1.NABROJITE NAMOTE SINKRONOG GENERATORA I SAŽETO OBJASNITE NJIHOVU ULOGU.
UZBUDNI NAMOT NAJČEŠDE SE UGRAĐUJE U ROTOR.KROZ NJEGA SE PROPUŠTA ISTOSMJERNA STRUJA,TAKO DA
SVOJIM PROTJECANJEM STVARA MAGNETSKO POLJE U GENERATORU PRIJEKO POTREBNO ZA ELEKTROMAGNETSKU PRETVORBU.ARMATURNI NAMOT JE ONAJ PREKO KOJEGA SE PRENOSI UKUPNA SNAGA STROJA,PA SE PRI IZRADBI NJEMU POKLANJA VELIKA PAŽNJA.ZBOG VELIKIH STRUJA I VISOKIH NAPONA NAJPOGODNIJE JE DA SE ARMATURNI NAMOT UGRAĐUJE U STATOR.PRIGUŠNI NAMOT ILI KAVEZ UGRAĐUJE SE NAJČEŠDE U ROTOR SINKRONIH GENERATORA KOJI IMAJU LAMELIRANI ROTOR ILI SAMO LAMELIRANO POLNO STOPALO.AKO SE OČEKUJE IZRAZITIJE NESIMETRIČNO OPTEREDENJE,PRIGUŠNI SE NAMOT UGRAĐUJE U TURBINSKE GENERATORE KOJIMA JE TIJELO ROTORA IZRAĐENO OD MASIVNOG ČELIKA. 2.ŠTO JE SINKRONA REAKTANCIJA? SINKRONA REAKTANCIJA JE ZBROJ REAKCIJE ARMATURE Xa I RASIPNE REAKTANCIJE Xδ.REAKTANCIJE SINKRONOG GENERATORA UZ SNAGU I NAPON IMAJU ODLUČUJUDI UTJECAJ PRI PRORAČUNIMA. Xs=Xa+Xδ.POČETNA JE REAKTANCIJA VAŽNA U PRORAČUNU MAKSIMALNE STRUJE KRATKOG SPOJA,A PRIJELAZNA I SINKRONA PRI PRORAČUNU TRAJNE STRUJE KRATKOG SPOJA PRI PRORAČUNU STATIČKE I DINAMIČKE STABILNOSTI. 3.SKICIRAJTE POJEDNOSTAVNJENU POGONSKU KARTU SINKRONOG GENERATORA. Str 164 1-MAKSIMALNA DJELATNA SNAGA OGRANIČENA POGONSKIM STROJEM,2-MINIMALNA DJELATNA SNAGA OGRANIČENA POGONSKIM STROJEM,3-GRANICA PO MAKSIMALNOJ ARMATURNOJ STRUJI ZBOG PREGRIJAVANJA ARMATURNOG NAMOTA SINKRONOG GENERATORA.SINKRONI GENERATORI NAPAJAJU ELEKTRIČNA TROŠILA DJELATNOM I JALOVOM SNAGOM.TO SE REDOVITO PREDSTAVLJA DIJAGRAMOM SNAGE S UCRTANIM OGRANIČENJIMA DOPUŠTENOG TRAJNOG RADA tj. POGONSKOM KARTOM
4.ŠTO JE VANJSKA ,A ŠTO REGULACIJSKA KARAKTERISTIKA SINKRONOG GENERATORA?
DJELOVANJE REAKCIJE ARMATURE PRI OPTEREDENJU SINKRONOG GENERATORA OVISI O VRSTI OPTEREDENJA.OVISNOST NAPONA STEZALJKA O STRUJI OPTEREDENJA U=f(Ia) PRI KONSTANTNOJ STRUJI UZBUDE I FAKTORU SNAGE DEFINIRA VANJSKU KARAKTERISTIKU SINKRONOG GENERATORA. BUDUDI DA SINKRONI GENERATOR MORA OSIGURATI TROŠILU KONSTANTNI NAPON PRI SVIM OPTEREDENJIMA,POTREBNO JE PROMJENOM UZBUDNE STRUJE MIJENJATI GLAVNI MAGNETSKI TOK TAKO DA SE INDUCIRA UPRAVO TAKAV NAPON KOJI DE DAVATI KONSTANTNI NAPON STEZALJKA.POTREBNA UZBUDNA STRUJA ZA RAZNE VRIJEDNOSTI STRUJE OPTEREDENJA I RAZLIČITE FAKTORE SNAGE I KONSTANTNI NAPON STEZALJKI MOŽE SE ODREDITI RAČUNSKI,GRAFIČKI ILI MJERENJEM.TU OVISNOST POKAZUJU REGULACIJSKE KARAKTERISTIKE. 5.KOJE JE UVJETE POTREBNO POSTIDI DA BI SINKRONI GENERATORI RADILI PARALELNO? 1.JEDNAKE IZNOSE NAPONA GENERATORA I MREŽNOG NAPONA Eg=U 2.JEDNAKE FREKVENCIJE NAPONA GENERATORA I MREŽNOG NAPONA.fG=f 3.JEDNAKE KUTOVE NAPONA GENERATORA I MREŽE φG=φ 4.ISTI REDOSLIJED FAZA GENERATORA I MREŽE