You are on page 1of 85

MATERIAL

CATALOGUE
NO. 2
CONTENT

No. Description Pages


1. TERMINATION KIT – G&W 1
2. TERMINATION KIT – RAYCHEM 4
3 TERMINATION KIT – SUDKABEL 11
4. CONTAINER 33KV – CONTAINER 13
MATERIAL
5. CONTAINER 33KV – AIRCOND 52
6. CONTAINER 33KV – LIGHTING 69
MAJOR EQUIPMENT
CATALOGUE LIST

132/11kV Equipment Supplier Submission Remarks


Date
132kV Secondary ETD 24/12/2022 Drawing
Panels with relay Submitted
Dong Feng 07/12/2022 Submitted -Rev
RTU 01
07/12/2022 Submitted -Rev
DC System Nimac/Power Cap 01

Southern / 07/12/2022 Submitted -Rev


132kV Power Cable 01
PCM

Southern / 07/12/2022 Submitted -Rev


11kV Power Cable 01
PCM

Submitted -Rev
Multicore Cables Local Brand 07/12/2022 01
132kV Termination Kits G&W 27/12/2022 Submitted -Rev
02
11kV Termination Kits 3M 07/12/2022 Submitted -Rev
01
RAYCHEM 27/12/2022 Submitted -Rev
02
Earthing Materials Local Brand 07/12/2022 Submitted -Rev
01
Cable Ladder & Local Brand 07/12/2022 Submitted -Rev
Accessories 01
Telecommunication IOB 06/01/2022
33/11kV Equipment Supplier Submission Remarks
Date
33kV Secondary ETD 24/12/2022 Drawing
Panels with relay Submitted
RTU Dong Fang 07/12/2022 Submitted -Rev
01
07/12/2022
DC System Nimac/Power Submitted -Rev
Cap 01

Containerized Building Local 02/12/2022 Drawing


Submitted
Southern/ PCM 07/12/2022 Submitted -Rev
33/11kV Power Cable
01
Multicore Cables Local Brand Submitted -
07/12/2022 Rev 01
33kV Termination Kits 3M 07/12/2022 Submitted -Rev
01

SUDKABLE 27/12/2022 Submitted Rev-


02
11kV Termination Kits 3M 07/12/2022 Submitted -Rev
01

RAYCHEM 27/12/2022 Submitted Rev-


02
Earthing Materials Local Brand 07/12/2022 Submitted -Rev
01

Cable Ladder & Local Brand 07/12/2022 Submitted -Rev


Accessories 01

M&E Lighting 27/12/2022 Submitted


Rev-02
Aircond 27/12/2022 Submitted Rev-02
Structure 27/12/2022 Submitted Rev-02
Material
G&W
RAYCHEM
EPP038911/02 22.10.2002 18:05 Uhr Seite 4

Energy Division
http://energy.tycoelectronics.com

Heat-Shrinkable Termination System


for Cables up to 36 kV

Features:

• Universal termination family for


12-36 kV based on SCTM stress
control technology
• All applications for polymeric and
MIND paper on 1-core, 3-core,
armoured and unarmoured cables
• Red non-tracking HVOT tubing
provides excellent environmental
protection
• Can be used in combination with
RICS / RCAB / RSRB switchgear
connection systems

R
EPP038911/02 22.10.2002 18:05 Uhr Seite 5

The Universal Medium Voltage Termination System for


Polymeric and Paper Insulated Cables

Over the last three decades, engi- Universal Selection Procedure Simplified Installation
neers in utilities and industry around • Simplifield selection table allows • Components are lightweight and
the world have specified of million’s quick selection based on conductor non-shattering
Raychem cable terminations at cross section and voltage class for • Clear instruction sheets
distribution voltages up to 36 kV. either polymeric or MIND paper • Common installation procedure for
Raychem terminations have be- insulated cables (For MI draining oil polymeric and MIND paper cables
come identified with reliability be- cables, contact your local represen- • Factory engineered kit permits rapid
cause of their unparalleled long- tative) on-site installation
term performance – where it really • Simple modification codes permit • No mechanical stress at insulation
counts – in the field. Today there are easy specification of optional screen cutback
many changes influencing the distrib- accessory kits • Termination accommodates same
ution of power at medium voltages. • Enhanced range-taking ability bending radius as cable
For example, the transition to new means that one kit fits more con- • Visual confirmation of correct
types of polymeric cable, distribution ductor sizes, reducing stocking assembly sequence possible after
at higher voltages, and the wide- requirements installation
spread usage of compact switchgear. • Unlimited shelf life allows stocking • Rain skirts can be installed to allow
of economic quantities without either top or bottom feed
Anticipating these industry changes, product spoilage • No soldering of earthing accessories
we have continued to extend and required
improve the product range, based on Simplifield Cable Preparation
the extensive experiece both in the • Improved treatment of screen cut Outstanding Long-Term Reliability
field and at our outdoor test sites in back is compatible with all modern • Fully sealed against water ingress
coastal, polluted and desert environ- screen removal techniques from the environment or from within
ments. Now these developments are • No tapering of insulation required the conductor strands
incorporated in a new generation of • No polishing of polymeric insulation • Polymeric materials load cycle with
Raychem heat-shrinkable cable termi- surface the cable without mechanically
nations, that are even easier to select • No special preparation of sectored, stressing termination components
and install, without compromising or eccentric conductors, or of cable and sealants
the reliability of proven materials that is curved after unreeling from • Unsurpassed performance in
technology. The improved system is the cable drum polluted environments, proven
simpler to use, because the basic ter- • Cable preparation steps are similar over three decades.
mination components and installation to those for Raychem joints
steps are the same – even if your net-
work operates with voltages of 7.2 to
36 kV; if you use 12 kV belted paper
cable and 24 kV water-blocked single
core polymeric cable; whether you
make equipment connections in a
cable box or in compact switchgear.
Let’s review the main advantages of
the improved system:

Raychem Cuxhaven, West Germany,


long-term test site. Raychem termina-
tions have been on test at this North
Sea coast location for over two
decades.
EPP038911/02 22.10.2002 18:05 Uhr Seite 6

Single Core Cable Termination


System

Polymeric Insulated Cable Paper Insulated Cable Polymeric or Paper Insulated


Indoor Service (Mass Impregnated, Non-Draining) Cable Outdoor Service
Indoor Service

void filling compound oil barrier, insulating tubing (clear) rain skirts installed over
installed over paper insulation non-tracking sleeve
stress control tubing
otherwise, installation is the same as otherwise, installation is the same as
non-tracking sleeve with for a polymeric insulated cable for an indoor termination
sealant layer

It`s the same system for all types of


polymeric cable
EPP038911/02 22.10.2002 18:05 Uhr Seite 7

Three-Core Cable Termination Polymeric or Papier Insulated


System Cable Indoor or Outdoor Service

three-core breakout installed at


end of cable oversheath

otherwise, installation steps are


the same as for three single core
terminations

The Raychem termination system


is compatible with all types of
armoured cable.
The system includes a complete
range of solderless accessories for
earthing insulation screens and
cable armour and for grounding
lead sheaths. Also available are
insulators and support brackets,
insulating boots for equipment
connections and glands for easy
entry to cable boxes. Fore more
details please refer to the EPKT
and IXSU Termination Systems
Designer brochure.
EPP038911/02 22.10.2002 18:05 Uhr Seite 2
EPP038911/02 22.10.2002 18:05 Uhr Seite 3

The Tyco Electronics Energy Division All our indoor terminations for poly-
meric or paper insulated cables
can be used with RICS (Raychem
Insulated Connection System).
The RICS, fully insulated, right-angle
and straight adaptors make it easy to
connect any type of cable to modern
compact electrical equipment.
A special RICS, accommodating a
ZnO Surge Arrester is now available
as well as a low profile, one piece
cable termination (IXSU), designed
specifically for applications with very
limited clearances between phases.

We have the universal jointing


system for all types of paper and
polymeric cable up to 36 kV. The
same system allows transition joints
between different tree-core paper
cable and transitions from paper to
polymeric cables. Trifurcations with
any combination of cables are also
easy with the Raychem jointing
system.

For more information about joints


and terminations up to 72 kV and
other problem-solving products, call
your local representative. We have
field sales offices and offer technical
support around the world.

© Tyco Electronics EPP 0389 11/02

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable.
Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular
quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth
in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, BOWTHORPE EMP, CROMPTON INSTRUMENTS, DORMAN SMITH, DULMISON, GURO, HELLSTERN,
LA PRAIRIE, MORLYNN, RAYCHEM, and SIMEL are trademarks.

Energy Division – a pioneer in the development of economical solutions for


the electrical power industry. Our product range includes: Cable accessories,
connectors & fittings, electrical equipment, instruments, lighting, insulators &
insulation enhancement and surge arresters.

For more information and your country contact person, please visit us at:
http://energy.tycoelectronics.com
Tyco Electronics Raychem GmbH, Energy Division
Finsinger Feld 1, 85521 Ottobrunn/Munich, Germany
Phone: +49-89-6089-0, Fax: +49-89-6096345
SUDKABEL
CONTAINER
MATERIAL
TNB RESEARCHSDN. BHD,
OUALITY ASSURANGESERVICES VJrcx/Jsl"^Lseaa
OFPRODUCT
CERTITICATI ACCTPTANC Setial No : D2009-00158

ACEONMA,NUFACTURTNG @) SDN.BHD. ACEONMANUFACTURING(M) SDN.BHD.


Block F, Lot 5181 Block F, Lot 5181
Batu 12, Jalan Balakong Batu 12, Jalan Balakong
43300Sefi Kembangan 43300 Seri Kembangan
Selangor Darul Ehsan Selangor Darul Ehsan

_
SUBSTATION
DOORANDWINDOWPANELFORDISTRIBUTION
GRPCOMPOSITE
S|NGLELEAF(80000093)
& DoUBLE LEAF(80000094)

TNB 2HL.TNB 2FL,TNB 2SD& TNB LW

The above equipment has complied with ihe mandatory rcquirementsof the Technical
Specificationnamed below and is heteby acceptedfor use in the.TNB system by the
Quality Assurance Unit, TNB Researchwho ha3 been appointed by Tenaga Nasional
Berhadas the productquality cettificationand inspectionbody

TNBDTechnicalSpecification- KEJO84o4 i 1999(Approveddate : 23'dDecemberl9gg)


and Amd. No. 1.0(Approveddate : 29u October20031
Specificationfor dhss ReinforcedPlastic(composite)Doorfor DistributionSub"€tation

This certificate shatl ba rcad together with lhe attachment(s),

.la.lr)ti!i.iu..,
is vatiofrom2orhAugust2oo9 io 'lgrhAugust2012
rrris certiticate

Dr. lr. CHEON HOONG


Managing Direitor, TNB ResearchSdn. Bhd.

td ,tutyzooa

ac/lifiarl;ol] ;. srb/era:.) l/,e c.i,itrrii' rrr! ."r,1:ri


This 5 languages
signage not the
latest approved
type (subject to
request if needed)

This Logo no
longer needed in
new latest design

This is latest
approved signage
(only 1 language)

This Logo no
longer needed in
new design
This is latest
approved signage
(only 1 language)
This is not the latest
approved signage
(subjected to
special request if
needed)

This logo no longer


needed in latest
approval

This logo no longer


needed in latest
approval

This is not the latest


approved signage
(subjected to
special request if
needed)

This logo no longer


needed in latest
approval This logo no longer
needed in latest
approval
This logo no longer
needed in latest
approval
Product Benefits
• Fire-Rated (BOMBA) • Fast & Lightweight (IBS)
• Cost Effective • Simple Construction Method
• Space Efficient • Solid, Strong & Secured (BS 5234, Part 2)
• CONQUAS & QLASSIC Standards • High STC & Thermal Resistant
• Better Site Management, Low Wastage • No Stiffeners Required
* Please refer to HCI Technical Department for further design requirement.
1. Set the wall position fix the soffit & floor tracks (U Tracks). 6. Insert mineral wool (optional)
2. Fix the intermediate wall studs (C Stud). 7. Insert 2nd layer of liner board
3. Fix door frame & window frame. 8. Flush jointing & patching of fastener.
4. Install the 1st layer of liner board. 9. Finishes.
5. Fix M&E services.

The wall is complete and ready for painting, texture coating, wallpaper or even tiling application.
Recommended

Recommended

Recommended
Recommended

A118 L9

Recommended
fastener - fastener -
Wing Tek 28mm C1 Wing Tek 32mm C1
Self-embedding head Self-embedding head
wing tek screw, wing tek screw,
#8 x 1 1/8" (28mm) #8 x 1 1/4" (32mm)

Applications: Applications:
7.5mm - 12.0mm 12.0mm- 16.0mm
board thickness board thickness
Jointing Compound PLUS+

Jointing Compound PLUS+

Jointing Compound PLUS+

PRIMA Drywall components calculator


http://www.primafibrecement.com/Resources/Tools
Accessories
fastener - fastener - Jointing Compound PLUS+ Mesh Tape
Wing Tek 22mm C1 Wing Tek 28mm C1
Self-embedding head Self-embedding head Applications: Applications:
wing tek screw, wing tek screw, 28kg/tub. For flush Alkaline resistant
No 8# x 22mm No 8# x 28mm jointing and tape for internal &
patching of holes external application
on Prima fibre
cement board.

Applications: Applications:
4.5mm- 6.0mm board thickness 7.5mm - 12.0mm board thickness

a
100% Asbestos free

For more information, please contact us at:

A CIDB certified -
IBS status company
Singa

on
po

ati
re

Gr CERTIFIED
ific

ee rt
nB Ce
uilding Council

MyHP00175/16

V4 1808
General Building ROCKWOOL® productSHEET
800 356-01/17_V1 (en)

Cool‘n’Comfort ™

Blanket & Slab

General Product Information


ROCKWOOL stone wool products are made of basalt, a volcanic stone.

ROCKWOOL stone wool products are non-combustible with a ROCKWOOL stone wool is inorganic and contains no
melting point more than 1000°C. They are particularly nutritious substance. Therefore it will not be attacked by
suitable for thermal insulation, fire protection and sound microorganisms. Stone wool will not rot and does not attract
reduction or absorption. vermin.

No CFCs, HFCs, HCFCs, or asbestos are used in the


manufacture of ROCKWOOL stone wool products.
Very Good

TÜV SÜD PSB


LIC NO.: 00019G
General Building ROCKWOOL® productSHEET
800 356-01/17_V1 (en)

Cool‘n’Comfort Blanket & Slab ™

Introduction The double skin roofing system is a high performance roofing


system comprising of an aesthetically designed trapezoidal
ROCKWOOL Cool’n’Comfort Series is designed for single or or standing seam profile metal sheet on the top and a metal
double skin metal roof, with or without skylight, to satisfy trapezoidal tray at the bottom. The two metal sheets are fixed
U-value requirements in order to achieve the desired roof together with a z-purlin creating a gap in the roof space for
thermal transmittance value (RTTV). It is also available with a installation of insulation and vapor barrier. When coupled
radiant barrier facing to suit the requirements of all types of with Cool’n’Comfort SL Series stone wool insulation, it boost
roofs in commercial and industrial buildings. Cool’n’Comfort the performance of the double skin metal roofing system
is highly effective in reducing solar heat gain through the roof with improved level of thermal insulation, acoustic and fire
for non air-conditioned buildings; and where air-conditions are protection.
used, Cool’n’Comfort helps to save energy and reduce energy
costs. The unique properties of Cool’n’Comfort contribute to Cool’n’Comfort SL, a semi rigid slab product, is a versatile
making an energy efficient, environmentally sustainable and insulation that is available in various sizes to provide ease of
fire safe roofing system, thereby creating a cool, comfortable installation and a perfect fit between purlins.
and safe indoor environment.
Roofing sheet at Cool'n'Comfort SL g.i. zed spacer spaced at
Applications 0.48mm TCT series at 50mm thick 1200mm centres

Metal roofing systems are generally categorized as single


Roofing sheet at
skin metal roof or double skin metal roof. In single skin roof 0.47mm tct
system, insulation is installed below the metal cladding sheet
held by reinforcing steel wire mesh and aluminum foil rolled
Vapour barrier
over purlins. This roofing system is an economically sound at 1.5mm thick

option for most industrial buildings. Cool’n’Comfort RL Series


is the ideal non-combustible light weight thermal insulation
solution for single skin roofing system.

Cool'n'Comfort RL Metal roofing Vapour barrier


series at 100mm sheet TCT at 1.5mm thick
thick 0.48mm

Aluminium Purlin Reinforcing


foil spaced at steel wire
1200mm mesh
centres

Double Skin Roof System

Single Skin Roof System

Note: All systems drawings are not drawn to scale.


General Building ROCKWOOL® productSHEET
800 356-01/17_V1 (en)

Cool‘n’Comfort Blanket & Slab ™

Water Repellent Facing

Cool’n’Comfort Series is specially formulated with a silicone Cool’n’Comfort Series is available as plain products and
water repellent coated onto each strand of the stone wool additionally with options of foil facing or glass tissue on one-
fibres. *This special coating allows Cool’n’Comfort to repel side or two-sided.
rain water that comes into contact with the product, at the
same time ensuring the product’s excellent thermal and
acoustic performance even after exposure to water.

As Cool’n’Comfort is commonly applied or left outdoor during


Cool‘n’Comfort SL
installation, the silicone water repellent is added into the Series with foil facing
product as a standard offering.

Cool‘n’Comfort RL
Series without facing

Standards

Cool’n’Comfort is designed to meet the requirements of


Malaysian Standard, MS1525 (Code of Practice on Energy
Efficiency and Use of Renewable Energy for Non-Residential
Product Range & Packaging Buildings) and Singapore BCA Green Mark for Residential and
Non-Residential (version 4.0).
Cool’n’Comfort comes in the form of blankets or slabs to suit
many different metal roofing designs and installation needs.

Cool’n’Comfort is shrink-wrapped in polyethylene sheets for


ease of handling, transportation and storage.

Selected range of blanket products are in compressed roll


which gives significant reduction in size compared to folded
blankets, thereby further reducing your warehousing cost.
Please refer to the local sales representatives on the ranges
that are available in compressed roll packaging.

*Note: Water repellent test standard is based on GBT 10299. For more
information, please contact your local representatives.
General Building ROCKWOOL® productSHEET
800 356-01/17_V1 (en)

Cool‘n’Comfort Blanket & Slab ™

Technical Parameters
Product Name Cool'n'Comfort Cool'n'Comfort Cool'n'Comfort Cool'n'Comfort Cool'n'Comfort Cool'n'Comfort Standards
RL920 RL940 SL920 SL940 SL950 SL960

R-value at 50mm 1.39 1.47 1.39 1.47 1.47 1.52


thickness (m2K/W)

Thermal Conductivity 0.036 0.034 0.036 0.034 0.034 0.033 ASTM C518
20°C λ Value (W/mk)

Water Absorption 1.0 1.0 0.5 0.5 0.5 0.5 EN1609.97


(partial immersion
(kg/m2)

Water Vapor Less than Less than Less than Less than Less than Less than ASTM C1104
Absorption 0.04 Vol % 0.04 Vol % 0.04 Vol % 0.04 Vol % 0.04 Vol % 0.04 Vol % C1104M

Fire Performance A1 EN 13501-1


Non Combustibility Non-combustible BS EN 1182
Gross Heat of Not exceeeding 3.2 MJ/kg BS EN ISO 1716
Combustion
(Calorific value)

Melting Point More than 1000oC ASTM E794

Form Factor Blanket Blanket Slab Slab Slab Slab

Thickness 50, 75, 100mm EN 822

Width x Length 1200mm x 5000mm 600mm x 1200mm EN 822

Recommended Single skin metal Single skin metal Double skin Double skin metal Double skin metal Double skin
for these common roof for food centre roof for high metal roof for roof for industrial, roof for exhibition metal roof for
applications or canteen, usually end residential, residential & warehouse & hall, school & concert hall &
non air-condition, to provide a commercial factory where educational airport where
without walls and better thermal buildings for higher insulation institute for high acouctic
highly ventilated performance and general thermal thickness is versatile roof performance
environment. Also long term savings performance designed to design and high on low sound
commonly used on energy bill be slightly durability frequencies are
in walkways and compressed for required
common pavilion acoustic damping
in residential of the metal roof
estates

Sound absorption coefficient at octave band (50mm thickness)


Product 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC αw

Cool'n'Comfort RL920 0.20 0.60 1.00 1.00 1.00 1.00 1.00 0.90

Cool'n'Comfort RL940 0.20 0.70 1.00 1.00 1.00 1.00 1.05 1.00

Cool'n'Comfort SL920 0.20 0.60 1.00 1.00 1.00 1.00 1.00 0.90

Cool'n'Comfort SL940 0.20 0.70 1.00 1.00 1.00 1.00 1.05 1.00

Cool'n'Comfort SL950 0.20 0.75 1.00 1.00 1.00 1.00 1.05 1.00

Cool'n'Comfort SL960 0.30 0.85 1.00 1.00 1.00 1.00 1.05 1.00

www.rockwoolasia.com

Rockwool Malaysia Rockwool Malaysia Rockwool (Thailand) Limited Disclaimer: The information contained in this
Sdn Bhd Sdn Bhd Hemaraj Eastern Industrial data sheet is believed to be correct at the date
Lot 4, Solok Waja 1 175 A&B Estate (Map Ta Phut) of publication. ROCKWOOL does not accept
Bukit Raja Industrial Estate Kawasan Perindustrian 1 Soi G 2, Pakornsongkrohraj responsibility for the consequences of using
41050 Klang, Selangor Air Keroh, Jalan Lingkungan Road, Huaypong, Muang Cool‘n’Comfort™ Blanket & Slab in applications
Malaysia Usaha, 75450 Melaka Rayong 21150 different from those described above.
T (+60) 3 3341 3444 Malaysia Thailand
F (+60) 3 3342 7290 T (+60) 6 233 2010 T (+66) 3868 5110
F (+60) 6 233 2012 F (+66) 3868 4938
AIRCOND
LIGHTING
Self-Contained Emergency KELUAR Sign
PEX-215LED (Super Bright LEDs)

Specifications
Model ........................... PEX-215 LED.
Light Source ................... 18 nos super bright LED (SMD).
LED Wattage .................. ~0.80W.
Mode ........................... Maintained.
Weight ........................... ~1.2 Kg.
Battery ........................... 2 x 1.2V 1.7AH Ni-Cd.
Housing .......................... Electro-galvanised sheet steel with powder coated paint.
Charger .......................... Constant current.
Mounting ........................ Surface mounting direct to wall or ceiling.
Dimension ....................... 556mm (L) x 52mm (W) x 155mm (H).
Monitoring ...................... Red LED indicating healthy supply and charging.
Compliance ...................... MS 983 : 2004, MS 619-2-22:2005.
MS IEC 60598-1 : 2012.

Input Voltage .................... 240 V +/- 10% 50Hz.


Recharge Period ................ 16 - 24 hours.
Back Up Duration .............. 3 hours.
Battery Protection ............. Low voltage cut-off to prevent over discharging.
Input Power .................... 4.5W.
Ingress Of Protection .......... IP-20.
Ambient Temperature ........ 0
40 C.

Note : Due to continuous development and improvement, our company reserves the right to change specifications without notice.
PEX 215 LED
PNE EMERGENCY ‘KELUAR’ SIGN
TM

SIDE COVER (L)

DETAIL A

INCOMING WIRE
STEP 1
WALL
MAIN CASING

STEP 1
DETAIL 'A'
NEUTRAL
N

EARTH
PANEL
LIVE
SIDE COVER (R)
L

INSTALLATION OF MODEL PEX 215 LED STEP 2