You are on page 1of 4

Totally Integrated

Automation Portal

gracetbaitapPLC_V15.1 / PLC_1 [CPU 1214C DC/DC/DC] / Program blocks


Main [OB1]
Main Properties
General
Name Main Number 1 Type OB Language LAD
Numbering Automatic
Information
Title "Main Program Sweep (Cy‐ Author Comment Family
cle)"
Version 0.1 User-defined ID

Main
Name Data type Default value Comment
Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant

Network 1:

%M0.0
%M20.1 "trang_thai_
"Stop" ban_dau"
RESET_BF
200

%Q0.0
"A+"
RESET_BF
10
Totally Integrated
Automation Portal

Network 2:

%M0.0
%Q0.0 %Q0.1 %Q0.2 %Q0.3 %Q0.0 "trang_thai_
"A+" "A-" "B+" "B-" "A+" ban_dau"

%M0.0
"trang_thai_
ban_dau"

Network 3:

%M0.0
"trang_thai_ %M20.0 %M10.0 %M10.2 %Q0.2 %Q0.0
ban_dau" "Start" "a0" "b0" "B+" "A+"

%Q0.1 %M10.0 %M10.2


"A-" "a0" "b0"

%Q0.0
"A+"

Network 4:
Totally Integrated
Automation Portal

%Q0.0 %M10.1 %M10.2 %Q0.3 %Q0.2


"A+" "a1" "b0" "B-" "B+"

%Q0.2
"B+"

Network 5:

%Q0.2 %M10.1 %M10.3 %Q0.1 %Q0.3


"B+" "a1" "b1" "A-" "B-"

%Q0.3
"B-"

Network 6:

%Q0.3 %M10.1 %M10.2 %Q0.0 %Q0.1


"B-" "a1" "b0" "A+" "A-"

%Q0.1
"A-"

Network 7:
Totally Integrated
Automation Portal

%FC1
"Mo phong HMI"
EN ENO