You are on page 1of 6

Object : kamar Abi

Installation : kamar Abi


Project number : Abi
Date : 28.05.2023

1 Room 1
1.1 Description, Room 1
1.1.1 Floor plan

y [m]
4.0

3.5

3.0

2.5

2.0

1.5

1.0

0.5

0.0

-0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 x [m]

Room data: Reflectance:


W1 : 4.00 50.0 %
W2 : 4.00 50.0 %
W3 : 4.00 50.0 %
W4 : 4.00 50.0 %
W5 : ----- -----
W6 : ----- -----
Floor: ----- 83.1 %
Ceiling: ----- 70.0 %
Room height [m]: 2.80
Height of ref. plane [m]: 0.75

-please put your own address here-


Object : kamar Abi
Installation : kamar Abi
Project : Abi
number Date :

1.2 Summary, Room 1


1.2.2 Result overview, Evaluation area 1

-0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 x [m]

0 0.10.150.2 0.3 0.50.75 1 1.5 2 3 5 7.5 10 15 20 30 50 75 100150200300500750100015020003000500070500


Illuminance [lx]

General
Calculation algorithm used Average indirect fraction

Evaluation area 1 Reference plane 1.1


Horizontal cylindrical
E̅ m 260 lx 212 lx
Emin 73 lx 66 lx
Emin/E̅ m (Uo) 0.28 0.31
Emin/Emax (Ud) 0.06
Ez/Eh 1.12
Position 0.75 m 1.20 m

Major surfaces E̅ m Uo
M 1.5 (Ceiling) 174 lx 0.39
M 1.1 (Wall) 107 lx 0.58
M 1.2 (Wall) 120 lx 0.70
M 1.3 (Wall) 143 lx 0.65
M 1.4 (Wall) 275 lx 0.25

-please put your own address here-


Object : kamar Abi
Installation : kamar Abi
Project : Abi
number Date :

1 Room 1
1.3 Calculation results, Room 1
1.3.1 Table, Reference plane 1.1 (E)

[m]
2.75 103 108 109 102 95 83 (73)
2.25 133 135 133 121 107 94 82

1.75 185 185 171 151 128 108 91


264 265 239 198 162 122 96
1.25
425 410 350 267 188 136 100
0.75
711 686 537 349 210 137 96
0.25
[1310] 1260 866 430 210 124 82
0.25 0.75 1.25 1.75 2.25 2.75
[m]
Illuminance [lx]

Height reference plane : 0.75 m


Average illuminance E̅ m : 260 lx
Minimum illuminance Emin : 73 lx
Maximum illuminance Emax : 1310 lx
Uniformity Uo Emin/E̅ m : 1 : 3.54 (0.28)
Diversity Ud Emin/Emax : 1 : 17.82 (0.06)
Date, Time : 21.03. 10:28 (TST 09:51)

-please put your own address here-


Object : kamar Abi
Installation : kamar Abi
Project : Abi
number Date :

1.3 Calculation results, Room 1


1.3.16 3D luminance, View from the

-please put your own address here-


Object : kamar Abi
Installation : kamar Abi
Project : Abi
number Date :

1.3 Calculation results, Room 1


1.3.17 3D luminance, View from the

-please put your own address here-


Object : kamar Abi
Installation : kamar Abi
Project : Abi
number Date :

1.3 Calculation results, Room 1


1.3.18 3D luminance, View from the

-please put your own address here-