You are on page 1of 1

DI No: F/002/QF-SQ-COM/002

Rev.02 Dtd : 03/07/2019


Supplier Process Audit (General)
Supplier Name : Rockman Industries Supplier Location : Tirupati Yellow
Supplier Team : Maheshkumar, ganesamoorthi Process : Casting, machining , powder coating, painting YELLOW
Auditors:S.Perumal Date of Audit : 28.11.23 YELLOW
Part Name : Alloy wheel Front & Rear Model :Hunter, New classic , Meteor & Hunter RED
Part Number : ALL models Type of Audit: Process audit RED
RED

Observation Alotted Actual


Sl.No Category Requirements Check Points Observations RED Action plan Responsibility
Category Score score

Yes, Latest drawing and the TDL Available with the supplier
Is there a dwg / TDL available with supplier as per Ref; RAT 00077/E; Dr - 34778
1 Conformance 5 5 RED
latest DR?

Updated AOI available with the supplier as per the latest


drawing
2 Product Dwg , RE TDL & AOI Whether the Agreed AOI is available and followed? Non Conformance 5 5 RED

NA
3 Does the supplier has Aesthetic Standard & followed? Conformance 5 5 RED

PPM for the year 23-24


May-3058, Jun-21723, Jul- 5894, Aug-50482, Sep-41329
4 Actual ppm for the part Non Conformance 5 1 RED

Last 6 months PPM Trend & Rework data for the PDI not available and the action plan to
Improvement action plan reduce the rework not evident
Is there are a clear action plan identified &
5 Non Conformance 5 1 RED
Market implemented for PPM reduction
Complaint &
warranty
yes, four issues reported from the field
is there any issue at Field on account of the part non
6 Non Conformance 5 1 RED Share the action plan to RE Mr. Munireddy V
conformance ?
Market complaint & warranty
Action received for the crack issue ;
7 whether the actions are implemented & sustained? But the action plan not received for the Paint peel off issue Non Conformance 5 1 RED Share the action plan to RE Mr. Munireddy V

Total raised points : 17


8 Total no. of actionable points raised vs Closed Total closed points : 05 Non Conformance 5 1 RED
Previous Process audit Total open points - 12
observations & its closure
status
Is the action identified & implemented for all the No, Actions are implemented for the closed points not for
9 Non Conformance 5 1 RED
points raised ? the all points

Whether all the QRQC issues are responded with Last six month 12 QPH raised and closed
10 Action? Conformance 5 5 RED
- mention no of QRQC raised vs QPCA Submitted
Corrective &
Preventive Not in live , Improper shot blasting issue and rework after
actions is corrective action implemented as per QPCA & is that post casting still persist
11 Non Conformance 5 5 RED
live in shop floor?

Corrective & Preventive


Actions
12 Are there any QRQC issue repeated in last one year? Yes,damage, casting flash issues are repeated Non Conformance 5 5 RED

whether all the actions are horizontally deployed for As discussed our process ownars there is no posiple for
Horizontal deployment not evident for the balancing auto
13 applicable models of RE & applicable machines within Non Conformance 5 1 RED the exiting machine auto punch setup due to part bend
punch mark in J1C alloy wheel
supplier's shop floor and damage. kindly close the point.

DI.N.O.F/002/QF-SQ-COM/002