Professional Documents
Culture Documents
Sažetak Predavanja 09
Cilj
g(at) 1 a h(at) 1
K 0.9 K 0.9
0.8 0.8
0.7 0.7
0.6 0.6
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
at at
Slika 10.1: Težinska funkcija PT1 -sustava Slika 10.2: Prijelazna funkcija PT1 -sustava
Automatsko upravljanje :: Predavanje 10 - Polovi, nule i vremenski odzivi
c 2016 Perić,Vukić,Baotić,Vašak&Mišković 5 / 61
Sustavi prvog reda Sustavi prvog reda s nulom u lijevoj poluravnin
U2 (s) 1 + Ts as+b
G(s) = = K1 = K1 , (10-4)
U1 (s) 1 + αTs bs+a
α 1
0 t
T
α−1
α2 T 0 α t
T
Slika 10.4: Težinska funkcija sustava Slika 10.5: Prijelazna funkcija sustava
1+Ts
G(s) = 1+αTs uz 0 < α < 1 1+Ts
G(s) = 1+αTs uz 0 < α < 1
• (b) α > 1
• Prijenosna funkcija ima oblik (10-4), ali ju zapisujemo na način
1 1 − α1
G(s) = + (10-7)
α 1 + αTs
• Fazna karakteristika sklopa (prijenosne funkcije) ima fazno kašnjenje (o
_
primjeni elementa s faznim kašnjenjem bit će takoder riječi u
narednim predavanjima)
• Prema (10-7) ovaj se sustav sastoji od paralelnog spoja P-člana
pojačanja α1 < 1 i PT1 -člana (u cjelini: PPT1 -član)
• (b) α > 1
• Analitički izrazi za težinsku i prijelaznu funkciju isti su kao i za slučaj s
_
faznim prethodenjem, razlika u odzivima prikazanim na Slici 10.6 i
Slici 10.7 proizlazi iz razlike u iznosu parametra α:
1 − t
g(t) = α1 δ(t) + 1 − α1 αT e αT , t ≥ 0
1
t (10-8)
h(t) = 1 + α − 1 e − αT
, t ≥0
t t
g h T
T
1
1
α
α−1 1
α2 T α
α t 0 α t
0
T T
Slika 10.6: Težinska funkcija sustava Slika 10.7: Prijelazna funkcija sustava
1+Ts
1+Ts
G(s) = 1+αTs uz α > 1 G(s) = 1+αTs uz α > 1
1 + jωT
G(jω) =
1 + αjωT
Primjer 10.2: Sustav drugog reda bez nula (PT2 -član) (2)
g(t) h(t)
0.5 1
0.9
0.4 0.8
0.7
0.3 0.6
0.5
0.2 0.4
0.3
0.1 0.2
0.1
0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
t [s] t [s]
Slika 10.8: Težinska funkcija sustava Slika 10.9: Prijelazna funkcija sustava
2
2
prijenosne funkcije G(s) = (s+1)(s+2) prijenosne funkcije G(s) = (s+1)(s+2)
g(t) h(t)
5
1.2
4 1
0.8
3
0.6
2
0.4
1
0.2
2 3 4 5
0 1 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
t [s] t [s]
Slika 10.10: Težinska funkcija sustava Slika 10.11: Prijelazna funkcija sustava
s+ 1 s+ 1
prijenosne funkcije G(s) = 4 (s+1)(s+2)
2 prijenosne funkcije G(s) = 4 (s+1)(s+2)
2
• Opći oblik prijenosne funkcije sustava drugog reda bez nula ima
oblik (ponavljanje s Predavanja 09):
K
G(s) = 1 2 2ζ
(10-9)
ωn2
s + ωn s +1
gdje je:
ωn – prirodna frekvencija neprigušenih oscilacija [s−1 ]
ζ – relativni koeficijent prigušenja
K – statičko pojačanje sustava
• Kada je |ζ| < 1, polovi sustava predstavljaju konjugirano-kompleksni
par, a odziv sustava posjeduje harmoničke komponente
• Oscilatoran PT2 -sustav nosi oznaku PT2 S (dodatno slovo “S” u oznaci
potječe od njem. Schwingungen – oscilacije)
-0.5
-1
ω nt
Im( s )
1
1 ωn h (ω n t )
0.8
ζ=1 0.5
1 Re( s )
ωn 0.6
ζ>1 1
1
ζ =5
-10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 Re( s )
-1
ωn
ζ =2 -2
-3
ω nt
Im( s )
h (ω n t )
2
1 ωn 1.8
1.6
-1 0.2 ω nt
0 5 10
Im( s )
ωn h (ω n t )
1
−1 < ζ < 0 1
0.5 Re( s )
ωn
-1 -0.5 0 0.5 1
-0.5 ωnt
-1
ζ = −0.1
• Odavde slijedi
dh(t) ωn
g(t) = = p e−σt sin(ωd t) (10-13)
dt 1 − ζ2
Automatsko upravljanje :: Predavanje 10 - Polovi, nule i vremenski odzivi
c 2016 Perić,Vukić,Baotić,Vašak&Mišković 23 / 61
Sustavi drugog reda Analiza sustava drugog reda bez nula
• Granični slučaj ζ = 1:
h(t) = 1 − (1 + ωn t)e−ωn t ,
(10-15)
g(t) = ωn2 te−ωn t ,
ω nt
1
Td = (10-16)
ζωn
1
G(s) =
(1 + T1 s)(1 + T2 s)
• Prijelazna funkcija za ζ > 1 ima oblik:
p √ p √
ζ + ζ 2 − 1 −ωn ζ+ ζ 2 −1 t ζ − ζ 2 − 1 −ωn ζ− ζ 2 −1 t
h(t) = 1 − p e + p e
2 ζ2 − 1 2 ζ2 − 1
(10-17)
• ζ < 0 – polovi se nalaze u desnoj poluravnini pa je sustav nestabilan
vladanje sustava
• Ova prijenosna funkcija zadovoljavajuće dobro nadomješta i
prijenosne funkcije viših redova kod kojih je:
• jedan par polova dominantan
• ostali polovi relativno daleko od jω-osi (nedominantni polovi)
• U praksi je ovo čest slučaj!
σ
sp,2
100% 2ε
90%
W
50%
10%
0%
t50 tu tm tε t
tz ta
tr
dh(t) kπ
=0 → t = p (10-19)
dt ωn 1 − ζ 2
• Za k = 1 dobije se
t = tm = √π
ωn 1−ζ 2
− √ζπ
(10-20)
h(tm ) = 1 + e 1−ζ 2
80
60
40
20
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 ζ
1.8
tr ≈ (10-23)
ωn
Vrijeme ustaljivanja tε
_
• Vrijeme ustaljivanja (smirivanja) tε (tε =t ˆ s ) kojim je odredeno
ˆ s =T
trajanje prijelaznog procesa nakon kojega hr (t) odstupa manje od
zadanog iznosa ε (npr. ε = 1%, što odgovara vremenu ustaljenja
t1% )
• Za vrijeme ustaljivanja vrijedi izraz:
4.6
t1% ≈ (10-25)
ζωn
100%
bez
regulatora
s regulatorom
tε
σm
2ε
0 t
tm = √π
ωn 1−ζ 2
4.6
t1% = ζωn
− √ πζ
σm [%] = 100e 1−ζ 2
jω
jω
Dopušteno
Zahtjev s obzirom na vrijeme područje ωn,0
σ
porasta tr (ta ; ta,50 ) polova
jω
Dopušteno
Zahtjev s obzirom na područje
polova σ
vrijeme ustaljivanja tε σ0
tε ≤ tε,max → σ > σ0 = f −1 (tε,max )
000000000000
000000000000
000000000000
jω
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
Dopušteno
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
područje 000000000000
000000000000
000000000000
polova
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
σ
000000000000
na raspored polova
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
GR (s) = KR ,
TI s
Kp
Gp (s) = Slika 10.20: Blokovski prikaz zatvorenog
(1 + T1 s)(1 + T2 s)
regulacijskog kruga
1 1 TI
KR = ,
4ζ 2 Kp T2
tj. pojačanje regulatora ovisi o relativnom koeficijentu prigušenja,
pa se npr. za parametre procesa Kp = 10, T1 = 1 s, T2 = 0.1 s i za
odabrani ζ = 0.58 dobiva TI = 1s, KR = 0.74 i, posljedično,
ωn = 8.6 s−1
Automatsko upravljanje :: Predavanje 10 - Polovi, nule i vremenski odzivi
c 2016 Perić,Vukić,Baotić,Vašak&Mišković 44 / 61
_
Prikaz zahtjeva na sustav upravljanja u s-ravnini Odredivanje ζ i ωn zatvorenog regulacijskog
kapacitet C = 13 µF
Slika 10.21: Izvedba regulatora sklopom
s operacijskim pojačalom
ωn s + βωn
G(s) = (10-26)
β s 2 + 2ζωn s + ωn2
pa pripadne težinska i prijelazna funkcija glase (|ζ| < 1):
p 1− 1 p
g(t) = ωn e−ζωn t β1 cos(ωn 1 − ζ 2 t) + √ β 2 sin(ωn 1 − ζ 2 t) , t ≥ 0
1−ζ
−ζωn t
p ζ− β1 p
h(t) = 1 − e cos(ωn 1 − ζ t) + √ 2 sin(ωn 1 − ζ 2 t) , t ≥ 0
2
1−ζ
β = 0.5
3.5
β = 0.25 2
3 β =1
2.5
β = 0.5 1.5 β = 5, 8, 10
2
1.5 β =1 1
1
0.5
0.5 β = 5, 8, 10
5
0 10 ωn t 0 5 10 ω nt
-0.5
-1
Slika 10.22: Težinska funkcija za razne Slika 10.23: Prijelazna funkcija za razne
vrijednosti β vrijednosti β
Automatsko upravljanje :: Predavanje 10 - Polovi, nule i vremenski odzivi
c 2016 Perić,Vukić,Baotić,Vašak&Mišković 47 / 61
Kraćenje nula-pol (kompenzacija utjecaja nula na
Kradinamičko
ćenje polavladanje
pobude isustava)
nule sustava
1
Y (s) = G(s)U(s) =
N(s)
• Nula sustava sN1 = −a blokira prijenos signala u(t) = e−at kroz
sustav
• To znači da je za ovakvu pobudu potpuno blokiran dio prisilnog
odziva sustava koji odgovara partikularnom rješenju diferencijalne
jednadžbe sustava
Automatsko upravljanje :: Predavanje 10 - Polovi, nule i vremenski odzivi
c 2016 Perić,Vukić,Baotić,Vašak&Mišković 48 / 61
Kraćenje nula-pol (kompenzacija utjecaja nula na
Kradinamičko
ćenje nula vladanje
i polova prijenosne
sustava) funkcije
2
G1 (s) = •−−◦ g1 (t) = 2e−2t , ∀t ≥ 0
s+2
• Za a = 2 (kraćenje pola sp2 = −2) dobije se:
1
G2 (s) = •−−◦ g2 (t) = e−t , ∀t ≥ 0
s+1
Automatsko upravljanje :: Predavanje 10 - Polovi, nule i vremenski odzivi
c 2016 Perić,Vukić,Baotić,Vašak&Mišković 49 / 61
Kraćenje nula-pol (kompenzacija utjecaja nula na
Kradinamičko
ćenje nula vladanje
i polova prijenosne
sustava) funkcije
Y (s) 2 s+a 2
G(s) = = ↔ ÿ(t) + 3ẏ(t) + 2y(t) = u̇(t) + 2u(t)
U(s) a (s + 1)(s + 2) a
ωn s + βωn
G(s) = ,
β s 2 + 2ζωn s + ωn2
1.5 β = 5, 8, 10
0 5
β = -5, -8, -10
10
ωnt
1
-0.5
β = −1
-1 β = −0.5 0.5
β = −0.25
-1.5 0 5 10 ωnt
Slika 10.25: Prijelazne funkcije za β < 0 Slika 10.26: Prijelazne funkcije za β > 0
1 − Ts (svepropusni član
G(s) =
1 + Ts prvog reda!)
Slika 10.27: RC-mreža
t [s ]
0 5 10
1.5
∆he [ m ] 1
0.5
250
0 podbačaj
200 -0.5
150 -1
-1.5
100 0 0.5 1
50
0
-50
5 10
t [s ]
∆P(s) 1 − Ts
= (10-30)
∆X (s) 1 + 0.5Ts
Otvor
privodnog aparata gdje je:
• ∆P(s) - promjena mehaničke
snage turbine
• ∆X (s) - promjena otvora
privodnog aparata
• T - vremenska konstanta
tromosti vode
Slika 10.30: Turbinsko-generatorski slog s
privodnim aparatom
Automatsko upravljanje :: Predavanje 10 - Polovi, nule i vremenski odzivi
c 2016 Perić,Vukić,Baotić,Vašak&Mišković 59 / 61
Neminimalno-fazni sustavi Primjeri neminimalno-faznih sustava
Zaključak
_
• Izbor mjesta polova u s-ravnini (odredenih parametrima ζ i ωn )
_
odreduje dinamičke pokazatelje kvalitete sustava u vremenskom
području (neposredni pokazatelji
_ kvalitete)
• Dobivene su relacije za odredivanje neposrednih pokazatelja
kvalitete sustava drugog reda bez nula:
1.8 √π
tr = ωn , tm = ,
ωn 1−ζ 2
4.6 − √ πζ
t1% = ζωn , σm [%] = 100e 1−ζ 2