SSR 2022-23 :- Pile Foundation: Building


755 Pile Foundation: 22.01 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-20 RCCsingle rim As directed by One Running 810 180
Building bored pile of 225 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except rock,
excluding provision of reinforcement including placing with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade) by tremie arrangement, compaction of concrete including chipping and dressing
including chipping and dressing if required etc. complete. (Excluding steel reinforcement)

756 Pile Foundation: 22.02 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete of M2O grade RCC As directed by One Running 1041 273
Building single rim bored pile of 300 mm dia. each of load capacity as per design and of specified Engineer in charge Metre
diameter of pile and bulb as directed, sunk to the required depth through all strata except
rock, excluding provision of reinforcement including placing with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch
mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangement compaction of concrete including chipping and dressing etc.
complete. (Excluding steel reinforcement)

757 Pile Foundation: 22.03 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-20 for single rim As directed by One Running 1355 394
Building bored pile of 380 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except rock,
excluding provision of reinforcement including placing with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade) by tremie arrangement compaction of concrete including chipping and dressing
etc. complete. (Excluding steel reinforcement)

758 Pile Foundation: 22.04 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-20 for single rim As directed by One Running 1713 549
Building bored pile of 450 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except rock,
excluding provision of reinforcement including placing with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade) by tremie arrangement compaction of concrete including chipping and dressing
etc. complete. (Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

759 Pile Foundation: 22.05 Bd-B Providing and laying M-20 RCC cast in situ single rim bored pile of 535 mm dia. each of As directed by One Running 2175 711
Building load capacity as per design and of specified diameter of pile and bulb as directed, Engineer in charge Metre
sunk to the required depth through all strata except rock, excluding provision of
reinforcement including placing with fully automatic micro processor based PLC
with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan
mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by tremie
arrangement compaction of concrete including chipping and dressing etc. complete.
(Excluding steel reinforcement)

760 Pile Foundation: 22.06 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-20 for single rim As directed by One Running 2598 873
Building bored pile of 600 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except rock,
excluding provision of reinforcement including placing with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade) by tremie arrangement compaction of concrete including chipping and dressing
etc. complete. (Excluding steel reinforcement)

761 Pile Foundation: 22.07 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for single rim As directed by One Running 817 180
Building bored pile of 225 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except rock,
excluding provision of reinforcement including placing with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade) by tremie arrangement compaction of concrete including chipping and dressing
etc. complete. (Excluding steel reinforcement)

762 Pile Foundation: 22.08 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for single rim As directed by One Running 1069 273
Building bored pile of 300 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except
rock,excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade) by tremie arrangement compaction of concrete including chipping and
dressing etc. complete. (Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

763 Pile Foundation: 22.09 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for single rim As directed by One Running 1376 394
Building bored pile of 380 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except
rock,excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade) by tremie arrangement compaction of concrete including chipping and
dressing etc. complete. (Excluding steel reinforcement)

764 Pile Foundation: 22.10 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for single rim As directed by One Running 1841 549
Building bored pile of 450 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except
rock,excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade) by tremie arrangement compaction of concrete including chipping and
dressing etc. complete. (Excluding steel reinforcement)

765 Pile Foundation: 22.11 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-20 for double rim As directed by One Running 923 180
Building bored pile of 225 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except
rock,excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade) by tremie arrangement compaction of concrete including chipping and
dressing etc. complete. (Excluding steel reinforcement)

766 Pile Foundation: 22.12 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-20 for double rim As directed by One Running 1335 273
Building bored pile of 300 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except
rock,excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade) by tremie arrangement compaction of concrete including chipping and
dressing etc. complete. (Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

767 Pile Foundation: 22.13 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-20 for double rim As directed by One Running 1961 394
Building bored pile of 380 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except
rock,excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade) by tremie arrangement compaction of concrete including chipping and
dressing etc. complete. (Excluding steel reinforcement)

768 Pile Foundation: 22.14 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-20 for double rim As directed by One Running 2728 549
Building bored pile of 450 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except
rock,excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade) by tremie arrangement compaction of concrete including chipping and
dressing etc. complete. (Excluding steel reinforcement)

769 Pile Foundation: 22.15 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for double rim As directed by One Running 962 180
Building bored pile of 225 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except
rock,excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade) by concrete prepared in reversible drum type concrete mixer by tremie
arrangement, compaction of concrete including chipping and dressing etc. complete.
(Excluding steel reinforcement)

770 Pile Foundation: 22.16 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for double rim As directed by One Running 1416 273
Building bored pile of 300 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except rock,
excluding provision of reinforcement including placing with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade) by concrete prepared in reversible drum type concrete mixer by tremie
arrangement, compaction of concrete including chipping and dressing etc. complete.
(Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

771 Pile Foundation: 22.17 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for double rim As directed by One Running 2109 394
Building bored pile of 380 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except rock,
excluding provision of reinforcement including placing with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade) by concrete prepared in reversible drum type concrete mixer by tremie
arrangement, compaction of concrete including chipping and dressing etc. complete.
(Excluding steel reinforcement)

772 Pile Foundation: 22.18 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for double rim As directed by One Running 2955 549
Building bored pile of 450 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except rock,
excluding provision of reinforcement including placing with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade) by concrete prepared in reversible drum type concrete mixer by tremie
arrangement, compaction of concrete including chipping and dressing etc. complete.
concrete prepared in reversible drum type concrete mixer by tremie arrangement,
compaction of concrete including chipping and dressing etc. complete. (Excluding steel
reinforcement)

773 Pile Foundation: 22.19 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for double rim As directed by One Running 4237 711
Building bored pile of 535 mm dia. each of load capacity as per design and of specified diameter of Engineer in charge Metre
pile and bulb as directed, sunk to the required depth through all strata except
rock,excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade) by concrete prepared in reversible drum type concrete mixer by tremie
arrangement, compaction of concrete including chipping and dressing etc. complete.
(Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

774 Pile Foundation: 22.20 Bd-B Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for in situ double As directed by One Running 5487 873
Building rim bored pile of 600 mm dia. each of load capacity as per design and of specified Engineer in charge Metre
diameter of pile and bulb as directed, sunk to the required depth through all strata
except rock, excluding provision of reinforcement including placing with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
by concrete prepared in reversible drum type concrete mixer by tremie arrangement,
compaction of concrete including chipping and dressing etc. complete.concrete prepared
in reversible drum type concrete mixer by tremie arrangement, compaction of concrete
including chipping and dressing etc. complete. (Excluding steel reinforcement)

775 Pile Foundation: 22.21 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles each As directed by One Running 2659 1352
Building of load capacity and as per design and of 325 mm diameter or as directed placed through Engineer in charge Metre
steel shells sunk to the required depth through all strata except rock excluding
provision of reinforcement as per detailed drawings and design approved by the
Engineer-in- charge including placing with fully automatic micro processor based
PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan
mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by concrete
prepared by tremie arrangement, compaction of concrete including chipping and
dressing etc. complete. concrete by tremie arrangements, compaction of concrete
including chipping and dressing and withdrawal of shell etc. complete. (Excluding
steel reinforcement)

776 Pile Foundation: 22.22 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 2771 1379
Building each of load capacity and as per design and of 350mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremiearrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

777 Pile Foundation: 22.23 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 3002 1435
Building each of load capacity and as per design and of 400 mm diameter.or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge including placing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

778 Pile Foundation: 22.24 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 3129 1467
Building each of load capacity and as per design and of 425mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge including placing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

779 Pile Foundation: 22.25 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 3450 1537
Building each of load capacity and as per design and of 475mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge including placing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

780 Pile Foundation: 22.26 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 3941 1772
Building each of load capacity and as per design and of 500mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge including placing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

781 Pile Foundation: 22.27 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 4212 1811
Building each of load capacity and as per design and of 525 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge including placing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

782 Pile Foundation: 22.28 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 4379 1852
Building each of load capacity and as per design and of 550 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge including placing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

783 Pile Foundation: 22.29 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 4738 1940
Building each of load capacity and as per design and of 600 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge including placing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

784 Pile Foundation: 22.30 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 5149 1987
Building each of load capacity and as per design and of 625 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

785 Pile Foundation: 22.31 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 5348 2035
Building each of load capacity and as per design and of 650 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

786 Pile Foundation: 22.32 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 6337 2250
Building each of load capacity and as per design and of 750 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

787 Pile Foundation: 22.33 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 6822 2368
Building each of load capacity and as per design and of 800 mm diameter. or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

788 Pile Foundation: 22.34 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 7642 2709
Building each of load capacity and as per design and of 825 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

789 Pile Foundation: 22.35 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 8455 2908
Building each of load capacity and as per design and of 900 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

790 Pile Foundation: 22.36 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 9331 3122
Building each of load capacity and as per design and of 975 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

791 Pile Foundation: 22.37 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 9641 3198
Building each of load capacity and as per design and of 1000 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

792 Pile Foundation: 22.38 Bd/B-4 P-270 Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles As directed by One Running 10279 5039
Building each of load capacity and as per design and of 1050 mm diameter or as directed placed Engineer in charge Metre
through steel shells sunk to the required depth through all strata except rock
excluding provision of reinforcement as per detailed drawings and design approved
by the Engineer-in- charge includingplacing with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by
tremie arrangements, compaction of concrete including chipping and dressing and
withdrawal of shell etc. complete. (Excluding steel reinforcement)

793 Pile Foundation: 22.39 Bd/B-2 P-269 Chiseling through pile shells in hard strata like boulders, soft and hard rocks Upto As directed by Rig Hour 911 911
Building and inclusive of 550 mm diameter including removing and stacking the loose Engineer in charge
materials etc. complete and disposing of the unserviceable materials outside complete.

794 Pile Foundation: 22.40 Bd/B-2 P-269 Chiseling through pile shells in hard strata like boulders, soft and hard rocks Beyond 550 As directed by Rig Hour 1434 1434
Building mm and upto and inclusive of 750 mm dia. including removing and stacking the loose Engineer in charge
materials etc. complete and disposing of the unserviceable materials outside complete.

795 Pile Foundation: 22.41 Bd/B-2 P-269 Chiseling through pile shells in hard strata like boulders, soft and hard rocks Beyond 750 As directed by Rig Hour 1659 1659
Building mm and upto and inclusive of 900 mm dia including removing and stacking the loose Engineer in charge
materials etc. complete and disposing of the unserviceable materials outside complete.

796 Pile Foundation: 22.42 Bd/B-2 P-269 Chiseling through pile shells in hard strata like boulders, soft and hard rocks Beyond 900 As directed by Rig Hour 2399 2399
Building mm and upto and inclusive of 1050 mm dia. including removing and stacking the loose Engineer in charge
materials etc. complete and disposing of the unserviceable materials outside complete.

797 Pile Foundation: 22.43 Bd/B-8 P-271 Carrying out load test for 1.5 times the proposed safe working load on the pile in As directed by One Number 105513 80469
Building driven position upto 400 mm diameter including construction of test cap, use of Engineer in charge
accessories and instruments including providing graphs as per I.S. code or
Std.Specifications and dismantling the test cap after testing and cleaning the site complete.

798 Pile Foundation: 22.44 Bd/B-8 P-271 Carrying out load test for 1.5 times the proposed safe working load on the pile in As directed by One Number 127987 102942
Building driven position above 400 mm and upto to 550 mm diameter including construction of Engineer in charge
test cap, use of accessories and instruments including providing graphs as per
I.S. code or Std.Specifications and dismantling the test cap after testing and cleaning
the site complete.
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

799 Pile Foundation: 22.45 Bd/B-8 P-271 Carrying out load test for 1.5 times the proposed safe working load on the pile in As directed by One Number 176736 151692
Building driven position above 550 mm and upto 650 mm diameter including construction of test Engineer in charge
cap, use of accessories and instruments including providing graphs as per I.S. code or
Std.Specifications and dismantling the test cap after testing and cleaning the site complete.

800 Pile Foundation: 22.46 Bd/B-8 P-271 Carrying out load test for 1.5 times the proposed safe working load on the pile in As directed by One Number 222412 197368
Building driven position above 650 mm and upto 750 mm diameter including construction of test Engineer in charge
cap, use of accessories and instruments including providing graphs as per I.S. code or
Std.Specifications and dismantling the test cap after testing and cleaning the site complete.

801 Pile Foundation: 22.47 Bd/B-8 P-271 Carrying out load test for 1.5 times the proposed safe working load on the pile in As directed by One Number 268147 243103
Building driven position above 750 mm and upto 825 mm diameter including construction of test Engineer in charge
cap, use of accessories and instruments including providing graphs as per I.S. code or
Std.Specifications and dismantling the test cap after testing and cleaning the site complete.

802 Pile Foundation: 22.48 Bd/B-8 P-271 Carrying out load test for 1.5 times the proposed safe working load on the pile in As directed by One Number 311479 286435
Building driven position above 825 mm and upto 900 mm diameter including construction of test Engineer in charge
cap, use of accessories and instruments including providing graphs as per I.S. code or
Std.Specifications and dismantling the test cap after testing and cleaning the site complete.

803 Pile Foundation: 22.49 Bd/B-8 P-271 Carrying out load test for 1.5 times the proposed safe working load on the pile in As directed by One Number 388752 363707
Building driven position above 900 mm diameter including construction of test cap, use of Engineer in charge
accessories and instruments including providing graphs as per I.S. code or
Std.Specifications and dismantling the test cap after testing and cleaning the site complete.

804 Pile Foundation: 22.50 Empty boring for 325 to 400 mm dia bored R.C.C. cast in situ piles including withdrawal As directed by One Running 579 422
Building of shell, removal of earth to a distance of 50 metres etc. complete. Engineer in charge Metre
Spec :(As directed by Engineer in Charge)
805 Pile Foundation: 22.51 Empty boring for 425 to 500 mm dia. bored R.C.C. cast in situ piles including withdrawal As directed by One Running 668 504
Building of shell, removal of earth to a distance of 50 metres etc. complete. Engineer in charge Metre
Spec :(As directed by Engineer in Charge)
806 Pile Foundation: 22.52 Empty boring for 525 to 600 mm dia. bored R.C.C. cast in situ piles including withdrawal As directed by One Running 1348 1166
Building of shell, removal of earth to a distance of 50 metres etc. complete. Engineer in charge Metre
Spec :(As directed by Engineer in Charge)
807 Pile Foundation: 22.53 Empty boring for 625 to 700 mm dia. bored R.C.C. cast in situ piles including withdrawal As directed by One Running 1384 1166
Building of shell, removal of earth to a distance of 50 metres etc. complete. Engineer in charge Metre
Spec :(As directed by Engineer in Charge)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

808 Pile Foundation: 22.54 Empty boring for 725 to 1050 mm dia. bored R.C.C. cast in situ piles including As directed by One Running 1485 1249
Building withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Engineer in charge Metre
Spec :(As directed by Engineer in Charge)
809 Pile Foundation: 22.55 Chipping and dressing of the R.C.C. piles upto 0.60 meterincluding cleaning As directed by One Number 744 744
Building reinforcement and removal of dismantled materials upto a distance of 50 meter beyond the Engineer in charge
building area etc. for providing pile caps.
Spec :(As directed by Engineer in Charge
810 Pile 22.56 Providing bentonite slurry process for various diameter of piles vide Item Nos 1 (i to xxiv) As directed by One Running 80 30
Foundation: above. Spec : (As directed by Engineer in Charge) Engineer in charge Metre
Building
811 Pile Foundation: 22.57 Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C. Piles As directed by Metric Tonne 100890 21389
Building upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom Engineer in charge
including fabricating cutting the mild steel sheet to required diameter and shape ,welding
the joints and driving with the help of required machineries including all materials
labours and lifts etc. complete as directed by the Engineer in charge. Upto 3.00 meter
deep liner
812 Pile Foundation: 22.58 Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C. Piles As directed by Metric Tonne 104801 25299
Building upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom Engineer in charge
including fabricating cutting the mild steel sheet to required diameter and shape ,welding
the joints and driving with the help of required machineries including all materials
labours and lifts etc. complete as directed by the Engineer in charge. Spec :(As directed
by Engineer in Charge From 3.00 to 9.50 meter deep liner

813 Pile Foundation: 22.59 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap metal for As directed by One Cubic Metre 7534 2165
Building R.C.C. pile caps as per detailed designs and drawings, including bailing out water Engineer in charge
manually, centering, formwork, laying/ pumping, compacting, finishing and curing
etc. with fully automatic micro processor based PLC with SCADA enabled
reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete.with Crushed sand VSI Grade/V.S.I. quality Artificial Sand, complete.
(Excluding steel reinforcement)
814 Pile Foundation: 22.60 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for As directed by One Cubic Metre 7505 2165
Building R.C.C. pile caps as per detailed designs and drawings, including bailing out water Engineer in charge
manually, centering, formwork, laying/ pumping, compacting, finishing and curing
etc. with fully automatic micro processor based PLC with SCADA enabled
reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete.with Crushed sand VSI Grade/V.S.I. quality Artificial Sand, complete.
(Excluding steel reinforcement)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

815 Pile Foundation: 22.61 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap metal for As directed by One Cubic Metre 7695 2165
Building R.C.C. pile caps as per detailed designs and drawings, including bailing out water Engineer in charge
manually, centering, formwork, laying/ pumping, compacting, finishing and curing
etc. with fully automatic micro processor based PLC with SCADA enabled
reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With
fine aggregate (Crushed sand VSI Grade) complete (Excluding steel reinforcement)

You might also like