OTHER LOADS:
ONE-800W REFRIGERATOR: =1500VA
PROVIDE 1-30A REFRIGERATOR CIRCUIT
CIRCUIT REQUIREMENTS:
USE 5-15A 2-WIRE BRANCH CIRCUITS, 3 - 20A 2-WIRE BRANCH CIRCUITS
SERVICE EQUIPMENT:
(A) MAXIMUM CURRENT RATING OF PROTECTIVE DEVICE
AIR CONDITIONING LOAD: (SEE SEC. 2.20.3.23 & TABLE 4.30.14.2, PEC-2017)
ONE 1HP ROOM AIR CONDITIONING UNIT
12A x 230V x 3 =8,280VA
PROVIDE 4-30A ROOM ACU CIRCUIT
OTHER LOADS:
CIRCUIT REQUIREMENTS:
USE 4-15A 2-WIRE BRANCH CIRCUITS, 4 - 20A 2-WIRE BRANCH CIRCUITS, 6 - 30A 2 -
WIRE BRANCH CIRCUITS
SERVICE EQUIPMENT:
(C) MAXIMUM CURRENT RATING OF PROTECTIVE DEVICE
(SEE SECTION 4.30.4.2 AND TABLE 4.30.4.2)
(3) NONTIME DELAY FUSE
[300%(2760) + 11,040+ 6,260 + 1,200 ] / 230V =84.48A
DISTRIBUTION PANEL 1
DISTRIBUTION PANEL 2
Transformer Multiplier, M.
M = 100 / % Z
M = 100/2.4
M = 41.67
ISCT = IFL x M
ISCT = 326.10 x 41.67
ISCT = 13,586.96 Amperes
f = (2 x L x ISC) / (c x n x EL−N)
f = (2 x L x ISC) /(c x n x EL−N )
f = (2 x 65.62 x 13,586.96) /(18594 x 2 x 230)
f = 0.104
M2 = 1/ (1 + f )
M2 = 1/1 + 0.104
M2 = 0.91
Therefore Use : 250AT, 250AF, 2P, 230V, 60Hz, 15kAIC Molded Case Circuit Breaker
Minimum Current Interrupting Capacity: 15kAIC
SERVICE ENTRANCE
C1 – LIGHTING OUTLET
C2 – LIGHTING OUTLET
C3 – LIGHTING OUTLET
C4 – LIGHTING OUTLET
C5 – LIGHTING OUTLET
C7 – CONVENIENCE OUTLET
C8 – CONVENIENCE OUTLET
C9 – REF OUTLET
C1 – LIGHTING OUTLET
C2 – LIGHTING OUTLET
C3 – LIGHTING OUTLET
C4 – LIGHTING OUTLET
ESTIMATE | 3
BECHAYDA’S RESIDENTIAL
C5 – CONVENIENCE OUTLET
C6 – CONVENIENCE OUTLET
C7 – CONVENIENCE OUTLET
C8 – CONVENIENCE OUTLET
ESTIMATE | 5
BECHAYDA’S RESIDENTIAL
ESTIMATE SHEET FOR RESIDENTIAL
COST ANALYSIS
UNIT TOTAL
(PHP) (PHP)
CIRCUIT BREAKER
CASING
ESTIMATE | 6
BECHAYDA’S RESIDENTIAL
CONDUIT / RACEWAY
MISCELLANEOUS
TOTAL 323,792.21
ESTIMATE | 7