1 Anchor Design
1.1 Input data

Anchor type and diameter: HIT-RE 500 V4 + HAS-U 8.8 HDG M20
Return period (service life in years): 50
Item number: 2223914 HAS-U 8.8 HDG M20x260 (element) /
2287553 HIT-RE 500 V4 (adhesive)
Gap filling with Hilti Filling Set M20
Effective embedment depth: hef,act = 200.0 mm (hef,limit = - mm)
Material: 8.8
Evaluation Service Report: ETA 20/0541
Issued I Valid: 9/06/2023 | -
Proof: Engineering judgement SOFA BOND - based on ETAG BOND testing
Stand-off installation: eb = 0.0 mm (no stand-off); t = 20.0 mm

Anchor plate
CBFEM
: lx x ly x t = 463.0 mm x 201.0 mm x 20.0 mm;

Profile: Advance UKC, 152 x 152 x 30; (L x W x T x FT) = 157.6 mm x 152.9 mm x 6.5 mm x 9.4 mm
Base material: 2
cracked concrete, C35/45, fc,cube = 45.00 N/mm ; h = 330.0 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting according to EOTA TR 029, 5.2.2.6 present.

CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

1.1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 ULS ENV N = 86.000; Vx = 0.000; Vy = 0.200; no no 153
Mx = 0.000; My = 0.000; Mz = 0.000;

1.2 Load case/Resulting anchor forces

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y y
3 5 7
1 0.065 0.116 0.116 0.001 1
2 0.000 0.113 0.111 0.020 x
3 12.182 0.128 0.128 0.006
Tension
4 10.776 0.122 0.120 0.022 2 4 6 8
5 19.882 0.105 -0.103 0.024 Compression
6 15.902 0.097 -0.090 0.038
7 18.415 0.161 -0.157 -0.036
8 13.162 0.177 -0.126 0.125

resulting tension force in (x/y)=(78.1/-1.0): 90.384 [kN]


resulting compression force in (x/y)=(-39.9/-45.4): 4.631 [kN]

Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

1.3 Tension load (EOTA TR 029, Section 5.2.2)

Load [kN] Capacity [kN] Utilization bN [%] Status


Steel Strength* 19.882 130.667 16 OK
Combined pullout-concrete cone failure** 90.384 61.990 146 not recommended
Concrete Breakout Failure** 90.384 59.281 153 not recommended
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

1.3.1 Steel Strength

NRk,s [kN] gM,s NRd,s [kN] NSd [kN]


196.000 1.500 130.667 19.882

1.3.2 Combined pullout-concrete cone failure


2 0 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,25 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm]
355,220 341,333 16.00 584.2 292.1 55.0
0
yc t Rk,cr [N/mm ]
2
k y g,Np y g,Np
1.061 10.61 2.300 1.068 1.046

ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np


52.4 0.848 0.2 0.999 0.756 1.000
0
NRk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NSd [kN]
133.271 92.985 1.500 61.990 90.384

Group anchor ID
1, 3-8

1.3.3 Concrete Breakout Failure


2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm]
364,906 360,000 300.0 600.0

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


52.4 0.851 0.2 0.999 0.755 1.000
0
k1 NRk,c [kN] gM,c NRd,c [kN] NSd [kN]
7.200 136.610 1.500 59.281 90.384

Group anchor ID
1, 3-8

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

1.4 Shear load (EOTA TR 029, Section 5.2.3)

Load [kN] Capacity [kN] Utilization bV [%] Status


Steel Strength (without lever arm)* 0.177 78.400 1 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 0.200 108.128 1 OK
Concrete edge failure in direction x+** 0.501 14.036 4 OK

* highest loaded anchor **anchor group (relevant anchors)

1.4.1 Steel Strength (without lever arm)

VRk,s [kN] gM,s VRd,s [kN] VSd [kN]


98.000 1.250 78.400 0.177

1.4.2 Pryout Strength (Concrete Breakout Strength controls)


2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k-factor
366,450 360,000 300.0 600.0 2.000

ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N


88.4 0.772 0.0 1.000 0.755 1.000
0
NRk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
136.610 1.500 108.128 0.200

Group anchor ID
1-8

1.4.3 Concrete edge failure in direction x+

lf [mm] dnom [mm] k1 a b


200.0 20.00 1.700 0.191 0.082
2 0 2
c1 [mm] Ac,V [mm ] Ac,V [mm ]
55.0 22,976 13,612

y s,V y h,V aV [°] y a,V ec,V [mm] y ec,V y re,V


0.976 1.000 18.70 1.046 3.3 0.962 1.000
0
VRk,c [kN] gM,c VRd,c [kN] VSd [kN]
12.696 1.500 14.036 0.501

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

1.5 Combined tension and shear loads (EOTA TR 029, Section 5.2.4)

bN bV a Utilization bN,V [%] Status


1.525 0.036 1.000 131 not recommended

(bN + bV) / 1.2 £ 1.0

1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA
TR029, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor
plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.
The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
• The anchor resistances used for this design are ONLY valid if the Hilti Filling Set will be installed on the jobsite as per IFU when the Seismic
washer was selected.
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Characteristic bond resistances depend on short- and long-term temperatures.
• The design method SOFA assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling
the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Filling set) or by other suitable means
• The compliance with current standards (e.g. EN 1993, AS 4100:1998, etc.) is the responsibility of the user
• An SLS-check is not performed for SOFA and has to be provided by the user!
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
• The characteristic bond resistances depend on the return period (service life in years): 50

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

1.7 Installation data


2
Anchor plate, steel: S 355; E = 210,000.00 N/mm ; fyk = 355.00 N/mm
2 Anchor type and diameter: HIT-RE 500 V4 + HAS-U 8.8
HDG M20
Profile: Advance UKC, 152 x 152 x 30; (L x W x T x FT) = 157.6 mm x 152.9 Item number: 2223914 HAS-U 8.8 HDG M20x260
mm x 6.5 mm x 9.4 mm (element) / 2287553 HIT-RE 500 V4 (adhesive)
Hole diameter in the fixture: df = 22.0 mm Maximum installation torque: 150 Nm
Plate thickness (input): 20.0 mm Hole diameter in the base material: 22.0 mm
Hole depth in the base material: 200.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 244.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

Gap filling with Hilti Filling Set M20.0 mm


http://download.hilti.biz/data/techlib/help/IFU_Seismic-Filling-Set.pdf

Hilti HAS-U threaded rod with HIT-RE 500 V4 injection mortar with 200 mm embedment h_ef, M20, Hot dip galvanized, Hammer drilled
installation per ETA 20/0541, with annular gaps filled with Hilti Filling set or any suitable gap solutions

1.7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • Dispenser including cassette and mixer
• Properly sized drill bit accessories to blow from the bottom of • Hilti filling set
the hole • Torque wrench
• Proper diameter wire brush

86.5
y
231.5 231.5
5.0 50.0

100.5

3 7
5
1.0
6.0

1
0.5

93.0

x
100.5

4
5.0

2 6
1.0
31.0 9.0

36.0 4.0 91.0 4.0 183.0 10.0 95.0 2.9 37.1

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y Anchor x y c-x c+x c-y c+y
1 -191.5 38.5 - 440.9 184.0 - 5 86.5 44.5 - 162.9 190.0 -
2 -195.5 -59.5 - 444.9 86.0 - 6 96.5 -60.5 - 152.9 85.0 -
3 -96.5 45.5 - 345.9 191.0 - 7 191.5 50.5 - 57.9 196.0 -
4 -100.5 -54.5 - 349.9 91.0 - 8 194.4 -69.5 - 55.0 76.0 -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

2 Anchor plate design

2.1 Input data


Anchor plate: Shape: Rectangular
lx x ly x t = 463.0 mm x 201.0 mm x 20.0 mm
Calculation: CBFEM
Material: S 355; Fy = 355.00 N/mm²; εlim = 5.00%
Anchor type and size: HIT-RE 500 V4 + HAS-U 8.8 HDG M20, hef = 200.0 mm
Anchor stiffness: The anchor is modeled considering stiffness values determined from load displacement curves tested in an
independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method: EN-based design using component-based FEM
Stand-off installation: eb = 0.0 mm (No stand-off); t = 20.0 mm
Profile: 152 x 152 x 30; (L x W x T x FT) = 157.6 mm x 152.9 mm x 6.5 mm x 9.4 mm
Material: S 355; Fy = 355.00 N/mm²; εlim = 5.00%
Eccentricity x: 86.5 mm
Eccentricity y: 0.5 mm
Base material: Cracked concrete; C35/45; fc,cyl = 35.00 N/mm²; h = 330.0 mm; E = 34,000.00 N/mm²; G = 14,166.67
N/mm²; v = 0.20
Welds (profile to anchor plate): Type of redistribution: Plastic
Material: S 355
Stiffeners: Material: S 355; Fy = 355.00 N/mm²; εlim = 5.00%
Welds (stiffeners to profile/anchor Type of redistribution: Plastic
plate): Material: S 355
Mesh size: Number of elements on edge: 8
Min. size of element: 10.0 mm
Max. size of element: 50.0 mm

2.1.1 Custom stiffeners


Profile side Position [mm] Height [mm] Thickness [mm] Width [mm] Horizontal edge Vertical edge
length [mm] length [mm]
Stiffener 1 Flange - outer 76.5 125.0 10.0 140.0 50.0 50.0
(F1)
Stiffener 2 Flange - outer 76.5 125.0 10.0 65.0 50.0 50.0
(F7)

2.2 Summary
Description Profile Stiffeners Anchor plate Welds [%]
sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] Hole bearing
[%]
1 ULS ENV 53.74 0.00 47.50 0.00 39.74 0.00 1 18
2.3 Anchor plate classification
Results below are displayed for the decisive load combinations: ULS ENV
Anchor tension forces Equivalent rigid anchor plate (CBFEM) Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 3.047 kN 0.065 kN
Anchor 2 0.000 kN 0.000 kN
Anchor 3 12.674 kN 12.182 kN
Anchor 4 8.689 kN 10.776 kN
Anchor 5 16.115 kN 19.882 kN
Anchor 6 14.552 kN 15.902 kN
Anchor 7 18.197 kN 18.415 kN
Anchor 8 16.250 kN 13.162 kN

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can
be applied.

2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for
critical cross sections, which should be performed outside of PROFIS Engineering.

2.4.1 Equivalent stress and plastic strain


Limit state criteria as per EN1993-1-5 Annex C.8, (1) 2.

Results
Part Load Material sEd [N/mm²] ePl [%] fy [N/mm²] gM0 fy/gM0 elim [%] Status
combination [N/mm²]
Plate ULS ENV S 355 39.74 0.00 355.00 1.00 355.00 5.00 OK
Profile ULS ENV S 355 53.74 0.00 355.00 1.00 355.00 5.00 OK
Profile ULS ENV S 355 34.00 0.00 355.00 1.00 355.00 5.00 OK
Profile ULS ENV S 355 38.15 0.00 355.00 1.00 355.00 5.00 OK
Stiffener0 ULS ENV S 355 47.50 0.00 355.00 1.00 355.00 5.00 OK
Stiffener1 ULS ENV S 355 27.35 0.00 355.00 1.00 355.00 5.00 OK

2.4.1.1 Equivalent stress


Results below are displayed for the decisive load combination: 1 - ULS ENV

355.00 N/mm²

0.00 N/mm²

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

2.4.1.2 Plastic strain


Results below are displayed for the decisive load combination: 1 - ULS ENV

5.00%

0.00%
2.4.2 Hole bearing
Decisive load combination: 1 - ULS ENV
Plate hole bearing resistance, EN1993-1 - 8 section 3.6.1:

Equations

k1 ab fu d t
Fb,Rd =
gM2
VEd
Utilization =
Fb,Rd

Variables
k1 ab fu [N/mm²] d [mm] t [mm] gM2
Anchor 1 2.50 0.61 490.00 20.0 20.0 1.25
Anchor 2 2.50 0.55 490.00 20.0 20.0 1.25
Anchor 3 2.50 1.00 490.00 20.0 20.0 1.25
Anchor 4 2.50 1.00 490.00 20.0 20.0 1.25
Anchor 5 2.50 1.00 490.00 20.0 20.0 1.25
Anchor 6 2.50 1.00 490.00 20.0 20.0 1.25
Anchor 7 2.50 0.62 490.00 20.0 20.0 1.25
Anchor 8 2.50 0.67 490.00 20.0 20.0 1.25

Results
VEd [kN] Fb,Rd [kN] Utilization [%] Status
Anchor 1 0.116 237.590 1 OK
Anchor 2 0.113 217.382 1 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

VEd [kN] Fb,Rd [kN] Utilization [%] Status


Anchor 3 0.128 392.000 1 OK
Anchor 4 0.122 392.000 1 OK
Anchor 5 0.106 392.000 1 OK
Anchor 6 0.098 392.000 1 OK
Anchor 7 0.161 243.769 1 OK
Anchor 8 0.177 261.617 1 OK

2.5 Welds
Profiles are modeled without taking the corner radius into account. Special rules for welding (e.g. for cold-formed profiles ...) are not taken into
account by the software.

2.5.1 Anchor plate to profile


Decisive load combination: 1 - ULS ENV
Weld design, EN1993-1-8 section 4.5.3.2
Minimum web weld thickness (amin): 4.0 mm

Minimum flange weld thickness (amin): 4.0 mm

Equations

sw,Ed = (s┴2 + 3 (t┴2 + t||2))0.5


fu
sw,Rd =
bw gM2
fu
s┴,Rd = 0.9
gM2
sw,Ed |s┴|
Utilization = max ( ; )
sw,Rd s┴,Rd
Variables
Weld bw fu [N/mm²] gM2
Web 0.90 490.00 1.25
Flange 0.90 490.00 1.25

Edge a [mm] L [mm] ePl [%] s┴ [N/mm²] t|| [N/mm²] t┴ [N/mm²]


Member 1-bfl 1 6.0 152.9 0.00 29.40 -19.26 32.23
Member 1-bfl 6.0 152.9 0.00 33.34 23.22 -30.50
Member 1-tfl 1 6.0 152.9 0.00 10.58 -5.44 13.62
Member 1-tfl 6.0 152.9 0.00 16.47 9.06 -13.43
Member 1-w 1 6.0 148.2 0.00 12.36 12.14 11.88
Member 1-w 6.0 148.2 0.00 11.74 -14.25 -12.21

Results
Edge sw,Ed [N/mm²] sw,Rd [N/mm²] s┴,Rd [N/mm²] Utilization [%] Utilizationc [%] Status
Member 1-bfl 1 71.37 435.56 352.80 17 7 OK
Member 1-bfl 74.30 435.56 352.80 18 8 OK
Member 1-tfl 1 27.52 435.56 352.80 7 3 OK
Member 1-tfl 32.54 435.56 352.80 8 4 OK
Member 1-w 1 31.91 435.56 352.80 8 4 OK
Member 1-w 34.56 435.56 352.80 8 4 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

2.5.2 Stiffeners to profile/anchor plate


Decisive load combination: 1 - ULS ENV
Weld design, EN1993-1-8 section 4.5.3.2
Minimum stiffener to profile flange weld thickness (amin): 3.0 mm

Minimum stiffener to plate weld thickness (amin): 4.0 mm

Equations

sw,Ed = (s┴2 + 3 (t┴2 + t||2))0.5


fu
sw,Rd =
bw gM2
fu
s┴,Rd = 0.9
gM2
sw,Ed |s┴|
Utilization = max ( ; )
sw,Rd s┴,Rd
Variables
bw fu [N/mm²] gM2
0.90 490.00 1.25

Edge a [mm] L [mm] ePl [%] s┴ [N/mm²] t|| [N/mm²] t┴ [N/mm²]


Stiffener0 (Anchor 6.0 140.0 0.00 8.67 -15.79 8.12
plate)
Stiffener0 (Anchor 6.0 140.0 0.00 -1.56 15.97 1.69
plate) 1
Stiffener1 (Anchor 6.0 65.0 0.00 8.59 -8.41 9.51
plate)
Stiffener1 (Anchor 6.0 65.0 0.00 11.08 12.15 -10.16
plate) 1
Stiffener0 (Member 6.0 125.0 0.00 22.87 25.68 22.78
1-tfl 1)
Stiffener0 (Member 6.0 125.0 0.00 22.90 -25.55 -22.99
1-tfl 1) 1
Stiffener1 (Member 6.0 125.0 0.00 6.98 16.06 6.96
1-bfl 1)
Stiffener1 (Member 6.0 125.0 0.00 6.82 -15.83 -6.83
1-bfl 1) 1

Results
Edge sw,Ed [N/mm²] sw,Rd [N/mm²] s┴,Rd [N/mm²] Utilization [%] Utilizationc [%] Status
Stiffener0 (Anchor 31.94 435.56 352.80 8 5 OK
plate)
Stiffener0 (Anchor 27.85 435.56 352.80 7 5 OK
plate) 1
Stiffener1 (Anchor 23.61 435.56 352.80 6 4 OK
plate)
Stiffener1 (Anchor 29.59 435.56 352.80 7 5 OK
plate) 1
Stiffener0 (Member 63.71 435.56 352.80 15 5 OK
1-tfl 1)
Stiffener0 (Member 63.78 435.56 352.80 15 5 OK
1-tfl 1) 1
Stiffener1 (Member 31.12 435.56 352.80 8 3 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

Edge sw,Ed [N/mm²] sw,Rd [N/mm²] s┴,Rd [N/mm²] Utilization [%] Utilizationc [%] Status
1-bfl 1)
Stiffener1 (Member 30.63 435.56 352.80 8 3 OK
1-bfl 1) 1

2.6 Concrete
Decisive load combination: 1 - ULS ENV
According to EN1992-1-1 section 6.7(4), the concrete should have sufficient reinforcement to take into account the tensile forces that develop
due to the fixture attachment. The definition of the reinforcement in the concrete is out of scope of PROFIS Engineering.

2.6.1 Compression in concrete under the anchor plate


1.85 N/mm²

0.00 N/mm²

2.6.2 Note: In case no external compression loads are applied to the anchor plate, compressions in concrete under the plate, per
EN1993-1-8 section 6.7 and EN1992-1, are not performed.

2.7 Symbol explanation


a Throat thickness of weld
ab Factor
amin Minimum weld thickness
bw Correlation factor EN 1993-1-8 tab. 4.1
d Nominal diameter of the bolt
elim Limit plastic strain
ePl Plastic strain from CBFEM results
Fb,Rd Plate bearing resistance EN 1993-1-8 tab. 3.4
fu Ultimate strength
fy Yield strength
gM0 Steel safety factor gamma M0
gM2 Steel safety factor gamma M2
k1 Factor for edge distance and bolt spacing perpendicular to the direction of load transfer - EN 1993-1-8 - Table 3.4
L Length of weld
s┴ Perpendicular stress
s┴,Rd Perpendicular stress resistance
sEd Equivalent stress
sw,Ed Equivalent stress
sw,Rd Equivalent stress resistance
t Thickness of the anchor plate
t┴ Shear stress perpendicular to weld axis
t|| Shear stress parallel to weld axis
Utilizationc Weld capacity utilization
VEd Anchor shear force

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

12
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

2.8 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability
and adequacy for your specific jurisdiction and project requirements.
● The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

13
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

3 Summary of results
Design of the anchor plate, anchor, welds and other elements are based on CBFEM (component based finite element method) and Eurocode
regulations.
Load combination Max. utilization Status
Anchors ULS ENV 153% NOT OK
Anchor plate ULS ENV 12% OK
Welds ULS ENV 18% OK
Stiffeners ULS ENV 14% OK
Profile ULS ENV 16% OK

Fastening does not meet the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

14
Hilti PROFIS Engineering 3.0.88

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 15
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - May 25, 2023 Date: 27/10/2023
Fastening point:

4 Remarks; Your Cooperation Duties


● Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,
formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc.,
that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be
conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based
essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the
relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and
cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility.
The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and
the relevance of the results or suitability for a specific application.
● You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you
do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the
Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery
of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

15

You might also like