You are on page 1of 2

Conplast P509 constructive solutions

Water Reducing Admixture

Uses Typical Dosage

 To improve the effectiveness of the water content of a The optimum dosage of Conplast P509 to meet specific
concrete mix. requirement should always be determined by trials using
the materials and conditions that will be experienced in
 At higher dosages to provide a cost effective means
use. The normal dosage range is 0.2 to 0.6 litres / 100 kg
of reducing concrete permeability and thereby
of cementitous material, including PFA, GGBFS and
reducing water penetration.
microsolica.
Advantages
Use at Other Dosage
 Particularly effective in improving compressive
Dosages outside the normal range quoted above can be
strength of mixes containing PFA and GGBFS.
used to meet particular mix requirements.
 Water reduction significantly improves compressive
Properties
strengths at all ages and increased without adding
extra water. Appearance Brown liquid

 Allows specified strength grades to be met at reduced Specific Gravity


0
Typically 1.23 at 25 C
cement content or increased workability.
Chloride content Nil to BS5075
 Chloride free, safe for use in prestressed and
reinforced concrete. Air entrainment Typically <2% additional air is entrained
Standards Compliance at normal dosages

Conplast P509 complies with BS 5075 Part 1 and with Alkali content Typically less than 4.0 grams Na20
ASTM C494 as Type A and Type D, depending on dosage equivalent/litre admixture
used. Instructions for Use

Conplast P509 complies with the requirements of the Compatibility


United Kingdom Water Fittings Byelaws Scheme and is
Conplast P509 is compatible with other Fosroc admixtures
listed in the Directory of Materials
in the same concrete mix. All admixtures should be added
Description to the concrete separately and must not be mixed together
Conplast P509 is supplied as a brown solution, which prior to addition. The performance of concrete containing
instantly disperses in water. more than one admixture should be assessed by trial
mixes.
Conplast P509 disperses the fine particles in the concrete
mix, enabling the water content of the concrete to perform Conplast P509 is suitable for use with all types of ordinary
more effectively and improving the consistency of the Portland Cement and cement replacement materials such
concrete. This produces higher levels of workability for as PFA, GGBFS and microsilica.
the same water content, allowing benefits such as water Effects on stiffening and set
reduction and increased strengths to be taken.
Most water reducing admixtures produce some delay in
Technical Support the stiffening of concrete, although the degree may vary.
Fosroc provides a technical advisory service for on-site Retardation is affected by factors other than the
assistance and advice on admixture selection, evaluation admixture, depending on the mix details and conditions
trials and dispensing equipment. involved. Trials to assess the effects in a particular mix

Page 1
Conplast P509

are strongly recommended if this aspect is of particular Estimating - Packaging


importance.
Conplast P509 is available in 210 litre drums, 1000 litre tote
Major factors which may lead to an increase in retardation tanks or bulk (tanker) supply for large orders.
include the following:
Shelf Life
 Cement replacement materials will usually give greater
Conplast P509 has a minimum shelf life of 12 months
levels of retardation than concrete mixes made with o
provided the temperature is kept within the range of 2 C to
OPC at the same admixture dosage. o
50 C.
 Low temperature will give higher levels of retardation for
Precautions
the same admixture dosage. This is particularly
noticeable if cement replacement materials are used. Health and Safety

 Increased cement contents, which lead to higher total Conplast P509 does not fall into the hazard classifications of
levels of admixture in a cubic meter of concrete, may current regulations. However, it should not be swallowed or
lead to increased retardation being obtained. allowed to come into contact with skin and eyes. Suitable
protective gloves and goggles should be worn.
 Changes in cement source of chemistry may lead to
variations in the retardation obtained. The amount of Splashes on the skin should be removed with water. In
tri-calcium aluminates in the cement has been identified case of contact with eyes rinse immediately with plenty of
as being one of the main contributory factors in this water and seek medical advice. If swallowed seek medical
respect, with a lower level leading to greater attention immediately – do not induce vomiting.
retardation. Fire
Increased retardation will be obtained at higher dosage. As Conplast P509 is water based and non flammable.
a guideline, dosages of 0.31 litres / 100 kg and above are
Cleaning and Disposal
likely to be in the retarding category.

Dispensing Spillages of Conplast P509should be absorbed onto sand,


earth or vermiculite and transferred to suitable containers.
The correct quantity of Conplast P509 should be measured Remnants should be hosed down with large quantities of
by means of a recommended dispenser. The admixture water.
should then be added to the concrete with the mixing water
to obtain the best result. Contact Fosroc for advice The disposal of excess or excess or waste material should

regarding suitable equipment and its installation. be carried out in accordance with local legislation under the
guidance of the local waste regulatory authority.
Effects of overdosing

Overdosing may cause increased air entrainment, which will


tend to reduce strength. The degree of this effect will
depend on the particular mix design and overdose level.

Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for the
Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that any advice,
recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct or continuous control
over where or how its products are applied, accept any liability either directly or indirectly arising from the use of its products, whether or
Fosroc Sdn. Bhd. not in accordance with any advice, specification, recommendation of information given by it.

No 8 Jalan Trompet, 33/8


Seksyen 33, 40400 Shah Alam telephone: fax: email:
Selangor, Malaysia +60 3 5191 5660 +60 3 5191 6960 malaysia@fosroc.com

Branch Office:
+60 4 2287 464 +60 4 2292 661
29, Jalan Zainal Abidin,
10400 Penang, Malaysia.

www.fosroc.com Page 2 MAL/0102/10A