Professional Documents
Culture Documents
Beams in general
Nails, bolts:
Foreign parts not allowed.
Nailholes allowed.
Transverse cracks:
Cracks across the grain not allowed.
Straight cracks:
Cracks up to a width of 2mm allowed.
At a glance I 27
1.3 Technical Condition Timber Formwork Beam
Drying and shrinkage cracks:
Allowed if it is not possible to pull the strap
apart.
Saw cuts:
Superficial cuts up to 2mm depth are allowed.
At a glance I 28
1.3 Technical Condition Timber Formwork Beam
Lateral breakaways:
Up to a depth of 10mm and a length of
500mm one-sided allowed.
At a glance I 29
1.3 Technical Condition Timber Formwork Beam
Base inside:
Heavily damaged areas not allowed.
At a glance I 30
1.3 Technical Condition Timber Formwork Beam
Beam end
N and P-beams:
End reinforcement must have tight seat.
Top beam:
Sufficient protection is given as long as the
plastic caps on strap and base still have a tight
seat i.e. they can not be moved by hand.
Bulges larger than 1mm are not allowed.
At a glance I 31
1.3 Technical Condition Timber Formwork Beam
e.g. Plastic cap has tight seat.
At a glance I 32
1.3 Technical Condition Timber Formwork Beam
Drillings
System drillings:
e.g. System drilling in the plastic cap at the
strap.
Other drillings:
No additional drillings, except the system
drillings, are allowed in the strap.
In the base two additional drillings per running
meter with a maximum diameter of 30mm are
allowed.
At a glance I 33
Notes
At a glance I 34