You are on page 1of 11

Register tools

6-1
AP100G CAM Operation Guide I NCT
6.1 Change Turret Load
[Tooling]-[Turret Load] 6
AP100G CAM Operation Guide I NCT

Change turret load. Change


There are five functions for setting up turret. Turret Load
! Add/Replace tools in the turret without having tools in inventory.
! Remove tools from a turret
! Move a tool within the turret
! Register the turret load.
! Auto tool load to the turret.

Add/Replace tools without having it in inventory.

Add/Replace tools to the turret without having tools in inventory. It


allows you to add/replace tools without going to Punch Master manager.

Caution # You cannot change any tools that are already used.

1. Click [Turret] and [Turret Load].


Operation ⇒ Refer [Setting items in “Turret Load”])
(⇒

2. Select the tool or an empty station in [Turret] in the [Turret


Load] dialog box to change.

● When you select a tool, it is replaced with a tool you specify below.
Tips

3. Click [Setup]. Or, double-click the station you selected in step 2.


⇒ Refer [Setting items in “Turret Load”])
(⇒

4. Specify the settings in the [Change Tool Information] dialog box,


and then click [OK].

6-2
Remove a tool from a turret
Remove a tool from a turret
Caution
# You cannot remove any tools that are already used (displayed in 6
AP100G CAM Operation Guide I NCT

red).
Change
Operation 1. Click [Tooling] and [Tooling Layout]. Turret Load
⇒ Refer [Setting items in “Turret Load”])
(⇒

2. Select the tool to remove in [Turret] in the [Turret Load] dialog


box.
3. Click [Delete].
4. Confirm the message, and then click [OK].

5. Click [Close].

Move tools within the turret

Move a tool from station to another station

Operation 1. Click [Turret] and [Turret Load].


⇒ Refer [Setting items in “Turret Load”])
(⇒

2. Select the tool in [Turret] in the [Turret Load] dialog box to


move.
3. Click [Move].

6-3
4. Select the station to move tool to.
Caution ● You cannot move a tool to a place with a different key spec.

6
● The tool that is selected to move tool to will automatically be moved to
AP100G CAM Operation Guide I NCT

[Outside Turret]. Change


Tips ● Different station size can be specified to support adaputer of the tool.
Turret Load
5. Click [Close].

Register the turret load

1. Click [Turret] and [Turret Load].


Operation ⇒ Refer [Setting items in “Turret Load”])
(⇒

2. Change turret load as desired.


3. Click [Reg Tool Layout].
4. Click [OK].
● You can register only one turret load under same name. Turret will be over
Caution
written when you register turret load.

5. Click [Close].

6-4
Auto tool load to the turret
Automatically load used tool on the sheet to empty stations in the turret 6
AP100G CAM Operation Guide I NCT

from outside the turret. (Or, replaces tool with a tool unused in the same
station size or key spec.) Change
1. Click [Turret] and [Turret Load]. Turret Load
Operation
⇒ Refer [Setting items in “Turret Load”])
(⇒

2. Click the [Auto Setup] button in the [Turret Load] dialog box.
● The tool replaced is moved to the list of [Outside Turret].
● When [Previous T Number] is displayed, load tools to the previous T number.
Tips
When the target station is locked or used tool is in already, load tools to
another station.

6-5
How to read the [Turret Load] dialog box

List Display (Default) 6


AP100G CAM Operation Guide I NCT

Change
Turret Load

# Search, Shape, Range


Filter tools by shape and station size. The list will show different tools
based on filter selected and quantity will be updated.
# [Reg tool Layout]
Save turret load as standard turret load.
# [View Condition]
Change items to display on the list.
# The button to change display mode.
It is valid for punching except LIBRA205/LIBRA206/MERC722.
button change to turret view. (Graphic). When the graphic turret
is displayed, button change mode to list display
# Turret
Tools in the turret. Any tool can be added, moved and removed. Also, tool can be
moved between inside and outside of the turret by / button.

6-6
! T number
Type in station number to move cursor on the list. When the
[Enter] key is hit after typing in the station number, tool setup
dialog box for that station appears. 6
AP100G CAM Operation Guide I NCT

! [Setup]
Change
Setup tool information for specified station.
Turret Load
! [Delete]
Remove tool from turret.
! [Move]
Move tool from one station to the other.
! [Change Current]
Set selected tool as current tool.
! [Print Turret]
Print out graphic view of turret except for LIBRA205/LIBRA206
/MERC722.
# [Tooling Layout Auto Setup]
Load tools from outside turret to turret automatically. It looks for
empty station with same size and key spec to load tools.
# [Outside Turret]
List of tools picked from inventory by Auto Assignment or [Add
Available Tool] manually.
! [Add Available Tool]
Add tool from inventory to [Outside Turret].
! [Setup]
Change tool.
! [Delete]
Remove tool from Outside Turret.
! [Change Current]
Set selected tool as current tool.

6-7
Turret Diagram display
This is not available for LIBRA/ MERC/ Non-Amada machine.

6
AP100G CAM Operation Guide I NCT

Change
Turret Load

Items on this view are same except items below.


Note
# The button to change display mode.
Changes display to list.

#
Rotate turret.

6-8
Settings in the [Change Tool Information] dialog box
(NCT/Combination)

6
AP100G CAM Operation Guide I NCT

Change
Turret Load

Tips
Items are different depend on shape.
# T number
Station number
# Shape
Tool shape.
# Management Name
Punch name for control. Click [Browse], and then select a name from
the [Tools] dialog box. (Tool list from your inventory)
For special, forming and triangular tools, [Graphics>>] button shows
up. You can change display of special shape tools.
# Size
Enter the X, Y, and R size of the tool.
# Angle
Enter an angle to set a tool on the turret.

6-9
# Type
Shape sub code. You can specify the shape sub codes below.
$ RE/OB/RR:
Normal, nesting (shearing tool) and slotting for VIPROS 6
$ Special/forming/marking:
AP100G CAM Operation Guide I NCT

Change
Not keyed, keyed and slotting 2 for VIPROS
$ Tapping: Turret Load
Tapping II, tapping unit, tapping tool
$ Triangle:
Isosceles, right and other triangles
# Usage
Specify a tool application from the following.
$ FORMING PROTOTUDE:
Used for sequencing control.
$ PIERCE PUNCH:
Used for specifying pierce punch for ALPELI. It is Not used for
punching.
$ OUTER SHAPE CUT:
Used for perimeter cutting with auto assignment.
$ NIBBLING:
Used for nibbling with auto assignment.
$ SCRAP CUT:
Not used
$ FINAL CUT:
Not used
$ LIBRA (FORM UP):
Used for LIBRA.

$ LIBRA (FORM DOWN):


Used for LIBRA.
# VIPROS M-code
M code for VIPROS NC program.
# Slotting Name
Parameter name to compute the maximum process length and pitch for
slotting.

6-10
# Up/Down M-code
Displays an M code added to a NC program for the machine that has
P&F structure.
# Axis Speed
$ F3000C: 0 to 3 6
AP100G CAM Operation Guide I NCT

$ Other than F3000C: 0 to 4 Change


# Tool Angle
Specify the slope of a tool set at the 0 degree key. Turret Load
# Comment
Enter a punch comment.
# Air Blower
Specify if the tool has air blow.
# Energy-save Tooling
Specify if the tool is an efficient tool. (Special tool with height
adjusted.) If it is, set [Energy-save Tooling].
# Fixed/free
Specify a station type.
$ Fixed: Locked station (The tool stays as standard turret load.)
$ Free: Free station (Used for exchanging/temporary tools)
Die information
# Management Name
Die name for tool control.
# Clearance
Clearance between punch and die .
# Comment
Die comment.
# [Register Hold Tooling]
Register a new tool to inventory without going to parameter screen.
This button is grayed out if you do not set [Shape], or if you select a
special, forming, triangular, or if you have entered a tool name that is
already exist in inventory.
If you click [Register hold Tooling] with [Management Name] blank,
the [Register Tool] dialog box appears. Input management name and
hit OK to register.

6-11

You might also like