Professional Documents
Culture Documents
Isolated Foundation - 6
Isolated Foundation - 6
Isolated Footing 56
1m
0.5 m
Elevation
X 1.5 m
0.5 m
0.7 m
3m
1.5 m
3m
Plan
Input Values
Footing Geometry
Column Dimensions
Pedestal
Include Pedestal : No
Pedestal Shape : N/A
Design Parameters
Soil Properties
Global Settings
Top Reinforcement Option : Calculate only when foundation is subjected to uplift forces
Concrete Design Option : Net Pressure(Gross Pressure - Self Weight Pressure)
Top Reinforcement Factor : 1.00
------------------------------------------------------
Design Calculations
Typesetting math: 65%
Load Combinations
Moments are about the center of Column / Pedestal (does not include moments caused by lateral loads)
For the loads shown in this table, the sign convention is the same as that for JOINT LOADS in STAAD.Pro when global Y is the vertical axis.
2
Area from initial length and width, Ao = Lo X W o = 9.00 m
Note: Amin is an initial estimation considering self-weight, axial load and moment against factored bearing capacity.
Typesetting math: 65%
If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero and the pressure
will be redistributed to remaining corners.
Stability Check
Sliding Force
.
Load
Along X- Along Z- Required About X- About Z- Required
Case Resultant
Direction Direction FOS Direction Direction FOS
No.
101 33.90 13.76 12.75 1.50 21.10 155.04 1.50
102 44.07 9.66 9.44 1.50 15.57 226.18 1.50
103 44.07 9.66 9.44 1.50 15.57 226.18 1.50
104 35.52 12.86 12.09 1.50 20.27 163.86 1.50
105 42.66 10.06 9.79 1.50 16.29 213.58 1.50
106 42.66 10.06 9.79 1.50 16.29 213.58 1.50
107 18.76 11.69 9.92 1.50 18.83 56.42 1.50
108 24.03 12.75 11.27 1.50 20.04 81.54 1.50
109 107.37 11.88 11.81 1.50 19.23 300.42 1.50
110 121.35 12.93 12.86 1.50 20.39 269.78 1.50
111 29.25 6.83 6.65 1.50 9.96 109.82 1.50
112 33.44 9.06 8.75 1.50 12.93 142.55 1.50
113 25.93 2342.44 25.93 1.50 198.44 98.09 1.50
114 30.64 61.06 27.39 1.50 104.66 130.20 1.50
115 3.16 12.59 3.06 1.50 18.82 6.93 1.50
116 3.65 14.88 3.55 1.50 23.55 7.18 1.50
117 76.27 3.07 3.06 1.50 4.17 1593.90 1.50
118 20.44 4.66 4.55 1.50 5.85 75.48 1.50
119 25.69 9.24 8.70 1.50 15.31 83.15 1.50
120 31.79 9.70 9.28 1.50 15.88 117.33 1.50
121 98.23 9.31 9.27 1.50 15.47 579.59 1.50
122 105.73 9.76 9.72 1.50 16.01 499.45 1.50
123 37.74 6.76 6.65 1.50 10.39 155.85 1.50
124 42.07 8.06 7.92 1.50 12.34 197.08 1.50
125 34.22 18.88 16.53 1.50 36.30 141.16 1.50
126 39.20 16.03 14.83 1.50 27.40 182.07 1.50
127 4.59 9.72 4.15 1.50 15.46 10.20 1.50
128 5.61 10.45 4.94 1.50 17.23 10.84 1.50
129 79.97 3.69 3.68 1.50 5.20 1277.96 1.50
130 27.83 11.32 10.49 1.50 12.27 110.18 1.50
131 16.71 12.33 9.92 1.50 20.41 45.70 1.50
132 23.34 14.08 12.06 1.50 22.46 71.92 1.50
133 249.03 12.65 12.64 1.50 21.12 115.33 1.50
134 197.99 14.40 14.36 1.50 23.11 110.98 1.50
Load
Along X- Along Z- Required About X- About Z- Required
Case Resultant
Direction Direction FOS Direction Direction FOS
No.
136 38.30 8.57 8.36 1.50 11.94 156.50 1.50
137 25.99 23.24 17.33 1.50 27.92 91.08 1.50
138 33.39 54.97 28.54 1.50 74.12 136.39 1.50
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction
Typesetting math: 65% 247 113.3091 116.7334 179.7177 176.2935 472.0000 9.00
Actual Area in Contact for all ultimate load cases exceeds the minimum required. Hence Safe
Maximum Corner Pressure from all ultimate load cases is less than the allowable. Hence Safe
Shear Calculation
X 1.5 m
Z
0.205 m
1.5 m
Plan
Total Footing Depth, D = 0.50m
Calculated Effective Depth, d = D - Ccover - 1 * db = 0.41 m
For rectangular column, = Bcol / Dcol = 1.40
0.74 m
Z
1.5 m
0.74 m
Plan
From ACI Cl. 22.5.5.1, Vc = = 1171.16 kN
Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the X axis.
X 1.5 m
0.84 m 0.84 m
1.5 m
Plan
From ACI Cl. 22.5.5.1, Vc = = 1171.16 kN
Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the Z axis.
21 - 13 mm
Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required.
The strength values of steel and concrete used in the formulae are in Mpa
13 mm @ 140mm o.c.
Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax
Total reinforcement area, As_total = Nbar X (Area of one bar) = 2708.99 mm2
d= D - Ccover - 0.5 X (dia. of = 0.41 m
one bar)
From ACI Cl. 25.2.1, minimum req'd clear distance between bars
Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 80.00mm
Provided Steel Area / Required Steel Area = 1.00
Calculate the flexural reinforcement for Mz. Find the area of steel required
The strength values of steel and concrete used in the formulae are in ksi
mm @ o.c.
22 - 13 mm
Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required.
The strength values of steel and concrete used in the formulae are in Mpa
13 mm @ 135mm o.c.
Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax
Total reinforcement area, As_total = Nbar X (Area of one bar) = 2837.99 mm2
d= D - Ccover - 1.5 X (dia. of 0.41 m
=
one bar)
Reinforcement ratio, ρ = As_totald × bw = 0.00233
From ACI Cl. 25.2.1, minimum req'd clear distance between bars
Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 80.00mm
Provided Steel Area / Required Steel Area = 1.00
Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.
As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth and surcharge
only, top reinforcement value for all pure uplift load cases will be the same.
Calculate the flexural reinforcement for Mx. Find the area of steel required
The strength values of steel and concrete used in the formulae are in ksi
13 mm @ 140mm o.c.
Along Z on Bottom
13 mm 22 62.70 62.33
Face
Along X on Bottom
13 mm 21 59.85 59.50
Face
Along Z on Top
13 mm 21 59.85 59.50
Face
Along X on Top
13 mm 21 59.85 59.50
Face
Concrete
3
- Length (m) Width (m) Thickness (m) Volume (m )
Formwork
Footing : 6.00 m2
Pedestal : 0.00 m2
Total : 6.00 m2
Soil Excavation
Z Z
21 - 13 mm
21 - 13 mm
Typesetting math: 65%
3m
0.5 m
28-04-2024 12:50:49
Plan
1.5 m
Elevation
BOTTOM 21 - 13 mm
TOP 21 - 13 mm
Dimensions (m) Reinforcement
L B D AstX(T) AstZ(T) AstX(B) AstZ(B)
Foundation
1.5 m
3m 3m 0.5 m 21 - 13 mm 21 - 13 mm 22 - 13 mm 21 - 13 mm
l b h Main Reinforcement Trans Reinforcement
TOP 21 - 13 mm Pedestal
N/A N/A N/A N/A N/A
BOTTOM 22 - 13 mm
Plan