NOTES
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED.
2. ALL PANELBOARDS AND DISCONNECT SWITCHES ENCLOSURES SHALL BE
GROUNDED INTO ONE GROUNDING CONNECTION POINT OF THE GROUNDING
GRID.
3. MINIMUM WIRE SIZE OF RECEPTACLE OUTLET BRANCH CIRCUITS SHALL BE
4mm² UNLESS OTHERWISE SPECIFIED.
4. MINIMUM CONDUIT SIZE SHALL BE 20mmØ UL-LISTED, SASO APPROVED,
UNLESS OTHERWISE SPECIFIED.
5. FOR LOADS AND WIRE SIZE, REFER TO PANELBOARDS SCHEDULE.
6. THE LOCATION OF DISCONNECT SWITCHES IS ONLY NOTIONAL. THE
CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL DRAWINGS FOR
LOCATION OF AC EQUIPMENT UNITS.
7. DO NOT SCALE FROM THIS DRAWING.
8. ALL DIMENSIONS TO BE CHECKED ON SITE AND ANY DISCREPANCIES SHALL
BE REPORTED IMMEDIATELY TO THE ARCHITECT.
LPPMS 9. CONTRACTOR SHALL VERIFY ALL LEVELS AT SITE PRIOR TO EXECUTION OF
1 1 WORK AND IN CASE OF ANY DISCREPANCIES, BRING TO KNOWLEDGE OF THE
ENGINEER.
10. THE CONTRACTOR SHALL CONFIRM THE SETTING OUT OF THE BUILDING
PRIOR TO COMMENCEMENT OF WORK.
11. THE CONTRACTOR SHALL OBTAIN ALL APPROVALS AND N.O.C.'S FROM ALL
CONCERNED LOCAL STATUTORY AUTHORITIES AND SHALL INCLUDE FOR ALL
LPPMS-14,16,18 WORKS WITH RESPECT TO THE DIVERSION/PROTECTION OF THE SERVICES
LPPMS-8,10,12 LPPMS-14,16,18 DURING THE PERIOD OF CONSTRUCTION, TO THE SATISFACTION OF THE
VIA CP-LPPMS VIA CP-LPPMS
VIA CP-LPPMS CONCERNED AUTHORITIES AND THE ENGINEER.
12. THE CONTRACTOR TO PREPARED SHOP DRAWINGS.
DS DS DS SYMBOL DESCRIPTION
DIS. SWITCH, 30A,
DIS. SWITCH, 30A, DIS. SWITCH, 30A, 600V, NEMA 3R, FOR ROOF EXHAUST FAN, 3-Ph, 400V, 60Hz.
600V, NEMA 3R, FOR 600V, NEMA 3R, FOR REF
ROOF EXHAUST FAN
2 ROOF EXHAUST FAN ROOF EXHAUST FAN 3Ø, 230V 2 CONDUIT EMBEDDED ON WALLS AND FLOORS OR UNDER
GROUND, PVC PIPE 20mmØ MINIMUM NOMINAL DIAMETER.
3Ø, 230V 3Ø, 230V LPPG-A-3 BRANCH CIRCUIT HOMERUN, LPPG-A DENOTES PANEL NAME, 3
DENOTES CIRCUIT NUMBER.
LPP G - 3
CIRCUIT NUMBER
DS DS DS FLOOR LEVEL
PANEL BOARD NAME
CIRCUIT HOME RUN
LPPMS-2,4,6 TO PANEL BOARD
LPPMS-8,10,12 LPPMS-2,4,6
VIA CP-LPPMS LINE OR PHASE WIRE
DIS. SWITCH, 30A,
VIA CP-LPPMS VIA CP-LPPMS NEUTRAL WIRE
4 4
BIA
K IN
G
RA
D
M A
O
O F S A U DI
A B C D E F G H I J TANAGHOM CONSULTING
LIC. NO. 2013,P.O BOX: 9021 / CODE: 35811-4692 JUBAIL IND. CITY -
OFFICE NO. 2-12, NABA COMMERCIAL CENTER, AL-FANATEER-/
TEL-/(03) 3472261 / 3473926 / 3473950 //FAX: (03) 3472259/
Website:www.tanaghomconsulting.com
3 - 07 - 41J - B08A J 02 14
ANT-21-008-INK-SPCC-R.0
ANT-21-008-SD-GPP-EL-LA-0005-Rev.01
ANT-21-008-SD-GPP-EL-0094-Rev.01
1: 75M 5/7