You are on page 1of 4

OILGASLAB TESTING SER\TICES SDN BHD

/CO_. ·o SOGSH-PJ

LOT A 1, �1....\.."'\J,\-1.0H...\.."'\J'S \\r. ..\R.EHOUSE.J.-\L..\..'\J PATAL'-PATAU


87000 \\'IL.AYAH PERSEKL'Tl!A.'\J L-\BUA."'\J.
TEL, 067-410127, FA.�, 067-420127 HP, 012-8050066
email , oilgaslab@hotmail.com

MAGNETIC PARTICLE INSPECTION REPORT


llEl'IJll1' 1\'IJ.: OGI/MT/CE'l'C0/18/085
Client : CETCO ENERGY SERVICES (M) SDN BHD Client P.O. No.
Date Of Inspection 26.06.2019
Location : Cetco Yard, Sg.Keling
Area Inspected hammer wing (full body)

Specification : Magnetizing Current : [1J Alternating Current □ Permanent Magnet

□ D GJ

ASME B31.3:2004 Magnetic Source Magnaflux Y-6 Magnaflux YM-5

[1J API 11.4 Method Dry □ Wet Continuous. F/cence

� Continuous Magnetization, Colour Contrast, Wet Method


Surface/Cleaning : Background (White Contrast Paint) : D Ardrox 8901W [1J Magnaflux WCP-2
GJ By Wire Brush Magnetic Ink: D Ardrox 800/3 [1J Magnaflux ?HF
D Others
Surface Condition : [1J As Welded D As Forged D As Threaded

Item Quantity Description

3"1502 TEE ( W X W X T)

C 1 1 EA Serial No.:
T-31 0K-003-MY

G]

Result of Test : M.P. I was carried- out on the above item and found to be acceptable PASSED
to code at the time of inspection. FAILED

Ins ected B Endorsed B

Name : Khiano Simpul Name:


Position : ASNT Level II Inspector Position : Surveyor

You might also like