5.5.22. Emergency procedures.

5.5.22.1. The emergency stop switch can be actuated for an immediate shutdown of the
power unit. The emergency hydraulic pump will automatically actuate for 30 seconds to
provide power steering, service brakes, and parking brake.

5.5.22.1.1. Ensure the transmission is placed back to neutral.

5.5.22.2. The emergency pump can be used to operate all deck functions.

5.5.22.2.1. Turn the ignition and parking brake to the ON position.

5.5.22.2.2. Actuate and hold the EMERGENCY PUMP switch to the ON position.

5.5.22.2.3. Engage deck functions as normal.

5.5.22.2.4. When using the emergency pump to raise the deck, the deck supply cutoff
valve must be in the off (down) position.

5.5.22.3. Towing procedures (from rear).

5.5.22.3.1. Connect the tow vehicle to the rear tow points on the chassis.

5.5.22.3.2. Turn ignition switch to the ON position.

5.5.22.3.3. Release parking brake while holding Emergency Pump switch on.

5.5.22.3.4. Slowly tow loader away from the aircraft. Note: Maximum towing
distance is 500 feet.

5.5.22.3.5. Towing more than 500 ft. requires the drive shaft to be disconnected.

5.5.22.4. Lifting and towing loader.

5.5.22.4.1. Lift the loader from the front by attaching to the tow points on the chassis.

5.5.22.4.2. Protection from the damage may be required for front of loader.