Mechanical Design
2 Mechanical Design
The mechanical design of the Service Tool is shown in Flgure 2-
1.
The Tool is connected to the LCB_II over a RS 422 serial communication line.
MCS-LCB_II 调试方法
MCS-LCB_II
Service Tool Manual
7 7 7
ENTER
GO BACK
Shift key
www.escalatorparts.cn
3
——————————————————————
Tree Structure
3 Tree Structure
All Service tool functions are organized under the tree –structure – structure
Which you can see in Figure 3-1.
It is divided in a SYSTEM path ,where you have access to the main service
Tool functions – STATUS (system monitoring)
- TEST (event monitoring tests) and
- SETUP(setup of system environment),and in a TOOLS path.
The TOOLS pass contains the Service Tool functions which supports installation and maintenance of the
elevator.
LCB_II - Menu
Search IO
Cmd ELD
www.escalatorparts.cn
4
——————————————————————
Menu System
4 LCB_II Menu System
4.1 OVERVIEW
The Menu System allows you to access the single Server Tool functions if you choosethe
right path through the Tree-Structure by pressing the displayed key.(number 1,2,3… 8)
If there is only one number to choose .you can call the function also with the Shift Key
‘ENTER’.
You can toggle between the different Menus using the „GO ON‟ or „GO BACK‟ key if
the „>‟character indicates a hidden menu.
www.escalatorparts.cn
Power on
SELF TEST
- OK - MECS - MODE
M M
LCB_II - Menu
System=1 Tools=2
1 2
S
STATUS – Menu > TEST – Menu > SETUP – Menu >
Calls = 1 Input = 2 Events = 1 Diag = 2 Install =1 RSL = 2
STATUS – Menu > TEST – Menu > SETUP – Menu >
Output = 3 Group = 4 Part = 3 RSL = 4 Allowed = 3 POS = 4
STATUS – Menu > TEST – Menu > SETUP – Menu >
ICSS = 5 Cmd = 6 Selft = 5 DCS – RUN = 5 ELD=6
1 2
www.escalatorparts.cn
4.1.1 System Path
M LCB_II - Menu
(15)
1 2
1 2 3
S Status - Menu
(28)
Test - Menu
(37) (37)
Setup - Menu
(47)
1 Calls
(31)
1 Event
(38) 1 Install - Menu
6 Cmd 5 Doors
(36a)
6 Position Ref.
7 Cargo
8 Emergency
9 Security
Go on Test
(转下页)
www.escalatorparts.cn
2 RSL
(50)
1 Enable
2 Cut Call
M LCB_II - Menu
1 2
1 Search IO
S
2 Erase
Legend:
3 Setup INST
1 Service Tool Key Menu System
4 Opr. Memory
www.escalatorparts.cn
4.2 LCB_II – Menus
4.2.1 Power On
SELF TEST M
- OK – MECS - MODE
4.2.2 LCB_II - Menu After Power On the Service Tool software runs an internal selftest.
Key Sequence M
1 2
LCB_II - Menu
System=1 Tools=2 2 1
Go
on
M
Figure 4 - 5
LCB_II – Menu / Keys
www.escalatorparts.cn
Key 1: transition to the SYSTEM – Menu
1 Key2 : transition to the TOOLS – Menu
2
Go
on
Go Key GO ON :displays the current
on
<toggle key> stop signal(s) LCB_II – Menu
(GO BACK) Stop on : U / DIS
www.escalatorparts.cn
4.2.3 SYSTEM - Menu
M-1
Key Sequence
1 2 3
clear
- Key CLEAR: back to LCB_II – Menu
(one step back)
www.escalatorparts.cn
4.2.4 STATUS – Menu
M–1–1
Key Sequence
1
5
goon
STATUS – Menu > goon
Call = 1 Input = 2
(go back)
M F clear
www.escalatorparts.cn
4.2.5 TEST – Menu
M–1–2
Key Sequence
1
5
www.escalatorparts.cn
4.2.6 SETUP - Menu
M–1–3
Key Sequence
1
5
goon goon
SETUP – Menu >
Install = 1 RSL = 2
(GOBACK)
M F clear
Figure 4 – 9:SETUP – Menu / Keys
www.escalatorparts.cn
4.2.7 Install - Menu
M–1–3-1
Key Sequence
1 clear
9
…
1 clear - Key … Key 9: Call of the Service Tool function INSTALL –SYSTEM
… Install – Security.(Please call Install – Test with Key ENTER)
9 - Shift Key ENTER: Call of the displayed Service Tool function.
…
(ENTER)
goon
- Key GOON / Shift Key GOBACK:
Toggle through INSTALL - Menu
goon
notice : („>‟indicates Menu – Toggle)
(GOBACK)
S
- Key SET: back to SETUP – Menu (level S)
www.escalatorparts.cn
4.2.8 ALLOWED – Menu M–1–3-3
Key sequence
1 clear
3
(ENTER)
ALLOWED – Menu >
01 Enable goon goon
(GOBACK)
www.escalatorparts.cn
4.2.9 TOOLS – Menu M-2
Key sequence
1 clear
9
(ENTER)
TOOLS – Menu >
1= Search IO goon goon
(GOBACK)
M clear
Figure 4 – 12:TOOLS – Menu / Keys
clear - Shift Key ENTER: Calls the displayed Service Tool function.
(ENTER)
goon
goon - Key GOON / Shift Key GOBACK:
Toggle through TOOLS - Menu TOOLS – Menu >
notice: („>‟indicates Menu – Toggle). 02 = Erase IO
(GOBACK)
www.escalatorparts.cn
4.3 Short Keys S4 – S9
Short Keys
The Short Keys provide direct access to certain, often used Service
Tool functions, eliminating the need to step through the menu struc-
ture.
The Service Tool functions Input, Call, Install, Alter and Events
are assigned to the Standard Short Keys S7 (Shift 7),S8 (Shift 8),S4
(Shift 4),S5 (Shift 5)and S6 (Shift 6).
LCB_II Menu
System = 1 Tools = 2
7 8 9
DISP ENT TEST
STATE CALL
7 8 9
M
4 5 6
DISPIN SELout
F 4 5 6
1 2 3
S 1 2 3
www.escalatorparts.cn
4.3.1 Standard Short Keys
LCB_II - Menu
Search IO
STATES - Menu TEST - Menu SETUP - Menu
Erase IO
Figure 4 – 14: Standard Short Keys S4, S5, S7, S8 and S9.
Example:
(S8)
A – 00 IDL ST ] [ ] [
-----------------------------------------
u d l ux
-----------------------------------------
www.escalatorparts.cn
4.3.2 Programmable Short Key S9 Short Key
PROG S9
LCB_II - Menu
Search IO
STATES - Menu TEST - Menu SETUP - Menu
Erase IO
www.escalatorparts.cn
Example
- Short Key S9: Position STATUS / Output is set to the Short Key
9 S9 function
(S9)
- Key MODULE and Shift Key ON:
1 The status of Store Key S9 is dis-
M played on the LCB_II – Menu. LCB_II - Menu
SVT – Key PROG : on
(ON)
notice :
9 - Short Key S9 and LCB_II – Menu:
Reset of Short Key S9.
LCB_II – Menu
SVT – Key – PROG : off
(S9)
(S9)
www.escalatorparts.cn
5
——————————————————————
Service Tool Functions
All the Service Tool functions are divided into 4 groups, the STATUS,
TEST, and SETUP and Tools functions.
LCB_II – Menu
System = 1 Tools = 2
www.escalatorparts.cn
5.1 STATUS – Functions *************
Key Sequence
M–1–1
1 6
2 3 4 5
A-00 IDL ST ] [ ] A-00 IDL ST ] [ ][
[ C> U00D00 A 1C ?:CLD1 ?:CLD2
C> U00D00 A 1 C
------------------------------
Please find in chapter 5.1.1 the exact description of
The Software Status Display (Row one)
www.escalatorparts.cn
5.1.1 Software Status Display
Direction Description
Position Description
00 actual level (level 0)
** position not defined
A – 00 IDL ST ] [ ]
[ C> U00D00 A 1C
www.escalatorparts.cn
Event Messages in Status Display
Event Message
>TCI – LOCK ! Leave Top of Car „ function on
>LS-FAULT ! 1LS / 2LS check negative
A – 00 > TCI – LOCK ! >start DCS ! Door Check Sequence not opr. yet
C> U00D00 A 1C >ACS is on ! Anti Creeping Switch is operated
>1LS + 2LS ! 1LS and 2LS is operated
www.escalatorparts.cn
4.1.2 Call – Function
M–1–1-1
Key Sequence
Enter a call
1) 2)
Calls Call Type / Level Number
1) C Car Call
U Up Hall Call
A u 00 NOR FR ] [ ] D Down Hall Call
[ C>02 U00D00 A 1C E Emergency Hospital Call
goon
goon - Key GOON / Shift Key GOBACK : Toggle trough the Call Types
C–U–D–E
(GOBACK)
clear
2 - Key number for desired level (2)
- Shift Key ENTER: Termination to enter the desired (type, level)
(ENTER) call
www.escalatorparts.cn
1) 2)
Call Demands
Load Status
A ANS load
A u 00 NOR FR ] [ ]
F full load
[ C> U01D00 A 1C
P peak load
O overload
D default load
Power Supply
C Normal power supply
E Emergency power supply
A u 00 NOR FR ] [ ]
[ C> U01 D00 A 1C
www.escalatorparts.cn
4.1.3 Input – Function M–1–1–2
Key Sequence
A – 00 IDL ST ] [ ] [
ins es dw DFC The first row display the Software Status
(see: 5.1.1).
- Lower case letters of the input name stands for „Function = OFF‟ and upper case letters for „function
= ON‟
- Up to four signals are displayed in one row .you can skip to the next / previous group with Key GOON
/ GOBACK.
- Each group is assigned to a functional block. Both can be displayed with Shift Key ENTER.
Please refer to the list of available System Inputs.
(see document: Service Tool Reference List)
goon
- Key GOON / Shift Key GOBACK:
goon
Skip to the next / previous group of the System Inputs.
(GOBACK)
A – 00 IDL ST ] [ ] [
md aes
www.escalatorparts.cn
5.1.4 Output - Function M–1–1-4
Key Sequence
Figure 5-7:Group – Function The second row displays the Software Status of one
of the other Controllers in the group.
(see :5.1.1 Software Status)
A – 00 IDL ST ] [ ] [
*** *** *** ***
(GOBACK)
A – 00 IDL ST ] [ ] [
C – 07 IDL ST ] [ ] [
www.escalatorparts.cn
5.1.5 Group – Function M- 1 – 1 – 4
Key Sequence
Figure 5-7: Group – Function The second row displays the Software Status of one of
the other Controllers in the group.
(see: 5.1.1 Software Status)
A – 00 IDL ST ] [ ] [
*** *** *** ****
goon
- Key GOON / Shift Key GOBACK:
goon Skip to the next / previous Controller in the group.
(GOBACK)
A – 00 IDL ST ] [ ] [
C – 07 IDL ST ] [ ] [
www.escalatorparts.cn
5.1.6 ICSS - Function M– 1 – 1 - 5
Key Sequence
ICSS IS ONLINE The first row displays the status of first ICSS.
ICSS2 IS OFFLINE
The second row displays the status of the second ICSS.
www.escalatorparts.cn
5.1.7 Command – Function M–1–1-6
Key Sequence
goon
goon - Key GOON / Shift Key GOBACK:
Skip to the next / previous group of commands
(GOBACK)
A – 00 IDL ST ] [ ]
[ MC: GoTo To : 00
1)
2) 3)
1)
2) 3)
www.escalatorparts.cn
M–1–2
1 2 3 4 5
clear
www.escalatorparts.cn
5.2.1 Event – Function M–1–2–1
Key Sequence
1)
global information
2)
goon
- Key GOON / Shift Key GOBACK: Skip through the list of recorded
goon
event messages.
(GOBACK)
No more event
logged
www.escalatorparts.cn
Event logging
4) event logging
1 2) 3)
1) 1.row event text
Event reset
Erase Value ?
0400 RSL parity
(ON)
- Shift Key ENTER:
clear Termination of the reset
Function.
(ENTER)
Erase Value ?
done !
(UP)
clean
1 Erase Events ?
n=0 y=1 >
- Key CLEAR:
clear back to Test - Menu
www.escalatorparts.cn
5.2.2 Diagnosis - Function M–1–2-2
Key Sequence
The first row displays the name of the current diagnosis parameter.
01 DIAG ACT - T
000 : 00 : 00 : 34
1) 2)
Display Field Description
1) 02 Parameter no.
2) TOT-T Parameter name
3) 003 No. of months
02 DIAG TOT - T
4) 17 No. of days
003 : 17 : 22 : 57
5) 22 No. of hours
6) 37 No. of minutes
3) 4) 5) 6)
1) 2)
Display Field Description
1) 03 Parameter no.
03 DIAG UP - CNT 2) UP-CNT 3) Parameter name
000000079 000000079 No. of occurrences
3)
www.escalatorparts.cn
Diagnosis parameter reset
(ON)
2 - Shift Key UP
displays a short legend of
the time value – if a time – mon : d : h : min
(UP) value was displayed before. 003 : 17 : 22 : 57
clear
1 - Key and ENTER and
- Key and ENTER:
(ENTER) Termination of the reset Erase Events ?
Function. Please wait!
clear
2
(ENTER)
www.escalatorparts.cn
5.2.3 Part – No. - Function M–1–2–3
Key Sequence
No. GAA30082AAC
29 – Apr – 94 08:29 It also displays the date and the time of the LCB_II software
release.
clear
- Key CLEAR: back to Test - Menu
3)
1) 2)
4)
1) 1)E47NS9528 EEPROM version
E EE=E47NS9528
www.escalatorparts.cn
5.2.4 RSL – Test - Function M–1–2–4
Key Sequence
1
- Key 1,5: Input Keys of the
2 RSL - address
ADR=15
-
clear - Key CLEAR: deletes the last input if you want to correct
the number.
www.escalatorparts.cn
- Key GOON / Shift Key GOBACK:
goon
Skip to the next /
goon
Previous address.
ADR = 16 BIT = 1
IN : off OUT : off
ADR = 16 BIT = 2
IN : off OUT : off
ADR = 16 BIT = 2
IN : off OUT : on
clear - Key CLEAR:
back to Test - Menu
1) 2)
RSL: Status
www.escalatorparts.cn
Function Selftest can be used
- to test the memory of the LCB_II board and
PR ? EE ? RA ? - to check the Remote Serial Link.
RS ?_ _ _ _ _ _
The test will start as soon as the Selftest - Function
Is called.
www.escalatorparts.cn
RS - test
16 RSL - address
PR + EE + RA +
RS 16aR0000 A available (IO-No. is defined)
B not available
r not responding
goon - Key GOON / Shift Key GOBACK : Skip through the list of
Remote Station which signals
goon - not available or
- not responding or
- parity errors.
PR + EE + RA +
RS 48Ar000
www.escalatorparts.cn
5.3 SETUP - FUNCTION M–1–3
Key Sequence
1 6
Install – Menu >
01 System
000 System new 2 3 4 5 to Floor : Display
TOP =004> press ENTER
There are four different groups of Setup Parameters to define the elevator environ-
Ment:
- Installation Patameter
- RSL – IO Numbers
- Allowed Masks
- Position Indicator Parameter
- ELD - Display
The DCS – Function is used to test the well installed Door safety chain after startup
and setup phase.
www.escalatorparts.cn
5.3.1 Install - Function M–1-3
Key Sequence
3)
1)
goon
- Key GOON / Shift Key GOBACK :Skip through the assigned
goon Group of Installation
Parameter (System)
www.escalatorparts.cn
Enter a new parameter
1) 2)
clear - Key CLEAR : deletes the last input if you want to correct
the number.
(ENTER)
www.escalatorparts.cn
5.3.2 RSL – Function M–1–3–2
Key Sequence
IO I AD P AD P
> 0222_ _ _ _ _ _ _ _ _ _
www.escalatorparts.cn
Change the IO - Number
goon - Key GOON / Shift Key GOBACK: Skip to the next / previous
goon IO – Number.
(GOBACK)
1) 2)
clear - Key CLEAR : deletes the last input if you want to correct
the number.
clear
- Shift Key ENTER : Termination of the RSL – Parameter input
operation.
(ENTER)
www.escalatorparts.cn
5.3.3 Allowed – Function M–1–3-3
Key Sequence
Enable Display
Enable Display
1) 2) 3) 4) 5)
2) CUDE
at CUDE CUDE P R
front door Enable Mask
00 1100 0000 0 0
and 3) CUDE real door Enable Mask, with:
-C - Car Call
-U - Up Hall Call
-D - Down Hall Call
-E - Emergency Hospital Call
The Enable Masks (CUDE) allows the ( 1 = allowed / 0 = not allowed )
Elevator to run to a certain level depending
On the regarding call. 4) P Park Bit:
If the Parking Bit is set to 1, parking at a ( 1 = allowed / 0 = not allowed)
Certain level is not allowed (Group applic.)
The Reduced Landing No. indicates that 5) R Reduced landing No.:
The above floor is a Short – or Medium loading. - Short Run (1,2,3 = profile)
The velocity (profile) is a function of the number - Medium Run (4,5,6 = profile)
(1,2,3 or 4,5,6).
Cut_Call Display
www.escalatorparts.cn
Cut_Call Display
1) 2) 3) 4)
-U - Up Hall Call
Card_Rd ,display
1) 2) 3) 4) Card_Rd Display
-C - Car Call
-U - Up Hall Call
-D - Down Hall Call
-E - Emergency Hospital Call
The Card_Rd Masks (CUDE) are used to (1 = allowed / 0 = not allowed)
Reach certain floors with magnetic card
(Card Reader Operation).
The indication Special door open button
Defines the operation of the Special Door 4) Sb Special door open button
Open Button. 0 = both SDOB disabled
1 = only front SDOB enabled
2 = only rear SDOB enabled
3 = both SDOB enabled
www.escalatorparts.cn
Change the level
goon - Key GOON / Shift Key GOBACK: Skip to the next level number
goon
(GOBACK)
at CUDE CUDE P R
01 1110 0000 0 0
- Key CLEAR:
clear - Back to Allowed - Menu
(…)
(ENTER)
www.escalatorparts.cn
OTIS 2000 - Openings and Dummy Doors
www.escalatorparts.cn
5.3.4 POS - FUNCTION M–1–3-4
Key Sequence
R right digit
Pos . Ind new
At : L 00 = 10 > 2) 00 level number (00)
1) 2)
4) new input field for new value.
goon
- Key GOON /
goon Shift Key GOBACK :
Skip first to the next /
(GOBACK) previous digit and then to
the next / previous level. Pos . Ind . new
At : R 00 =00 >
- Key CLEAR:
clear back to Setup - Menu
www.escalatorparts.cn
ENTER a new digit
clear - Key CLEAR: deletes the last input if you want to correct
the number.
Reference List
0 0 10 (blank) 20 J* 30 T*
1 1 11 A 21 K* 31 U
2 2 12 B* 22 L 32 V*
3 3 13 C 23 M* 33 W*
4 4 14 D* 24 N* 34 X*
5 5 15 E 25 O 35 Y*
6 6 16 F 26 P 36 Z*
7 7 17 G* 27 Q* 37
8 8 18 H 28 R* 38
9 9 19 I* 29 S 39
www.escalatorparts.cn
5.3.5 Door Check Sequence M–1–3-5
Key Sequence
The Door Check Sequence (DCS) – Function is a safety feature for OTIS 2000 Controllers
MCS120 and MCS220 (M), It insures that all hoist way door contacts are installed correctly and will
Open the safety chain.
Until the Door Check Sequence is finished successfully it is only possible to move the car in inspection
mode. Normal runs are disabled.
For LSVF (-W) without speed encoder it is necessary to calibrate the drive package in Inspection an
Normal mode before the DCS can be done.
In an Installation with LSVF or LSVF – W without Advanced Door Opening and without Relieving
the following display appears:
Allow Normal = 0
Start DCS = 1
1
- Key 1: Start the DCS immediately.
www.escalatorparts.cn
Direction Description
Position Description
- 00 DW :clsd ] [ ]
00 actual level (level 0)
[ open front door ** level position not defined
DW status Description
www.escalatorparts.cn
If a failure occurred the error is displayed in the 2nd row. The 1st row shows the status including
The level number where the error was detected:
DCS successful
Press GOON >
(GOBACK)
LCB_II - Menu
System = 1 Tools = 2
www.escalatorparts.cn
5.3.6 ELD - Function M–1–3-6
Key Sequence
The ELD – Function is used to define the “Customer Message” of the OTIS 2000 - ELD
For each floor the Customer Message can be displayed (Floor Display)
modified (Edit Display and Default Display)
or store into EEPROM (Store Display).
Block diagram
1) 2) Floor Display
3)
1) 00 level number <GOON,GOBACK>
2) ALL Edit – Mode: <UP, DOWN>
00 < FLOOR ALL < ELD ALL:all characters available
BASEMENT A-Z: only A-Z
0-9: only 0-9
&/): only&(),- / : <>
clear
< SPE:only A A A C /E HEX:
> all characters available
Using hex input
Send to ELD enter clear mov: move the string to the left
of the right
current: Customer Message:
BASEMENT
4) 5)
Edit Display
00 T< ALL ELD 4) T selected character <GOOM,GOBACK>
BASEMENT ? 5) T selected string position<UP,DOWN>
enter
enter clear
enter
Store Display
on
confirm the storage operation with
00 write E2 P? Key <ENTER>
BASEMENT
6) 7)
Defaut Display
6)00 No. of Default Message
8) <GOON,GOBACK>
7)ENG Select Language
00 00 < ELDdef > ENG
LOBBY
ENG english
GER german
ITA italian
8) selected Default Message
(see Reference Table below)
www.escalatorparts.cn
Floor Display: Select Floor and Edit Mode
goon
goon 9 01 < Floor All < ELD
_ _ _ _ FLOOR 1_ _ _
(GOBACK)
2 3 - Key UP/DOWN:
Selects the Edit-Mode ,which will be used in Edit – Display.
(UP) (DOWN)
(ENTER)
- Key Clear:
clear
Back to Setup – Menu.
Modified Message will be sent to the ELD – Module.
www.escalatorparts.cn
Edit Display : Modify Customer Message
- Key UP / DOWN:
2 3 The second row display the current Customer Message.
Use Key UP / Down to select the position of current string
you want to modify. The position is marked with a bliking “?”
The selected Character is displayed in the Edit – Field of row one.
(UP) (DOWN)
(GOBACK)
1 - Key 1 – 9:
Skips through the character set using the selected step width.
9
(Key-No.)
(ENTER)
-Key ON:
1
Transition to Default Display
(ON) To use predefined Customer
Messages.
(see Reference Table below) 00 00 < ELDdef > ENG
LOBBY
-Key CLEAR:
clear
Back to Floor Display e,g. to change the Edit – Mode. The current
Message will be buffered.
www.escalatorparts.cn
Edit Modes HEX and mov
HEX Display
1) 2) HEX Display
1) Y Edit - Field
2) 59 HEX - Field
0 0 Y < 59 HEX ELD Display the HEX - Value of the selected character
LOBB? 3) selected Character (Y < - > ?)
3)
(UP) (DOWN)
(GOBACK)
- Key 0…F:
0 F Input of 2 digits Hex – Code in HEX – Field to define the new character
(see Reference Table below).
…
Mov Display
(GOBACK)
www.escalatorparts.cn
Default Display: Use of predefined messages
2 3 - Key UP / DOWN:
Selects the language of the Default Message (ENG,GER,ITA)
F F
(UP) (DOWN)
goon
- Key GOON / GOBACK:
goon 2 Skips through the Default Message List.
(see Reference Table below)
(GOBACK)
- Key 0 – 9
0 9 Two digits input to select the Default Message by entering
the List – No.
(see Reference Table below)
on
- Key CLEAR, OFF:
clear Back to Edit Display without buffering the changes.
(OFF)
www.escalatorparts.cn
Reference Tables for ELD - Function
DEFAULT MASSAGES
NO. ENG GER ITA
0 LOBBY ERDGESCHOSS TERRANO
1 BASEMENT KELLER SOTTERRANEO
2 PENTHOUSE DACHTERRASSE ATTICO
3 FLOOR ETAGE PLANO
4 RECEPTION EMPFANG RICEZIONE
5 EXIT AUSGANG USCITA
6 GARAGE TIEFGARAGE POSTEGGIO
7 SECRETARY SEKRETARANT SEGRETERIA
8 RESTAURANT RESTAURANT RISTORANTE
9 CAFETERIA KAFFESTUBE CAFFETERIA
10 GARAGE PARKHAUS POSTEGGIO
11 POOL SCHWIMMHALLE PISCINA
12 SAUNA SAUNA SAUNA
13 DOCTOR ARZT DOTTORE
14 0 123 456 789 0 123 456 789 0 123 456 789
15 : . () <> / - , & ‟ : . () <> / - , & ‟ : . () <> / - , & ‟
16 ABCD EFGH IJKL ABCD EFGH IJKL ABCD EFGH IJKL
17 MNOP QRST UVWXYZ MNOP QRST UVWXYZ MNOP QRST UVWXYZ
18 Ä Á Å Ç Ø ö /E Ä Á Å Ç Ø ö /E Ä Á Å Ç Ø ö /E
19 empty string
ASCII HEX ASCII HEX ASCII HEX ASCII HEX ASCII HEX
Blank 20 0 30 A 41 N 4E Ä 80
& 26 1 31 B 42 O 4F Á 81
( 28 2 32 C 43 P 50 Å 82
) 29 3 33 D 44 Q 51 Ç 83
, 2C 4 34 E 45 R 52 A- 84
- 2D 5 35 F 46 S 53 -E 85
. 2E 6 36 G 47 T 54 Ø 86
/ 2F 7 37 H 48 U 55 ö 87
: 2A 8 38 I 49 V 56
< 3C 9 39 J 4A W 57
> 3E K 4B X 58
L 4C Y 59
M 4D Z 5A
www.escalatorparts.cn
M-2
5.4 TOOLS – Function
Key Sequence
1…9 clear
www.escalatorparts.cn
M–2–1
5.4.1 Search – IO - Function
Key Sequence
Possible Results:
(a) no IO – number found (b) first IO – number found
Search – IO Search – IO ?
no match ! >15 3 < ro: 0676_
www.escalatorparts.cn
The first IO – number is found : IO :0676
clear Search – IO !
- Shift Key ENTER: > 15 3 < IO: 0676
Continue the Search Run.
(ENTER)
(ENTER)
Search – IO !
> 15 4 < IO: 0676
www.escalatorparts.cn
5.4.2 Erase – IO - Function M–2–2
Key Sequence
Figure 5 – 23: Erase IO_Part (see document: List of inputs and Outputs)
(ENTER)
(ENTER)
(ENTER)
clear
2 - Key 2 and Shift Key ENTER
Second Confirmation to
start the function.
(ENTER) Erase IO Part !
Please Wait : 107
During the run the displayed
counter is counting down to zero.
www.escalatorparts.cn
5.4.3 Setup install - Function M–2–3
Key Sequence
clear
- Key 0 and Shift Key ENTER
0
First Confirmation
(ENTER)
clear
- Key 1 and Shift Key ENTER
1
First Confirmation
Setup Install ?
N=0 y=2 / Enter
(ENTER)
clear
- Key 0 and Shift Key ENTER : back to TOOLS – Menu
0
(ENTER)
www.escalatorparts.cn
5.4.4 Operate Memory M–2-9
Key Sequence
7 8 9
LCB_II - Menu 4 5 6
System = 1 Tools = 2
0 - OFF
M 7 8 9 1 - ON
2 - UP
3 - DOWN
F 4 5 6
4 - DISP IN - A
5 - SEL OUT - B
6- - C
S 3 2 1 7 - DISP STATE - D
8 - ENT CALL - E
9 - TEST - F
0 goon clear
ENTER
GOBACK
Shift Key
www.escalatorparts.cn
The first row of Figure 5 – 26 display the Software
Status (see:5.1.1)
The second row displays the input field for the de-
sired Memory Address.
After the address is entered is entered. the next two bytes of
memory are displayed.
A – 00 IDL ST ] [ ]
[00000
Please notice that PLM – words are stored in the order:
LOW – byte / HIGH - byte
(ENTER)
1) 2)
www.escalatorparts.cn
Change the memory address
www.escalatorparts.cn
Change the memory contents
Depending on how many digits are entered the first byte or both or both bytes
are stored. The first up to two digits form the first byte and the next up to row
digits the second byte.
(GOBACK) A – 00 IDL ST ] [ ]
[ 0 0 0 2 D : ABCD
A – 00 IDL ST ] [ ] [
clear - Key ENTER: 0 0 0 2 D : ABCD>12 – 3+
Storing the new byte
resp.two bytes.
A short appearing “+” behind
(ENTER) the entered byte resp. two
bytes acknowledges the
successful storing A – 00 IDL ST ] [ ] [
failure (e.g.memory address 0 0 0 2 D : 1203
is out of RAM area).