Professional Documents
Culture Documents
To improve the effectiveness of the water content of a The optimum dosage of Conplast P509 to meet specific
concrete mix. requirement should always be determined by trials using
the materials and conditions that will be experienced in
At higher dosages to provide a cost effective means
use. The normal dosage range is 0.2 to 0.6 litres / 100 kg
of reducing concrete permeability and thereby
of cementitous material, including PFA, GGBFS and
reducing water penetration.
microsolica.
Advantages
Use at Other Dosage
Particularly effective in improving compressive
Dosages outside the normal range quoted above can be
strength of mixes containing PFA and GGBFS.
used to meet particular mix requirements.
Water reduction significantly improves compressive
Properties
strengths at all ages and increased without adding
extra water. Appearance Brown liquid
Conplast P509 complies with BS 5075 Part 1 and with Alkali content Typically less than 4.0 grams Na20
ASTM C494 as Type A and Type D, depending on dosage equivalent/litre admixture
used. Instructions for Use
Page 1
Conplast P509
Increased cement contents, which lead to higher total Conplast P509 does not fall into the hazard classifications of
levels of admixture in a cubic meter of concrete, may current regulations. However, it should not be swallowed or
lead to increased retardation being obtained. allowed to come into contact with skin and eyes. Suitable
protective gloves and goggles should be worn.
Changes in cement source of chemistry may lead to
variations in the retardation obtained. The amount of Splashes on the skin should be removed with water. In
tri-calcium aluminates in the cement has been identified case of contact with eyes rinse immediately with plenty of
as being one of the main contributory factors in this water and seek medical advice. If swallowed seek medical
respect, with a lower level leading to greater attention immediately – do not induce vomiting.
retardation. Fire
Increased retardation will be obtained at higher dosage. As Conplast P509 is water based and non flammable.
a guideline, dosages of 0.31 litres / 100 kg and above are
Cleaning and Disposal
likely to be in the retarding category.
regarding suitable equipment and its installation. be carried out in accordance with local legislation under the
guidance of the local waste regulatory authority.
Effects of overdosing
Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for the
Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that any advice,
recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct or continuous control
over where or how its products are applied, accept any liability either directly or indirectly arising from the use of its products, whether or
Fosroc Sdn. Bhd. not in accordance with any advice, specification, recommendation of information given by it.
Branch Office:
+60 4 2287 464 +60 4 2292 661
29, Jalan Zainal Abidin,
10400 Penang, Malaysia.