You are on page 1of 9

JOB CARD PACKAGE TITLE: MLT -

TASK 73-21-00-710-805-A Tail Number - MSN -


FSN
9H-JFS - 00466 - 054

MPD Reference Title DocType

Operational test of the FADEC on the Ground


NONE 73-21-00-710-805-A AMM
with Engine non Motoring

Job Cards Package is made of: 1 job cards.

JCP Title: TASK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 1 of 2


73-21-00-710-805-A PRINT DATE: Jun 14/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD PACKAGE TITLE: MLT -
TASK 73-21-00-710-805-A Tail Number - MSN -
FSN
9H-JFS - 00466 - 054

INTENTIONALLY LEFT BLANK

JCP Title: TASK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 2 of 2


73-21-00-710-805-A PRINT DATE: Jun 14/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Apr 01/2023
AMM - MLT - A330 TASK:
73-21-00-710-805-A
73-21-00-05 CONF 11
Tail Number - MSN - TITLE:
MPD TASK:
FSN: 73-21-00-710-805-A - Operational test of the FADEC on the NONE
9H-JFS - 00466 - 054 Ground with Engine non Motoring

MECH. INSP.

** ON A/C FSN 002-100


TASK 73-21-00-710-805-A
Operational test of the FADEC on the Ground with Engine non Motoring
1. Reason for the Job
Self Explanatory.
This is a static (power on/engine off) test. There will be no actuation of
controls. During the system test, all of the ECU electrical interfaces to the Fuel
Metering Valve (FMV), Variable Stator Vane (VSV) actuators, Variable Bleed
Valve (VBV) actuators, High Pressure Turbine Active Clearance Control
(HPTACC) valve, and Low Pressure Turbine Active Clearance Control
(LPTACC) valve will be tested for current wrap faults.

2. Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

REFERENCE QTY DESIGNATION


No specific AR ACCESS PLATFORM 3M (10 FT)-
ADJUSTABLE

B. Work Zones and Access Panels

ZONE/ACCESS ZONE DESCRIPTION


811

C. Referenced Information

REFERENCE DESIGNATION
Ref. Energize the Ground Service Network
24-42-00-861-801-A
Ref. De-energize the Ground Service Network
24-42-00-862-801-A
Ref. Air Data/Inertial Reference System (ADIRS)
34-10-00-860-801-A Start Procedure

JCP Title: TASK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 1 of 7


73-21-00-710-805-A PRINT DATE: Jun 14/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Apr 01/2023
AMM - MLT - A330 TASK:
73-21-00-710-805-A
73-21-00-05 CONF 11
Tail Number - MSN - TITLE:
MPD TASK:
FSN: 73-21-00-710-805-A - Operational test of the FADEC on the NONE
9H-JFS - 00466 - 054 Ground with Engine non Motoring

MECH. INSP.

REFERENCE DESIGNATION
Ref. Procedure to Get Access to the SYSTEM
45-10-00-860-826-A REPORT/TEST ENG Page
Ref. Fig. FADEC Non Motoring Test Menus

3. Job Set-up

SUBTASK 73-21-00-861-053-A
A. Energize the ground service network
Ref. AMM TASK 24-42-00-861-801.

SUBTASK 73-21-00-010-053-A
B. Get access to the avionics compartment.
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in
position at the access door 811.
(2) Open the access door 811.
(3) Open the protective door of the AC/DC emergency power-
center 740VU.

SUBTASK 73-21-00-865-053-A
C. Make sure that this (these) circuit breaker(s) is (are) closed:

PANEL DESIGNATION FIN LOCATION


FOR FIN 4030EM1(DEMOUNTABLE POWER PLANT, ENG1)

** ON A/C FSN 002-100


721VU IGN SYS B ENG 1 2EH1 G03

** ON A/C FSN 051-100


721VU EIVMU 1 14KS1 P05

JCP Title: TASK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 2 of 7


73-21-00-710-805-A PRINT DATE: Jun 14/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Apr 01/2023
AMM - MLT - A330 TASK:
73-21-00-710-805-A
73-21-00-05 CONF 11
Tail Number - MSN - TITLE:
MPD TASK:
FSN: 73-21-00-710-805-A - Operational test of the FADEC on the NONE
9H-JFS - 00466 - 054 Ground with Engine non Motoring

MECH. INSP.

PANEL DESIGNATION FIN LOCATION

** ON A/C FSN 002-100


722VU FADEC B ENG 1 13KS1 D44
742VU FADEC A ENG 1 12KS1 Q73
742VU IGN SYS A ENG 1 1EH1 Q70
FOR FIN 4030EM2(DEMOUNTABLE POWER PLANT, ENG2)
721VU EIVMU 2 14KS2 P06
722VU IGN SYS B ENG 2 2EH2 F50
722VU FADEC B ENG 2 13KS2 K49
742VU FADEC A ENG 2 12KS2 Q74
742VU IGN SYS A ENG 2 1EH2 Q71

SUBTASK 73-21-00-869-058-A
D. Prepare for Test
(1) Do the ADIRS 1 and 2 start procedure Ref. AMM TASK
34-10-00-860-801.
(2) On the panel 285VU:
- Push the ENG FADEC GND PWR/1(2) pushbutton
switch. The ON legend of this pushbutton switch
comes on.

NOTE: 2 seconds can be necessary before the ENG


FADEC GND PWR pushbutton switch comes on.

(3) Do the procedure to get the SYSTEM REPORT/TEST ATA:


70-90 ENGINES Ref. AMM TASK 45-10-00-860-826.

4. Procedure
Ref. Fig. FADEC Non Motoring Test Menus

JCP Title: TASK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 3 of 7


73-21-00-710-805-A PRINT DATE: Jun 14/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Apr 01/2023
AMM - MLT - A330 TASK:
73-21-00-710-805-A
73-21-00-05 CONF 11
Tail Number - MSN - TITLE:
MPD TASK:
FSN: 73-21-00-710-805-A - Operational test of the FADEC on the NONE
9H-JFS - 00466 - 054 Ground with Engine non Motoring

MECH. INSP.

SUBTASK 73-21-00-710-053-A
A. Do the test.

NOTE: This test is for the system 1. For the other system(s), use
the indications between parentheses.

ACTION RESULT
1.On the MCDU:
A.Push the line key adjacent to The SYSTEM REPORT/TEST
FADEC STATUS indication. ENG menu comes in view.
B.Push the line key adjacent to The ECU1(2) CHAN A page
the ECU1(2) CHAN A indication. comes in view.
C.Push the line key adjacent to The SYSTEM TEST menu comes
the SYSTEM TEST indication. in view.
2.Push the line key adjacent to The TEST IN PROGRESS
the START TEST indication. indication comes in view. When
the test is finished the FADEC
TEST REPORT comes in view
with the TEST OK indication.

NOTE: If you push the return key the test will abort.
3.Push the line key adjacent to The ECU1(2) CHAN A screen
the RETURN indication. comes in view.
4.Do this procedure again for channel B of the FADEC 1(2), steps
2-5.
5.Continue to press the return indicator to return back to the
SYSTEM REPORT/TEST ENG menu after completion of the FADEC
system test.

5. Close-up

SUBTASK 73-21-00-869-059-A

JCP Title: TASK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 4 of 7


73-21-00-710-805-A PRINT DATE: Jun 14/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Apr 01/2023
AMM - MLT - A330 TASK:
73-21-00-710-805-A
73-21-00-05 CONF 11
Tail Number - MSN - TITLE:
MPD TASK:
FSN: 73-21-00-710-805-A - Operational test of the FADEC on the NONE
9H-JFS - 00466 - 054 Ground with Engine non Motoring

MECH. INSP.

A. Close-up the panels


(1) Push the ENG 1(2) FADEC GND PWR pushbutton switch on
panel 285VU. The ON legend must go OFF.

SUBTASK 73-21-00-410-053-A
B. Close Access
(1) Make sure that the work area is clean and clear of tools and
other items.
(2) Close the protective door of the AC/DC emergency power
center 740VU.
(3) Close the access door 811.
(4) Remove the access platform(s).

SUBTASK 73-21-00-862-051-A
C. De-energize the ground service network
Ref. AMM TASK 24-42-00-862-801.

JCP Title: TASK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 5 of 7


73-21-00-710-805-A PRINT DATE: Jun 14/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Apr 01/2023
AMM - MLT - A330 TASK:
73-21-00-710-805-A
73-21-00-05 CONF 11
Tail Number - MSN - TITLE:
MPD TASK:
FSN: 73-21-00-710-805-A - Operational test of the FADEC on the NONE
9H-JFS - 00466 - 054 Ground with Engine non Motoring

MECH. INSP.

Figure 73-21-00-991-00900-11-A (SHEET 1/2) - FADEC Non Motoring Test Menus

** ON A/C FSN 002-100

JCP Title: TASK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 6 of 7


73-21-00-710-805-A PRINT DATE: Jun 14/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE
JOB CARD REV DATE: Apr 01/2023
AMM - MLT - A330 TASK:
73-21-00-710-805-A
73-21-00-05 CONF 11
Tail Number - MSN - TITLE:
MPD TASK:
FSN: 73-21-00-710-805-A - Operational test of the FADEC on the NONE
9H-JFS - 00466 - 054 Ground with Engine non Motoring

MECH. INSP.

Figure 73-21-00-991-00900-11-A (SHEET 2/2) - FADEC Non Motoring Test Menus

** ON A/C FSN 002-100


© *** END OF CARD ***

JCP Title: TASK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 7 of 7


73-21-00-710-805-A PRINT DATE: Jun 14/2023
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN
COMPLETED TO THE REQUIRED STANDARD AND SUPPORTS
THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF
RELEASE TO SERVICE

You might also like