1.NABROJITE NAMOTE SINKRONOG GENERATORA I SAŽETO OBJASNITE NJIHOVU ULOGU.

UZBUDNI NAMOT NAJČEŠDE SE UGRAĐUJE U ROTOR.KROZ NJEGA SE PROPUŠTA ISTOSMJERNA STRUJA,TAKO DA


SVOJIM PROTJECANJEM STVARA MAGNETSKO POLJE U GENERATORU PRIJEKO POTREBNO ZA ELEKTROMAGNETSKU
PRETVORBU.ARMATURNI NAMOT JE ONAJ PREKO KOJEGA SE PRENOSI UKUPNA SNAGA STROJA,PA SE PRI IZRADBI
NJEMU POKLANJA VELIKA PAŽNJA.ZBOG VELIKIH STRUJA I VISOKIH NAPONA NAJPOGODNIJE JE DA SE ARMATURNI
NAMOT UGRAĐUJE U STATOR.PRIGUŠNI NAMOT ILI KAVEZ UGRAĐUJE SE NAJČEŠDE U ROTOR SINKRONIH
GENERATORA KOJI IMAJU LAMELIRANI ROTOR ILI SAMO LAMELIRANO POLNO STOPALO.AKO SE OČEKUJE IZRAZITIJE
NESIMETRIČNO OPTEREDENJE,PRIGUŠNI SE NAMOT UGRAĐUJE U TURBINSKE GENERATORE KOJIMA JE TIJELO
ROTORA IZRAĐENO OD MASIVNOG ČELIKA.
2.ŠTO JE SINKRONA REAKTANCIJA?
SINKRONA REAKTANCIJA JE ZBROJ REAKCIJE ARMATURE Xa I RASIPNE REAKTANCIJE Xδ.REAKTANCIJE SINKRONOG
GENERATORA UZ SNAGU I NAPON IMAJU ODLUČUJUDI UTJECAJ PRI PRORAČUNIMA. Xs=Xa+Xδ.POČETNA JE
REAKTANCIJA VAŽNA U PRORAČUNU MAKSIMALNE STRUJE KRATKOG SPOJA,A PRIJELAZNA I SINKRONA PRI
PRORAČUNU TRAJNE STRUJE KRATKOG SPOJA PRI PRORAČUNU STATIČKE I DINAMIČKE STABILNOSTI.
3.SKICIRAJTE POJEDNOSTAVNJENU POGONSKU KARTU SINKRONOG
GENERATORA. Str 164
1-MAKSIMALNA DJELATNA SNAGA OGRANIČENA POGONSKIM
STROJEM,2-MINIMALNA DJELATNA SNAGA OGRANIČENA
POGONSKIM STROJEM,3-GRANICA PO MAKSIMALNOJ
ARMATURNOJ STRUJI ZBOG PREGRIJAVANJA ARMATURNOG
NAMOTA SINKRONOG GENERATORA.SINKRONI GENERATORI
NAPAJAJU ELEKTRIČNA TROŠILA DJELATNOM I JALOVOM
SNAGOM.TO SE REDOVITO PREDSTAVLJA DIJAGRAMOM SNAGE S
UCRTANIM OGRANIČENJIMA DOPUŠTENOG TRAJNOG RADA tj.
POGONSKOM KARTOM

4.ŠTO JE VANJSKA ,A ŠTO REGULACIJSKA KARAKTERISTIKA SINKRONOG GENERATORA?


DJELOVANJE REAKCIJE ARMATURE PRI OPTEREDENJU SINKRONOG GENERATORA OVISI O VRSTI
OPTEREDENJA.OVISNOST NAPONA STEZALJKA O STRUJI OPTEREDENJA U=f(Ia) PRI KONSTANTNOJ STRUJI UZBUDE I
FAKTORU SNAGE DEFINIRA VANJSKU KARAKTERISTIKU SINKRONOG GENERATORA. BUDUDI DA SINKRONI
GENERATOR MORA OSIGURATI TROŠILU KONSTANTNI NAPON PRI SVIM OPTEREDENJIMA,POTREBNO JE
PROMJENOM UZBUDNE STRUJE MIJENJATI GLAVNI MAGNETSKI TOK TAKO DA SE INDUCIRA UPRAVO TAKAV NAPON
KOJI DE DAVATI KONSTANTNI NAPON STEZALJKA.POTREBNA UZBUDNA STRUJA ZA RAZNE VRIJEDNOSTI STRUJE
OPTEREDENJA I RAZLIČITE FAKTORE SNAGE I KONSTANTNI NAPON STEZALJKI MOŽE SE ODREDITI RAČUNSKI,GRAFIČKI
ILI MJERENJEM.TU OVISNOST POKAZUJU REGULACIJSKE KARAKTERISTIKE.
5.KOJE JE UVJETE POTREBNO POSTIDI DA BI SINKRONI GENERATORI RADILI PARALELNO?
1.JEDNAKE IZNOSE NAPONA GENERATORA I MREŽNOG NAPONA Eg=U 2.JEDNAKE FREKVENCIJE NAPONA
GENERATORA I MREŽNOG NAPONA.fG=f 3.JEDNAKE KUTOVE NAPONA GENERATORA I MREŽE φG=φ 4.ISTI
REDOSLIJED FAZA GENERATORA I MREŽE