WEMCO T – 1414 B
SANTAN PROCESS
KLO
Reliability Engineering & Asset Integrity Team
Date:
REVISION HISTORY
Change Log
Document Holds
Holds:
Table of Contents
2
Asset Integrity Analysis of WEMCO
1. Introduction …………………………………………………………………… 4
2. Objectives (Scopes) …………………………………………………………… 4
3. Standards and References ……………………………………………………… 4
4. Data …………………………………………..………………………………… 4
5. Inspection Condition ………………………………………………………….... 5
6. Inspection Data & Summary ………………………………………………….. 5
7. Data Analysis …………………………………………………………………... 14
8. Final Recommendation ………………………………………………………… 15
3
Asset Integrity Analysis of WEMCO
1 Introduction
The WEMCO is the Trade-Mark derived from name of the Founding Company. The
WEMCO Depurator is used to remove oil and suspended solids from liquid. In this process
free oxygen is removed from the liquid if gas other than air is utilized. Conversely, an
oxygen deficient liquid is oxygenized by the use of air. The WEMCO Depurator
accomplishes this by introducing a large volume of finely disseminated gas bubbles into the
liquid. Under the proper conditions of chemical treatment, the contaminating oil and solid
particle become attached to gas bubbles and are carried to the surface of the liquid to the
removed as float material by the Depurator skimmers.
2 Objectives (Scope)
To develop comprehensive assessment for WEMCO Depurator T-1414 B Santan Process,
which include :
Conduct visual inspection and thickness measurement on shell, and piping system.
Calculation Remaining life Assessment
Final Recommendation
4 Data
Tag No : T-1414 B
Serial No : 8150459
Description : WEMCO Depurator
Service : Liquid
Capacity :-
Design Pressure : Atmospheric
Design Temperature : - oF
Material : Unknown
Corrosion Allowance :-
Manufacturer : WEMCO
Year Built : 1972
Design Code :-
4
Asset Integrity Analysis of WEMCO
5 Inspection Condition:
Inspection date : December 16, 2018
Type of Inspection :
Visual Inspection
UT Thickness
West Side
South Side
5
Asset Integrity Analysis of WEMCO
North Side
Finding:
Slight external corrosion has occurred on shell due to dirty condition.
Top Side
Finding:
Medium external corrosion has occurred on shell due to painting damage.
Level Control
Finding:
Medium to heavy external corrosion has occurred on chamber, flanges and
bolts/nuts.
6
Asset Integrity Analysis of WEMCO
Level Glass
Finding:
Heavy external corrosion has occurred nipple and coupling.
Medium external corroded on Level glass.
b. UT Thickness Measurement
7
Asset Integrity Analysis of WEMCO
8
Asset Integrity Analysis of WEMCO
9
Asset Integrity Analysis of WEMCO
Finding:
Minimum thickness based on UT Thickness: (Nominal Thickness: 10 mm)
East Side : 7.00 mm (CML – B2-1)
West Side : 8.41 mm (CML – B1-1)
South Side : 12.12 mm (CML – B-4)
North Side : 10.12 mm (CML – D-1)
Bottom Side : 9.79 mm (CML – D-4)
Top Side : 6.68 mm (CML – J-1)
10
Asset Integrity Analysis of WEMCO
Finding:
No significant metal loss
11
Asset Integrity Analysis of WEMCO
Finding:
No significant metal loss
Slighly external corrosion due to painting demage at some location pipe spool
12
Asset Integrity Analysis of WEMCO
Finding:
Internal corrosion has been occurred on Inspection points P.5 (Remain
Thickness : 3.58 mm & P.6 (Remain thickness 2.84 mm). Nominal thickness
7.11 mm (metal loss > 50%)
13
Asset Integrity Analysis of WEMCO
2 Data Analysis :
7.1 WEMCO
In generally, the shall plate has been in a dirty condition due to the splash of liquid from
WEMCO which take place for long time, so that it can slight external corrosion in some
section of the shell plate, but at the top side there are medium external corrosion due to
painting damage. The remaining thickness in the area have medium external corrosion at
the top side is 6.68 mm from nominal thickness 10 mm. (metal loss approximate 30%).
2.1 PROCESS PIPING
Line : From 1170-A-16” to T-1414 A/B
Line No : 1171-U-24” & 16”
P&ID No : ST-PP_4121 2/3
In generally, these line piping is in good condition. The results of thickness
measurements have no significant metal loss.
Result of thickness measurement in this line piping have been found internal
corrosion at inspection point P5. And P.6 with minimum remaining thickness 2.84
mm from nominal thickness 7.11 (metal loss >50%).
Based on RLA calculation obtained thickness requirement 2.80 mm, almost close to
the minimum remaining thickness is 2.84 mm and corrosion rate 0.175 mm/year
14
Asset Integrity Analysis of WEMCO
3 Final Recommendation :
Sandblasting and repainting the shell plate of WEMCO.
Replace line piping with line no 1174-U-16” ( from E4 to P.5) with new spool.
15