ft closure of Letter No. fb3 /Purchase/General/(2121-0052)2022/ 2- S dated 1/ /05/2022
ANNEXURE-A
Rates for LS.I Marked Ductile Iron Pressure Pipes conforming to l.S -8329/2000 or its latest
amendment(s).
s. Nominal Dia. & F.O.R. Destination Rates per meter (exclusive of G.S.T.) in Rs.,
No. Class of Pipe
anywhere in U.P. up to stores of consignees, inclusive of third party
inspection charges, packing and forwarding charges, transit
insurance charges, road transportation charges etc.
I. 2. 3.
1. 80/cfi-7 953.00
2. 100/cfi-7 1158.00
3. 125/cfi-7 1435.00
4. 150/cfi-7 1639.00
5. 200/cfi-7 2127.00
6. 250/cfi- 7 2795.00
7. 300/cfi-7 3589.00
8. 350/cfi 7 4417.00
9. 400/cfi 7 5372.00
11 . 500/cfi 7 7557.00
1. 80/cfi 9 1092.00
2. 100/cfi 9 1332.00
3. 125/cfi 9 1648.00
4. 150/cfi 9 J892.00
5. 200/cfi 9 2547.00
6. 250/cfi 9 3419.00
7. 300/cfi 9 4341.00
8. 350/cfi 9 5333.00
9. 400/cfi 9 6469.00
NOTE: - Goods and Services Tax (G .S.T.) is to be paid extra on F.O.R. destination rates .
[ . of Letter No.
I e,3 /Purchase/General/(2121-0052)2022/ ' s- dated I I/05/2022
ANNEXURE-B
Rates for LS.I Marked H.D.P.E Pipes conforming to I.S. 4984:2016 or its latest
amendment(s}
s. Dia. in mm, Pressure Rating F.O.R. Destination Rates per meter (exclusive of G.S.T.) in Rs.,
No. of H.D.P.E Pipes anywhere in U.P. up to stores of consignees, inclusive of third
party inspection charges, packing and forwarding charges,
transit insurance charges, road transportation charges etc.
GRADE-PE-100
1. 2. 3.
90/cft.1:1:,. -6 195.00
1.
110/cft.1:!:,.-6 282.00
2.
12 s/cft. 1:1:,. -6 358.00
3.
140/cft.1:1:,. -6 451.00 .
4.
160/cft."Q:,. -6 587.00
5.
180/cft.1:1:,. -6 742.00
6.
200/cft.1:1:,. -6 916.00
7.
90/cft."Q:,.-8 234.00
8.
110/cft.1:!:,.-8 338.00
9.
12s/cft.1:1:,. -8 431.00
IO.
140/cft.1:1:,. -8 544.00
11.
710.00
160/cft.1:!:,. 8
12.
,so/cft.1:1:,.-8 895.00
13.
1102.00
200/cft.1:1:,. 8
14.
287.00
90/cft.1:1:,. 10
15.
409.00
110/cft.1:1:,. 10
16.
524.00
12s/cft.1:1:,. -1 o
17.
660.00
140/cft.1:1:,. 10
18.
860.00
160/cft."Q:,. 10
19.
1093.00
180/cft .1:1:,. 1o
20.
1342.00
200/cft.1:1:,. -10
21.
· Tax (G .s.T). is to be paid extra on F.O.R. destination rates .
.!:iQI!: - Goods an d Serv1ces
{i ,ure of Letter No.
0 1,(,
3 /Purchase/General/(2121-0052)2022/ :z ? dated r1 /05/2022
ANNEXURE-C
Rates for LS.I Marked H.D.P.E Pipes conforming to I.S. 14333/1996 or its latest
amendment(s)
s. Dia. in mm, Pressure Rating F.O.R. Destination Rates per meter (exclusive of G.S.T.) in Rs.,
No, of H.D.P.E Pipes anywhere in U.P. up to stores of consignees, inclusive of third
party inspection charges, packing and forwarding charges,
transit insurance char2es, road transportation chari?:es etc.
GRADE-PE-100
1. 2. 3.
1. 110/ITT.1!:[.-6 332.00
2. 140/ITT.1!:[.-6 532.00
3. 160/ITT.1!:[. -6 690.00
4. 200/ITT.1!:[. -6 1078.00
5. 11 o/lTT.1!:f. -s 419.00
6. 140/ITT.1!:[. 8 673.00
7. 160/ITT.1!:[. 8 873.00
200/ITT.1!:f. 8 1366.00
8.
11 o/lTT .1!:f. 10 496.00
9.
140/ITT.1!:[. 10 805.00
10.
160/ITT. 'Q:f. 10 1045.00
11.
12. 2oo/lTT. 'Q:f. 10 1631.00
NOTE,. Goods '"d Se<,ioes Ta, (G.S.T.) is to bo paid «tra oo F.O.R. destioatioo rates. t-~~y/
nd
To, Date: 22 April 2022
UP JAL NIGAM
LUCKNOW
Sir,
With reference to the above,we are herebysending thecomplete techno-commercialofferfor DI Valves different size
of VAG make as Follows:-
1.
1002 SAME AS ITEM NO. 1001, BUT EXCAVATION IN SOIL MIXED WITH MOORUM,
SHINGLE, KANKAR REQUIRING THE USE OF SPECIAL T & P SUCH AS Cum. 203.97
PICKAXES, SABBALS ETC..
1003 BANKING WITH EXCAVATED EARTH IN LAYERS NOT EXCEEDING 15 CM IN
DEPTH BREAKING CLODS, WATERING, RAMMING EACH LAYER WITH
WOODEN OR IRON HAMMERS AND THAPIES AND DRESSING UP IN
EMBANKMENTS SUCH AS FOR ROAD, FLOOD BANKS, MARGINAL BUNDS, Cum. 64.45
GUIDE BANK AND SEWAGE FARM CHANNEL ETC. INCLUDING 1.5 M LIFT
AND 50 M LEAD EXCLUDING EXCAVATION.
1006 EXTRA OVER ITEMS 1001 TO 1005 ABOVE FOR EVERY ADDITIONAL 50 M
LEAD OR PART OF IT OR FOR EVERY ADDITIONAL 1.5 M LIFT OR PART OF IT. Cum. 29.70
2. CONCRETE
1007 CONCRETE WITH 40 MM GAUGE BRICK BALLAST, WHITE LIME & SAND
MORTAR (1:2) IN FOUNDATIONS AND FLOORS INCLUDING SUPPLY OF ALL
Cum. 4346.65
MATERIALS, LABOUR, T&P ETC. REQUIRED FOR PROPER COMPLETION OF
THE WORK.
1008 CONCRETE WITH 40 MM GAUGE BRICK BALLAST, WHITE LIME & SURKHI IN
FOUNDATIONS AND FLOORS IN PROPORTION OF 100:16:32 INCLUDING
Cum. 4462.00
SUPPLY OF ALL MATERIALS, LABOUR, T&P ETC. REQUIRED FOR PROPER
COMPLETION OF THE WORK.
1009 CONCRETE WITH 40 MM GAUGE BRICK BALLAST, LOCAL SAND AND
CEMENT IN PROPORTION OF (12:6:1) IN FOUNDATIONS AND FLOORS
Cum. 3811.09
INCLUDING SUPPLY OF ALL MATERIALS, LABOUR, T&P ETC. REQUIRED FOR
PROPER COMPLETION OF THE WORK.
1010 SAME AS ITEM 1009 BUT IN PROPORTION OF 10:5:1. Cum. 3998.70
1011 SAME AS ITEM 1009 BUT COURSE SAND IN PROPORTION OF 8:4:1. Cum. 5221.10
1012 CONCRETE WITH 40 MM GAUGE BRICK BALLAST, WHITE LIME AND SAND
MORTAR IN PROPORTION OF 1:2 IN HAUNCH FILLING INCLUDING SUPPLY
Cum. 5068.05
OF ALL MATERIALS, LABOUR, T&P ETC. REQUIRED FOR PROPER
COMPLETION OF THE WORK.
1013 CONCRETE WITH 40 MM GAUGE BRICK BALLAST & KANKAR LIME IN ROOF
TERRACING INCLUDING SUPPLY OF ALL MATERIALS, LABOUR, T&P ETC.
Cum. 5842.99
REQUIRED FOR PROPER COMPLETION OF THE WORK INCLUDING MAKING
SHALLOW DRAIN IF REQUIRED.
1014 CONCRETE WITH 25 MM GAUGE BRICK BALLAST, WHITE LIME AND SURKHI
IN PROPORTION OF 100:18:36 IN ROOF TERRACING INCLUDING SUPPLY OF
Cum. 5978.00
ALL MATERIALS, LABOUR, T&P ETC. REQUIRED FOR PROPER COMPLETION
OF THE WORK.
1015 CEMENT CONCRETE WITH 20 MM GAUGE APPROVED STONE BALLAST,
COARSE SAND AND CEMENT IN THE PROPORTION OF 4:2:1 INCLUDING
Cum. 8445.73
SUPPLY OF ALL MATERIALS, LABOUR, T&P ETC. REQUIRED FOR PROPER
COMPLETION OF THE WORK.
1016 SAME AS ITEM 1015 BUT IN PROPORTION OF 6:3:1. Cum. 7386.74
1017 SAME AS ITEM 1015 BUT IN PROPORTION OF 8:4:1. Cum. 7091.39
1018 COST OF REINFORCED CEMENT CONCRETE DOOR SILLS, CHAUKHATS,
BOUNARY POSTS, SHELVES AND SIMILAR SMALL WORKS WITH CEMENT,
COARSE SAND AND 20 MM GAUGE APPROVED STONE BALLAST IN THE
PROPORTION OF 1:2:4 EXCLUDING SUPPLY OF REINFORCEMENT AND ITS
BENDING BUT INCLUDING ITS FIXING AND BINDING THE SAME WITH 0.50 Cum. 10019.66
MM THICK BINDING WIRE AND THE COST OF BINDING WIRE AND THE
MOULDS AND ALL OTHER MATERIALS, LABOUR, T&P ETC. REQUIRED FOR
PROPER COMPLETION OF THE WORK.
1029 1ST CLASS BRICK-WORK IN 1:6 CEMENT AND LOCAL SAND MORTAR IN
FOUNDATION & PLINTH INCLUDING SUPPLY OF ALL MATERIALS, LABOUR,
Cum. 5966.03
T&P ETC. REQUIRED FOR PROPER COMPLETION OF THE WORK.
1030 SAME AS ITEM 1029 ABOVE BUT IN 1:5 CEMENT AND LOCAL SAND
Cum. 6013.23
MORTAR.
1031 SAME AS ITEM 1029 ABOVE BUT IN 1:4 CEMENT AND COURSE SAND
Cum. 6605.17
MORTAR.
1032 SAME AS ITEM 1029 ABOVE BUT IN 1:3 CEMENT AND LOCAL SAND
Cum. 6302.96
MORTAR.
1033 SAME AS ITEM 1029 ABOVE BUT IN 1:3 CEMENT AND COARSE SAND
Cum. 6569.08
MORTAR.
1034 1ST CLASS BRICK WORK IN MUD MORTAR IN FOUNDATION AND PLINTH
INCLUDING SUPPLY OF ALL MATERIALS, LABOUR, T&P ETC. REQUIRED FOR Cum. 5346.38
PROPER COMPLETION OF THE WORK.
1035 SAME AS ITEMS 1027 TO 1034 ABOVE BUT IN SUPER STRUCTURE INCLUDING
NECESSARY CUTTING & MOULDING OF BRICKS AS REQUIRED AND ALSO
INCLUDING HONEY COMB BRICK WORK, THICKNESS OF WALL NOT TO BE Cum. 318.29
LESS THAN 1.5 BRICK (EXTRA ON ITEMS 1027 TO 1034).
1036 SAME AS ITEMS 1027 TO 1034 ABOVE BUT FOR ONE-BRICK THICK WALL
Cum. 318.29
(EXTRA ON ITEM 1035).
1037 SAME AS ITEMS 1027 TO 1034 ABOVE BUT FOR FOR WALLS UP TO HALF
Cum. 318.29
BRICK THICK (EXTRA ON ITEM 1036).
1038 FOR SECOND CLASS BRICK WORK (DEDUCT FROM ITEMS 1027 TO 1036).
Cum. 439.45
1039 FOR THIRD CLASS BRICK WORK IN MUD (DEDUCT FROM ITEMS 1034 TO
Cum. 749.65
1036).
1040 SUNDRIED BRICK WORK IN MUD MORTAR IN FOUNDATION AND PLINTH
INCLUDING SUPPLY OF ALL MATERIALS, LABOUR, T&P ETC. REQUIRED FOR Cum. 4258.46
PROPER COMPLETION OF THE WORK.
1041 1ST CLASS BRICK WORK IN ARCHES (EXTRA ON ITEMS 1027 TO 1036). Cum. 773.16
1042 SAME AS ITEM 1041 BUT IN JACK ARCHES (EXTRA ON ITEMS 1027 TO 1033).
Cum. 852.60
1043 SAME AS ITEM 1041 BUT IN WELL STEINING WITH ORDINARY BRICKS (EXTRA
Cum. 1013.13
ON ITEMS 1027 TO 1033).
1044 SAME AS ITEM 1043 BUT WITH SPECIALLY MOULDED BRICKS (EXTRA ON ITEM
Cum. 1128.05
1043).
1045 11.5 CM STRING OR DRIP COURSE OF 1ST CLASS BRICK IN KANKAR LIME
INCLUDING LIME PLASTERING, CUTTING, DRIP NOTCH AS REQUIRED AND
/RM 457.09
SUPPLY OF ALL MATERIALS, LABOUR, T&P ETC. REQUIRED FOR PROPER
COMPLETION OF THE WORK.
1046 SAME AS ITEM NO. 1045 BUT IN 1:6 CEMENT AND LOCAL SAND /RM 375.17
1047 SAME AS ITEM 1045 BUT IN 23 CM CORNICE IN KANKAR LIME WITH LIME
/RM 322.37
PLASTER.
1048 SAME AS ITEM 1047 BUT IN 1:6 CEMENT AND LOCAL SAND INCLUDING
/RM 280.98
PLASTERING IN 1:6 CEMENT AND SAND MORTAR.
1049 EXTRA FOR CUTTING OF BRICKS FOR MOULDING AS REQUIRED FOR
CORNICE ETC. INCLUDING RUBBED FINISH NOT EXCEEDING 100 MM /RM 106.90
WIDTH (LABOUR ONLY).
1050 MAKING OPENING THROUGH WALLS IN LIME OR CEMENT MORTAR FOR
DOORS AND WINDOWS OR ENLARGING EXISTING OPENING OR CUTTING
OUT BRICK WORK FOR UNDER PINNING INCLUDING NECESSARY SUPPORTS Cum. 2374.38
STAGING, CLEANING SITE AND STACKING THE DISMANTLED MATERIALS AT
THE PLACE WITHIN A DISTANCE OF 50 M.
1051 REINFORCED BRICK WORK IN SUN SHADE WITH 1ST CLASS BRICKS LAID IN
CEMENT & COARSE-SAND MORTAR 1:3 EXCLUDING SUPPLY OF
REINFORCEMENT AND ITS BENDING BUT INCLUDING ITS FIXING IN POSITION Cum. 9239.91
WITH CENTERING, SHUTTERING, CURING, SUPPLY OF ALL MATERIALS,
LABOUR, T&P ETC. REQUIRED FOR PROPER COMPLETION OF THE WORK.
5. STONE WORK
1056 SUPPLY & FIX MIRZAPUR OR OTHER APPROVED FINE DRESSED STONE IN
DOOR SILLS, CHAUKHATS ETC. LAID IN CEMENT MORTAR CONSISTING OF
CEMENT & LOCAL SAND 1:6 INCLUDING SUPPLY OF ALL MATERIALS, Cum. 36166.20
LABOUR, T&P ETC. REQUIRED FOR PROPER COMPLETION OF THE WORK.
1057 SUPPLY & FIX MIRZAPUR OR OTHER APPROVED STONE SLABS 40 MM THICK
WITH PLAIN MOULDINGS ON EDGE AND FINE DRESSED ON ALL EXPOSED
SURFACES AS IN STEPS & SHELVES LAID IN CEMENT & LOCAL SAND /SQM 1180.08
MORTAR IN PROPORTION OF 1:6 INCLUDING SUPPLY OF ALL MATERIALS,
LABOUR, T&P ETC. REQUIRED FOR PROPER COMPLETION OF THE WORK.
1069 SUPPLY & FIX 40 MM THICK C. P. TEAK WOOD PART PANNELED AND PART
GLAZED DOORS & WINDOWS, SHUTTERS INCLUDING SUPPLY AND FIXING
OF WOODEN CLEATS AND STOP COCK AND FIXING AND ADJUSTMENT OF
HINGES, BOLTS. LOCKS, HANDLES, SPRINGS AND OTHER FITTINGS, SUPPLY /SQM 7173.11
AND FIXING THE GLASS PANES WITH PUTTY AND BRAD, GLASS TO BE 2.50
MM THICK, BUT EXCLUDING PAINTING AND SUPPLY OF FITTINGS.
1070 ADDITIONAL COST FOR FIXING GLASS-PANES WITH C.P. TEAK WOOD
BEADING AND FELT, INSTEAD OF WITH PUTTY AND BRAD INCLUDING COST
/SQM 621.18
OF ALL MATERIALS, LABOUR, T&P ETC. REQUIRED FOR PROPER
COMPLETION OF THE WORK.
1071 SUPPLY & FIX 40 MM THICK SHEESHAM WOOD FULLY PANELLED IN DOORS
& WINDOWS, SHUTTERS INCLUDING SUPPLY AND FIXING OF WOODEN
CLEATS AND STOP COCK AND FIXING AND ADJUSTMENT OF HINGES, /SQM 5773.46
BOLTS. LOCKS, HANDLES, SPRINGS AND OTHER FITTINGS, BUT EXCLUDING
PAINTING AND SUPPLY OF FITTINGS.
1072 SAME AS ITEM 1069 BUT FOR C.P. TEAK WOOD FULLY GLAZED (40 MM
/SQM 9793.81
THICK).
1073 SAME AS ITEM 1069 BUT FOR C.P. TEAK WOOD 35 MM THICK. /SQM 6740.98
1074 SAME AS ITEM 1071 BUT FOR C.P. TEAK WOOD 35 MM THICK. /SQM 5340.53
1075 SAME AS ITEM 1072 BUT FOR C.P. TEAK WOOD 35 MM THICK. /SQM 9547.63
1076 SAME AS ITEM 1069 BUT FOR C.P. TEAK WOOD 25 MM THICK. /SQM 6051.67
1077 SAME AS ITEM 1071 BUT FOR C.P. TEAK WOOD 25 MM THICK. /SQM 4171.23
1078 SAME AS ITEM 1072 BUT FOR C.P. TEAK WOOD 25 MM THICK. /SQM 8995.78
1079 SAME AS ITEM 1069 BUT FOR SHEESHAM WOOD 40 MM THICK. /SQM 5406.73
1080 SUPPLY & FIX 40 MM THICK SHEESHAM WOOD FULLY PANELLED IN DOORS
& WINDOWS, SHUTTERS INCLUDING SUPPLY AND FIXING OF WOODEN
CLEATS AND STOP COCK AND FIXING AND ADJUSTMENT OF HINGES, /SQM 3246.34
BOLTS. LOCKS, HANDLES, SPRINGS AND OTHER FITTINGS, BUT EXCLUDING
PAINTING AND SUPPLY OF FITTINGS.
1081 SUPPLY & FIX 40 MM THICK SHEESHAM WOOD FULLY GLAZED IN DOORS &
WINDOWS, SHUTTERS INCLUDING SUPPLY AND FIXING OF WOODEN
CLEATS AND STOP COCK AND FIXING AND ADJUSTMENT OF HINGES,
BOLTS. LOCKS, HANDLES, SPRINGS AND OTHER FITTINGS, SUPPLY AND /SQM 8526.66
FIXING THE GLASS PANES WITH PUTTY AND BRAD, GLASS TO BE 2.50 MM
THICK, BUT EXCLUDING PAINTING AND SUPPLY OF FITTINGS.
1082 SAME AS ITEM 1079 BUT FOR SHEESHAM WOOD 35 MM THICK. /SQM 5228.04
1083 SAME AS ITEM 1080 BUT FOR SHEESHAM WOOD 35 MM THICK. /SQM 3065.41
1084 SAME AS ITEM 1081 BUT FOR SHEESHAM WOOD 35 MM THICK. /SQM 8426.17
1085 SAME AS ITEM 1069 BUT FOR SAL WOOL 40 MM THICK. /SQM 6330.78
1086 SAME AS ITEM 1071 BUT FOR SAL WOOD 40 MM THICK. /SQM 4561.11
1087 SAME AS ITEM 1072 BUT FOR SAL WOOD 40 MM THICK. /SQM 9202.19
1088 SAME AS ITEM 1085 BUT FOR SAL WOOD 35 MM THICK. /SQM 6021.21
1089 SAME AS ITEM 1076 BUT FOR SAL WOOD 35 MM THICK. /SQM 4249.76
1090 SAME AS ITEM 1087 BUT FOR SAL WOOD 35 MM THICK. /SQM 9025.98
1091 SAME AS ITEM 1069 BUT FOR DEODAR WOOD 40 MM THICK. /SQM 6032.18
1092 SAME AS ITEM 1071 BUT FOR DEODAR WOOD 40 MM THICK. /SQM 4141.18
1093 SAME AS ITEM 1072 BUT FOR DEODAR WOOD 40 MM THICK. /SQM 8975.80
1094 SAME AS ITEM 1091 BUT FOR DEODAR WOOD 35 MM THICK. /SQM 5763.65
1095 SAME AS ITEM 1092 BUT FOR DEODAR WOOD 35 MM THICK. /SQM 3871.02
1096 SAME AS ITEM 1093 BUT FOR DEODAR WOOD 35 MM THICK. /SQM 8813.24
1097 SAME AS ITEM 1091 BUT FOR DEODAR WOOD 25 MM THICK. /SQM 5335.12
1098 SAME AS ITEM 1092 BUT FOR DEODAR WOOD 25 MM THICK. /SQM 3142.14
1099 SAME AS ITEM 1093 BUT FOR DEODAR WOOD 25 MM THICK. /SQM 8474.55
1100 SAME AS ITEM 1069 BUT FOR CHIR WOOD 40 MM THICK. /SQM 5647.36
1101 SAME AS ITEM 1071 BUT FOR CHIR WOOD 40 MM THICK. /SQM 3581.60
1102 SAME AS ITEM 1072 BUT FOR CHIR WOOD 40 MM THICK. /SQM 8712.37
1103 SAME AS ITEM 1100 BUT FOR CHIR WOOD 35 MM THICK. /SQM 5435.07
1104 SAME AS ITEM 1101 BUT FOR CHIR WOOD 35 MM THICK. /SQM 3367.92
1105 SAME AS ITEM 1102 BUT FOR CHIR WOOD 35 MM THICK. /SQM 8557.97
1106 SAME AS ITEM 1100 BUT FOR CHIR WOOD 25 MM THICK. /SQM 5097.08
1107 SAME AS ITEM 1101 BUT FOR CHIR WOOD 25 MM THICK. /SQM 2791.69
1108 SAME AS ITEM 1102 BUT FOR CHIR WOOD 25 MM THICK. /SQM 8292.24
1109 SAME AS ITEM 1069 BUT FOR KAIL WOOD 40 MM THICK. /SQM 6315.69
1110 SAME AS ITEM 1071 BUT FOR KAIL WOOD 40 MM THICK. /SQM 3962.63
1111 SAME AS ITEM 1072 BUT FOR KAIL WOOD 40 MM THICK. /SQM 8899.35
1112 SAME AS ITEM 1109 BUT FOR KAIL WOOD 35 MM THICK. /SQM 5661.64
1113 SAME AS ITEM 1110 BUT FOR KAIL WOOD 35 MM THICK. /SQM 3710.89
1114 SAME AS ITEM 1111 BUT FOR KAIL WOOD 35 MM THICK. /SQM 8757.67
1115 SAME AS ITEM 1109 BUT FOR KAIL WOOD 25 MM THICK. /SQM 5262.59
1116 SAME AS ITEM 1110 BUT FOR KAIL WOOD 25 MM THICK. /SQM 6850.22
1117 SAME AS ITEM 1111 BUT FOR KAIL WOOD 25 MM THICK. /SQM 8441.17
1118 SUPPLY OF 1 MM THICK SHEET IRON PANELLED DOOR & WINDOW
SHUTTERS IN 40 MM THICK SALWOOD FRAME INCLUDING SUPPLY AND
FIXING OF WOODEN CLEATS AND STOPS AND FIXING HINGES, BOLTS, /SQM 42893.18
LOCKS, HANDLES, SPRINGS, AND/ OR OTHER FITTINGS BUT EXCLUDING
SUPPLY OF FITTINGS.
1119 SUPPLY & FIXING OF 40 MM THICK C.P. TEAK WOOD DOOR & WINDOW
SHUTTERS WITH PANELS OF HEAVY QUALITY GALVANIZED IRON WIRE
GAUGE 2.5 MM OR 2.0 MM OR 1.5 MM MESH OR ANY OTHER SIZE WITH
NECESSARY BEADINGS INCLUDING SUPPLY AND FIXING OF WOODEN /SQM 3918.41
CLEATS AND STOPS AND INCLUDING FIXING AND ADJUSTMENTS OF
HINGES, BOLTS, LOCKS, HANDLES, SPRINGS, AND/ OR OTHER FITTINGS BUT
EXCLUDING SUPPLY OF FITTINGS.
1120 SAME AS ITEM 1119 BUT IN SHEESHAM WOOD 40 MM THICK. /SQM 2330.15
1121 SAME AS ITEM 1119 BUT IN SAL WOOD 40 MM THICK. /SQM 3150.72
1122 SAME AS ITEM 1119 BUT IN DEODAR WOOD 40 MM THICK. /SQM 2892.05
1123 SAME AS ITEM 1119 BUT IN CHIR WOOD 40 MM THICK. /SQM 2535.29
1124 SAME AS ITEM 1119 BUT IN KAIL WOOD 40 MM THICK. /SQM 2775.69
1125 SUPPLY OF GALVANIZED MOSQUITOE PROOF HEAVY QUALITY IRON WIRE
GAUGE 2.5 MM OR 2.0 MM OR 1.5 MM MESH OR ANY OTHER SIZE, OVER
WINDOWS INCLUDING SUPPLY OF C.P. TEAK WOOD BATTENS OF 50 MM X /SQM 619.33
12 MM AND NECESSARY SCREWS, ALL MATERIALS, LABOUR, T&P ETC.
REQUIRED FOR PROPER COMPLETION OF THE WORK.
1130 SAME AS ITEM 1129 BUT IN SAL WOOD 40 MM THICK. /SQM 5976.74
1131 SAME AS ITEM 1129 BUT IN COUNTRY WOOD 40 MM THICK. /SQM 2560.70
1132 SAME AS ITEM 1129 BUT IN DEODAR WOOD 40 MM THICK. /SQM 5333.42
1133 SAME AS ITEM 1129 BUT IN KAIL WOOD 40 MM THICK. /SQM 5051.73
1134 SAME AS ITEM 1129 BUT IN CHIR WOOD 40 MM THICK. /SQM 4469.71
1135 SUPPLY OF 40MM THICK C.P. TEAK WOOD DOOR & WINDOW SHUTTERS
WITH 9MM THICK 5 NOS. PLYWOOD OR PRESSED WOOD PANELS AND
FIXING C.P. TEAK WOOD CLEATS, STOPS, HINGES, LOCKS, BOLTS, HANDLES, /SQM 3934.10
SPRINGS ETC. & FOR OTHER FITTINGS (EXCLUDING SUPPLY OF ALL
FITTINGS).
1136 SAME AS ITEM 1135 BUT IN DEODAR WOOD 40 MM THICK. /SQM 2902.84
1137 SAME AS ITEM 1135 BUT IN SHEESHAM WOOD 40 MM THICK. /SQM 2336.11
1138 SAME AS ITEM 1135 BUT IN SAL WOOD 40 MM THICK. /SQM 3177.49
1139 SAME AS ITEM 1135 BUT IN KAIL WOOD 40 MM THICK. /SQM 2796.72
1140 SAME AS ITEM 1135 BUT IN CHIR WOOD 40 MM THICK. /SQM 2557.06
1141 SAME AS ITEM 1135 BUT IN COUNTRY WOOD 40 MM THICK. /SQM 1765.30
1142 APPROXIMATE COST OF IRON FITTINGS FOR DOORS & WINDOWS. L.S.
1143 APPROXIMATE COST OF OXIDIZED IRON FITTINGS FOR DOORS &
L.S.
WINDOWS.
1144 APPROXIMATE COST OF BRASS FITTINGS FOR DOORS & WINDOWS. L.S.
1145 APPROXIMATE COST OF OXIDISED BRASS FITTINGS FOR DOORS &
L.S.
WINDOWS.
7. MILD STEEL AND IRON WORK
1146 ROLLED STEEL JOISTS FIXED IN POSITION INCLUDING COST OF JOISTS BUT
INCLUDING ALL LABOUR IN HANDLING AND HOISTING ETC COMPLETE, QTL. 1374.80
LIGHT SECTION 0.0 - 7.5M HIGH.
1147 SAME AS IN ITEM 1146 , BUT FOR HEAVY SECTION, I.E., EXCEEDING 300 KG.
QTL. 2688.60
IN WEIGHT AND UP TO 7.5M IN HEIGHT.
1148 EXTRA ON ITEMS 1146 & 1147 FOR MORE THAN 7.5M HEIGHT. QTL. 844.82
1149 MILD STEEL OR IRON WORK OF SMALL SIZE & SECTIONS SUCH AS HOLDING
DOWN BOLTS, HOLD FASTS, TIE RODS, CLAMPS, GRATINGS ETC. (WHEN
NOT INCLUDED IN OVER ALL RATE) WROUGHT TO REQUIRED FORM QTL. 8155.08
INCLUDING SUPPLY OF STEEL, BOLTS, NUTS AND THEIR FIXING REQUIRED
FOR PROPER COMPLETION OF THE WORK.
1150 MILD STEEL OR IRON WORK IN HEAVY SIZES SUCH AS TRUSSES, BUILD UP
GATES, DOOR FRAMES, RECORD RACKS, ROOF WORK, GATES ETC.
WROUGHT TO REQUIRED FORM INCLUDING DRILLING HOLES, REVETTING QTL. 8703.40
OR WELDING, WHERE NECESSARY AND ALSO INCLUDING SUPPLY OF STEEL,
BOLTS, NUTS AND THEIR FIXING REQUIRED FOR PROPER COMPLETION OF
THE WORK.
1151 MILD STEEL OR IRON WORK IN PLAIN WORK SUCH AS R.C.C. OR R.B. WORK
(WHEN NOT INCLUDED IN OVER ALL RATES), WROUGHT TO REQUIRED
SHAPE, AS NECESSARY INCLUDING BENDING FOR PROPER COMPLETION QTL. 10900.46
OF WORK INCLUDING SUPPLY OF STEEL AND WASTAGE.
1152 CUTTING ROLLED STEEL JOISTS UPTO 225MM X 100MM. /CUT 264.03
1153 CUTTING ROLLED STEEL JOISTS ABOVE 225MM X 100MM. /CUT 528.07
1154 CUTTING OF PLATES & ANGLES UPTO 20MM THICK. /SQM 115.50
1155 CUTTING ROUNDS UPTO 15 MM DIA. /CUT 6.60
1156 BORING HOLES IN MILD STEEL OR IRON NOT EXCEEDING 10 MM DIA. &
/HOLE 35.64
THICKNESS OF PLATE NOT EXCEEDING 6 MM .
1157 SAME AS ITEM 1156 BUT HOLES EXCEEDING 10 MM DIA. BUT NOT
EXCEEDING 20 MM DIA. & THICKNESS EXCEEDING 6 MM BUT NOT /HOLE 56.67
EXCEEDING 13 MM.
1158 PROVIDE & FIX 100 MM DIA. C.I. DOWN PIPE COMPLETE WITH ROSE,
HEADS, BENDS WITH EYE HOLE AND GRATINGS ETC. FIXED TO WALLS WITH /RM 1329.25
SUITABLE CLAMPS.
1159 FIX BARBED IRON WIRE FENCING TO POSTS AFTER STRETCHING IT
INCLUDING LABOUR AND T&P ETC. REQUIRED FOR PROPER COMPLETION
/RM 61.97
OF THE WORK BUT EXCLUDING SUPPLY OF POSTS AND WIRE.
8. ROOF WORK
1160 SUPPLY & FIX SINGLE ALLAHABAD TILES WITH HIPS, RIDGES AND CAVES
AND INCLUDING LAYING THEM FOR ROOF WORK AND SETTING IN WHITE
LIME AND SURKHI (1:2) OR PURE KANKAR LIME AND ALSO INCLUDING /SQM 1788.97
SUPPLY AND LAYING OF WOODEN BATTENS AND WHITE WASHING TWO
COATS IN BOTTOM SURFACE OF TILES.
1161 SAME AS ITEM 1160 BUT FOR DOUBLE ALLAHABAD TILES ROOF. /SQM 2862.35
1162 SUPPLY & FIX LARGE COUNTRY TILES ROOFING ON BAMBOO FRAMES.
/SQM 3525.50
1163 SAME AS ITEM 1162 BUT SMALL SIZE COUNTRY TILES. /SQM 5056.70
1164 LAYING OF R.B. SLAB WITH 1ST CLASS BRICKS LAID IN CEMENT MORTAR
/SQM 10233.87
WITH APPROVED COARSE SAND (1:3).
1165 SUPPLY & FIX GALVANISED CORRUGATED IRON ROOFING 0.63MM THICK.
/SQM 1286.15
1166 SUPPLY & FIX 0.63MM THICK RIDGES, VALLEY & GUTTERS FOR G.C. IRON
/SQM 1541.29
ROOFING.
1167 SUPPLY & LAY 40MM THICK INSULATION LAYER OF SAND & CLAY OVER
/SQM 46.75
ROOF.
9. CEILING
1168 SUPPLY & LAY 25MM THICK DEODAR WOOD PLANK CEILING. /SQM 2355.47
1169 SAME AS ITEM 1168 BUT FOR C.P. TEAK WOOD. /SQM 3687.21
1170 SAME AS ITEM 1168 BUT FOR KAIL WOOD. /SQM 2208.45
1171 SUPPLY & FIX 6MM THICK A.C. PLANE SHEETS CEILING WITH 25MM X 40MM
/SQM 657.52
DEODAR WOOD BEADINGS.
1172 SAME AS ITEM 1171 BUT WITH C.P. TEAK WOOD BEADING. /SQM 728.34
1173 SAME AS ITEM 1171 BUT OF MASONITE OR CELOTAX WITH DEODAR
/SQM 806.24
BEADING.
1174 SAME AS ITEM 1173 BUT WITH C.P. TEAK WOOD BEADING. /SQM 877.01
10. PLASTER AND POINTING
1175 STRUCK POINTING WITH KANKAR LIME ON BRICK-WORK. /SQM 202.60
1176 SAME AS ITEM 1175 BUT FOR FLUSH POINTING. /SQM 164.73
1177 RUBBING WITH KANKAR LIME OR WITH WHITE LIME & SURKHI ON BRICK-
/SQM 107.14
WORK.
1178 STRUCK POINTING WITH CEMENT & LOCAL SAND (1:2) MORTAR. /SQM 207.49
1179 SAME AS ITEM 1178 BUT FLUSH POINTING (DEDUCT FROM ITEM 1178).
/SQM 29.77
1180 SAME AS ITEM 1178 & 1179 BUT IN FLOORS (DEDUCT FROM ITEMS 1178 &
/SQM 36.66
1179).
1181 RAISED POINTING WITH CEMENT & LOCAL SAND MORTAR (1:2) ON BRICK
/SQM 230.93
WORK.
1182 STRUCK CEMENT POINTING IN CEMENT MORTAR (1:2) WITH COLOURING
/SQM 221.71
MATERIALS.
1183 12MM THICK PLASTER WITH KANKAR LIME OVER BRICK-WORK. /SQM 179.63
1184 SAME AS ITEM 1183 BUT WITH CEMENT & LOCAL SAND (1:2) MORTAR.
/SQM 200.20
1185 12 MM THICK PLASTER WITH CEMENT & COARSE SAND (1:2) MORTAR.
/SQM 235.30
1186 12 MM THICK PLASTER WITH CEMENT & LOCAL SAND (1:3) MORTAR.
/SQM 177.69
1187 12 MM THICK PLASTER WITH CEMENT & COARSE-SAND MORTAR (1:3).
/SQM 207.18
1188 12 MM THICK PLASTER WITH CEMENT & COURSE SAND MORTAR (1:4).
/SQM 199.98
1189 12 MM THICK PLASTER WITH CEMENT AND LOCAL SAND MORTAR (1:5).
/SQM 164.11
1190 12 MM THICK PLASTER WITH CEMENT & LOCAL SAND MORTAR (1:6).
/SQM 157.31
1191 EXTRA ON ALL ITEM OF PLASTER IF DONE ON CEILING. /SQM 22.77
1192 SAME AS ITEM 1183 BUT WITH CEMENT, WHITE LIME & LOCAL SAND (1:1:6).
/SQM 189.19
1193 MUD-PLASTER OVER BRICK WALL. /SQM 75.36
1194 20 MM THICK STUCCO PLASTER RESEMBLING MARBLE FINISH. /SQM 843.11
1195 20MM THICK PLASTER ON WALLS, STEPS ETC. FINISHED WITH 5MM THICK
/SQM 1011.26
CEMENT & MARBLE CHIPS (1:2).
1196 SAME AS ITEM 1195 BUT FINISHED WITH 5MM THICK WHITE CEMENT &
/SQM 925.62
MARBLE CHIPS.
1197 SAME AS ITEM 1196 BUT WITH 5MM THICK TOP COAT COLOURED. /SQM 1028.75
1198 20MM THICK PEBBLE-DASH PLASTER. /SQM 417.23
1199 ROUGH CAST FINISH TO PLASTER OF DIFFERENT MORTARS (EXTRA TO
/SQM 85.40
PLASTER ITEMS).
1200 PLASTER OVER ROUGH FACE OF ONE BRICK WALL (EXTRA TO PLASTER
/SQM 28.77
ITEMS).
1201 20MM THICK CEMENT PLASTER IN DADO OR SKIRTING. /SQM 517.56
11. FLOORING
1202 25MM THICK 1:2:4 P.C.C. FLOOR WITH CEMENT, COARSE SAND AND
20MM GAUGE STONE BALLAST WITH BASE CONCRETE (75MM THICK) 1:4:8
/SQM 618.05
CEMENT, LOCAL SAND & BRICK BALLAST 40MM GAUGE.
1203 SAME AS ITEM 1202 BUT WITH BASE CONCRETE CONSISTING OF BRICK
/SQM 631.80
BALLAST, WHITE LIME & SURKHI 100:16:32.
1204 SAME AS ITEM 1202 BUT WITH BASE CONCRETE CONSISTING OF BRICK
/SQM 623.96
BALLAST, WHITE LIME & SAND MORTAR (1:2).
1205 SAME AS ITEM 1202 BUT WITH 50MM THICK 1:1.5:3 P.C.C. FLOOR. /SQM 905.25
1206 40MM THICK 1:2:4 P.C.C. FLOOR WITH CEMENT, COARSE SAND AND
/SQM 448.32
20MM GAUGE STONE BALLAST WITHOUT BASE CONCRETE.
1207 EXTRA ON ITEMS 1202, 1205 & 1206 WHEN FLOORS ARE POLISHED. /SQM 368.10
1208 EXTRA ON ITEMS 1202, 1205 & 1206 WHEN COLOURED, POLISHED FLOORS
/SQM 444.13
ARE LAID.
1209 STONE FLOORS 40MM THICK OF MIRZAPUR OR OTHER APPROVED STONE
/SQM 1973.39
FLAGS, SET IN WHITE LIME & SAND.
1210 SAME AS ITEM 1209 BUT STONE FLAGS LAID IN (1:4) CEMENT & LOCAL
/SQM 1899.41
SAND MORTAR.
1211 SAME AS ITEM 1209 BUT STONE FLAGS LAID IN WHITE LIME & SURKHI 1:2 &
BASE CONCRETE WITH BRICK BALLAST, WHITE LIME & SURKHI (1:2). /SQM 1940.07
1212 SAME AS ITEMS 1209, 1210, 1211 BUT UPPER SURFACE & EDGES CHIESEL
DRESSED & JOINT UPTO 6MM THICK IN WHITE LIME & SAND. /SQM 1941.34
1213 SAME AS ITEM 1212 BUT IN CEMENT & SAND. /SQM 1845.83
1214 SAME AS ITEM 1212 BUT BASE CONCRETE IN WHITE LIME & SURKHI. /SQM 1913.40
1215 1ST CLASS BRICK FLOOR LAID IN CEMENT & LOCAL SAND MORTAR (1:6) &
POINTED WITH (1:2) CEMENT MORTAR OVER 75MM THICK BASE CONCRETE /SQM 1091.81
WITH KANKAR LIME.
1216 SAME AS ITEM 1215 BUT WITH 75MM BASE CONCRETE WITH (1:2) WHITE
/SQM 1076.32
LIME & SURKHI.
1217 SAME AS ITEM 1215 BUT WITH 75MM BASE CONCRETE IN (1:4:8) CEMENT,
/SQM 1110.18
LOCAL SAND & BRICK BALLAST.
1218 1ST CLASS BRICKS FLOOR LAID DRY, JOINTS SAND FILLED. /SQM 582.40
1219 GRANOLYTHIC MARBLE FLOORING 25MM THICK WITH 20MM THICK LAYER
OF CEMENT & COARSE SAND & 12 MM GAUGE STONE CHIPS WITH
SURFACE COAT OF ORDINARY CEMENT INCLUDING 75MM THICK BASE /SQM 1402.87
CONCRETE WITH WHITE LIME & SAND.
1220 SAME AS ITEM 1219 BUT WITH WHITE CEMENT IN TOP LAYER. /SQM 1435.57
1221 SAME AS ITEM 1219 BUT WITH COLOURED FLOOR. /SQM 1504.12
\ SAME AS ITEM 1219 BUT BASE CONCRETE IN (1:4:8) CEMENT, LOCAL SAND
/SQM 1388.46
AND BRICK BALLAST.
1223 SAME AS ITEM 1220 BUT BASE CONCRETE IN (1:4:8) CEMENT, LOCAL SAND
/SQM 1430.23
AND BRICK BALLAST.
1224 SAME AS ITEM 1221 BUT BASE CONCRETE IN (1:4:8) CEMENT, LOCAL SAND
/SQM 1500.24
AND BRICK BALLAST.
1225 SAME AS ITEM 1219 BUT BASE CONCRETE IN WHITE LIME & SURKHI (1:2)
/SQM 1405.81
(EXTRA ON ITEM 1219).
1226 SAME AS ITEM 1220 BUT BASE CONCRETE IN WHITE LIME & SURKHI (1:2)
/SQM 1427.22
(EXTRA ON ITEM 1220).
1227 SAME AS ITEM 1221 BUT BASE CONCRETE IN WHITE LIME & SURKHI (1:2)
/SQM 1496.77
(EXTRA ON ITEM 1221).
1228 GRANOLYTHIC MARBLE DADO 20MM THICK WITH 14MM THICK LAYER OF
CEMENT & COARSE SAND (1:2) WITH 6MM THICK SURFACE COAT OF /SQM 1134.49
ORDINARY CEMENT.
1229 SAME AS ITEM 1228 BUT WITH WHITE CEMENT IN TOP COAT. /SQM 1179.47
1230 SAME AS ITEM 1228 BUT WITH COLOURED DADO. /SQM 1248.96
1231 SUPPLY AND FIXING OF 15X15CM CHINA WHITE GLAZED TILES 6MM THICK
IN FLOORING OR IN SKIRTING OR DADO LAID WITH (1:3) CEMENT & /SQM 2878.49
COARSE SAND.
12. PAINTING AND DISTEMPERING
1232 PAINTING OR VARNISHING ON NEW IRON WORK IN SMALL AREAS OR NEW
WOOD WORK WITH ONE COAT PRIMING & ONE COAT PAINT OR VARNISH. /SQM 98.62
1233 SAME AS ITEM 1232 BUT FOR EVERY COAT AFTER FIRST COAT. /SQM 61.55
1234 SAME AS ITEM 1233 BUT FOR EVERY COAT ON PREVIOUSLY PAINTED
/SQM 66.30
SURFACE.
1235 PAINTING ROOF OR OTHER IRON WORK IN LARGE AREA WITH ONE COAT
/SQM 103.42
PRIMING & ONE COAT PAINT OR VARNISH.
1236 SAME AS ITEM 1235 BUT FOR EVERY COAT AFTER FIRST COAT. /SQM 61.55
1237 SAME AS ITEM 1236 BUT FOR EVERY COAT OVER PREVIOUSLY PAINTED
/SQM 61.55
SURFACE.
1238 PAINTING OR VARNISHING WITH VALSPER OR HIGH GRADE ENAMEL OR
VARNISH ONE COAT OVER PREVIOUSLY PAINTED SURFACE. /SQM 86.58
1239 SAME AS ITEM 1238 BUT FOR EVERY SUBSEQUENT COAT ON PREVIOUSLY
/SQM 73.39
TREATED SURFACE WITH ENAMEL OR VARNISH.
1240 ONE PRIMING & ONE OIL DISTEMPER COAT ON NEW WORK. /SQM 105.14
1241 SAME AS ITEM 1240 BUT FOR EVERY COAT AFTER 1ST COAT. /SQM 61.03
1242 SAME AS ITEM 1241 BUT FOR EVERY COAT ON PREVIOUSLY DISTEMPERED
/SQM 65.46
SURFACE.
1243 ONE COAT OF HOT COALTAR ON NEW SURFACE. /SQM 29.46
1244 SAME AS ITEM 1243 BUT FOR EVERY COAT AFTER 1ST COAT. /SQM 18.37
1245 ONE COAT SOLIGNUM OR OTHER PRESERVATIVE ON NEW WOOD WORK.
/SQM 50.32
1246 SAME AS ITEM 1245 BUT FOR EVERY COAT AFTER FIRST COAT ON
/SQM 31.88
PREVIOUSLY TREATED SURFACE.
1247 OILING WOOD WORK WITH DOUBLE BOILED LINSEED OIL. /SQM 18.72
1248 REMOVING PAINT OR VARNISHING WITH PAINT REMOVER OR CAUSTIC
/SQM 33.41
SODA.
1249 WAX POLISHING OVER NEW WOOD WORK WUTH READY MADE POLISH
/SQM 54.44
AFTER RUBBING DOWN WITH SAND PAPER.
1250 SAME AS ITEM 1249 BUT REPOLISHING WOOD WORK ALREADY WAX
/SQM 32.24
POLISHED WITH READY MADE WAX POLISH.
13. WHITE WASHING AND COLOUR WASHING
1251 WHITE WASHING ONE COAT. /SQM 8.16
1252 SAME AS ITEM 1251 BUT TWO COATS. /SQM 12.08
1253 SAME AS ITEM 1251 BUT THREE COATS. /SQM 19.06
1254 COLOUR WASHING ONE COAT USING COLORING MATERIALS OF BUFF
/SQM 15.19
BLUE, BROWN SHADE.
1255 SAME AS ITEM 1254 BUT TWO COATS. /SQM 27.75
1256 SAME AS ITEM 1254 BUT USING COLOURING MATERIALS OF PINK, GREEN
/SQM 17.24
OR YELLOW SHADE.
1257 SAME AS ITEM 1256 BUT TWO COATS. /SQM 31.29
1258 COLOUR WASHING ONE COAT USING COPPER OR IRON SULPHATE. /SQM 17.85
1259 SAME AS ITEM 1258 BUT TWO COATS. /SQM 36.98
1260 CEMENT WASHING. /SQM 12.23
1261 ONE PRIMING COAT & ONE COAT OF DRY DISTEMPER ON NEW WORK.
/SQM 49.84
1262 SAME AS ITEM 1261 BUT FOR EACH COAT OF DISTEMPER AFTER FIRST COAT.
/SQM 29.37
1283 SAME AS ITEM 1282 BUT WITH OXIDISED IRON CLEATS. /NO. 178.17
1284 SUPPLY & FIX COTTON CORD FOR CLERESTORY WINDOW. /NO. 136.13
1285 SUPPLY & FIX C.P. TEAK WOOD CLEATS 100X75X50 MM TO C.P. TEAK
/NO. 331.65
DOORS & WINDOWS WITH BRASS HINGS 50MM.
1286 SUPPLY & FIX 100MM DIA. A.C. DOWN PIPES COMPLETE WITH ROSE,
HEADS, BENDS & GRATINGS WITH M.S. CLAMP 25X3MM FIXED TO WALLS &
/RM. 1325.08
SUPPLY OF 150MM LONG, 6MM DIA. NAILS, REPAIRS OF PLASTER, PAINTING
ETC. COMPLETE.
1287 SUPPLY & FIX C.P. TEAK WOOD PAG RACK 900X75X25MM WITH THREE
/NO. 1009.07
BRASS PEGS ON 75X75X120MM TEAK WOOD BLOCK.
1288 SUPPLY & FIX 40MM THICK C.P. TEAK WOOD PANNELLED PARTITION WITH
TEAK WOOD FRAMES 100X80MM TOP, BOTTOM & SIDE VERTICALS AT 1.5M /SQM 6486.44
APART.
1289 SUPPLY & FIX PLAIN ASBESTOS SHEET PARTITION WITH 50X10MM DEODAR
/SQM 2119.40
OR SHEESHAM WOOD BEADING, ERECTION & FIXING.
1290 SAME AS ITEM 1289 BUT WITH MASONITE PARTITIONS. /SQM 2188.03
16. ROAD WORK
1291 CONSOLIDATION OF 30 TO 40MM GUAGE KANKAR BY HAND RAMMER,
SORTING KANKAR INTO THREE SIZES REPAIRING PATCHES IN EXISTING
ROAD SURFACE WITH KANKAR, PICKING UP OLD SURFACE, SPREADING
KANKAR, MAKING MEDIS TO RETAIN WATER & RAMMING WITH CARRIAGE Cum. 571.56
OF MATEL & WATER AND MAINTENANCE OF BARRIERS, CAUTION POSTS,
LIGHTS ETC. (EXCLUDING SUPPLY OF KANKAR).
1292 SAME AS ITEM 1291 BUT FOR CONSOLIDATION BY ROAD ROLLER. Cum. 870.30
1293 SAME AS ITEM 1291 BUT FOR 120MM THICK COAT OF BRICK BALLAST.
Cum. 571.56
1294 SAME AS ITEM 1292 BUT FOR 80MM THICK COAT OF BRICK BALLAST. Cum. 870.30
1295 SAME AS ITEM 1292 BUT FOR 12MM THICK COAT OF BRICK BALLAST. Cum. 965.77
1296 SAME AS ITEM 1292 BUT 80MM THICK STONE BALLAST OVER EXISTING
Cum. 1172.37
KANKAR ROAD SURFACE.
1297 WATER ALLOWANCE ON ITEM 1291 TO 1296. Cum. 99.00
1298 DIGGING KANKAR INCLUDING BREAKING, CLEANING & ROLLING AND THE
Cum. 1290.64
COST OF BORING TO FIND KANKAR STRATA.
1299 MAKING MUD TREE GUARDS IM (I.D) & 1M HIGH ABOVE G.L. /NO. 765.39
1300 DUG BELLING 150MM DEEP IN ONE LINE ALIGNED WITH FLAGS &
/KM. 2574.00
JHANDIES.
1301 PAINTING WHITE TRAFFIC LINES 75MM WIDE IN THREE COATS WITH
/SQM 644.57
APPROVED WHITE PAINT.
1302 BRICK SOLING WITH STRAIGHT OVER BURNT BRICKS & DRY WITH BRICK
EDGING LAID VERTICAL ON EITHER SIDE, FILLING THE JOINTS WITH LOCAL /SQM 508.26
EARTH.
1303 RENEWING PARTIES 3M WIDE, DRESSING SURFACE, FILLING UP TO 8 CM
/RM. 56.67
DEPTH & MAKING PROFILES OF EVERY 15M APART.
1304 BRICK EDGING OF 1ST CLASS BRICKS LAID VERTICAL WITH MUD MORTAR.
/RM. 219.09
1305 STACKING OF ROAD METAL TO THE REQUIRED TEMPLATE AFTER
Cum. 142.92
SCREENING AT ROAD SIDE.
1306 BITUMEN PAINTING (LABOUR ONLY) OVER WATER BOUND SURFACE (1ST
/SQM 43.52
COAT) EXCLUDING SUPPLY OF PAINT & GRIT.
1307 SAME AS ITEM 1306 BUT SUBSEQUENT COATS OF PAINTING OVER
/SQM 21.76
PREVIOUSLY PAINTED SURFACE.
1308 SAME AS ITEM 1306 BUT WITH COLD EMULSION IN 2ND COAT. /SQM 38.23
1309 SAME AS ITEM 1306 BUT WITH TAR IN ONE COAT. /SQM 38.09
1310 SAME AS ITEM 1306 BUT WITH TAR IN 2ND COAT OR OTHER SUBSEQUENT
COATS OF PAINTING OVER PREVIOUSLY PAINTED SURFACE. /SQM 19.04
1322 SAME AS ITEM 1319 BUT ON WATER BOUND SURFACE. /SQM 65.62
1323 PROVIDE ALL MATERIALS, LABOUR,T & P ETC. & CONSTRUCT 100MM THICK
(1:2:4:) CEMENT CONCRETE ROAD FOR REINSTATEMENT OF PATCH &
/SQM 2519.04
TRENCH CUTS IN CEMENT CONCRETE ROAD.
1324 SAME AS ITEM 1323 BUT TWO COATS OF BITUMEN PAINTING INSTEAD OF
/SQM 1541.38
100MM THICK CEMENT CONCRETE CONCRETE LAYER.
1325 SAME AS ITEM 1323 BUT TWO EXCLUDING THE CEMENT CONCRETE SLAB.
/SQM 1123.94
1326 MAINTENANCE OF TERRACED ROOFS, FILLING UP CRACKS BEFORE RAINS
/SQM 91.48
WITH BITUMINOUS FILLER.
1327 REPAIR OF PLASTER OR POINTING IN PATCHES INCLUDING REMOVAL OF
25%
OLD PLASTER.
1328 REPAIRS OF FLOORING IN PATCHES INCLUDING DIGGING UPTO EXISTING
25%
THICKNESS OF FLOORS, RENEWING THE SAME.
1329 CLEANING OF WELL & THROWING OUT THE SILT TO THE PLACE AS DIRECTD
/RM. 1596.93
BY THE ENGINEER IN CHARGE.
1330 BLENDING PANES OF GLASS. /SQM 123.27
1331 RENEWING PANES OF GLASS 2.5MM THICK WITH PUTTY & BEADS. /SQM 752.26
1332 CLEANING DOORS & WINDOWS WITH ORDINARY OIL & WATER. /SQM 14.79
1333 FIXING PANES & GLASS INCLUDING PUTTY & BEADS (EXCLUDING COST OF
/SQM 298.30
GLASS).
1334 CLEANING PANES OF GLASS WITH SPRIT OR CAUSTIC SODA. /SQM 100.71
1335 LABOUR FOR FIXING DOOR BOLTS OR HINGES OR TOWER BOLTS OR HASP
EACH 22.00
& STRAPLES OR HANDLES ETC. TO DOORS & WINDOWS.
1336 OPENING & REFIXING 100MM DIA. RAIN WATER DOWN PIPE AFTER
/RM. 79.29
CLEANING.
1337 VARNISHING OR POLISHING FURNITURE WITH HIGH GRADE VARNISH OR
/NO. 123.12
POLISH AFTER SAND PAPERING.
EXTRA ANALYSIS
1338 Concrete with cement, coarse sand & 40 mm nominal size(20-40 mm)
stone ballast in proportion of 1:4:8 in foundations including supply of all
Cum. 6609.76
materials, labour, T&P etc. required for proper completion of the work.
1339 Ist class brick work in 1:6 cement & coarse sand mortar in foundation
and plinth including supply of all materials, labour, T&P etc. required for Cum. 6314.94
proper completion of the work.
1340 40 mm thick D.P.C. in cement concrete consisting of 1:2:4 cement,
coarse sand and graded stone aggregate 12.5 mm nominal size(10-12.5
mm) and including water proofing(ISI Mark) materials in the proportion as Sqm 395.97
specified by the manufacturer including supply of all materials, labour,
T&P etc. required for proper completion of the work.
1341 Plinth Plaster 15 mm thick with cement and coarse sand mortar in 1:4
Sqm 235.59
shall be done both side of brick work upto 15 cm below GL.
1342 First Class brick work in 1:6 cement and coarse sand mortar in super
structure including necessary cutting and moulding of bricks as required
and also including supply of materials, labour, T&P etc. required for Cum. 7264.46
proper completion of the work thickness of wall not be less than one
brick.
1343 12mm thick plaster with cement mortar in proportion of 1:6 consisting of
cement and Banda(Ken)/Hamirpur(Betava) fine sand (F.M. not less than
1.25) over brick work and also making 10 mm wide grove as per drawing Sqm 169.48
including supply of all materials, labour, T&P etc. required for proper
completion of the work.
1344 Cement concrete with cement, coarse sand & 20mm nominal size(10-20
mm) stone grit in proportion 1:2:4 including supply of all materials, labour,
T&P etc., required for proper completion of the work, in bed block of Cum. 8387.50
girder, hold fast and girder fixing and in bypass chamber flooring.
1345 R.C.C. work(with use of C.C. Mixer) in 1:1.5:3 proportion of cement,
coarse sand and 20mm nominal size(10-20 mm) stone grit including
supply of all materials, labour, T&P and shuttering excluding cost of steel
but binding the same with 24 B.W.G. binding wire as per specification of
P.W.D. Schedule.
For lintel Cum. 12493.76
For Slab Cum. 13743.14
For lighter Beam Cum. 14921.62
For Column Cum. 12493.76
1346 40mm thick 1:2:4 plain cement concrete floor with cement, coarse sand
and 40 mm nominal size(10-20 mm) stone ballast laid in panels finished
with 3mm floating coat of neat cement over the floors and including
75mm thick base concrete consisting of cement coarse sand and stone
ballast 40mm nominal size(20-40 mm) in proportion of 1:4:8 and Sqm 986.09
removing all over lapping of mortar at the joints of the panels if any and
giving them uniform finishing including supply of all materials, labour, T&P
etc. required for proper completion of the work
1347 6 mm thick plaster on ceiling, sun shade and R.C.C. work in 1:4 cement
and Banda/Hamirpur fine sand (F.M. not less than 1.25) including supply
Sqm 138.48
of all materials, labour, T&P etc., required for proper completion of the
work,
1348 20 mm thick plaster in dado or skirting with cement mortar in proportion
of 1:2 cement and coarse sand with finishing 3 mm thick floating coat of
Sqm 514.81
neat cement including supply of all materials, labour, T&P etc. required
for completion of the work.
1349 150 mm thick local sand filling under floor including supply of local sand,
filling, watering and ramming etc. complete for proper completion of Cum. 1105.28
the work.
1350 The outer surface of wall finish with two coat of weather coat-All Guard,
Apex-Ultima(Premium Acrylic Smooth Exterior Paint with Silicon Additive)
with one coat of priming coat of exterior primer over smooth base of
white cement based wall putty such as Birla, J.K. wall Putty over the Sqm 286.20
plastered wall surface to prepare the surface even and smooth
including supply of all materials, labour, T&P etc. required for proper
completion of the work.
1351 The inner finish should be two coat of oil bound distemper Ist quality such
as Bison distemper, tractor distemper with one coat of priming coat over
smooth base of cement based wall putty such as Birla, J.K. wall Putty Sqm 174.81
over the plastered wall surface to prepare the surface even and smooth
including supply of all materials, labour, T&P etc. required for proper
completion of the work.
1352 25 mm thick 1:2:4 plain cement concrete floor with cement, coarse sand
and 40 mm nominal size(20-40 mm) stone ballast laid in panels finished
with 3mm floating coat of neat cement over the floors and including
75mm thick base concrete consisting of cement coarse sand and stone
ballast 40mm nominal size(20-40 mm) in proportion of 1:4:8 and Sqm 938.24
removing all over lapping of mortar at the joints of the panels if any and
giving them uniform finishing including supply of all materials, labour, T&P
etc. required for proper completion of the work
1353 Engraving lines or making groves in the plaster both side as per drawing.
2005 SAME AS ITEM 2004 BUT FOR 20MM DIA. Rm. 102.22
2006 SAME AS ITEM 2004 BUT FOR 25MM DIA. Rm. 134.30
2007 SAME AS ITEM 2004 BUT FOR 32MM DIA. Rm. 156.65
2008 SAME AS ITEM 2004 BUT FOR 40MM DIA. Rm. 187.71
2009 CARTING FROM STORE, LAYING, JOINTING, FIXING & TESTING OF 15MM DIA.
(NOMINAL) M.S. GALVANIZED SCREWED & SOCKETTED PIPES (MEDIUM
Rm. 23.92
QUALITY),SPECIALS & FITTINGS (IN TRENCHES OUTSIDE HOUSES).
2010 SAME AS ITEM 2009 BUT FOR 20MM DIA. Rm. 34.60
2011 SAME AS ITEM 2009 BUT FOR 25MM DIA. Rm. 47.69
2012 SAME AS ITEM 2009 BUT FOR 32MM DIA. Rm. 57.81
2013 SAME AS ITEM 2009 BUT FOR 40MM DIA. Rm. 63.93
2014 SAME AS ITEM 2009 BUT FOR 50MM DIA. Rm. 74.48
2015 SAME AS ITEM 2009 BUT FOR 65MM DIA. Rm. 88.74
2016 SAME AS ITEM 2009 BUT FOR 80MM DIA. Rm. 107.81
2017 SAME AS ITEM 2009 BUT FOR 100MM DIA. Rm. 127.29
2018 SAME AS ITEM 2009 BUT FOR 125MM DIA. Rm. 140.13
2019 SAME AS ITEM 2009 BUT FOR 150MM DIA. Rm. 158.37
2020 CARTING FROM STORE, LAYING, JOINTING & TESTING 50 MM DIA. CLASS I & II
Rm. 23.76
A.C. PRESURE PIPE WITH FITTING ETC.
2021 SAME AS ITEM 2020 BUT 65 MM DIA. Rm. 29.47
2022 SAME AS ITEM 2020 BUT 80 MM DIA. Rm. 31.37
2023 SAME AS ITEM 2020 BUT 100MM DIA. Rm. 37.97
2024 SAME AS ITEM 2020 BUT 125MM DIA. Rm. 47.95
2025 SAME AS ITEM 2020 BUT 150MM DIA. Rm. 54.65
2026 SAME AS ITEM 2020 BUT 200MM DIA. Rm. 65.86
2027 SAME AS ITEM 2026 BUT 250MM DIA. Rm. 78.74
2028 SAME AS ITEM 2026 BUT 300MM DIA. Rm. 91.68
2029 SAME AS ITEM 2026 BUT 350MM DIA. Rm. 138.26
2030 SAME AS ITEM 2026 BUT 400MM DIA. Rm. 172.48
2031 SAME AS ITEM 2026 BUT 450MM DIA. Rm. 207.49
2032 SAME AS ITEM 2026 BUT 500MM DIA. Rm. 256.40
2033 SAME AS ITEM 2026 BUT 600MM DIA. Rm. 357.93
2034 SAME AS ITEM 2020 TO 2033 BUT CLASS III A.C. PIPE (EXTRA ON ITEMS 2020 TO
5.00%
2033).
2035 CARTING FROM STORE, LAYING, JOINTING, FIXING & TESTING 15 MM DIA.
Rm. 7.07
(I.D.) P.V.C. PIPES & SPECIALS.
2036 SAME AS ITEM 2035 BUT 20MM DIA. Rm. 8.62
2037 SAME AS ITEM 2035 BUT 25MM DIA. Rm. 9.42
2038 SAME AS ITEM 2035 BUT 32MM DIA. Rm. 11.40
2039 SAME AS ITEM 2035 BUT 40MM DIA. Rm. 12.96
2040 SAME AS ITEM 2035 BUT 50MM DIA. Rm. 19.53
2041 SAME AS ITEM 2035 BUT 65MM DIA. Rm. 26.48
2042 SAME AS ITEM 2035 BUT 80MM DIA. Rm. 32.69
2043 SAME AS ITEM 2035 BUT 100MM DIA. Rm. 36.27
2044 SAME AS ITEM 2035 BUT 125MM DIA. Rm. 39.51
2045 SAME AS ITEM 2035 BUT 150MM DIA. Rm. 50.82
2046 SAME AS ITEM 2035 BUT 180MM DIA. Rm. 56.78
2047 SAME AS ITEM 2035 BUT 200MM DIA. Rm. 58.76
2048 CARTING FROM STORE P1 QUALITY R.C.C. PRESSURE PIPES & SPECIALS 80MM
DIA., LAYING JOINTING, & TESTING WITH (1:1.5) CEMENT & SAND MORTAR Rm. 117.54
JOINTS.
2049 SAME AS ITEM 2048 BUT 100 MM DIA. Rm. 141.25
2050 SAME AS ITEM 2048 BUT 150 MM DIA. Rm. 172.58
2051 SAME AS ITEM 2048 BUT 250 MM DIA. Rm. 217.80
2052 SAME AS ITEM 2048 BUT 300 MM DIA. Rm. 246.97
2053 SAME AS ITEM 2048 BUT P2 QUALITY 80 MM DIA. PIPES. Rm. 117.54
2054 SAME AS ITEM 2049 BUT P2 QUALITY 100MM DIA. PIPES. Rm. 141.29
2055 SAME AS ITEM 2050 BUT P2 QUALITY 150MM DIA. PIPES. Rm. 172.58
2056 SAME AS ITEM 2055 BUT P2 QUALITY 250MM DIA. PIPES. Rm. 225.24
2057 SAME AS ITEM 2055 BUT P2 QUALITY 300MM DIA. PIPES. Rm. 266.51
2058 SAME AS ITEM 2055 BUT P2 QUALITY 350MM DIA. PIPES. Rm. 355.43
2059 SAME AS ITEM 2055 BUT P2 QUALITY 400MM DIA. PIPES. Rm. 414.48
2060 SAME AS ITEM 2055 BUT P2 QUALITY 450MM DIA. PIPES. Rm. 462.57
2061 SAME AS ITEM 2055 BUT P2 QUALITY 500MM DIA. PIPES. Rm. 548.42
2062 SAME AS ITEM 2055 BUT P2 QUALITY 600MM DIA. PIPES. Rm. 689.19
2063 SAME AS ITEM 2048 BUT P3 QUALITY 80 MM DIA. PIPES. Rm. 117.54
2064 SAME AS ITEM 2049 BUT P3 QUALITY 100MM DIA. PIPES. Rm. 141.25
2065 SAME AS ITEM 2050 BUT P3 QUALITY 150MM DIA. PIPES. Rm. 172.58
2066 SAME AS ITEM 2065 BUT 250MM DIA. PIPES. Rm. 236.33
2067 SAME AS ITEM 2065 BUT 300MM DIA. PIPES. Rm. 279.55
2068 SAME AS ITEM 2065 BUT 350MM DIA. PIPES. Rm. 374.26
2069 SAME AS ITEM 2065 BUT 400MM DIA. PIPES. Rm. 432.72
2070 CARTING OF C.I.S & S AND FLANGED (CLASS `LA' AND `A') PIPES & SPECIALS
FROM STORE, LAYING, JOINTING & TESTING ETC. 80MM DIA. Rm. 34.06
2307 SAME AS ITEM 2306 BUT 200 TO 300 MM DIA. Per Conn. 3713.64
2308 SAME AS ITEM 2306 BUT 350 TO 450 MM DIA. Per Conn. 6383.19
2309 SAME AS ITEM 2306 BUT 500 TO 600 MM DIA. Per Conn. 8040.08
2310 SAME AS ITEM 2306 BUT 700 TO 750 MM DIA. Per Conn. 10743.56
2311 SAME AS ITEM 2306 BUT 800 TO 1000 MM DIA. Per Conn. 15844.43
2312 SAME AS ITEM 2306 BUT 1100 TO 1200 MM DIA. Per Conn. 18887.70
2313 DISMANTLING 15 MM DIA. SCREWED & SOCKETED M.S. GALVANISED PIPES,
SPECIALS & FITTINGS INCLUDING TAKEN OUT FROM INTERNAL WORKS. /RM 51.60
400
G.L. 71.19 G.L. 71.19 G.L. 71.18 G.L. 71.18 G.L. 70.57 G.L. 70.57 G.L. 68.60 G.L. 68.60
R.C.C 1:1.5:3 R.C.C 1:1.5:3 R.C.C 1:1.5:3 100 MM THK.
500
W.L. 68.24
600
INLET 100 MM THK. INLET FOOT REST
100 MM THK. FOOT REST FOOT REST INLET FOOT REST FOOT REST
OVER FLOW >>>
W.L. 70.62 I.L. 68.20 W.L. 68.14 W.L. 68.14
DRAIN >>> I.L. 70.69
W.L. 70.73 OVER FLOW >>> DRAIN >>> OVER FLOW >>> DRAIN >>> I.L. 68.10
I.L. 70.59
W.L. 70.63 W.L. 70.63 I.L. 70.58 W.L. 70.52 W.L. 68.04
1320
W.L. 70.53 W.L. 70.52
1200
I.L. 70.48 W.L. 70.42
SILT CHAMBER INLET
R.C.C 1:1.5:3 SILT CHAMBER
600
DRAIN >>> I.L. I.L. BRICK WALL
I.L. I.L. BRICK WALL 100 MM THK. 67.40
2300
69.99 69.99 230 MM THK. I.L. W.L. 69.29 67.40 230 MM THK.
2520
69.88 SILT CHAMBER OVER FLOW >>> P.C.C 1:2:4 P.C.C 1:4:8
P.C.C 1:2:4 P.C.C 1:4:8 I.L. 69.25 W.L. 69.19 W.L. 69.19 150 MM THK. 100 MM THK.
150 MM THK. 100 MM THK. P.C.C 1:2:4 P.C.C 1:4:8 I.L. 69.15 W.L. 69.09
150 MM THK. 100 MM THK. BRICK WALL
230 MM THK. BRICK WALL
P.C.C 1:2:4 P.C.C 1:4:8 I.L. 230 MM THK. P.C.C 1:2:4 P.C.C 1:4:8
150 MM THK. 100 MM THK. 68.55 SILT CHAMBER 150 MM THK. 100 MM THK.
I.L. P.C.C 1:2:4 P.C.C 1:4:8
68.88
TAPING OF NALA SECTION-AT POINT "A" 150 MM THK. 100 MM THK. I.L.
TAPING OF NALA SECTION-AT POINT "B" 68.05
TAPING OF NALA SECTION-AT POINT "D"
P.C.C 1:2:4 P.C.C 1:4:8 TAPING OF NALA SECTION-AT POINT "C"
150 MM THK. 100 MM THK. P.C.C 1:2:4 P.C.C 1:4:8 600 Ø
150 MM THK. 100 MM THK. MANUAL PERFORATED MANHOLE
SCREEN SLAB COVER SLAB 100 MM THK
230
600 Ø
PERFORATED MANHOLE
MANUAL
SCREEN SLAB COVER SLAB 100 MM THK
230
600 Ø 600 Ø
MANUAL PERFORATED MANHOLE MANUAL PERFORATED MANHOLE
SCREEN SLAB COVER SLAB 100 MM THK SCREEN SLAB COVER SLAB 100 MM THK
2100
230
230
INLET OVER FLOW >>>
DRAIN >>>
1200
INLET OVER FLOW >>>
DRAIN >>>
230
230
BRICK WALL
1200
INLET INLET
1300
OVER FLOW >>> OVER FLOW >>>
DRAIN >>> DRAIN >>> 230 MM THK. BRICK WALL
200 MM Ø
R.C.C PIPE 230 MM THK.
230
230
200 MM Ø
500 820 1000 1500 1500 R.C.C PIPE
600 Ø MANHOLE
600 Ø MANHOLE PERFORATED COVER
PERFORATED COVER MANUAL SLAB SLAB 100 MM THK
MANUAL SLAB SLAB 100 MM THK 600 Ø MANHOLE SCREEN
PERFORATED 600 Ø MANHOLE
SCREEN PERFORATED COVER MANUAL SLAB COVER SLAB 100 MM THK
MANUAL SLAB SLAB 100 MM THK SCREEN G.L. 70.55 G.L. 70.55
G.L. 72.03 G.L. 72.03 SCREEN
G.L. 71.15 G.L. 71.15
FOOT REST FOOT REST G.L. 72.56 G.L. 72.56
INLET
1060
R.C.C 1:1.5:3
DRAIN >>> INLET INLET
100 MM THK.
950
1820
I.L. 70.87 70.91 W.L. 70.91 W.L. 71.63
W.L. 70.81 OVER FLOW >>>
2160
1900
2930
I.L. 71.61 W.L. 71.53
I.L. 71.51 W.L. 71.53
BRICK WALL W.L. 71.43 INLET
2850
I.L. 230 MM THK. R.C.C 1:1.5:3 DRAIN >>>
70.27 SILT CHAMBER BRICK WALL 100 MM THK. R.C.C 1:1.5:3
3900
P.C.C 1:2:4 P.C.C 1:4:8 I.L. 230 MM THK. W.L. 100 MM THK.
I.L. 70.91 SILT CHAMBER 69.37 W.L. OVER FLOW >>>
150 MM THK. 100 MM THK. I.L. I.L. 69.33 69.27 W.L. 69.27
69.87 P.C.C 1:2:4 P.C.C 1:4:8 I.L. 69.23 W.L. 69.17
150 MM THK. 100 MM THK. 70.66
600
BRICK WALL
I.L. 230 MM THK. W.L.
P.C.C 1:2:4 68.63 SILT CHAMBER W.L. OVER FLOW >>>
P.C.C 1:2:4 150 MM THK. P.C.C 1:2:4 P.C.C 1:4:8 I.L. 67.62 67.66
W.L. 67.56
P.C.C 1:4:8 P.C.C 1:4:8 I.L. I.L. 67.52 67.56
TAPING OF NALA SECTION-AT POINT "E" 150 MM THK. 100 MM THK. 150 MM THK. 100 MM THK. W.L. 67.46
100 MM THK. 68.30
600
TAPING OF NALA SECTION-AT POINT "F" TAPING OF NALA SECTION-AT POINT "G" I.L.
BRICK WALL
230 MM THK.
66.92SILT CHAMBER
600 Ø P.C.C 1:2:4 P.C.C 1:4:8 I.L.
PERFORATED MANHOLE P.C.C 1:2:4 P.C.C 1:4:8 150 MM THK. 100 MM THK. 66.65
MANUAL 150 MM THK. 100 MM THK.
SCREEN SLAB COVER SLAB 100 MM THK
230
230
SCREEN COVER SLAB 100 MM THK 600 Ø
1200
INLET
230
230
230
BRICK WALL
1200
INLET OVER FLOW >>>
230 MM THK. DRAIN >>>
200 MM Ø
R.C.C PIPE
230
500 606 1000 1500 1500
2000
1500
BRICK WALL INLET OVER FLOW >>>
DRAIN >>> 230 230 230
230 MM THK. DRAIN >>>
200 MM Ø
TAPING OF NALA PLAN-AT POINT "F" R.C.C PIPE
230
500 1109 1000 1500 1500
230
BRICK WALL
230 MM THK.
200 MM Ø
R.C.C PIPE
4000
4000
40MM MS TUBE 40MM MS TUBE
RAILING 0.50 M RAILING 0.50 M
HIGHT SLAB 300 MM THK. HIGHT SLAB 300 MM THK.
GL. 100.20 OPEN AREA GL. 100.20 GL. 97.02 OPEN AREA GL. 97.02
1.0 M WIDE 1.0 M WIDE
1500
1500
BEAM BEAM
450X300 450X300
VALVE VALVE
CHAMBER IL. 95.52 CHAMBER
IL. 93.40
7720
IL. 95.87
R.C.C M 30 RISING MAIN IPS TO MPS
WALL THK. 400 MM
IL. 92.18
TWL. 95.62
TWL. 91.93
GRAVITY MAIN MH TO MPS
IL. 89.80
P.C.C BOTTOM
PLUGGING IN M25
OVER 900 MM THICK P.C.C BOTTOM
BOLDER FILLING PLUGGING IN M25
OVER 1000 MM THICK
BOLDER FILLING
TYPICAL SECTION TYPICAL SECTION
COLUMN COLUMN
300X300 300X300
0
0
50
50
Ø4
Ø4
CHAMBER
VALVE
NOTES:-
PIPING PLAN PIPING PLAN 1. ALL DIMENSIONS ARE IN mm. UNLESS OTHERWISE SPECIFIED.
2. DO NOT SCALE WORK, TO WRITTEN DIMENSIONS ONLY.
IPS MPS TITLE GA OF SCREEN CHANNEL & WET WELL (IPS & MPS)
12000
2500
PORTABLE
BIO-TOILET
CHAMBER
VALVE
SUMP WELL
3000
(IPS)
PUMP
HOUSE
9000
3000X3000
DG PLATFORM
5000X3000 (M)
ENTRY GATE
LAND REQUIREMENT FOR IPS-1 NOTES:-
1. ALL DIMENSIONS ARE IN mm. UNLESS OTHERWISE SPECIFIED.
2. DO NOT SCALE WORK, TO WRITTEN DIMENSIONS ONLY.
WORK
ANGLE IRON (35X35X4)
IN
1800
1380
PROGRESS
800
1800
1380
1380
MS FLAT (125X4)
FRONT FACE
00
15 DETAILS OF MS BARRICADING
750 SIZE 1800X1500
TITLE
110 120
ROAD LEVEL
100
200
PCC 1:2:4
SPINDLE
SLUICE VALVE
PIPE
500
PCC 1:4:8
100
A A'
500
230
100
PLAN
TYPE DESIGN :
200
RCC 1:2:4
230
230
70 70
PCC 1:4:8
75
SECTION AT A-A'
MANHOLE COVER
PERFORATED
950
810
A A'
810
950
PLAN
TYPE DESIGN :
CHAMBER FOR AIR VALVE
2500 2500
BARBED WIRE 4 LINE BARBED WIRE 4 LINE
600
3 BARS-12 Ø
75
300
75 MM THICK IN 1:1.5:3 R.C.C BEAM
12mm /15mm thick
1500
8 Ø stirrups @ 200 c/c plaster in 1:6 cm
250
R.C.C COLUMN
250X250 IN 1:1.5:3
BRICK WORK IN 1:6 CM
40
PLINTH LEVEL
250 300
250
150 400
3 BARS- 12 Ø GROUND LEVEL
SECTIONAL PLAN OF R.C.C. COLUMN 250X250
900
1000
300
150
100 MM P.C.C 1:4:8
750
12 Ø
8Østirrups@200c/c
FRONT ELEVATION BOUNDARY WALL
250
8 Ø @175 c/c bothway
2 - 12 Ø
250 750
150 MM R.C.C. 1:1.5:3 250
3 - 12 Ø
NOTES:-
250 1. ALL DIMENSIONS ARE IN mm. UNLESS OTHERWISE SPECIFIED.
150 MM R.C.C. 1:1.5:3 2. DO NOT SCALE WORK, TO WRITTEN DIMENSIONS ONLY.
SECTION OF BEAM (B 1)
100 MM P.C.C. 1:4:8 750
TITLE BOUNDARY WALL (PART-1)
PLAN OF FOOTING
100 MM P.C.C. 1:4:8
MS. SHEET 2MM THICK F. I. STOPPER (REF. DETAIL.) 40mm TH. COPING
12MM BAR@ 125MM C/C WITH 1:2:4 C.C
ANGLE IRON 50 X 50 X 6 MM
750
70 70
BRICK WORK IN 1 :4 CM
400
G.L
1500
600 375
715 250
M S BASE PLATE 300X250X8MM 825 250
ROAD LEVEL GROUTED IN P.C.C. WITH BOLTS
1000 MONKEY TAIL BOLT (REF DETAIL) 10 150 MM P.C.C 1 : 4 : 8
25mm GROOVE EQUAL EQUAL 75MM FLAT BRICK SOILING 325
100MM SAND FILLING
600
ELEVATION 1050
(REF DETAIL)
200
@ 125 C/C 715
15
370
600
ISMC 100 ISMC200
100
WICKET GATE
370 1000 EQUAL EQUAL
1500 600
4000
OUT SIDE
1950
PLAN R.C.C. COLUMN
M-20 (200X200)
1500
BRICK WORK IN 1 :4 CM
370 ISMC 100
25 Ø GI.PIPE EMBEDDED IN
12 MS BAR VERTICAL
RCC POST TO RECEIVE THE ALDROP
BOLT FOUNDATION PLAN OF MAIN GATE PILLAR
G.L 300 X 200 X 6 mm TH. 50 X 50 X 6 MS. ANGLE
300 375
460
200
875
1000
DETAILS OF FOUNDATION WICKET GATE PILLAR COLUMN 200 X200
1000 ELEVATION
700 LOCKING ARRANGEMENT OF
460
370 WICKET GATE FROM IN SIDE
SCALE :- NOT TO SCALE
NOTES:-
1000
2050
230
FOOT RESET
400 CC C.I.
750
350
2100
PLASTER IN 460
1:2:4 CEMENT G.L C.M.1:4
CONCRETE
1950
230
FOOT RESET
400 CC C.I.
FRCS FRAME AND COVER 560Ø
12 CEMENT
750
INTERNAL (HEAVY TYPE)
PLASTER IN 350
C.M.1:4
4050
INTERNAL (HEAVY TYPE) CONCRETE BRICK
MASONRY IN
CEMENT
MORTAR 1:4
1:2:4 CEMENT G.L BRICK
1350
12 CEMENT 580
CONCRETE PLASTER IN 230 MASONRY IN
C.M.1:4 CEMENT
2100
MORTAR 1:4
750
FOOT RESET
FOOT RESET
400 CC C.I.
PLASTER IN
400 CC C.I.
C.M.1:4
BRICK BRICK
MASONRY IN MASONRY IN
CEMENT CEMENT
750
750
900 230 1200 230
MORTAR 1:4 MORTAR 1:4
150
150
150
D 580
200 300
1:2:4 CEMENT CONC. WITH
200 300
200 300
20MM STONE AGGREGATE 1:2:4 CEMENT CONC. WITH 1:2:4 CEMENT CONC. WITH
20MM STONE AGGREGATE P.C.C. 1:4:8 WITH 40 MM 20MM STONE AGGREGATE
P.C.C. 1:4:8 WITH 40 MM P.C.C. 1:4:8 WITH 40 MM SIZE BRICK BALLAST P.C.C. 1:4:8 WITH 40 MM
SIZE BRICK BALLAST SIZE BRICK BALLAST SIZE BRICK BALLAST
1900 2200 3200
A B A B A B A B
PLAN
PLAN PLAN
600
900 600
1900 1200
2200 PLAN
600 600
1500 1500
2960 3200
NOTES:-
1. ALL DIMENSIONS ARE IN mm. UNLESS OTHERWISE SPECIFIED.
2. DO NOT SCALE WORK, TO WRITTEN DIMENSIONS ONLY.
0.99
0.25 0.25
H
H
EARTH FILLING EARTH FILLING
1.60
1.60
D D
0.10
GRANULAR BEDDING /
0.15
RCC 1:2:4
PCC 1:4:8
PCC 1:4:8 W
0.10 0.10
W
X - SECTION FOR TYPE.
0.10 0.10 BEDDING
X - SECTION FOR TYPE. NOTES:-
1. ALL DIMENSIONS ARE IN m. UNLESS OTHERWISE SPECIFIED.
2. DO NOT SCALE WORK, TO WRITTEN DIMENSIONS ONLY.
200
RCC 1:2:4
230
230
70 70
PCC 1:4:8
75
SECTION AT A-A'
MANHOLE COVER
PERFORATED
950
810
A A'
810
950
PLAN
TYPE DESIGN :
CHAMBER FOR AIR VALVE
110 120
ROAD LEVEL
100
200
PCC 1:2:4
SPINDLE
SLUICE VALVE
PIPE
500
PCC 1:4:8
100
A A'
500
230
100
PLAN
TYPE DESIGN :
EARTH CUSION
600
8mm@300 C/C
100
SECTION AT A-A'
200
A A'
1000
600
8mm@300 C/C
200
600
1000