You are on page 1of 2
Zamily 22) Glee de Jie 4% veneer ZAMIL OFFSHORE SERVICES COMPANY OFFSHORE HOOK UP, UPGRADE MODIFICATION, SCADA INSTALLATION AND COMISSIONING SUPPORT (CONTRACT : 6600044802) TOOL BOX TALK Location: QMS OMAR Date: $1-AUGUST-2021 Start Time:06:30 AM ‘TBT Log No :TBQM-OMAR-COAT-050 Meeting Duration:30 Minutes Number of Attendees: 6 Topics Discussed: * ABRASIVE BLASTING SAFETY. * Saudi Aramco reference standard SAES-H-004 Para 5.4.2 © PARTICIPANTS ° Sl] Zamil Emp. [Aramco 1D 7 —[ Name oF Avendee | Position ] Siaeure—] No | # TQAMA 1 | eae 3343026 | asoul eam Mech, FOREMAN 2 | suecon | 47053 | ansnaoveranim | arrucaTon A ce somos | ssneeie | nooetvauncsi | aPrucarowvaasien fee nz: | SUB-CON 366266 | ATIQURRAHMAN | BLASTER ) Ae 3 [632.07 | 24s ase encap moxeadl appiete/glyhes| [C7 QC Inspector QC Supervisor Name: SARMAD AEE Name FRANCIS BINUYA Discipline COATING 0 Discipline ‘TBT Log No: TBQM-OMAR-COAT-050 Page 1 e ABRASIVE BLASTING SAFETY. . Blasting nozzle shall be equipped with a remote control shut-off switch, known as “Dead man”. 2. The blast nozzle shall be electrically connected to an external ground in order to prevent static electrical discharges_or_ shocks. to- operating- personnel.-Grounding wire shall be AWG-4 or larger.. 3. The blasting hose shall be the static dissipating type with external couplings. 4. Respirable air-fed abrasive blasting hoods and OSHA- approved in-line respirable air filters shall be utilized at all times by abrasive blasting personnel. w . Compressor hoses, air lines, and blast hoses shall be safety locked at each coupling using proper safety pins. 6. Hearing protection shall be worn in confined spaces where abrasive blasting is in progress. TBT Log No: TBQM-OMAR-COAT-050 Page 2

You might also like