You are on page 1of 1

MATERIAL TEST CERTIFICATE

Date Tuesday, January 23, 2024 TC No 1PL-000689


Test Location:
Consignee PRIME STAR TECHNOLOGIES CO LTD
Tests Visual, Physical & Galvanizing (Chemical) Test A ONE FENCE ARABIA COMPANY FOR
Project Name NEOM WATER RESERVIOR INDUSTRY

Product GI+TPC ASSEMBLED CHS POST 67.4/1.20/150.0/BOLTED/HDG/CM_20_2_00490 Customer PO No PST/BGL-1123/TFS/ORD Street 114, State Al Dana, District-Jubail, Pin
Code-35514
Lot QTY 15 Nos Inspected Qty 3 Nos

Sr.No Description Required Tolerance Observation Heat No / MTC No Type of Test Standards Compliance

Physical with Measuring As per Approved


1 Length (in mm) 150 ±3 152.4 - PASS
Tape Drawing

Physical With Vernier ASTM A53 & ASTM F


2 Diameter (in mm) 67.4 ± 0.5 67.7 - PASS
Caliper 1083

Physical With
ASTM A53 & ASTM F
3 Thickness (in mm) 1.2 ± 0.5 1.16 - Micrometer / Vernier PASS
1083
Caliper

Physical With Magnetic


4 Zinc Coating Requirement (gm/m2) Min Avg 275 Min Avg 275 324 - ASTM F 1043 PASS
Thickness Gauge

Physical With Cross


5 Adhension Test No Flakes No Flakes No Flakes - ASTM F 1043 PASS
Hatch Cutter

Dry Film Thickness of Physical With Magnetic


6 Min 350 Min 350 420 42015054 EN 13438 PASS
Thermoplastic Powder Coating (in microns) Thickness Gauge

Should pass the Physical With Cross


7 Adhesion of Thermoplastic Powder Coating -- OK 42015054 ISO 2409 PASS
adhesion test Hatch Cutter

Surface should be
8 Visual Check smooth and free from -- OK - Visual As per Customer Req. PASS
irregularities

The above information is based on testing at the factory, Suppliers test certifies and Approved ITP/Standards

Prepared By Verified By
Name: Nikunj Marolya Name: Deepak Pawar
Designation: QA/QC Engineer Designation: Senior Engineer
Signature : Signature :