCB ext. rack 09C169P5


11 F:SCE 07C241P3 F:SCB 09C191P5 Alarm out

Tab. 3.15 Cabling F:SCE <----> F:SCB (Connector 5, 11)

Cabling F:SCE internal (Connector 5, 6, 11, 12, 20)

From F:SCE To F:SCE Remarks

Connector Unit MOLOC Unit MOLOC

5-6 F:SCE ext. rack 03C241P1 F:SCE ext. rack 09C201P1 Clock connections

5-6 F:SCE ext. rack 03C241P2 F:SCE ext. rack 09C281P1

5-6 F:SCE ext. rack 05C241P1 F:SCE ext. rack 09C201R1

5-6 F:SCE ext. rack 05C241P2 F:SCE ext. rack 09C281R1

5-6 F:SCE ext. rack 07C241P1 F:SCE ext. rack 09C201P2

5-6 F:SCE ext. rack 07C241P2 F:SCE ext. rack 09C281P2

11 from Breaker Panel ALMC ext. rack F:SCE ext. rack 09C241P3

12 - 11 F:SCE 09C241P4 F:SCE 07C241P3 Alarming

12 - 11 F:SCE 07C241P4 F:SCE 05C241P3

12 - 11 F:SCE 05C241P4 F:SCE 03C241P3

20 F:SCE D291P5 strapping plug in every F:SCE Code plug

Tab. 3.16 Cabling F:SCE internal (Connector 5, 6, 11, 12, 20)

A50016-D1703-M1-4-7620 55
Construction MP/SP-Platform Maintenance
Node

Cabling F:SCE <--> F:ASN(E) (Connector 5, 11, 14, 16)


14: ASN interface

From F:SCE To F:ASN(E)

Connector Unit MOLOC Unit MOLOC Remarks

5 (*) F:SCE 09D241P2 F:ASN(E) 1 05C103R1 Clock connections

5 (*) F:SCE 09D241P1 F:ASN(E) 0 07C103R1

5 (#) F:SCE 09D241P2 F:ASN(E) 1 05C103P2

5 (#) F:SCE 09D241P1 F:ASN(E) 0 07C103P2

11 F:SCE 03C241P3 F:ASN(E) 05C123P3 Alarming

14 F:SCE C201P3 F:ASN(E) 0 07Cx Basic connection (connection 0)

14 F:SCE C201P4 F:ASN(E) 0 07Cx

14 F:SCE C281P3 F:ASN(E) 1 05Cx

14 F:SCE C281P4 F:ASN(E) 1 05Cx


14 F:SCE C201P5 F:ASN(E) 0 07Cx 1. additional connection (connection 1)

14 F:SCE D201P1 F:ASN(E) 0 07Cx

14 F:SCE C281P5 F:ASN(E) 1 05Cx

14 F:SCE D281P1 F:ASN(E) 1 05Cx

14 F:SCE D201P2 F:ASN(E) 0 07Cx 2. additional connection (connection 2)

14 F:SCE D201P3 F:ASN(E) 0 07Cx

14 F:SCE D281P2 F:ASN(E) 1 05Cx

14 F:SCE D281P3 F:ASN(E) 1 05Cx

14 F:SCE D201P4 F:ASN(E) 0 07Cx 3. additional connection (connection 3)

14 F:SCE D201P5 F:ASN(E) 0 07Cx

14 F:SCE D281P4 F:ASN(E) 1 05Cx

14 F:SCE D281P5 F:ASN(E) 1 05Cx

16 F:SCE 03D241P2 F:ASN(E) 0 07C123P3 Line timing

16 F:SCE 03D241R2 F:ASN(E) 1 05C123P3

(*) Clock to F:SCE MUT09 in 1. extension rack


(#) Clock to F:SCE MUT09 in 2. extension rack

Tab. 3.17 Cabling F:SCE <--> F:ASN(E) (Connector 5, 11, 14, 16)

Cabling F:SCE <--> F:ASN(H) (Connector 5, 11, 14, 16)


14: ASN interface

56 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

From F:SCE To F:ASN(H)

Connec- Unit MOLOC Unit MOLOC Remarks


tor

5 (*) F:SCE 09D241P2 F:ASN(H) 07D321P2 Clock connections

5 (*) F:SCE 09D241P1 F:ASN(H) 07D173P2

5 (#) F:SCE 09D241P2 F:ASN(H) 07D321R2

5 (#) F:SCE 09D241P1 F:ASN(H) 07D173R2

11 F:SCE 5C241P3 F:ASN(H) 7C311P2 Alarming


14 F:SCE C201P3 F:ASN(H) 07Cx Plane 0 Basic connection (connection 0)

14 F:SCE C201P4 F:ASN(H) 07Cx Plane 0

14 F:SCE C281P3 F:ASN(H) 07Cx Plane 1

14 F:SCE C281P4 F:ASN(H) 07Cx Plane 1

14 F:SCE C201P5 F:ASN(H) 07Cx Plane 0 1. additional connection (connection


14 F:SCE D201P1 F:ASN(H) 07Cx Plane 0

14 F:SCE C281P5 F:ASN(H) 07Cx Plane 1

14 F:SCE D281P1 F:ASN(H) 07Cx Plane 1

14 F:SCE D201P2 F:ASN(H) 07Cx Plane 0 2. additional connection (connection 2)

14 F:SCE D201P3 F:ASN(H) 07Cx Plane 0

14 F:SCE D281P2 F:ASN(H) 07Cx Plane 1

14 F:SCE D281P3 F:ASN(H) 07Cx Plane 1

14 F:SCE D201P4 F:ASN(H) 07Cx Plane 0 3. additional connection (connection 3)

14 F:SCE D201P5 F:ASN(H) 07Cx Plane 0

14 F:SCE D281P4 F:ASN(H) 07Cx Plane 1

14 F:SCE D281P5 F:ASN(H) 07Cx Plane 1

16 F:SCE 03D241P2 F:ASN(H) 07C123P3 Line timing

16 F:SCE 03D241R2 F:ASN(H) 07C321P3

16 F:SCE 05D241P2 F:ASN(H) 07C123R3

16 F:SCE 05D241R2 F:ASN(H) 07C321R3

(*) Clock to F:SCE MUT09 in 1. extension rack


(#) Clock to F:SCE MUT09 in 2. extension rack

Tab. 3.18 Cabling F:SCE <--> F:ASN(H) (Connector 5, 11, 14, 16)

Cabling F:SCE Ethernet interface MPU (Connector 24)

From F:SCE Ethernet interface

Connector Unit MOLOC

24 F:SCE D109P5 MPU 00

24 F:SCE D121P5 MPU 01

24 F:SCE D133P5 MPU 10

Tab. 3.19 Cabling Ethernet interface MPU (Connector 24)

A50016-D1703-M1-4-7620 57
Construction MP/SP-Platform Maintenance
Node

From F:SCE Ethernet interface

Connector Unit MOLOC

24 F:SCE D145P5 MPU 11

24 F:SCE D157P5 MPU 20

24 F:SCE D169P5 MPU 21

24 F:SCE D181P5 MPU 30

24 F:SCE D193P5 MPU 31

24 F:SCE D302P5 MPU 40


24 F:SCE D313P5 MPU 41

24 F:SCE D323P5 MPU 50

24 F:SCE D333P5 MPU 51

24 F:SCE D343P5 MPU 60

24 F:SCE D355P5 MPU 61

24 F:SCE D365P5 MPU 70


24 F:SCE D376P5 MPU 71

Tab. 3.19 Cabling Ethernet interface MPU (Connector 24)

3.1.3 F:ASN(E) (ASN40 shelf)

3.1.3.1 F:ASN(E) (module side)

D
GMX 0

GMX 1

GMX 1

GMX 1

GMX 1

GMX 1

GMX 2

GMX 3
ASMG
ACCG

PSAG
C113

C141

C171

C171

C193

C241

C277

C295

C321

C347

C373

Modules with displays and switches in F:ASN(E)

ACCG (Q145) (Q1022) ACCG (Q1161) ASMG8/8 (Q1146) ASMG16/16 (Q1034)

GMX:E (Q1032) PSAG (Q6124)

Tab. 3.20 Modules with displays and switches in F:ASN(E)

58 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

3.1.3.2 F:ASN(E) (backplane)

PA CSO C0
P1 + RTL C1
PA RTL C2
P2 - CSI

C P3 R4 R0 R4 R0 R4 R0 R4 R0 PB
+ R4 R0 R4 R0 R4 R0 R4 R0
CSI

P4 T4 T0 T4 T0 T4 T0 T4 T0 PB T4 T0 T4 T0 T4 T0 T4 T0
-

P5 R5 R1 R5 R1 R5 R1 R5 R1 PC R5 R1 R5 R1 R5 R1 R5 R1
+

P1 T5 T1 T5 T1 T5 T1 T5 T1 PC T5 T1 T5 T1 T5 T1 T5 T1
-

P2 R6 R2 R6 R2 R6 R2 R6 R2 R6 R2 R6 R2 R6 R2 R6 R2 ASC
D
P3 T6 T2 T6 T2 T6 T2 T6 T2 T6 T2 T6 T2 T6 T2 T6 T2 ASC

P4 R7 R3 R7 R3 R7 R3 R7 R3 SC R7 R3 R7 R3 R7 R3 R7 R3

P5 T7 T3 T7 T3 T7 T3 T7 T3 SC T7 T3 T7 T3 T7 T3 T7 T3 ASC
381

365
355

339
328

313
303

287

263

227

211
201

185
175

159
149

133

123
103
Strapping plug
Connector SC

A50016-D1703-M1-4-7620 59
Construction MP/SP-Platform Maintenance
Node

3.1.3.3 F:ASN(E) (cabling)


for example: C263P1, C263R1
i P is the upper plug within one system unit; R is the lower plug within one system unit;

Power supply cabling (Connector PAx, PBx, PCx)

Connector MOLOC Connection

PA+ 05C263P1 Voltage supply side 0 Breaker panel of the rack fuse 03

PA- 05C263P2 Voltage supply side 0 Breaker panel of the rack fuse 04

PB+ 05C263P3 Voltage supply side 05 Breaker panel of the rack fuse 05

PB- 05C263P4 Voltage supply side 0 Breaker panel of the rack fuse 03

PC+ 05C263P5 Voltage supply side 0 Breaker panel of the rack fuse 04

PC- 05D263P1 Voltage supply side 0 Breaker panel of the rack fuse 05

PA+ 07C263P1 Voltage supply side 1 Breaker panel of the rack fuse 28

PA- 07C263P2 Voltage supply side 1 Breaker panel of the rack fuse 29
PB+ 07C263P3 Voltage supply side 1 Breaker panel of the rack fuse 30

PB- 07C263P4 Voltage supply side 1 Breaker panel of the rack fuse 28

PC+ 07C263P5 Voltage supply side 1 Breaker panel of the rack fuse 29

PC- 057D263P1 Voltage supply side 1 Breaker panel of the rack fuse 30

Tab. 3.21 Power supply cabling (Connector PAx, PBx, PCx)

Cabling F:ASN(E) <----> F:SCB

To F:ASN(E) From F:SCB Remarks

Connector Unit MOLOC Unit MOLOC

C0 (*) F:ASN(E) 0 07C103P1 F:SCB 09C251P1 Clock connections

C0 (*) F:ASN(E) 1 05C103P1 F:SCB 09C169P1

C0 (#) F:ASN(E) 0 07C103R1 F:SCB 09C169P1

C0 (#) F:ASN(E) 1 05C103R1 F:SCB 09C251P1

CSi F:ASN(E) 0 07C123R2 F:SCB 09C263P1 Line timing

CSi F:ASN(E) 1 05C123R2 F:SCB 09C263R1

RTL F:ASN(E) 0 07C123P2 F:SCB 09C191P5 RTTL interface

ASC F:ASN(E) 0 07D123P2 F:SCB 09C191P5 Alarming

(*) Clock basic rack


(#) Clock in first extension rack

Tab. 3.22 Cabling F:ASN(E) <----> F:SCB

60 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Cabling F:ASN(E) <----> F:SCE (Connector CSI, Cx)

To F:ASN(E) From F:SCE Remarks

Connector Unit MOLOC Unit MOLOC

CSI F:ASN(E) 1 05C123P3 F:SCE 03D241R2 Clock connections

CSI F:ASN(E) 0 07C123P3 F:SCE 03D241P2

C1 F:ASN(E) 1 05C103R1 F:SCE 09C241P2

C1 F:ASN(E) 0 07C103R1 F:SCE 09C241P1

C2 F:ASN(E) 1 05C103P2 F:SCE 09C241P2


C2 F:ASN(E) 0 07C103P2 F:SCE 09C241P1

ASC F:ASN(E) 1 05D123P3 F:SCE 03C241P3 Alarming

Tab. 3.23 Cabling F:ASN(E) <----> F:SCE (Connector CSI, Cx)

Cabling F:ASN(E) internal

To F:ASN(E) From F:ASN(E) Remarks

Connector Unit MOLOC Unit MOLOC

CSi - RTL F:ASN(E) 0 07C123P3 F:ASN(E) 1 05D123P2 Clock connections

RTL F:ASN(E) 0 07C123P2 F:ASN(E) 1 05C123P2

ASC F:ASN(E) 0 07C123R1 External sym. reference clock

ASC F:ASN(E) 1 05C123R1

ASC F:ASN(E) 1 05D123P2 F:ASN(E) 0 07D123P3 Alarming

ASC F:ASN(E) 0 07D123P3 F:ASN(E) 1 05D123P2

ASC F:ASN(E) 0 07D123P5 F:ASN(E) 1 05D123P5 Cross Link ACCG

Tab. 3.24 Cabling F:ASN(E) internal

Cabling F:ASN(E) <---> F:SCB (Connector Rx, Tx)

Connector From F:ASN(E) To F:SCB Remarks


Tx= to SCB
Unit MOLOC Unit MOLOC
Rx= to ASN

R0 F:ASN(E)0 / GMX0 Port 0-3 07C133P3 F:SCB 09C169P5 Basic connection

T0 F:ASN(E)0 / GMX0 Port 0-3 07C133P4 F:SCB 09D169P1

R0 F:ASN(E)1 / GMX0 Port 0-3 05C133P3 F:SCB 09C231P1

T0 F:ASN(E)1 / GMX0 Port 0-3 05C133P4 F:SCB 09D231P2

Tab. 3.25 Cabling F:ASN(E) <---> F:SCB

A50016-D1703-M1-4-7620 61
Construction MP/SP-Platform Maintenance
Node

Cabling F:ASN(E) <---> F:SCE (Connector Rx, Tx)

Connector From F:ASN(E) To F:SCE Remarks


Tx= to SCE
Rx= to ASN

Connector MOLOC Unit Unit

R1/ T1- R3 / T3 07C133 F:ASN(E)0 / GMX0 Port 4-15 F:SCE 1. 2. and 3. additional
connection in GMX0
R1/ T1- R3 / T3 05C133 F:ASN(E)1 / GMX0 Port 4-15 F:SCE

R4/ T4- R7 / T7 07C149 F:ASN(E)0 / GMX0 Port 16-31 F:SCE 4. 5. 6. and 7. additional
connection in GMX0
R4/ T4- R7 / T7 05C149 F:ASN(E)1 / GMX0 Port 16-31 F:SCE

R0/ T0- R3 / T3 07C159 F:ASN(E)0 / GMX1 Port 32-47 F:SCE 1. 2. 3. and 4. additional
connection in GMX1
R0/ T0- R3 / T3 05C159 F:ASN(E)1 / GMX1 Port 32-47 F:SCE

R4/ T4- R7 / T7 07C175 F:ASN(E)0 / GMX1 Port 48-63 F:SCE 4. 5. 6. and 7. additional
connection in GMX1
R4/ T4- R7 / T7 05C175 F:ASN(E)1 / GMX1 Port 48-63 F:SCE

R0/ T0- R3 / T3 07C339 F:ASN(E)0 / GMX2 Port 64-79 F:SCE 1. 2. 3. and 4. additional
connection in GMX2
R0/ T0- R3 / T3 05C339 F:ASN(E)1 / GMX2 Port 64-79 F:SCE

R4/ T4- R7 / T7 07C355 F:ASN(E)0 / GMX2 Port 80-95 F:SCE 4. 5. 6. and 7. additional
connection in GMX2
R4/ T4- R7 / T7 05C355 F:ASN(E)1 / GMX2 Port 80-95 F:SCE

R0/ T0- R3 / T3 07C365 F:ASN(E)0 / GMX3 Port 96-111 F:SCE 1. 2. 3. and 4. additional
connection in GMX3
R0/ T0- R3 / T3 05C365 F:ASN(E)1 / GMX3 Port 96-111 F:SCE

R4/ T4- R7 / T7 07C381 F:ASN(E)0 / GMX3 Port 112-127 F:SCE 4. 5. 6. and 7. additional
connection in GMX3
R4/ T4- R7 / T7 05C381 F:ASN(E)1 / GMX3 Port 112-127 F:SCE

R0/ T0- R3 / T3 07C185 F:ASN(E)0 / GMX4 Port 128-143 F:SCE 1. 2. 3. and 4. additional
connection in GMX4
R0/ T0- R3 / T3 05C185 F:ASN(E)1 / GMX4 Port 128-143 F:SCE

R4/ T4- R7 / T7 07C201 F:ASN(E)0 / GMX4 Port 144-159 F:SCE 4. 5. 6. and 7. additional
connection in GMX4
R4/ T4- R7 / T7 05C201 F:ASN(E)1 / GMX4 Port 144-159 F:SCE

R0/ T0- R3 / T3 07C211 F:ASN(E)0 / GMX5 Port 160-175 F:SCE 1. 2. 3. and 4. additional
connection in GMX5
R0/ T0- R3 / T3 05C211 F:ASN(E)1 / GMX5 Port 160-175 F:SCE

R4/ T4- R7 / T7 07C201 F:ASN(E)0 / GMX5 Port 176-191 F:SCE 4. 5. 6. and 7. additional
connection in GMX5
R4/ T4- R7 / T7 05C201 F:ASN(E)1 / GMX5 Port 176-191 F:SCE

R0/ T0- R3 / T3 07C287 F:ASN(E)0 / GMX6 Port 192-207 F:SCE 1. 2. 3. and 4. additional
connection in GMX6
R0/ T0- R3 / T3 05C287 F:ASN(E)1 / GMX6 Port 192-207 F:SCE

R4/ T4- R7 / T7 07C303 F:ASN(E)0 / GMX6 Port 208-223 F:SCE 4. 5. 6. and 7. additional
connection in GMX6
R4/ T4- R7 / T7 05C303 F:ASN(E)1 / GMX6 Port 208-223 F:SCE

R0/ T0- R3 / T3 07C313 F:ASN(E)0 / GMX7 Port 224-239 F:SCE 1. 2. 3. and 4. additional
connection in GMX7
R0/ T0- R3 / T3 05C313 F:ASN(E)1 / GMX7 Port 224-239 F:SCE

R4/ T4- R7 / T7 07C329 F:ASN(E)0 / GMX7 Port 240-255 F:SCE 4. 5. 6. and 7. additional
connection in GMX7
R4/ T4- R7 / T7 05C329 F:ASN(E)1 / GMX7 Port 240-255 F:SCE

Tab. 3.26 Cabling F:ASN(E) <---> F:SCE

62 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Cabling F:ASN(E) <--> IDF (Connector CSO)

From F:ASN To IDF

Connector Unit MOLOC

CSO F:ASN(E) 1 05C123R1 IDF 18x20 reference clock

CSO F:ASN(E) 0 07C123R1 IDF 18x13 reference clock

Tab. 3.27 F:SCB <---> IDF (Connector CSO)

3.1.4 F:ASN(H) (ASN20 shelf)

3.1.4.1 F:ASN(H) (module side)

D
GMX 1

GMX 1
GMX 0

GMX 2

GMX 3

GMX 0

GMX 2

GMX 3
ASMG

ASMG
ACCG

ACCG
PSAG

PSAG
C269
C251

C287

C355
C225

C373
C207
C191

C303

C339
C103

C121

C139

C155

Modules with displays and switches in F:ASN(H)

ACCG (Q145) (Q1022) ACCG (Q1161) ASMG8/8 (Q1146) ASMG16/16 (Q1034)

GMX:E (Q1032) PSAG (Q6124)

Tab. 3.28 Modules with displays and switches in F:ASN(H)

3.1.4.2 F:ASN(H) (cabling)


for example: C263P1, C263R1
i P is the upper plug within one system unit; R is the lower plug within one system unit;

Cabling F:ASN(H) <----> F:SCB (Connector Bxx, Cxx)


Clock connections

A50016-D1703-M1-4-7620 63
Construction MP/SP-Platform Maintenance
Node

From F:ASN(H) To F:SCB Remarks

Connector Unit MOLOC Unit MOLOC

B21 F:ASN(H) 07C163P1 F:SCB 09C191P5 Clock connections

B80 F:ASN(H) 07C173R1 Ref. Clock sym/COAX

C80 F:ASN(H) 07C321R1 Ref. Clock sym/COAX

B81/ C81 F:ASN(H) 07C173P2 F:ASN(H) 07C321P2 Ref. Clock cross over

B82 F:ASN(H) 07C173R2 F:SCB 09C263P1 Additional ref. clock

C82 F:ASN(H) 07C321R2 F:SCB 09C263R1 Additional ref. clock


B90 F:ASN(H) 07C173R1 F:SCB bas. rack 09C169P1 Clock connections

C90 F:ASN(H) 07C321R1 F:SCB bas. rack 09C251P1 Clock connections

B91 F:ASN(H) 07D173P2 F:SCB ext. rack 1 09C169P1 Clock connections

C91 F:ASN(H) 07D321P2 F:SCB ext. rack 1 09C251P1 Clock connections

B91 F:ASN(H) 07D173P2 F:SCE ext. rack 1 09C241P1 Clock connections


C91 F:ASN(H) 07D321P2 F:SCE ext. rack 1 09C241P2 Clock connections

B92 F:ASN(H) 07D173R2 F:SCE ext. rack 2 09C241P1 Clock connections

C92 F:ASN(H) 07D321R2 F:SCE ext. rack 2 09C241P2 Clock connections

Tab. 3.29 Cabling F:SCB <----> F:ASN(H) (Connector Bxx, Cxx)

Cabling F:ASN(H) internal

From F:ASN(H) To F:SCB Remarks

Connector Unit MOLOC Unit MOLOC

B08 / C08 F:ASN(H) 07C163P2 F:ASN(H) 07C311P1 Alarming

B08 / C08 F:ASN(H) 07C199P2 F:ASN(H) 07C347P2

B81 / C81 F:ASN(H) 07C173P2 F:ASN(H) 07C321P2 Clock connection

Tab. 3.30 Cabling F:ASN(H) internal

Cabling F:ASN(H) <--> F:SCB

Connector From F:ASN(H) To Remarks


Tx= to SCB F:SCB
Rx= to ASN

Connector Unit MOLOC Unit MOLOC

R00 / Plane 0 F:ASN(H) / GMX0 Port 0-3 07C111P3 F:SCB 09C169P5 Basic connections

T00 / Plane 0 F:ASN(H) / GMX0 Port 0-3 07C111P4 F:SCB 09D169P1

R00 / Plane 1 F:ASN(H) / GMX0 Port 0-3 07C259P3 F:SCB 09C231P1

T00 / Plane 1 F:ASN(H) / GMX0 Port 0-3 07C259P4 F:SCB 09D231P2

Tab. 3.31 Cabling F:ASN(H) <---> F:SCB

64 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Cabling F:ASN(H) <---> F:SCE

Connector From F:ASN(H) To Remarks


Tx= to SCE F:SCE
Rx= to ASN

Connector MOLOC Unit Unit

R01/ T01- R03 / T03 07C111 F:ASN(H) / GMX0 Port 4-15 F:SCE 1. 2. and 3. additional
connection in GMX0
R01/ T01- R03 / T03 07C259 F:ASN(H) / GMX0 Port 4-15 F:SCE

R04/ T04- R07 / T07 07C129 F:ASN(H) / GMX0 Port 16-31 F:SCE 4. 5. 6. and 7. additional
connection in GMX0
R04/ T04- R07 / T07 07C277 F:ASN(H) / GMX0 Port 16-31 F:SCE

R08/ T08- R11 / T11 07C147 F:ASN(H) / GMX1 Port 32-47 F:SCE 1. 2. 3. and 4. additional
connection in GMX1
R08/ T08- R11 / T11 07C295 F:ASN(H) / GMX1 Port 32-47 F:SCE

R12/ T12- R15 / T15 07C163 F:ASN(H) / GMX1 Port 48-63 F:SCE 4. 5. 6. and 7. additional
connection in GMX1
R12/ T12- R15 / T15 07C311 F:ASN(H) / GMX1 Port 48-63 F:SCE

R16/ T16- R19 / T19 07C183 F:ASN(H) / GMX2 Port 64-79 F:SCE 1. 2. 3. and 4. additional
connection in GMX2
R16/ T16- R19 / T19 05C331 F:ASN(H) / GMX2 Port 64-79 F:SCE

R20/ T20- R23 / T23 07C199 F:ASN(H) / GMX2 Port 80-95 F:SCE 4. 5. 6. and 7. additional
connection in GMX2
R20/ T20- R23 / T23 05C347 F:ASN(H) / GMX2 Port 80-95 F:SCE

R24/ T24- R27 / T27 07C215 F:ASN(H) / GMX3 Port 96-111 F:SCE 1. 2. 3. and 4. additional
connection in GMX3
R24/ T24- R27 / T27 05C363 F:ASN(H) / GMX3 Port 96-111 F:SCE

R28/ T28- R31 / T31 07C233 F:ASN(H) / GMX3 Port 112-127 F:SCE 4. 5. 6. and 7. additional
connection in GMX3
R28/ T28- R31 / T31 05C381 F:ASN(H) / GMX3 Port 112-127 F:SCE

Tab. 3.32 Cabling F:ASN(H) <---> F:SCE

A50016-D1703-M1-4-7620 65
Construction MP/SP-Platform Maintenance
Node

3.1.5 F:SXCB (ASN5 shelf)

3.1.5.1 F:SXCB (module side)


Side 0 Side 1

ACCG 01
ASMX 00
ACCG 00

MPUE 00
MPUE 01

MPUE 00

MPUE 01

ASMX 01
ALIB 00
MOD 00

MDD 00

MDD 01
LIC 00
LIC 01
C149

C173

C227

C251

C271

C293

C341

C369
C161

C353
C137

C195
C101

C117

Modules with displays and switches in F:SXCB

ACCG (Q145) (Q1022) ALIB (Q1065) ASMX (Q1147)

LIC:2A (Q1014) LIC:1,5A (Q1013) MDD (U107-X100)

MOD (Q1028) MPUE (Q270-X801) MPUE (Q270-X901)

MPUE (Q271-X801) MPUE (Q271-X901) MPUE (Q271-X801)

Tab. 3.33 Modules with displays and switches in F:SXCB

3.1.5.2 F:SXCB (backplane)


CSO CLK2 CSI CSI CSO CLK2
COD FOT ASN FOT FOT ASN 1-0 FC1 FOT ASN FOT 0-0 ASN
P1 RTTL CLK2 4-7 0-3 CSI 4-7 CSI RTTL CLK2
1-1 0-1 0-3
RTTL CLK2 CSI CSI RTTL CLK2
COD ASN ASN 1-2 0-2
P2 FC2 ASN ASN LI LI
CSTI CLK2 4-7 0-3 CSI CSI CSTI CLK2
1-3 4-7 0-3 0-3
ASP ASP ASP ASP
RC FOT LI LI
P3 16-19 0-3 16-19 0-3
C
ASP ASP ASP ASP
P4 L0 LI LI
16-19 0-3 16-19 0-3

ASP ASP PC ASP ASP


P5 L1 LI LI
20-23 4-7 +UE 20-23 4-7
SCSI

SCSI

-UE
ASP ASP ASP ASP
P1 CLK0 YB YB
20-23 4-7 -UE 20-23 4-7

ASP ASP PC ASP ASP


P2 24-27 8-11
CLK1
24-27 8-11
+UE

ASP -UE
D P3 ASP
24-27 8-11 -UE
ASP
24-27
ASP
8-11

P4 ASP ASP X.25 FOT ACIS FOT ACIS FOT LAN ASP ASP
LAN
FOT ACIS ACIS FOT BOS FOT
28-31 12-15 28-31 12-15

P5 ASP ASP ASP ASP


12-15 AL3 CLK LAN CLK BOS
28-31 LAN LAN LAN LAN LAN 28-31 12-15
379

361

341
331
321
311
301
291
281

261

231
221
211
201
191
181
173
161
149
137
127

109

66 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Strapping plugs
Connector COD
C331P1 code plug plane/shelf
C331P2 code plug MP
Connector SCSI
C181P4 SCSI term. MDD/MOD Plane 0
C331P4 SCSI term. MDD/MOD Plane 1

3.1.5.3 F:SXCB (cabling)


for example: C263P1, C263R1
i P is the upper plug within one system unit; R is the lower plug within one system unit;

Cabling F:SXCB internal (Connector ASN 0-3, RTTL/CSTI)

From F:SXCB To F:SXCB

Connector Unit MOLOC Connector Unit MOLOC

ASN 0-3 # F:SXCB 09C181P2 ASP 0-3 F:SXCB 09C109P3


ASN 0-3 # F:SXCB 09C181P1 ASP 0-3 F:SXCB 09C109P4

ASN 0-3 # F:SXCB 09C281P2 ASP 0-3 F:SXCB 09C361P3

ASN 0-3 # F:SXCB 09C281P1 ASP 0-3 F:SxCB 09C361P4

RTTL/CSTI & F:SXCB 09C127P2 RTTL/CSTI F:SxCB 09C379P2

#) Frame internal in F:SXCB MUT 09 of basic rack, if the SXCB internal ASN is used (SXCB as single shelf)

&) ASN in F:SXCB MUT 09 of basic rack, if reference clock from ext. is used

Tab. 3.34 Cabling F:SXCB internal (Connector ASN 0-3, ASP)

Cabling F:SXCB (Connector LI, RTTL) <--> IDF

From F:SXCB To IDF

Connector Unit MOLOC

LI F:SXCB 09C137P2 IDF x001, E1-sym./COAX, DS1-sym

LI F:SXCB 09C137P4 IDF x003, E1-sym./COAX, DS1-sym

RTTL F:SXCB 09C127R1 IDF 19x013, Reference clock COAX

RTTL F:SXCB 09C379R1 IDF 19x020, Reference clock COAX

Tab. 3.35 F:SXCB (Connector LI, RTTL) <---> IDF

A50016-D1703-M1-4-7620 67
Construction MP/SP-Platform Maintenance
Node

Cabling F:SXCB (Connector LAN) <--> Ethernet

From F:SXCB Ethernet interface

Connector Unit MOLOC

LAN F:SXCB 09D259P4 (OAM) from F:SXCB plane 0 to ext. 100BaseT

LAN F:SXCB 09D259P5 (OAM) from F:SXCB plane 1 to ext. 100BaseT

LAN F:SXCB 09D161P5 MPU at C161 in F:SXCB to ext. 100BaseT

LAN F:SXCB 09D171P5 MPU at C173 in F:SXCB to ext. 100BaseT

LAN F:SXCB 09D137P5 MPU at C137 in F:SXCB to ext. 100BaseT


LAN F:SXCB 09D149P5 MPU at C149 in F:SXCB to ext. 100BaseT

Tab. 3.36 F:SXCB (Connector LAN) <---> Ethernet

Cabling F:SXCB (Connector FOT) <----> F:BPCE

From F:SXCB To F:BPCE

Connector Unit MOLOC Connector Unit MOLOC

FOT F:SXCB 09D201W4 5-FOTX F:BPCE 07D209W3

FOT F:SXCB 09D201W5 5-FOTX F:BPCE 07D209W2

FOT F:SXCB 09D231W4 5-FOTX F:BPCE 07D285W3

FOT F:SXCB 09D231W5 5-FOTX F:BPCE 07D285W2

FOT F:SXCB 09D311W4 5-FOTX F:BPCE 07D209W5

FOT F:SXCB 09D311W5 5-FOTX F:BPCE 07D209W4

FOT F:SXCB 09D331W4 5-FOTX F:BPCE 07D285W5

FOT F:SXCB 09D331W5 5-FOTX F:BPCE 07D285W4

Tab. 3.37 F:SXCB (Connector FOT) <----> Cabling F:BPCE

Cabling F:SXCB (Connector FOT) <--> F:MBD

From F:SXCB To F:MBD

Connector Unit MOLOC Connector Unit MOLOC

FOT F:SXCB / AMX0 09C201W2 10 F:MBD0 / MBDA0 C157W1

FOT F:SXCB / AMX0 09C201W1 10 F:MBD0 / MBDA0 C157W2

FOT F:SXCB / AMX0 09C259W4 10 F:MBD1 / MBDA0 C157W1

FOT F:SXCB / AMX0 09C259W3 10 F:MBD1 / MBDA0 C157W2

FOT F:SXCB / AMX1 09C291W2 11 F:MBD0 / MBDA0 C157W3

FOT F:SXCB / AMX1 09C291W1 11 F:MBD0 / MBDA0 C157W4

FOT F:SXCB / AMX1 09C321W2 11 F:MBD1 / MBDA0 C157W3

FOT F:SXCB / AMX1 09C321W1 11 F:MBD1 / MBDA0 C157W4

FOT F:SXCB / AMX0 09C221W2 12 F:MBD0 / MBDA0 C157W5

Tab. 3.38 Cabling F:SXCB (Connector FOT) <--> F:MBD

68 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

From F:SXCB To F:MBD

Connector Unit MOLOC Connector Unit MOLOC

FOT F:SXCB / AMX0 09C221W1 12 F:MBD0 / MBDA0 D157W1

FOT F:SXCB / AMX0 09D181W5 12 F:MBD1 / MBDA0 C157W5

FOT F:SXCB / AMX0 09D181W4 12 F:MBD1 / MBDA0 D157W1

FOT F:SXCB / AMX1 09C301W2 13 F:MBD0 / MBDA0 D157W2

FOT F:SXCB / AMX1 09C301W1 13 F:MBD0 / MBDA0 D157W3

FOT F:SXCB / AMX1 09D291W5 13 F:MBD1 / MBDA0 D157W2


FOT F:SXCB / AMX1 09D291W4 13 F:MBD1 / MBDA0 D157W3

Tab. 3.38 Cabling F:SXCB (Connector FOT) <--> F:MBD

Cabling F:SXCB (Connector CLK2, L1) <----> F:SCE

From F:SXCB To F:SCE Remarks

Connector MOLOC Connector MOLOC

CLK2 09C109R2 5 09C241P1 Clock from F:SXCB bas. rack


to F:SCE in 1. ext. rack
CLK2 09C361R2 5 09C241P2

CLK2 09C109P2 5 03C241P1 Clock from F:SXCB MUT09


to F:SCE MUT03
CLK2 09C361P2 5 03C241P2

CLK2 09C109R1 5 05C241P1 Clock from F:SXCB MUT09


to F:SCE MUT05
CLK2 09C361R1 5 05C241P2

CLK2 09C109P1 5 07C241P1 Clock from F:SXCB MUT09


to F:SCE MUT07
CLK2 09C361P1 5 07C241P2

L1 09C341P5 11 07C241P3 Alarm out

L1 07C341P5 11 05C241P3 Alarm out

Tab. 3.39 Cabling F:SXCB (Connector CLK2, L1, APS) <----> F:SCE

Cabling F:SXCB (Connector APS 4...31) <----> F:SCE

From F:SXCB To F:SCE Remarks

Connector MOLOC Connector MOLOC

ASP 4-7 09C109P5 14 C201P3 1. Additional connection

ASP 4-7 09D109P1 14 C201P4

ASP 4-7 09C361P5 14 C281P3

ASP 4-7 09D361P1 14 C281P4

APS 8-11 09D109P2 14 C201P5 2. Additional connection

APS 8-11 09D109P3 14 D201P1

APS 8-11 09D361P2 14 C281P5

APS 8-11 09D361P3 14 D281P1

Tab. 3.40 Cabling F:SXCB (Connector APS 4...31) <----> F:SCE

A50016-D1703-M1-4-7620 69
Construction MP/SP-Platform Maintenance
Node

From F:SXCB To F:SCE Remarks

Connector MOLOC Connector MOLOC

APS 12-15 09D109P4 14 D201P2 3. Additional connection

APS 12-15 09D109P5 14 D201P3

APS 12-15 09D361P4 14 D281P2

APS 12-15 09D361P5 14 D281P3

ASP 16-19 09C127P3 14 C201P3 4. Additional connection

ASP 16-19 09C127P4 14 C201P4


ASP 16-19 09C379P3 14 C281P3

ASP 16-19 09C379P4 14 C281P4

ASP 20-23 09C127P5 14 C201P5 5. Additional connection

ASP 20-23 09D127P1 14 D201P1

ASP 20-23 09C379P5 14 C281P5

ASP 20-23 09D379P1 14 D281P1


APS 24-27 09D127P2 14 D201P2 6. Additional connection

APS 24-27 09D127P3 14 D201P3

APS 24-27 09D379P2 14 D281P2

APS 24-27 09D379P3 14 D281P3

APS 28-31 09D127P4 14 D201P4 7. Additional connection

APS 28-31 09D127P5 14 D201P5

APS 28-31 09D379P4 14 D281P4

APS 28-31 09D379P5 14 D281P5

Tab. 3.40 Cabling F:SXCB (Connector APS 4...31) <----> F:SCE

Cabling F:SXCB (Connector L0) <----> Breaker panel

From F:SCB To Breaker panel

Connector Unit MOLOC Unit

L0 F:SXCB 09C341P4 ALMC alarm in

Tab. 3.41 Cabling F:SXCB (Connector L0) <----> Breaker panel

Cabling F:SXCB (Connector CSTI, L1) <----> F:ASN(H)

From F:SXCB To F:ASN(H) Remarks

Con- Unit MOLOC Con- Unit MOLOC


nector nector

CSTI F:SXCB 09C127R2 B81 F:ASN(H) 07C173R2 Ref. Clock

CSTI F:SXCB 09C379R2 C92 F:ASN(H) 07D321R2

L1 F:SXCB 09C341P5 B21 F:ASN(H) 07C163P1 Alarm out

Tab. 3.42 Cabling F:SXCB (Connector CSTI, L1) <----> F:ASN(H)

70 A50016-D1703-M1-4-7620
Node
Maintenance

3.1.6

A50016-D1703-M1-4-7620
P5
P4
P3
P1

P5
P4
D P3
P2
P1
P2

C101 ACCG

C117 AMXE

C137 MPU or empty

C149 MPU or empty

C161 MPU or empty

C173 MPU or empty

C195 empty

C227 MDD

C251 OAMD MPU

C271 OAMD MPU

C293 MDD

C309 empty
F:SXCB (ASN5 single shelf with AMXE and MP:OAMD)

C341 empty

ACCG
C353

C369 AMXE

71
Construction MP/SP-Platform
Construction MP/SP-Platform Maintenance
Node

3.2 SPP (Server Processor Platform)

3.2.1 Normal Shelf

PM˚

PM˚

PM˚

PM˚

PM˚

PM˚

PM˚

PM˚

PM˚

PM˚
PM

PM

PM

PM
A
LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

MCP1
PSU1

PSU2
B LIC

10

11
8
4

9
2

7
1

˚ not required for an SP card

Note:
The max. number of an SP card in normal XP140 shelf is limited to e.g. 6 due to
power supply and thermal limitations

3.2.2 HD Shelf
PM˚

PM˚

PM˚

PM˚

PM˚

PM˚

PM˚

PM˚

PM˚
PM

PM

PM

A
LIC (ATM)
LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

LIC or SP

MCP1
PSU1

PSU2

PSU3

B
10

11
2
1

9
7
8
3

˚ not required for an SP card

Note:
The max. number of an SP card in an XP140 HD shelf is limited to e.g. 6 due to
power supply and thermal limitations

72 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

3.3 OEM Devices


3.3.1 AFS (Force PC)
3.3.2 HUB
3.3.3 GPS (Radio Clock)

3.3.1 AFS (Force PC)


Accounting File Server

CD-ROM Drive

Floppy Drive

Fig. 3.1 Force PC, front view

ETH #0

Serial

D B

C A SCSI #2 SCSI #1 ETH #2 ETH #1

Fig. 3.2 Force PC, rear view

A50016-D1703-M1-4-7620 73
Construction MP/SP-Platform Maintenance
Node

3.3.2 HUB

Data
Pwr Start Exp RPS Col
Seg1 Seg2 Seg3 Ispl Hub
Exp

1 3 5 7 9 11
2 4 6 8 10 12

Fig. 3.3 HUB, front view

3.3.3 GPS (Radio Clock)

GPS
GPS

in

1 2 3 4 +

5 6 7 8 -

OCF 9 0 A B BS

C D E F BA

out
N W S Y ENT

Fig. 3.4 Radio clock, front view

74 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

COM 0 COM 1

V.11 V.11

Power Supply
GND PE -48 V
1 2

V.28 V.28

Fig. 3.5 Radio clock, rear view

A50016-D1703-M1-4-7620 75
Construction MP/SP-Platform Maintenance
Node

4 Modules
4.1 Main Processor Platform (MPP)
4.2 Server Processor Platform (SPP)

4.1 Main Processor Platform (MPP)


4.1.1 ACCG (Q145) (Q1022)
4.1.2 ACCG (Q1161)
4.1.3 ALIB (Q1065)
4.1.4 AMXE (Q1019)
4.1.5 ASMX (Q1147)
4.1.6 ASMG8/8 (Q1146)
4.1.7 ASMG16/16 (Q1034)
4.1.8 GMX:E (Q1032)
4.1.9 LIC:1,5A (Q1013)
4.1.10 LIC:1.5A-P (Q1125)
4.1.11 LIC:2A (Q1014)
4.1.12 LIC:155A (Q1018-X1)
4.1.13 LIC:TSC V2 (Q1148-X1)
4.1.14 LIC:2A-P (Q1126-X1)
4.1.15 LIC:155D-P (Q1137-X301)
4.1.16 LIC:155E-P (Q1137-X401)
4.1.17 LIC:155F-P (Q1137-X401)
4.1.18 MDD (U107-X100)
4.1.19 MDD (U2594)
4.1.20 MOD (Q1028)
4.1.21 MPUC (Q80-X401)
4.1.22 MPUC (Q82-X401)
4.1.23 MPUD (Q83-X401)
4.1.24 MPUD (Q83-X801)
4.1.25 MPUD (Q83-X901)
4.1.26 MPUD (Q202)
4.1.27 MPUD (Q208-X801)
4.1.28 MPUD (Q208-X901)
4.1.29 MPUD (Q208) (Q85)
4.1.30 MPUE (Q270-X801)
4.1.31 MPUE (Q270-X901)
4.1.32 MPUE (Q271-X801)
4.1.33 MPUE (Q271-X901)
4.1.34 MPUE (Q272)
4.1.35 MPUE (Q274-X801)
4.1.36 PSAG (Q6124)

76 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.1 ACCG (Q145) (Q1022)

ACCG
ASN Clock Control Generator

RUN ERROR Meaning


ERR ● LED: ERR
on off Normal state, unit active and in oper-
ation
RUN ● LED: RUN
off on Unit faulty or blocked

on on The unit has a partial failure, is being


tested, or the IR bit is set
REP No function
off off Without voltage

flashes off Unit is being loaded

V24 RS232C/V24 Interface

A50016-D1703-M1-4-7620 77
Construction MP/SP-Platform Maintenance
Node

ACCG

Switch position Q1022 Switch position Q145

0
1
1 2 3 4 5

1 2 3 4 5
1
S100
0

Switch position S100


External Reference Clock Q1022 Q145 Q145 Single

1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
Symmetrical Cable 120 Ohm 1 1 1
0 0 0

1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
Coaxial Cable 75 Ohm 1 1 1
0 0 0

78 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.2 ACCG (Q1161)

ACCG
ASN Clock Control Generator

RUN ERR Meaning


ERR ● LED: ERR on off Normal state, unit active and in operation

RUN ● LED: RUN off on Unit faulty or blocked

CLK ● LED: CLK on on Unit has a partial failure, is being tested, or the IR bit is set

DS1 ● LED: DS1 off off Without voltage

flashes off Unit is being loaded


REP No function

CLK Meaning

off Reference clock is created and available

flashing slowly Reference clock is not available


V24 RS232C
flashing quickly Reference clock is locked and/or PLL error.
V24 Interface
on Reference clock not available, locked and/or PLL error.

undefined Warming up phase

DS1 Meaning

off DS1 is error free.

flashing slowly Code violation DS1

flashing quickly Out of frame

on Loss of signal

A50016-D1703-M1-4-7620 79
Construction MP/SP-Platform Maintenance
Node

ACCG

4 3 2 1
1
S1
0

0 1

1
2
3
4
5
S100

Switch position S1
Impedance S1 S1 for reference clock DS1 - 0
S2 for reference clock DS1 - 1
4 3 2 1 S3 and S4 unused
200 Ohm 1
0
4 3 2 1
100 Ohm 1
0

Switch position S100


Impedance S100 S1 and S2 for reference clock 0
S3 and S4 for reference clock 1
1 2 3 4 5 S5 unused
Symmetrical Cable 240 Ohm 1
0
1 2 3 4 5
Symmetrical Cable 120 Ohm 1
0
1 2 3 4 5
Coaxial Cable 75 Ohm 1
0

80 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.3 ALIB (Q1065)

Alarm Line Interface Type B

ALIB
LED LED Meaning

RUN on ERROR off Normal state, unit is active and in operation


ERR ● red LED
RUN ● green LED RUN off ERROR on Unit is faulty or blocked

RUN on ERROR on Unit has a partial failure or is being tested, or the


IR bit is set

RUN off ERROR off Without voltage

RUN flashes ERROR off Unit is being loaded

CR on Critical alarm
Fault in central unit without redundancy
CR ● red LED
MJ on Major alarm
MJ ● red LED
Fault in central units with loss of redundancy
MN ● red LED
MN on Minor alarm
Fault in central units with loss of redundancy

4.1.4 AMXE (Q1019)


AMXE

ATM Multiplexer Type E

ERR ● RUN ERROR Meaning


RUN ●
on off Normal state, unit active and in oper-
ation

off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded

V24 RS232C/V24
Interface

A50016-D1703-M1-4-7620 81
Construction MP/SP-Platform Maintenance
Node

4.1.5 ASMX (Q1147)

ASMX
ATM Switching and Multiplexer Module

ERR ● RUN ERROR Meaning


RUN ● on off Normal state, unit active and in operation

off on Unit faulty

on on Unit has a partial failure, is being tested,


or the IR bit is set

off off Without voltage

flashes off Unit is in locked (available)

4.1.6 ASMG8/8 (Q1146)


ASMG

ATM Switching Core Module G8/8

RUN ERROR Meaning


ERR ●
RUN ●
on off Normal state, unit active and in operation

off on Unit faulty

on on Unit has a partial failure, is being tested,


or the IR bit is set

off off Without voltage

flashes off Unit is in locked (available)

82 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.7 ASMG16/16 (Q1034)

ASMG
ATM Switching Core Module G16/16

RUN ERROR Meaning


ERR ●
RUN ● on off Normal state, unit active and in oper-
ation

off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded

4.1.8 GMX:E (Q1032)


GMXE

Giga Multiplexer Type E

RUN ERROR Meaning


ERR ● on off Normal state, unit active and in oper-
RUN ● ation

off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded

A50016-D1703-M1-4-7620 83
Construction MP/SP-Platform Maintenance
Node

4.1.9 LIC:1,5A (Q1013)

LIC:1,5A
Line Interface Card 5A

RUN ERROR Meaning


ERR ● on off Normal state, unit active and in operation
RUN ● off on Unit faulty or blocked

on on Unit has a partial failure, is being tested,


or the IR bit is set

off off Without voltage

flashes off Unit is being loaded

RS232C/V24
Interface
V24

84 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.10 LIC:1.5A-P (Q1125)

LIC:15AP
Line Interface Card 1.5AP

RUN ERROR Meaning


ERR ●
RUN ● on off Normal state, unit active and in operation

off on Unit faulty or blocked

on on Unit has a partial failure, is being tested,


or the IR bit is set

off off Without voltage

flashes off Unit is being loaded

USB USB Interface

V24
V24 Interface

A50016-D1703-M1-4-7620 85
Construction MP/SP-Platform Maintenance
Node

4.1.11 LIC:2A (Q1014)

LIC:2A
Line Interface Card 2A

RUN ERROR Meaning


ERR l
RUN l on off Normal state, unit active and in oper-
ation

off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded

RS232C/V24
V24 Interface

LIC:2A

1 2 3 4 5 6 7 8
ON 1
OFF 0

Termination 120 Ohm, for twisted pair cables (balanced): Switch OFF
Termination 75 Ohm, for coaxial cables (unbalanced): Switch ON

Switch 1 = Port 7, Switch 2 = Port 6, Switch 3 = Port 5, Switch 4 = Port 4


Switch 5 = Port 3, Switch 6 = Port 2, Switch 7 = Port 1, Switch 8 = Port 0

86 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.12 LIC:155A (Q1018-X1)

LIC: Line Interface Card


155A

RUN ERROR Meaning


ERR on off Normal state, unit active and in oper-
red LED ation
RUN
green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded

RS232C/V24
Interface

4.1.13 LIC:TSC V2 (Q1148-X1)

LIC: TRAU Server Card


TSC V2

RUN ERROR Meaning


ERR on off Normal state, unit active and in oper-
red LED ation
RUN
green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded


USB

D-SUB/V.24
Interface

A50016-D1703-M1-4-7620 87
Construction MP/SP-Platform Maintenance
Node

4.1.14 LIC:2A-P (Q1126-X1)

LIC: Line Interface Card


2A-P

RUN ERROR Meaning


ERR on off Normal state, unit active and in oper-
red LED ation
RUN
green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded


USB

D-SUB/V.24
Interface

LIC:2A-P

ON OFF
0
1
1 2 3 4
5 6 7 8

Termination 120 Ohm, for twisted pair cables (balanced): Switch OFF
Termination 75 Ohm, for coaxial cables (unbalanced): Switch ON

Switch 1 = Port 7, Switch 2 = Port 6, Switch 3 = Port 5, Switch 4 = Port 4


Switch 5 = Port 3, Switch 6 = Port 2, Switch 7 = Port 1, Switch 8 = Port 0

88 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.15 LIC:155D-P (Q1137-X301)

LIC: Line Interface Card


155D-P

RUN ERROR Meaning


ERR on off Normal state, unit active and in oper-
red LED ation
RUN
green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded


USB

D-SUB/V.24
Interface

4.1.16 LIC:155E-P (Q1137-X401)

LIC: Line Interface Card


155E-P

RUN ERROR Meaning


ERR on off Normal state, unit active and in oper-
red LED ation
RUN
green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded


USB

D-SUB/V.24
Interface

A50016-D1703-M1-4-7620 89
Construction MP/SP-Platform Maintenance
Node

4.1.17 LIC:155F-P (Q1137-X401)

LIC: Line Interface Card


155F-P

RUN ERROR Meaning


ERR on off Normal state, unit active and in oper-
red LED ation
RUN
green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being


tested, or the IR bit is set

off off Without voltage

flashes off Unit is being loaded


USB

D-SUB/V.24
Interface

4.1.18 MDD (U107-X100)

Magnetic Disk Device


MDD

ERR

RUN ERROR Meaning
RUN ●
on off Normal state, unit active and in operation

off on Unit faulty or blocked

off off Without voltage

Consisting of: MDD drive (U938)


PC board (Q217)

90 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.19 MDD (U2594)

Magnetic Disk Device

MDD
ERR ●
RUN ●
RUN ERROR Meaning

on off Normal state, unit active and in operation

off on Unit faulty or blocked

off off Without voltage

Consisting of: MDD drive (U938)


PC board (Q217)

4.1.20 MOD (Q1028)

Magnetic Optical Disk Device


MOD

RUN ERROR Meaning


● red LED
on off Normal state, unit active and in operation
● green LED
off on Unit faulty or blocked

off off Without voltage

A50016-D1703-M1-4-7620 91
Construction MP/SP-Platform Maintenance
Node

4.1.21 MPUC (Q80-X401)

Main Processor Unit Type C for Application 512MB

MPUC
RES● Reset switch RUN ERROR Meaning
ERR ● on off Normal state, unit active and in operation
RUN ●
off on Unit faulty or blocked
V24 on on Unit has a partial failure, is being tested, or
the IR bit is set

off off Without voltage


................
................
................
................
................

HWT flashes off Unit is being loaded


HWT for
Hardware Tracer
.......
.......
.......
.......
.......

4.1.22 MPUC (Q82-X401)

Main Processor Unit Type C for Standalone Configuration 512MB


MPUC

RUN ERROR Meaning


Reset switch
RES ●
ERR ● red LED on off Normal state, unit active and in opera-
tion
RUN ● green LED
off on Unit faulty or blocked
V24 on on Unit has a partial failure, is being test-
ed, or the IR bit is set
HWT for
Hardware Tracer off off Without voltage
................
................
................
................
................

HWT
flashes off Unit is being loaded
.......
.......
.......
.......
.......

92 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.23 MPUD (Q83-X401)

Main Processor Unit Type D for 512MB

MPUD
RES ● Reset switch RUN ERROR Meaning
ERR ● on off Normal state, unit active and in operation
RUN ●
off on Unit faulty or blocked
V24 on on Unit has a partial failure, is being tested, or
the IR bit is set

off off Without voltage


................
................
................
................
................

HWT flashes off Unit is being loaded


HWT for
Hardware Trace
.......
.......
.......
.......
.......

4.1.24 MPUD (Q83-X801)

Main Processor Unit Type D for 1GB


MPUD

RES ● Reset switch RUN ERROR Meaning


ERR ● on off Normal state, unit active and in operation
RUN ●
off on Unit faulty or blocked
V24 on on Unit has a partial failure, is being tested, or
the IR bit is set

off off Without voltage


................
................
................
................
................

HWT flashes off Unit is being loaded


HWT for
Hardware Trace
.......
.......
.......
.......
.......

A50016-D1703-M1-4-7620 93
Construction MP/SP-Platform Maintenance
Node

4.1.25 MPUD (Q83-X901)

Main Processor Unit Type D for 2GB

MPUD
RES ● Reset switch RUN ERROR Meaning
ERR ● on off Normal state, unit active and in operation
RUN ●
off on Unit faulty or blocked
V24 on on Unit has a partial failure, is being tested, or
the IR bit is set

off off Without voltage


................
................
................
................
................

HWT flashes off Unit is being loaded


HWT for
Hardware Trace
.......
.......
.......
.......
.......

4.1.26 MPUD (Q208-X801)

Main Processor Unit Type D for Standalone Configuration 1GB


MPUD

RUN ERROR Meaning


Reset switch
RES ●
ERR ● red LED on off Normal state, unit active and in operation
RUN ● green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being tested, or


V24 the IR bit is set

off off Without voltage


HWT for
Hardware Tracer
................
................
................
................
................

flashes off Unit is being loaded


HWT
.......
.......
.......
.......
.......

94 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.27 MPUD (Q208-X901)

Main Processor Unit Type D for Standalone Configuration 2GB

MPUD
RUN ERROR Meaning
Reset switch
RES ●
ERR ● red LED on off Normal state, unit active and in operation
RUN ● green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being tested, or


V24 the IR bit is set

off off Without voltage


HWT for
Hardware Tracer
................
................
................
................
................

flashes off Unit is being loaded


HWT
.......
.......
.......
.......
.......

4.1.28 MPUD (Q202)

Main Processor Unit Type D for Application


MPUD

RES l Reset switch RUN ERROR Meaning


ERR l red LED
on off Normal state, unit active and in oper-
RUN l green LED
ation

off on Unit faulty or blocked


V24
on on Unit has a partial failure, is being
tested, or the IR bit is set
................
................
................
................
................

HWT
off off Without voltage

HWT for flashes off Unit is being loaded


Hardware Trace
.......
.......
.......
.......
.......

A50016-D1703-M1-4-7620 95
Construction MP/SP-Platform Maintenance
Node

4.1.29 MPUD (Q208) (Q85)

Main Processor Unit Type D for Standalone Configuration

MPUD RUN ERROR Meaning


Reset switch
RES l
ERR l red LED on off Normal state, unit active and in oper-
ation
RUN l green LED
off on Unit faulty or blocked
V24 on on Unit has a partial failure, is being
tested, or the IR bit is set
HWT for
Hardware Tracer off off Without voltage
................
................
................
................
................

HWT
flashes off Unit is being loaded
.......
.......
.......
.......
.......

4.1.30 MPUE (Q270-X901)

Main Processor Unit Type E for 2GB


MPUE

RES ● Reset switch RUN ERROR Meaning


ERR ● on off Normal state, unit active and in operation
RUN ●
off on Unit faulty or blocked
V24 on on Unit has a partial failure, is being tested, or
the IR bit is set

off off Without voltage


................
................
................
................
................

HWT flashes off Unit is being loaded


HWT for
Hardware Trace
.......
.......
.......
.......
.......

96 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.31 MPUE (Q270-X801)

Main Processor Unit Type E for 1GB

MPUE
RES ● Reset switch RUN ERROR Meaning
ERR ● on off Normal state, unit active and in operation
RUN ●
off on Unit faulty or blocked
V24 on on Unit has a partial failure, is being tested, or
the IR bit is set

off off Without voltage


................
................
................
................
................

HWT flashes off Unit is being loaded


HWT for
Hardware Trace
.......
.......
.......
.......
.......

4.1.32 MPUE (Q271-X801)

Main Processor Unit Type E for Standalone Configuration 1GB


MPUE

RUN ERROR Meaning


Reset switch
RES ●
ERR ● red LED on off Normal state, unit active and in operation
RUN ● green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being tested, or


V24 the IR bit is set

off off Without voltage


HWT for
Hardware Tracer
................
................
................
................
................

flashes off Unit is being loaded


HWT
.......
.......
.......
.......
.......

A50016-D1703-M1-4-7620 97
Construction MP/SP-Platform Maintenance
Node

4.1.33 MPUE (Q271-X901)

Main Processor Unit Type E for Standalone Configuration 2GB

MPUE RUN ERROR Meaning


Reset switch
RES ●
ERR ● red LED on off Normal state, unit active and in operation
RUN ● green LED off on Unit faulty or blocked

on on Unit has a partial failure, is being tested, or


V24 the IR bit is set

off off Without voltage


HWT for
Hardware Tracer
................
................
................
................
................

flashes off Unit is being loaded


HWT
.......
.......
.......
.......
.......

4.1.34 MPUE (Q272)

Main Processor Unit Type E


MPUE

RES l Reset switch RUN ERROR Meaning


ERR l red LED
on off Normal state, unit active and in oper-
RUN l green LED
ation

off on Unit faulty or blocked


V24
on on Unit has a partial failure, is being
tested, or the IR bit is set
................
................
................
................
................

HWT
off off Without voltage

HWT for flashes off Unit is being loaded


Hardware Trace
.......
.......
.......
.......
.......

98 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.1.35 MPUE (Q274-X801)

Main Processor Unit Type E for 1GB

MPUE
RES ● Reset switch RUN ERROR Meaning
ERR ● on off Normal state, unit active and in operation
RUN ●
off on Unit faulty or blocked
V24 on on Unit has a partial failure, is being tested, or
the IR bit is set

off off Without voltage


................
................
................
................
................

HWT flashes off Unit is being loaded


HWT for
Hardware Trace
.......
.......
.......
.......
.......

4.1.36 PSAG (Q6124)

Power Supply for ASMG


PSAG

RUN ERROR Meaning


ERR ● red LED
on off Normal state, unit active and in operation
RUN ● green LED
off on Unit faulty or blocked

on on Unit has a partial failure, is being tested, or


the IR bit is set

off off Without voltage

flashes off Unit is being loaded

PWR PWR switch

A50016-D1703-M1-4-7620 99
Construction MP/SP-Platform Maintenance
Node

4.2 Server Processor Platform (SPP)


4.2.1 LIC:ETH
4.2.2 LIC:STM1
4.2.3 LIC:CFR
4.2.4 Server Processor (SP)
4.2.5 MCP (Main Control Processor)
4.2.6 PS

i The following table gives you an overview of the individual card and system indications.

Level LED Color Explanation


Card Active Green Indicates that the card is fully operational.
OOS Red Indicates that the card (or one of its components) has
failed BIT testing.
Line Orange Indicates that the card has experienced a line fault
on one or more ports.
System Critical Red Indicates that there is a system fault that can disrupt
traffic to one or more services.
Major Red Indicates that one or more of the service cards is
showing a major alarm.
Minor Orange Indicates that one or more of the service cards is
showing a line fault.

Tab. 4.1 Card and System Indications

100 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.2.1 LIC:ETH
Module

State Condition Explanation

Active

OOS

Line
LAN
Startup Normal On On On During the internal self-test, all LEDs re-
main on for approximately 15 seconds.

Fl On On Indicates that the card is waiting for soft-


(1) ware download to start.

Fl On Off Indicates that software is loading from PC-


MCIA to DRAM. Duration of this stage de-
Ac
t

pends on the size and complexity of the


configuration.
O
O
S

On On Off Indicates that the card is doing BIT testing.

Fl Off Off Indicates that the card is loading current


Li
ne

(1) configuration data from the CDB. Duration


of this stage depends largely on size and
complexity of configuration.

Failure On On On If all LEDs remain lit for more than 15 sec-


onds, there has been a card failure.

Fl On On When LEDs remain in this state perma-


nently, there is a configuration problem in
the MCP. For example:
• mismatch between configured slot and
actual card
• no matching software
• temporary delay in software loading (no
aggregate card or too many simultaneous
loads to cards)

Operating Normal On Off Off Indicates normal operation

Failure Off On Off Indicates card major failure, for example:


• BIT failure
• software failure
LN-E100000
Off Off On Indicates that one or more of the card port
are reporting Line alarms. The most likely
cause is a failure at the physical interface.

Note
(1) Fl means flashing.

Fig. 4.1 ETH 10/100 LAN (S30122-U1029-X)

A50016-D1703-M1-4-7620 101
Construction MP/SP-Platform Maintenance
Node

Personality Module

AUX/LAN

10/100
Base T

10
Base T

IF-R450700

Fig. 4.2 ETH 10/100 LAN PM (S30122-U1030-X)

102 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.2.2 LIC:STM1
Module NIMH

State Condition Explanation

Active

OOS

Line
NIMH
Startup Normal On On On During the internal self-test, all LEDs re-
main on for approximately 15 seconds.

Fl On On Indicates that the card is waiting for soft-


(1) ware download to start.

Fl On Off Indicates that software is loading from PC-


MCIA to DRAM.
Ac
t

On On Off Indicates that the card is doing BIT testing.


O

Fl Off Off Indicates that the card is loading current


O
S

(1) configuration data from the CDB. Duration


of this stage depends largely on size and
Li
ne

complexity of configuration.

Failure On On On If all LEDs remain lit for more than 15 sec-


onds, there has been a card failure.

Fl On On When LEDs remain in this state perma-


nently, there is a configuration problem in
the MCP. For example:
• mismatch between configured slot and
actual card
Mon • no matching software
• temporary delay in software loading (no
aggregate card or too many simultaneous
loads to cards)
Tx
Operating Normal On Off Off Indicates normal operation

Failure Off On Off Indicates card major failure, for example:


• BIT failure
• software failure

Off Off On Indicates one of the following:


• ATM port is reporting a Line alarm
AT-S0100 • clock unit card external source has
failed (2)

Notes
(1) Fl means flashing:
(2) This alarm can occur only when the ATM card is installed in slot 6 or 7 (SP plat-
form).

Fig. 4.3 STM1/OC3

A50016-D1703-M1-4-7620 103
Construction MP/SP-Platform Maintenance
Node

Module STM1/OC3

State Condition Explanation

Active

OOS

Line
2xSTM1/OC3
Startup Normal On On On During the internal self-test, all LEDs re-
main on for approximately 15 seconds.

Fl On On Indicates that the card is waiting for soft-


(1) ware download to start.
Ac
t

Fl On Off Indicates that software is loading from PC-


O

(1) MCIA to DRAM. Duration of this stage de-


O
S

pends largely on size and complexity of


configuration.
Li
ne

On On Off Indicates that the card is doing BIT testing.

Fl Off Off Indicates that the card is loading current


(1) configuration data from the CDB. Duration
1 of this stage depends largely on size and
complexity of configuration.
Tx

Failure On On On If all LEDs remain lit for more than 15 sec-


onds, there has been a card failure.
R
x

Fl On On When LEDs remain in this state perma-


(1) nently, there is a configuration problem in
the MCP. For example:
2 • mismatch between configured slot and
actual card
Tx

• no matching software
• temporary delay in software loading (no
aggregate card or too many simultaneous
R

loads to cards)
x

Operating Normal On Off Off Indicates normal operation

Failure Off On Off Indicates card major failure, for example:


• BIT failure
• software failure

AT-D010080 Off Off On Indicates that one or more of the card


ports are reporting Line alarms. The most
likely cause is a failure at the physical in-
terface.

Note
(1) Fl means flashing:

Fig. 4.4 Dual Port STM Electr (S30122-U1031-X)

104 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

4.2.3 LIC:CFR
Module

State Condition Explanation

Active

OOS

Line
CFR
Startup Normal On On On During the internal self-test, all LEDs re-
main on for approximately 15 seconds.

Fl On On Indicates that the card is waiting for soft-


(1) ware download to start.

Fl On Off Indicates that software is loading from PC-


MCIA to DRAM. Duration of this stage de-
Ac

pends on the size and complexity of the


t

configuration.
O
O

On On Off Indicates that the card is doing BIT testing.


S

Fl Off Off Indicates that the card is loading current


Li

(1) configuration data from the CDB. Duration


ne

of this stage depends largely on size and


complexity of configuration.

Failure On On On If all LEDs remain lit for more than 15 sec-


onds, there has been a card failure.

Fl On On When LEDs remain in this state perma-


(1) nently, there is a configuration problem in
the MCP. For example:
• mismatch between configured slot and
actual card
• no matching software
• temporary delay in software loading (no
aggregate card or too many simultaneous
loads to cards)

Operating Normal On Off Off Indicates normal operation

Failure Off On Off Indicates card major failure, for example:


• BIT failure
• software failure

FR-C010420 Off Off On Indicates that one or more of the card port
are reporting Line alarms. The most likely
cause is a failure at the physical interface.

Note
(1) Fl means flashing:

Fig. 4.5 CFR (S30122-U1023-X)

A50016-D1703-M1-4-7620 105
Construction MP/SP-Platform Maintenance
Node

4.2.4 Server Processor (SP)


Module

BIAS-HP

The LEDs indicate "Active", "Out of Service", and


"Line" fault operational conditions.
See also table in paragraph 4.2.
Ac
t
O
O

Note:
S

After a reset of the SP-GTP card it takes additional 2


minutes before you can use this card
Li
ne

Personality Module
Not required!

Mon

Tx

IP-B200000

Fig. 4.6 BIAS-HP(S32006-Q2020-X401) (S32006-Q2020-X501)

106 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Module

BIAS-FX

The LEDs indicate "Active", "Out of Service", and


"Line" fault operational conditions.
See also table in paragraph 4.2.
Ac
t
O
O
S
Li
ne

IP-B300000

Fig. 4.7 BIAS-FX(S32006-Q2022-X1)

A50016-D1703-M1-4-7620 107
Construction MP/SP-Platform Maintenance
Node

4.2.5 MCP (Main Control Processor)


Module

State Condition Explanation

System Maj

System Min
Card Active

System Crit
Card OOS

Card Line
MCP-S

Startup Normal On On On On On On During the internal self-test, all LEDs remain on for
approximately 30 seconds.

Fl On Off Off Off Off Indicates that software is loading from PCMCIA to
(1) DRAM. Flashes for approximately one minute.

On On Off Off Off Off Exists for 5 seconds only to signal operator when
Ac

rit

to access Configuration mode. If operator does


C
t

not access Configuration mode, boot process con-


tinues.
O
O

aj
S

Fl Off Off Off Off Off Indicates that the configuration is being loaded us-
(1) ing the CDB on the PCMCIA. Duration of this
stage depends largely on size and complexity of
Li
ne

configuration.
in
M

On Off Off Off Off Off Signals end of startup process.


System
MCP

Failure On On On On On On If all LEDs remain lit for more than 30 seconds, in-
dicates either that:
• MCP card has failed
• the PCMCIA card is missing, not formatted or
does not match the platform

Off On Off On Off Off Indicates a faulty MCP card.

Fl Off Off On Off Off When LED condition persists for more than 5 sec-
onds, indicates a missing or invalid IP address.
Try connecting the terminal via serial port for the
Sp-DCE proper configuration.

Fl Off Off On Off Off When LEDs remain in this state permanently, indi-
cates a CDB loading failure.

Operating Normal On Off Off On Off Off Indicates normal operation

Failure Off On Off Off Off Off Indicates that:


or or or • the MCP card is faulty or
On On On • the PCMCIA card is faulty or improperly installed

On Off Off On Off Off Indicates that:


• the network card is missing or has OOS alarm or
CP-00000024 • the power supply has a critical alarm (output
fault)

On Off Off Off On Off Indicates one of the following:


• one or more service cards have OOS alarm
• network card has Line alarm
• power supply has a major alarm (over tempera-
ture or over current

On Off Off Off Off On Indicates one of the following:


• one or more service cards have a Line alarm
• the clock unit card external source has failed
• the selected clock unit reference has failed

Note
(1) Fl means flashing

Fig. 4.8 MCP card

108 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Personality Module

SV

Manual Reset Switch

Discrete Inputs

Discrete Outputs

Alarm Terminals

Aud
Cut Audio Mute Switch

DTE Modem Connector

LAN LAN Management


Interface

SV-R450050

Fig. 4.9 MCP card PM

A50016-D1703-M1-4-7620 109
Construction MP/SP-Platform Maintenance
Node

4.2.6 PS
Module

State Condition Explanation

Active

OOS
PS
Startup Normal On On When you apply current to the PS unit dur-
ing startup, the OOS LED lights approxi-
mately one second, then the Active LED
lights. The Active LED remains on, this in-
dicate normal operation.
ON/OFF Operating Normal On Off Indicates that PS unit is operating normal-
Switch ly and is providing power to cards in the
system shell.

Failure Off On Indicates that module cannot provide pow-


er, because:
• the unit is not receiving input voltage
Active

• the unit protection circuits have been ac-


tivated
• the unit is faulty
0

On On Indicates PS unit’s protection circuits are


faulty. The unit should be serviced.
1.2
3.3
5
OOS

PS-480400

Fig. 4.10 PS140 DC for HD-shelf

110 A50016-D1703-M1-4-7620
Maintenance Construction MP/SP-Platform
Node

Personality Module (not necessary for HD-shelf)

ON/OFF Switch

48 V Common (A3)

-48/-60 V dc (A2)

Chassis
Ground (A1)

Fig. 4.11 PS unit connectors

A50016-D1703-M1-4-7620 111