Professional Documents
Culture Documents
Design Parameters
1. Runoff Estimate based on Rational Method; q = CIA / 360
2. Return Period = 1 : 15 year for Surface and Sub-surface drainage system
3. Runoff coefficient; C = 0.90 for paved areas, 0.90 for buildings and 0.60 for gravel fill areas.
4. Rainfall intensity based on NAIA RIDF for 15 yr storm event;
5. Time of Concentration; tc = Inlet time + Time of flow in the drain ( Inlet time = 10 minutes )
6. For catchment area ( Ac ) refer to Annex A
7. Drainage pipe capacity is based on Manning's Equation; Q = Ac x 1/n x R2/3 x S1/2
8. Manning's n - Value = 0.013
9. Minimum pipe diameter; D = 300mmØ for Surface drainage lined and 150mmØ for subsurface drainage lined
OUTFALL - 4
CB-20 MH-87 0.049 0.90 0.044 1.200 1.000 10.00 219.60 0.032 0.0050 1 - 300 0.068 1.10 0.02 1.305 1.300 2.774 2.400 47.73 SAFE
CB-21 MH-88 0.072 0.90 0.065 1.200 15.000 10.00 219.60 0.047 0.0050 1 - 300 0.068 1.10 0.23 1.267 1.192 2.217 2.730 70.13 SAFE
CB-22 MH-89 0.020 0.90 0.018 1.200 15.000 10.00 219.60 0.013 0.0050 1 - 300 0.068 1.10 0.23 1.418 1.343 2.368 2.519 19.48 SAFE
CB-23 MH-91 0.020 0.90 0.036 1.200 14.000 10.00 219.60 0.026 0.0050 1 - 300 0.068 1.10 0.21 1.310 1.240 2.260 2.420 38.96 SAFE
MH-87 MH-88 0.038 0.90 0.034 1.200 42.000 10.00 219.60 0.025 0.0040 1 - 300 0.060 0.99 0.71 1.2950 1.127 2.400 2.730 41.38 SAFE
MH-88 MH-89 0.020 0.90 0.052 1.200 27.000 10.00 219.60 0.038 0.0040 1 - 300 0.060 0.99 0.46 1.1220 1.014 2.730 2.519 63.16 SAFE
MH-89 MH-90 0.008 0.90 0.059 1.200 12.500 10.00 219.60 0.043 0.0040 1 - 300 0.060 0.99 0.21 1.0090 0.959 2.519 2.440 71.87 SAFE
MH-90 MH-91 0.011 0.90 0.069 1.200 12.000 10.00 219.60 0.051 0.0040 1 - 300 0.060 0.99 0.20 0.9540 0.906 2.440 2.420 83.85 SAFE
MH-91 OF-4 0.014 0.90 0.082 1.200 5.500 10.00 219.60 0.060 0.0040 1 - 300 0.060 0.99 0.09 0.9010 0.879 2.420 2.400 99.09 SAFE