You are on page 1of 6

STT Câu hỏi Đáp án

1 The preferred method of battery charging a Ni-Cad battery is constant. (Level 1) 2


2 What would you use to neutralise nicad battery spillage?. (Level 1) 1
3 Wires in hot temperature areas should be bound with. (Level 1) 1
4 A heat gun should be operated at. (Level 1) 3
5 Speed of an HMG is controlled by a. (Level 1) 2
6 When the temperature increases in a lead acid battery, the SG will. (Level 1) 1
7 Control of hydraulically powered emergency electrical generator frequency is. (Level 1) 2
8 Electrical load on aircraft is controlled by. (Level 1) 1
9 Topping up a Ni-Cad battery in situ. (Level 1) 1
10 Circulating currents are associated with. (Level 1) 2
11 What is the amperage at point '' to the nearest amp?. (Level 1) 2
12 What does the differential sensing coil sense?. (Level 1) 3
13 Pitot tubes are heated by. (Level 1) 3
14 Paralleling is used for. (Level 1) 1
15 Battery charging procedures can be found in ATA. (Level 1) 2
16 Maximum battery temperature on charging before protection circuit starts is. (Level 1) 2
17 If an aircraft has no battery charger, the battery is charge (Level 1) 3
18 The output of a carbon pile regulator with no variation of loading is. (Level 1) 1
19 A paralleled relay for a DC system is energised and connected (Level 1) 3
20 When resetting the CSD on the ground, the engine should be. (Level 1) 3
21 How is RAT driven?. (Level 1) 1
22 How is an aircraft battery rated?. (Level 1) 1
23 Where does the GCU gets its power?. (Level 1) 3
24 Eddy currents are. (Level 1) 1
25 The small pins in the power connector plug are. (Level 1) 3
26 Zener diodes are for. (Level 1) 2
27 AC generator output indications are measured in. (Level 1) 1
28 Load shedding allows. (Level 1) 1
29 In what units are static inverters rated?. (Level 1) 1
30 On engine shutdown, what prevents GCR being tripped?. (Level 1) 2
31 When loads are shed from a busbar automatically. (Level 1) 1
32 What controls output from the generator?. (Level 1) 2
33 Specific Gravity in a lead acid battery should give an indication of. (Level 1) 1
34 Excessive commutator sparking can be caused by. (Level 1) 3
35 A neutralising agent for sulphuric acid is. (Level 1) 3
36 Flashing a generator field. (Level 1) 2
37 The purpose of an inverter is to convert. (Level 1) 1
38 The electrolyte in a lead-acid battery contains. (Level 1) 2
39 Frequency (Hz) is the number of cycles per. (Level 1) 2
40 The three voltages of a three phase generator are. (Level 1) 2
41 A 12 volt lead-acid battery. (Level 1) 2
42 The active component of an A.C. circuit is 4 amps and the reactive is 3 amps. Ammeter reading w 3
43 Which aircraft circuit would be most likely to use frequency wild 200V AC?. (Level 1) 3
44 The output of a DC generator is controlled by varying the. (Level 1) 3
45 On an AC external power plug, the interlock circuit is controlled by pins. (Level 1) 3
46 A generator rated at 30 kVA power factor 0.8 has a maximum continuous power output of. (Lev 3
47 For battery charging, the electrical supply connected to the battery must be. (Level 1) 3
48 The output from an AC generator is taken from. (Level 1) 3
49 The purpose of an inverter is to convert. (Level 1) 1
50 Battery SG is measured using a. (Level 1) 3
51 A battery for use on aircraft must have a capacity of. (Level 1) 1
52 When connecting aircraft batteries, the last lead to connect is the. (Level 1) 1
53 In a paralleled AC generation system load sharing is for. (Level 1) 3
54 A frequency wild supply would be suitable for. (Level 1) 2
55 Three 12V, 40Ah accumulators in series would give. (Level 1) 3
56 Voltage is controlled by. (Level 1) 2
57 Three 12V, 40Ah accumulators in parallel would give. (Level 1) 2
58 An inverter can be an AC generator driven by. (Level 1) 3
59 When mixing electrolyte for lead acid batteries. (Level 1) 2
60 The RPM of a 6 pole, 400 Hz alternator is. (Level 1) 2
61 The ground interlock pins are numbered. (Level 1) 3
62 Distilled water should be added to a ni-cad battery. (Level 1) 1
63 During a normal engine shutdown, generator tripping is initiated by. (Level 1) 1
Đáp án 1
voltage.
Boric acid.
Teflon.
100°C above the specified.
CSD unit.
decrease.
by CSU.
a BPCU.
is not allowed.
AC and DC generators in parallel.
100 Amps.
Power.
DC.
AC and DC electrical generators.
Chapter 24 Section 21.
144 degrees C.
constant current until a predetermined limit when it auto
stationary.
zeners and transistors.
rotating at Nsync.
Airstream.
Ampere hours.
RAT.
circulating currents.
negative.
voltage stabilisation.
KVA & KW.
less current to the busbar.
kVA.
Under-volt.
bus bar current decreases.
BPCU.
charge.
rotating field diode failure.
borax powder.
decreases resistance.
DC to AC.
nitric acid.
revolution.
90 degrees apart.
has 24 cells.
3.4 amps.
Hydraulic pump.
armature current.
AB.
37.5 kW.
AC at 50 c.p.s.
slip rings.
DC to AC.
hygrometer.
0.8.
negative.
reactive load only.
instruments and navigation systems.
36V 120Ah.
the constant speed drive.
12V 40Ah.
an AC motor.
the method of mixing is unimportant.
6000.
A and B.
only in the battery workshop.
undervoltage.
Đáp án 2 Đáp án 3
current. power.
Distilled water. Bicarbonate of soda.
Nomex. PVC.
100°C below the specified. the specified temperature.
swashplate. ID unit.
increase. remain the same.
by angle of swash plate. by IDG.
an IRS. a GCU.
is only allowed in the shop. is permitted.
AC generators in parallel. DC generators in parallel.
101 Amps. 102 Amps.
Volts. Current.
AC. AC or DC.
DC electrical generators only. AC electrical generators only.
Chapter 24 Section 31. Chapter 31 Section 21.
144 degrees F. 71 degrees F.
constant current. constant voltage.
pulse width modulating. fluctuating.
current coil. voltage and current coil.
rotating at idle. stationary.
Compressor. Fan.
Joules. Watts.
Battery. PMG.
caused by heating effect of the coil. caused by resistance of the coil.
neutral. positive.
voltage regulation. rectification.
KW & KVAR. KW.
more current to the busbar. more voltage to the busbar.
kVAR. kW.
Under-frequency. Under-current.
bus bar current rises. bus bar voltage rises.
GCU. ELCU.
electrolyte temperature. electrolyte level.
brushes positioned on MNA. weak spring tension.
citric acid. sodium bicarbonate.
restores magnetism. increases resistance.
AC to DC. AC to a higher frequency AC.
sulphuric acid. hydrochloric acid.
second. minute.
120 degrees apart. 180 degrees apart.
has 6 cells. has 12 cells.
7 amps. 5 amps.
Standby compass. Windscreen heating.
engine speed. field current.
CD. EF.
30 kW. 24 kW.
AC at 400 c.p.s. DC.
slip rings via commutator. connections on the stator.
AC to a higher frequency AC. AC to DC.
hypsometer. hydrometer.
0.5. 0.9.
positive earth. positive.
real load only. real and reactive load.
deicing loads. 3-phase torque motors.
12V 120Ah. 36V 40Ah.
the voltage regulator. the swashplate.
12V 120Ah. 36V 120Ah.
either an AC or DC motor. a DC motor.
add acid to water. add water to acid.
8000. 4000.
C and N. E and F.
at any time. when fully charged.
underfrequency. overcurrent.