TERMITE PROTECTION GENERAL DEMOLITION NOTES DEMOLITION PLAN LEGEND

1/1
EXISTING REINFORCED CONC.
PLANO:
AS PER FBC 2017 COLUMN OR CONCRETE WALL
1. THIS DRAWING IS ONLY TO ASSIST IN SHOWING 5. CONTRACTOR IS TO PROTECT ALL UNDER- 8. PATCH AND REPAIR ALL EXISTING SURFACES 12. CONTRACTOR TO SURVEY PROJECT AREA TO REMAIN
· CERTIFICATE OF PROTECTIVE TREATMENT FOR · TERMITE PROTECTION (1816.1): SHALL BE PROVIDED BY THE SCOPE OF DEMOLITION WORK AND IS NOT GROUND OR OTHER CONCEALED UTILITIES HE IS DAMAGED BY DEMOLITION AND/OR INSTAL- PRIOR TO COMMENCEMENT OF WORK. EXISTING CMU WALL
PREVENTION OF TERMITES (105.1): A WEATHER-RESISTANT REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED
INTENDED TO INDICATE ALL DEMOLITION. TO INSPECT CEILING AND CHASES TO ASSURE LATION OF NEW ELECTRICAL CONDUITS, GAS NOTE AND REPAIR ANY DAMAGE TO AREAS TO REMAIN PROJECT:
CONTRACTOR SHALL REMOVE ALL EXISTING PROPER IDENTIFICATION OF UTILITIES. PIPING, ETC.. AS REQUIRED TO MATCH WHERE WORK IS GOING TO BE PERFORMED.
JOB-SITE POSTING BOARD SHALL BE PROVIDED TO PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED ITEMS AS REQUIRED TO COMPLETE THE JOB. MECHANICAL AND/OR ELECTRICAL ADJACENT SURFACES AND/OR AS REQUIRED NOTIFY OWNER AND ARCHITECT WITH A LIST EXISTING WALL OR
RECEIVE DUPLICATE TREATMENT CERTIFICATES SHALL BE TO WOOD, OR OTHER APPROVED METHODS OF TERMITE CONTRACTOR ARE TO CAP THEM AS REQUIRED. FOR NEW SCHEDULED FINISHES. OF WORK PRIOR TO CONTRACT. PARTITION TO REMAIN
PROVIDED AS EACH REQUIRED PROTECTIVE TREATMENT PROTECTION LABELED FOR USE AS A PREVENTATIVE 2. NOT ALL ITEMS TO BE DEMOLISHED ARE
IS COMPLETED, SUPPLYING ONE COPY FOR THE PERSON TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION SHOWN ON THE PLAN. CONTRACTOR SHALL BE 6. CONTRACTOR IS TO SAW-CUT ALL OPENINGS 10. PREPARE EXISTING CONCRETE SLAB AS REQ. WALL OR PARTITION WITH
THE PERMIT IS ISSUED TO AND ANOTHER COPY FOR THE OF THE APPLICATION OF THE TERMITE PROTECTIVE RESPONSIBLE FOR PERFORMING A WALK-THRU IN CONCRETE BLOCK WALLS IF REQUIRED. BY GRINDING, LEVELING WITH ARDEX LEVELER 13. THIS SET OF DRAWINGS IS TO BE USED AS A UNIT. EXISTING DOOR TO REMAIN
OF THE PROJECT PRIOR TO SUBMITTING A BID CONTRACTOR SHALL NOT DEMOLISH OPENINGS AS PER MANUFACTURERS SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE FOR ALL DISCIPLINES,
BUILDING PERMIT FILES. THE TREATMENT CERTIFICATE
SHALL PROVIDE THE PRODUCT USED, IDENTITY OF THE
TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE
ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED
TO THE OWNER FOR IDENTIFYING POSSIBLE
CRITICAL ITEMS, NOT OR INCORRECTLY
ADDRESSED, WHICH REQUIRE REMOVAL/
WITH SLEDGE HAMMER UNTIL OUTLINES HAVE BEEN CUT. MATCH EXISTING SLAB ELEVATION AS
REQUIRED TO RECEIVE NEW SCHEDULED
FLOORING MATERIAL.
& SHOULD INCLUDE EVERYTHING THAT IS NEEDED
FOR MAKING ALL SYSTEMS WORK.
EXAMPLE: IF A SINK IS SHOWN IN THE ARCHITECTURAL
EXISTING WALL OR
PARTITION TO BE REMOVED
HOUSE
APPLICATOR, TIME AND DATE OF THE TREATMENT, SITE PEST CONTROL COMPANY THAT CONTAINS THE
LOCATION, AREA TREATED, CHEMICAL USED, PERCENT FOLLOWING STATEMENT: “THE BUILDING HAS RECEIVED A RELOCATION. 7. CONTRACTOR SHALL VERIFY EXACT LOCATION
OF EXISTING CMU BLOCK WALLS IN AREAS
PLANS, IT IS ASSUMED THAT THE G.C. IS PROVIDING 0000 NW 0 St.
EVERYTHING NEEDED, A/E WILL PROVIDE THEM WALL OR PARTITION WITH
CONCENTRATION AND NUMBER OF GALLONS USED, TO
ESTABLISH A VERIFIABLE RECORD OF PROTECTIVE
COMPLETE TREATMENT FOR THE PREVENTION OF
SUBTERRANEAN TERMITES. TREATMENT IS IN 3. PROVIDE SAFETY FEATURES DURING WORK
WHERE WALLS ARE BEING REMOVED AND
INFORM ARCHITECT OF ANY CONFLICTS
11. DESTINATION OF ALL EXISTING EQUIPMENT,
PLUMBING FIXTURES, DOORS AND FRAMES, ETC.
WITH THE UNDERSTANDING THAT THERE WILL BE
NO ADDITIONAL COST TO OWNER.
EXISTING DOOR TO BE REMOVED MIAMI, FL.
AS CALLED FOR IN APPLICABLE CODES, RULES TO BE REMOVED SHALL BE COORDINATED
TREATMENT. IF THE SOIL CHEMICAL BARRIER METHOD FOR ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY AND REGULATIONS HAVING JURISDICTION OF
BEFORE ANY WALLS ARE REMOVED SO
THAT A/E CAN INSPECT THEM FOR WITH THE OWNER. 00000
TERMITE PREVENTION IS USED, FINAL EXTERIOR THE FLORIDA DEPARTMENT OF AGRICULTURE AND THE PROJECT. CLARIFICATION PRIOR TO PROCEEDING WITH
DEMOLITION SYMBOL
TREATMENT SHALL BE COMPLETED PRIOR TO FINAL CONSUMER SERVICES.” WORK. 7 (SEE DEMOLITION NOTES)
BUILDING APPROVAL. FOR A BAIT SYSTEM, SEE SECTION 4. CUT, REMOVE, PATCH, ALTER AND REFINISH OWNER:
1816.1.7 OF THE FLORIDA BUILDING CODE FOR CONTRACT EXISTING CONSTRUCTION AS REQUIRED TO 9. DEMOLITION IS DENOTED BY BROKEN LINES.
LEAVE WORK COMPLETE AND IN SATISFACTORY DENOTES EXISTING AREAS
DOCUMENT REQUIREMENTS. MANNER. OUTSIDE THE SCOPE OF WORK
xxxxxxxxxxxxxxxxxx
LEGAL DESCRIPTION
CONTENT:
LOT 2, BLOCK 1, OF KENDALL SECTION ONE SUBDIVISION
ACCORDING TO THE PLAT THEREOF AS RECORDED IN - DEMOLITION FLOOR PLAN
PLAT BOOK 79 AT PAGE 63 OF THE PUBLIC RECORDS OF
DADE COUNTY, FLORIDA.
-
-
EXISTING CONDITIONS -
THIS PLAN WAS PREPARED BY UTILIZING THE EXISTING -
CONSTRUCTION DOCUMENTS FOR THIS RESIDENCE &
FIELD VERIFICATION. IT IS NOT THE INTENT OF THIS PLAN
TO REPLICATE ALL EXISTING CONDITIONS. ALL
CONCERNED PARTIES AND BIDDERS SHALL VISIT THE ARCHITECT OF RECORD:
SITE AND FAMILIARIZE THEMSELVES WITH ALL
CONDITIONS SURROUNDING THE SCOPE OF WORK. IT IS
THE RESPONSIBILITY OF ALL CONCERNED PARTIES TO
VISIT THE SITE & ACQUAINT THEMSELVES WITH THE
AVAILABLE INFORMATION. CESAR FERNANDO MONTES
CC No. 1.118.533.503
SCOPE OF WORK

FAMILY ROOM THEATRE CONSISTS ON RENOVATING THE INTERIOR SPACES OF


AN EXISTING ONE-STORY RESIDENCE. UPGRADES SHALL
COMMENTS:
14'-3" x 37'-10" 14'-3" x 18'-4" INCLUDE NEW FINISHES, WALLS, DOORS, AND BATHROOM
FIXTURES. STRUCTURAL WORK SHALL BE PROVIDED
ACCORDINGLY. MECHANICAL AND ELECTRICAL SYSTEMS
NOT PART OF THIS SCOPE OF WORK.

EL. 1'-9"
FIN. FLR. DEMOLITION NOTES:

1
DEMOLISH PORTION OF CONCRETE WALL
INCLUDING HEADERS AND BEAMS. PROVIDE
7" 7"
SHORING AS REQUIRED FOR PROTECTION OF ARCHIVO CAD:
ROOF DURING CONSTRUCTION. REFER TO
STRUCTURAL DRAWINGS.
BATH REMOVE EXISTING FLOOR FINISH, SLAB, STEPS, MIAMI INN 2.0.dwg
5'-10" x 7'-4" EL. 2'-2" 2
DOWN TO THE EXISTING SOIL OR CONC. SLAB, AS
FIN. FLR. REQUIRED TO POUR NEW FLOOR SLAB AT 0'-0".
REFER TO SHEET A-3 FOR THE LEVELED AREAS. SCALE:
DINING KITCHEN FOYER REMOVE EXISTING FLOOR TILES AND WALL BASE.
12'-9" x 15'-9" 12'-9" x 15'-9" 12'-9" x 12'-9"
3
GRIND CONCRETE SLAB AS REQUIRED TO ACCEPT
NEW CONCRETE INFILL. REFER TO SHEET A-3 FOR
############
4 6 INFILL AREAS.

UTILITY REF M. BATH REMOVE EXISTING FLOOR TILES - PATCH AND DATE:
4'-10" x 8'-5"
4
EL. 2'-2" LEVEL FLOOR TO RECEIVE NEW FINISH.
6'-4" x 7'-4"
EL. 2'-2"
FIN. FLR.

BATH
5
REMOVE EXISTING LOW WALL INCLUDING abril 19, 2022
M. BEDROOM
EXISTING CABINETRY, WOOD TRIMS, DRYWALL,
FIN. FLR.
AND ARCHES ABOVE. EXISTING CONC. BEAM TO
11'-10" x 8'-8"
11'-10" x 15'-11"
REMAIN.
4 6 SHELVES DATE: REVISIONS:
REMOVE ALL EXISTING WOOD CEILINGS, GYPSUM

SHELVES
6
10 11
WALK-IN CLOSET BOARD AND/OR PLASTER CEILINGS, INCLUDING
FANS AND FIRE DEVICES. SALVAGE EXISTING
06-07.21 1 AS-BUILT COORDINATION
UP 6'-5" x 8'-8" EL. 2'-2" LIGHT FIXTURES AS DICTATED BY OWNER.
FIN. FLR.
7
COMPLETELY REMOVE EXISTING WOOD STUD
PARTITION INCLUDING WOOD TRIMS AND ARCHES.
SHELVES RELOCATE EXISTING ELECTRICAL OUTLETS AND
EL. 0'-0"
FIN. FLR. DEVICES AS PER CODE.

HALL
8 REMOVE EXISTING HEADER AND WOOD ARCH.
SHELVES
FOYER 3'-2" x 23'-1" 9 REMOVE EXISTING DOOR AND FRAME.

15'-2" x 25'-5" 10
REMOVE EXISTING PLUMBING FIXTURES - CAP-OFF
PLUMBING LINES AS REQUIRED TO RE-ROUTE
EL. 2'-2" THEM TO NEW LOCATION AS PER PLANS.
2 CAR GARAGE FIN. FLR.

SHELVES
REMOVE EXISTING BUILT-IN CASEWORK,
21'-1" x 21'-4" 11
SHELVING, AND ACCESSORIES.
SEAL:
EL. 2'-2"
BETROOM 3 REMOVE PORTION OF EXISTING WOOD STUD WALL
BETROOM 1 BETROOM 2
12
FIN. FLR. AS REQUIRED FOR OPENING OF NEW DOOR.
12'-11" x 12'-5"
11'-9" x 10'-10" 11'-9" x 10'-10" 13
RELOCATE EXISTING AIR HANDLER UNIT AS PER
PROPOSED FLOOR PLAN.
5" 4 6 4 6
14
COMPLETELY REMOVE SHOWER TILES AND
SHELVES

ACCESSORIES - LEVEL AREA AS REQUIRED FOR


FRONT PORCH NEW FINISH AS PER PLANS.

5'-11" x 24'-6"
EL. 1'-9"
FIN. FLR.

EL. 0'-0" EL. 0'-0"


FIN. FLR. FIN. FLR.

SHEET TITLE:

DEMOLITION FLOOR PLAN NORTH


XXXXXXX
SCALE: 1/4" = 1'-0" SHEET No.:

NOTE: AN ASBESTOS REPORT SHALL BE ISSUED AS PART OF THIS PROJECT BY THE OWNER. THE OWNER WILL PROVIDE THE ASBESTOS ABATEMENT IF REQUIRED. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE ASBESTOS REMOVAL AS PART OF THIS PROJECT.
A-1
WOOD NOTES FLOOR PLAN LEGEND
1/1
PLANO:
WHERE REQUIRED BY CODE, PROTECTION FROM DECAY AND TERMITES SHALL BE SLEEPERS AND SILLS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT
EXISTING CMU WALL
PROVIDED BY THE USE OF NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. CONTACT WITH EARTH SHALL BE OF NATURALLY DURABLE OR TO REMAIN
PRESERVATIVE-TREATED WOOD.
PROJECT:
WOOD INSTALLED ABOVE GROUND SHALL BE NATURALLY DURABLE WOOD OR WOOD STRUCTURAL MEMBERS THAT SUPPORT MOISTURE-PERMEABLE FLOORS OR EXISTING WALL OR PARTITION
PRESERVATIVE-TREATED WOOD THAT USES WATER-BORNE PRESERVATIVES, AND ROOFS THAT ARE EXPOSED TO THE WEATHER, SUCH AS CONCRETE OR MASONRY
SHALL BE TREATED IN ACCORDANCE WITH AWPA C2 OR C9 OR APPLICABLE AWPA SLABS, SHALL BE OF NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD NEW METAL STUD PARTITION
AWPA STANDARDS FOR ABOVE-GROUND USE. UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS MOISTURE (SEE FLOOR PLANS AND
BARRIER (PARTITION TYPE DETAILS)

WOOD FRAMING MEMBERS, INCLUDING WOOD SHEATHING, WHICH REST ON WALL OR PARTITION
PROTECTION OF WOOD
HOUSE

1234
EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES (203 MM) FROM WITH NEW DOOR AND DOOR NUMBER
(COORDINATE W/ DOOR SCHEDULE)
EXPOSED EARTH SHALL BE OF NATURALLY DURABLE OR PRESERVATIVE-TREATED ALL WOOD NOT SEPARATED FROM AND/OR IN DIRECT CONTACT WITH CONCRETE
WOOD. WOOD FRAMING MEMBERS AND FURRING STRIPS ATTACHED DIRECTLY TO MASONRY, INCLUDING SILLS, SLEEPERS, PLATES, POSTS, COLUMNS, BEAMS, GIRDERS NOTE:
MASONRY OR CONCRETE WALLS SHALL BE OF APPROVED NATURALLY DURABLE OR AND FURRING; SHALL BE TREATED IN AN APPROVED METHOD WITH AND APPROVED BROKEN LINE DOOR INDICATES 0000 NW 0 St.
PRESERVATIVE-TREATED WOOD. PRESERVATIVE, OR SHALL BE OF AN APPROVED DURABLE SPECIES. DOUBLE ACTING DOOR
MIAMI, FL.
1234 ROOM NUMBER SYMBOL
(REFER TO ROOM FINISH SCHEDULE)
00000
PARTITION TYPES SYMBOL
8 (REFER TO PARTITION TYPE OWNER:
DETAILS AND NOTES) SHT. A-6

1
INTERIOR ELEVATION SYMBOL
(SEE INTERIOR ELEVATIONS)
SHT. A-4
xxxxxxxxxxxxxxxxxx
STOREFRONT / WINDOW OR
6 BORROWED LIGHT SYMBOL
CONTENT:
- PROPOSED FLOOR PLAN
1
DETAIL SYMBOL -
A- W/ DRAWING AND SHEET NUMBERS
-
REVISION SYMBOL -
(REFER TO COVER SHEET
3 FOR REVISION INFORMATION) -

OUT OF SCOPE OF WORK

ARCHITECT OF RECORD:

1
PRE-FABRICATED WALL HUNG VANITY BY "DOMANI" CESAR FERNANDO MONTES
PROVIDE WALL BACKING AS PER DETAIL B SHT. A-4
CC No. 1.118.533.503
MODULAR WALL HUNG WARDROBE BY "DOMANI"
2

M. BEDROOM
PROVIDE WALL BACKING AS REQUIRED BY
FAMILY ROOM MANUFACTURER'S RECOMMENDATIONS. COMMENTS:
14'-3" x 37'-10" 14'-3" x 18'-4" CEILING MOUNTED SHOWER HEAD AS SELECTED BY
3
OWNER.

WALL MOUNTED BIDET SHOWER HEAD AS SELECTED


4
EL. 1'-9" BY OWNER.
FIN. FLR.
PROVIDE NEW CERAMIC TILE FLOORING AS
5
SELECTED BY OWNER

6 PROVIDE NEW HARD CEILING WITH PAINT FINISH.


4"
ARCHIVO CAD:
NEW BUILT-IN BENCH WITH TILE FINISH.
SHELVES 7

BATH MIAMI INN 2.0.dwg


5'-10" x 7'-4" EL. 2'-2"

SHELVES
FIN. FLR.
SCALE:
KITCHEN
REF M. WK CLOSET
12'-9" x 15'-9"
12'-9" x 7'-1"
############
BATH 3
SHELVES
UTILITY DATE:
EL. 2'-2" 4'-10" x 8'-5"
6'-4" x 7'-4"
EL. 2'-2"
FIN. FLR.
abril 19, 2022
FIN. FLR.
SHELVES BEDROOM 3
M. BATH SHELVES 11'-10" x 15'-11" DATE: REVISIONS:
11'-10" x 7'-1"
WALK-IN CLOSET 06-07.21 1 AS-BUILT COORDINATION
UP 6'-5" x 8'-8" EL. 2'-2"
FIN. FLR.

SHELVES
EL. 0'-0"
FIN. FLR.

HALL SHELVES
FOYER 3'-2" x 23'-1"

15'-2" x 25'-5"
EL. 2'-2"
2 CAR GARAGE SHELVES SHELVES
FIN. FLR.

21'-1" x 21'-4"
WK CLOSET 1 WK CLOSET 2 SEAL:
EL. 2'-2" 4'-6" x 5'-6" 4'-6" x 5'-4" BETROOM 2
FIN. FLR.
BETROOM 1 12'-11" x 12'-5"
11'-9" x 10'-10"
4"
BETROOM 1 BETROOM 2
FRONT PORCH 5'-9" x 5'-6" 5'-9" x 5'-4"

5'-11" x 24'-6"
EL. 1'-9"
FIN. FLR.

EL. 0'-0" EL. 0'-0"


FIN. FLR. FIN. FLR.

SHEET TITLE:

PROPOSED FLOOR PLAN NORTH


XXXXXXX
SCALE: 1/4" = 1'-0" SHEET No.:

NOTE: AN ASBESTOS REPORT SHALL BE ISSUED AS PART OF THIS PROJECT BY THE OWNER. THE OWNER WILL PROVIDE THE ASBESTOS ABATEMENT IF REQUIRED. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE ASBESTOS REMOVAL AS PART OF THIS PROJECT.
A-2
FLOOR PLAN LEGEND
1/1
PLANO:
EXISTING CMU WALL
TO REMAIN

PROJECT:
EXISTING WALL OR PARTITION

NEW METAL STUD PARTITION


(SEE FLOOR PLANS AND
(PARTITION TYPE DETAILS)

HOUSE
OUT OF SCOPE OF WORK

FLOOR LEGEND 0000 NW 0 St.


FLOOR AREAS TO BE INFILLED W/
MIAMI, FL.
LIGHTWEIGHT CONCRETE AS REQUIRED TO
REACH PROPOSED ELEVATION AS SHOWN.
00000
GRIND EXISTING CONC. AS NEEDED TO
ACHIEVE A GRIPPING SURFACE FOR NEW
CONCRETE POUR. OWNER:
FLOOR AREAS TO BE LEVELED AT 0'-0"
A.F.F. - GRIND EXISTING CONC. SLAB AS
REQUIRED TO LEAVE A LEVELED SURFACE
xxxxxxxxxxxxxxxxxx
AND ACHIEVE IDEAL SUBSTRATE FOR NEW
FINISH.
CONTENT:
- SLAB DEPRESSION PLAN
-
-
-
-

ARCHITECT OF RECORD:

CESAR FERNANDO MONTES


CC No. 1.118.533.503

FAMILY ROOM M. BEDROOM COMMENTS:


14'-3" x 37'-10" 14'-3" x 18'-4"

EL. 1'-9"
FIN. FLR.

ARCHIVO CAD:
SHELVES
BATH MIAMI INN 2.0.dwg
5'-10" x 7'-4" EL. 2'-2"

SHELVES
FIN. FLR.
SCALE:
KITCHEN
REF M. WK CLOSET
12'-9" x 15'-9"
12'-9" x 7'-1"
############
BATH 3
SHELVES
UTILITY DATE:
EL. 2'-2" 4'-10" x 8'-5"
6'-4" x 7'-4"
EL. 2'-2"
FIN. FLR.
abril 19, 2022
FIN. FLR.
SHELVES BEDROOM 3
M. BATH SHELVES 11'-10" x 15'-11" DATE: REVISIONS:
11'-10" x 7'-1"
WALK-IN CLOSET 06-07.21 1 AS-BUILT COORDINATION
UP 6'-5" x 8'-8" EL. 2'-2"
FIN. FLR.

SHELVES
EL. 0'-0"
FIN. FLR.

HALL SHELVES
FOYER 3'-2" x 23'-1"

15'-2" x 25'-5"
EL. 2'-2"
2 CAR GARAGE SHELVES SHELVES
FIN. FLR.

21'-1" x 21'-4"
WK CLOSET 1 WK CLOSET 2 SEAL:
EL. 2'-2" 4'-6" x 5'-6" 4'-6" x 5'-4" BETROOM 2
FIN. FLR.
BETROOM 1 12'-11" x 12'-5"
11'-9" x 10'-10"

BETROOM 1 BETROOM 2
FRONT PORCH 5'-9" x 5'-6" 5'-9" x 5'-4"

5'-11" x 24'-6"
EL. 1'-9"
FIN. FLR.

EL. 0'-0" EL. 0'-0"


FIN. FLR. FIN. FLR.

SHEET TITLE:

SLAB DEPRESSION PLAN NORTH


XXXXXXX
SCALE: 1/4" = 1'-0" SHEET No.:

NOTE: AN ASBESTOS REPORT SHALL BE ISSUED AS PART OF THIS PROJECT BY THE OWNER. THE OWNER WILL PROVIDE THE ASBESTOS ABATEMENT IF REQUIRED. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE ASBESTOS REMOVAL AS PART OF THIS PROJECT. A-3
PARTITION TYPES DOOR TYPES DOOR SCHEDULE
1/1
PLANO:
DOOR SIZE DETAILS HDW. FIRE
FLR. DOOR DOOR DOOR FRAME SET RATING REMARKS
NO. TYPE MAT. WTH. HGT. TH. MAT. JAMB HEAD TRESH. NO. (MIN.)
PROJECT:
WALL TYPE GENERAL NOTES: 100 B MTL/GL (2) 2'-8" 7'-0" 1-3/4" H.M. - - - - - EXISTING

102 B MTL/GL (2) 4'-0" 6'-8" 1-3/4" H.M. - - - - - EXISTING


1. GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE APPROPRIATE CONSTRUCTION OF ALL
103 B MTL/GL (2) 4'-0" 6'-8" 1-3/4" H.M. - - - - - EXISTING
WALL TYPES AND COORDINATION OF ALL MECHANICAL, ELECTRICAL, PLUMBING AND EXISTING CONDITIONS
ADJACENT TO SUCH WALLS. - - - - -
104A A WOOD 3'-0" 7'-0" 1-3/4" WOOD RELOCATED
2. ALL PARTITIONS SHALL BE 5" NOMINAL DIMENSION UNLESS OTHERWISE NOTED ON PLANS.
104B B MTL/GL (2) 2'-6" 6'-8" 1-3/4" H.M. - - - - - EXISTING
3. INTERIOR WALLS, PERMANENT PARTITIONS (RATED OR NOT) AND TEMPORARY PARTITIONS SHOULD LEVER
SUPPORT A MINIMUM OF (5) POUNDS PER SQUARE FOOT APPLIED PERPENDICULAR HANDLE 105 C WOOD 3'-0" 7'-0" 1-3/8" WOOD - H-1 - - - BARN DOOR

HOUSE

FIRST
TO THE WALL. - - - -
106 C WOOD 3'-0" 7'-0" 1-3/8" WOOD H-1 BARN DOOR
4. PROVIDE BACKING SUPPORT AT ALL PARTITIONS WHERE EQUIPMENT IS INDICATED TO BE MOUNTED.
107 C WOOD 3'-0" 7'-0" 1-3/8" WOOD - H-1 - - - BARN DOOR
5. INSTALL WOOD STUDS AT 16" O.C. WITH GYPSUM WALLBOARD HUNG VERTICALLY.
6. GENERAL CONTRACTOR TO VERIFY ANY EXISTING PARTITIONS WITH NEW WALL TYPE DESIGNATIONS
AND UP-GRADE AS REQUIRED TO REFLECT NOTED WALL TYPES.
108
109
A
C
WOOD
WOOD
2'-6"
2'-4"
7'-0"
7'-0"
1-3/4"
1-3/4"
WOOD
WOOD
-
-
-
-
-
-
-
-
-
-
EXISTING
BARN DOOR
0000 NW 0 St.
7. PROVIDE CONTINUOUS (UNINTERRUPTED BY FURRING) R-4.5 (MIN.) RIGID INSULATION BOARD AT ALL
EXTERIOR BLOCK/CONCRETE WALLS FACING AIR CONDITIONED SPACES. INSTALL FROM FINISH SLAB TO
UNDERSIDE OF STRUCTURAL DECK. GYPSUM WALLBOARD TO CONCEAL INSULATION TO UNDERSIDE OF
110 C WOOD 2'-4" 7'-0" 1-3/4" WOOD - - - - - BARN DOOR MIAMI, FL.
- - - - - 1
8.
OF ROOF TRUSSES.
ALL DIMENSIONS SHOWN ON FLOOR PLANS ARE EITHER ROUGH (STUD TO STUD) OR MASONRY (MASONRY
111
112
A
C
WOOD
WOOD
3'-0
2'-4"
7'-0"
7'-0"
1-3/4"
1-3/4"
WOOD
WOOD - - - - -
EXISTING
BARN DOOR
00000
(MASONRY TO MASONRY OR MASONRY TO STUD) TYPICAL U.O.N.
112A C WOOD 2'-6" 7'-0" 1-3/4" WOOD - - - - - BARN DOOR
9. ALL EXISTING MASONRY WALLS OR CONCRETE COLUMNS IN AREAS AFFECTED BY NEW RENOVATIONS
SHALL RECEIVE SCHEDULED FINISH ON 5/8" TYPE "X" GYPSUM WALLBOARD ON 3/4" WOOD FURRING
A B 1
STRIPS AT 16" O.C. (TYPICAL UNLESS OTHERWISE NOTED ON PLANS). OWNER:
WOOD/FLUSH GLASS / ALUM.
DOOR NOTES xxxxxxxxxxxxxxxxxx
1. ALL DOORS NOT MARKED ON FLOOR PLANS ARE EXISTING TO REMAIN.
EXISTING WOOD 2. PROVIDE SMOKE TIGHT CAULKING AROUND ENTIRE PERIMETER OF FRAMES.
CONTENT:
TRUSSES (TYP.) 3. USE DOUBLE (ATTACHED) 20 GAUGE METAL STUDS AT JAMB OF ALL DOOR OPENINGS IN METAL STUD PARTITIONS.
- ELEVATIONS
4. CONTRACTOR SHALL FIELD VERIFY THICKNESS OF ALL EXISTING PARTITIONS ACCOMMODATING NEW DOORS IN ORDER TO DETERMINE THE
"THROAT" DIMENSIONS OF NEW FRAMES. - SCHEDULES AND DETAILS
5. SEE FLOOR PLAN FOR EXACT DOOR SWING.
6. FOR DOOR JAMB, HEAD AND SILL DETAILS, SEE THIS SHEET.
-
7. ALL WOOD DOORS TO BE SOLID CORE UNLESS OTHERWISE NOTED. -
8. ALL DOORS SHALL BE PROVIDED WITH A 5/8" UNDERCUT. MAXIMUM CLEARANCE BETWEEN THE BOTTOM OF THE DOOR AND THE CONCRETE
SLAB SHALL BE 3/4" MAX. EXCEPT AT THRESHOLD CONDITIONS. -
9. CONTRACTOR SHALL VERIFY SIZE OF ALL DOOR OPENINGS AND CONTACT THE
ARCHITECT IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING DOORS AND/OR FRAMES.
\" DRYWALL 2" X 4" WOOD 10. USE LEVER HANDLES AT ALL LOCATIONS (EXCEPT AS OTHERWISE NOTED).KNURLED LEVER HANDLES SHALL BE PROVIDED AT ALL
CEILING TOP PLATE TELEPHONE CLOSETS, MECHANICAL AND ELECTRICAL ROOMS.
ARCHITECT OF RECORD:
11. DOOR NUMBERS CORRESPOND WITH ROOM NUMBERS FOR EASE OF IDENTIFICATION. SEE FLOOR PLANS FOR LOCATIONS.
12. ALL DOORS IN THE MEANS OF EGRESS SHALL BE SINGLE ACTION RELEASE, SHALL COMPLY WITH F.A.C.AND SHALL NOT REQUIRE THE USE
OF A KEY , TOOL OR SPECIAL KNOWLEDGE TO OPEN FROM THE EGRESS SIDE.

INTERIOR PARTITION C 13. CLOSET DOORS. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CLIENTS CAN OPEN THE DOOR FROM INSIDE THE CLOSET.
CESAR FERNANDO MONTES
2" X 4" WOOD STUD 14. BATHROOM DOORS. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT OPENING OF THE LOCKED DOOR FROM THE OUTSIDE
AT 16" O.C. BARN DOOR IN AN EMERGENCY. CC No. 1.118.533.503
N.T.S.
5/8" DRYWALL
BOTH SIDES
COMMENTS:
TYPE "X" AT DOOR DETAILS FINISH SCHEDULE
WET LOCATIONS
2" X 4" WD. BRACING ROOM WAINSCOT CEILING
AT MID- DEPTH FLR. NO.
ROOM NAME FLOOR BASE WALLS HGT. MAT. REMARKS
MAT. HGT.
100 LIVING ROOM C. TILE C. TILE GYPSUM WALLBD. - PAINT - - G.W.B. 8'-0"
101 DINING ROOM C. TILE C. TILE GYPSUM WALLBD. - PAINT - - G.W.B. 8'-0"
102 FAMILY ROOM C. TILE C. TILE PAINT - - G.W.B. 8'-0"
- -
* 103 KITCHEN C. TILE C. TILE PAINT G.W.B. 8'-4"
* - -
104 STUDY C. TILE C. TILE PAINT G.W.B. 8'-0"
FIRE TREATED 2X6 TRACK
SUPPORT BETWEEN WALL STUD 3-1/2" -
105 BEDROOM 1 C. TILE C. TILE GYPSUM WALLBD. - PAINT - G.W.B. 8'-0"
WALL BASE FRAMING TO SECURE BACKING TO

FIRST
- -
AS SCHEDULED GWB. FACE OF BACKER MUST BE
FLUSH WITH FACE OF STUDS TO
106 CLOSET C. TILE C. TILE GYPSUM WALLBD. - PAINT
-
G.W.B. 8'-0"
ARCHIVO CAD:
BOTH SIDES AVOID WALL DAMAGE. 107 BATH 1 C. TILE C. TILE GYPSUM WALLBD. - PAINT - G.W.B. 8'-0" TYPE '"X" MOLD RESISTANT G.W.B.
108 BEDROOM 2 C. TILE C. TILE PAINT ON EXIST'G G.W.B. - - G.W.B. 8'-0"
2 x 4 P.T. WOOD PLATE
TILE OR
CARPET
WITH CUT NAILS AT 24" O.C.
TR-SL120
EPDM GASKET
BOTH SIDES 109
110
BATH 2
CLOSET
C. TILE
C. TILE
C. TILE
C. TILE
GYPSUM WALLBD. - PAINT
GYPSUM WALLBD. - PAINT
-
-
-
-
G.W.B.
G.W.B.
8'-0"
8'-0"
TYPE '"X" MOLD RESISTANT G.W.B.
MIAMI INN 2.0.dwg
CONCRETE SLAB 111 BEDROOM 3 C. TILE C. TILE PAINT ON EXIST'G G.W.B. - - G.W.B. 8'-0"

*
SCALE:

*
112 BATH 3 C. TILE C. TILE PAINT ON EXIST'G G.W.B. - - G.W.B. 8'-0" TYPE '"X" MOLD RESISTANT G.W.B.

* *
PB01A
IT487A

*
############
BEDROOM CLOSET
TYPICAL NON-LOAD BEARING FINISH SCHEDULE NOTES
INTERIOR PARTITION DETAIL * DATE:
1. ALL INTERIOR FINISHES SHALL MEET THE FOLLOWING REQUIREMENTS:
(AT FIRST FLOOR)
SCALE: 3/4" = 1'-0" 13_4"
ALL INTERIOR FINISHES SHALL BE CLASS "A" WITH FLAME SPREAD 0-25 AND SMOKE DEVELOPED 0-450.
2. ALL WALLS & CEILING FINISHES TO BE CLASS "A" FINISH (0-25) FLAME.
abril 19, 2022
2304.4.1 SLEEPERS, SILLS AND SOLE PLATES ON A 3. INTERIOR FINISHES SHALL BE CLASS "I" EXCEPT IN CLOSETS.
AS PER MANUFACTURER'S SPECS
CONCRETE OR MASONRY SLAB WHICH IS IN DIRECT * 4. ALL NEW GYPSUM WALLBOARD CEILINGS AND SOFFITS TO BE 5/8" TYPE 'X'.
CONTACT WITH EARTH SHALL BE APPROVED 5. PROVIDE WATER-RESISTANT GYPSUM WALLBOARD IN ALL WET AREAS AND FINISH WITH ENAMEL PAINT DATE: REVISIONS:
NATURALLY DURABLE OR PRESERVATIVE-TREATED 6. CONTRACTOR TO REPAIR, PATCH, AND REPAINT ALL DAMAGED FINISHES AS REQUESTED IN ALL EXISTING REFINISHED AND REMODELED AREAS.
WOOD. 8. ALL EXISTING DOOR FRAMES IN AREAS WHERE NEW WORK IS TO BE DONE, ARE TO RECEIVE NEW PAINT/ STAIN AS SELECTED BY OWNER. 06-07.21 1 AS-BUILT COORDINATION
9. EXISTING AREAS TO BE RETAINED. PATCH AND REPAIR / REPLACE AS REQUIRED TO MATCH EXISTING ADJACENT FINISH.
15. PAINT ON GYPSUM WALLBOARD SHALL BE SPECIFIED BY OWNER.
16. DOORS & FRAMES: PAINTED TO MATCH MACKNIGHT SMOKED FOODS STANDARDS.
S STANDARD PARTITION 3" = 1'-0" H-1 HEAD DETAIL N.T.S.

MISCELLANEOUS DETAILS
PVC 'L' CASING BEAD CONT. @ GYP. BD. END EXISTING WOOD TRUSSES

1X3 P.T. WD. BLOCKING CONT.


2 x 4 WD.
METAL FURRING 1/2" PLYWOOD 2X TRUSS BOTTOM CHORD BLOCKING
CHANNELS TYP CEILING INSULATION 1 x 6 WOOD
CEILING FIRESTOP

ATTIC ACCESS NOTE:


1/2" DRYWALL CEILING
W/ WOOD THREAD DECOR. TRIM 1. ACCESS TO ATTIC SHALL BE 22" x 36" = 5.5 S.FT. 2 x 6 WOOD BACKING
1/2" DRYWALL MOULDING (MIN. OPENING SIZE 5 SQ.FT.)
DRYWALL SCREWS AT TOP OF WALL CABINET
CEILING
FINISH CEILING
1" LONG
1 X 4 W/ 8d COMMON NAILS
2. PROVIDE R-19 INSULATION AND SIDE WEATHER STRIPPED
3. PROVIDE HOLD DOWN DEVICES (EYE AND HOOK SCREWS
SEAL:
2 1/2" FROM ENDS AND 6" C/C AT EACH SIDE OF OPENING WALL CABINET

(1) LAYER 5/8" GYP. BD. FASTENED VERTICALLY W/ 1"


DETAIL ATTIC ACCESS
4. MINIMUM CLEAR HEADROOM SHALL BE PROVIDED ABOVE
ACCESS OPENINGS
SCALE: N.T.S. INTERIOR PARTITION
TYPE S-12 SCREWS @ 12" O.C. MAX. TO 7/8" GALV. 2" X 4" WOOD STUD
AT 16" O.C.
STL. FURRING CHANNELS ATTACHED VERTICALLY TO
CMU @ 24" MAX. TAPE AND SPACKLE JTS.
2 x 4 WOOD BACKING AT
A CEILING ACCESS PANEL DETAIL N.T.S. BOTTOM OF WALL CABINET
AND AT WALL HUNG
PLUMBING FIXTURE

3-5/8" x 25g METAL STUDS 8" C.M.U. WALL


R-5 RIGID INSULATION
AT 16" O.C.
5/8" DRYWALL
5/8" DRYWALL
EXISTING CMU BLOCK WALL
1 x 4 WD. P.T. BACKING
2 x 4 WD. BACKING AT 33-1/2" ABOVE NOTE:
AT 33-1/2" ABOVE FINISH FLOOR A MINIMUM 2 x 4 HORIZONTAL WOOD MEMBER SECURILY
FINISH FLOOR
FASTENED TO NOT LESS THAN 2 SUCH STUDS, SHALL BE
7/8" GALV. STL. FURRING CHANNEL @ BOTTOM OF INSTALLED FOR THE ATTACHMENT OF EACH WALL HUNG
CMU PLUMBING FIXTURE AND WALL CABINET

ACOUSTIC SEALANT CONT. @ JT. COMPLY WITH F.B.C. 2318.1.15.1


2510.5.1.1
2318.1.15.1
TOP OF CONC. DECK
SEE SECTIONS FOR HEIGHT
33-1/2" ABOVE
FINISH FLOOR
33-1/2" ABOVE
FINISH FLOOR
SHEET TITLE:
NOTE: PROVIDE 1 x 4 WD. P.T. BACKING AT 33-1/2" ABOVE
FINISH FLOOR AT WALL HUNG LOCATIONS
SCALE: 3/4" = 1'-0"
XXXXXXX
F FURRING PARTITION AT EXTERIOR WALL 3" = 1'-0" B TYPICAL BACKING DETAIL N.T.S. C WOOD BACKING DETAIL N.T.S.
SHEET No.:

NOTE: AN ASBESTOS REPORT SHALL BE ISSUED AS PART OF THIS PROJECT BY THE OWNER. THE OWNER WILL PROVIDE THE ASBESTOS ABATEMENT IF REQUIRED. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE ASBESTOS REMOVAL AS PART OF THIS PROJECT.
A-4