Professional Documents
Culture Documents
Isolated Foundation - 14
Isolated Foundation - 14
Isolated Footing 48
1m
0.5 m
Elevation
X 1.5 m
0.5 m
0.7 m
3m
1.5 m
3m
Plan
Input Values
Footing Geometry
Column Dimensions
Pedestal
Include Pedestal : No
Pedestal Shape : N/A
Design Parameters
Soil Properties
Global Settings
Top Reinforcement Option : Calculate only when foundation is subjected to uplift forces
Concrete Design Option : Net Pressure(Gross Pressure - Self Weight Pressure)
Top Reinforcement Factor : 1.00
------------------------------------------------------
Design Calculations
Typesetting math: 100%
Load Combinations
Moments are about the center of Column / Pedestal (does not include moments caused by lateral loads)
For the loads shown in this table, the sign convention is the same as that for JOINT LOADS in STAAD.Pro when global Y is the vertical axis.
Load
Along X- Along Z- Required About X- About Z- Required
Case Resultant
Direction Direction FOS Direction Direction FOS
No.
136 373.65 55.47 54.87 1.50 32.61 462.41 1.50
137 957.86 10.44 10.44 1.50 15.48 984.94 1.50
138 610.31 10.57 10.57 1.50 18.73 921.78 1.50
139 3.26 93.66 3.25 1.50 206.28 5.56 1.50
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction
Typesetting math: 100% 247 142.8588 139.4551 162.0148 165.4186 472.0000 9.00
Actual Area in Contact for all ultimate load cases exceeds the minimum required. Hence Safe
Maximum Corner Pressure from all ultimate load cases is less than the allowable. Hence Safe
Shear Calculation
X 1.5 m
Z
0.205 m
1.5 m
Plan
Total Footing Depth, D = 0.50m
Calculated Effective Depth, d = D - Ccover - 1 * db = 0.41 m
For rectangular column, = Bcol / Dcol = 1.40
0.74 m
Z
1.5 m
0.74 m
Plan
From ACI Cl. 22.5.5.1, Vc = = 1171.16 kN
Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the X axis.
X 1.5 m
0.84 m 0.84 m
1.5 m
Plan
From ACI Cl. 22.5.5.1, Vc = = 1171.16 kN
Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the Z axis.
21 - 13 mm
Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required.
The strength values of steel and concrete used in the formulae are in Mpa
13 mm @ 140mm o.c.
Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax
Total reinforcement area, As_total = Nbar X (Area of one bar) = 2708.99 mm2
d= D - Ccover - 0.5 X (dia. of = 0.41 m
one bar)
From ACI Cl. 25.2.1, minimum req'd clear distance between bars
Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 80.00mm
Provided Steel Area / Required Steel Area = 1.00
21 - 13 mm
Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required.
The strength values of steel and concrete used in the formulae are in Mpa
13 mm @ 140mm o.c.
Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax
Total reinforcement area, As_total = Nbar X (Area of one bar) = 2708.99 mm2
d= D - Ccover - 1.5 X (dia. of 0.41 m
=
one bar)
From ACI Cl. 25.2.1, minimum req'd clear distance between bars
Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 80.00mm
Provided Steel Area / Required Steel Area = 1.00
Along Z on Bottom
13 mm 21 59.85 59.50
Face
Along X on Bottom
13 mm 21 59.85 59.50
Face
Along Z on Top
N/A N/A N/A N/A
Face
Along X on Top
N/A N/A N/A N/A
Face
3
- Length (m) Width (m) Thickness (m) Volume (m )
Formwork
Footing : 6.00 m2
Pedestal : 0.00 m2
Total : 6.00 m2
Soil Excavation
3m
0.5 m
28-04-2024 12:50:21
Plan
1.5 m
Elevation
BOTTOM 21 - 13 mm
Dimensions (m) Reinforcement
TOP N/A
L B D AstX(T) AstZ(T) AstX(B) AstZ(B)
Foundation
1.5 m