You are on page 1of 1

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

500Gallon

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

LOCATION OF WATER TANKS IN ROOF

kn/m2 kn/m2 kn/m2 kn/m2

Floor Finish loads (15cm thk)= Floor Finish loads (10cm thk
3.75 kn/m2 water proof)= 2.5 kn/m2
BAWABT ALEMARAT
False ceiling loads = 0.5kn/m2 4.5 3 False ceiling loads = 0.5kn/m2 3.5 3 ENGINEERING CONSULTANTS

Total = 4.25 = 4.5kn/m2 MEP loads = 0.5 kn/m2


Total = 3.5kn/m2

Floor Finish loads (10cm thk(water Client


Floor Finish loads (7.5cm proof)= 2.5 kn/m2 Project Villa Double Storey
thk)= 2 kn/m2 Drg.Title LOADING PLAN
False ceiling loads = 0.5kn/m2
False ceiling loads = 0.5kn/m2 Area Floortype
MEP loads = 0.5 kn/m2
Total = 3 kn/m2 2.5 3 3.5 3 Case ID. 1227400 Draw. Type. STRC
Total = 3.5kn/m2 Sec No. Com. No.
partition loads taken as line + Block No. Plot No. 111180002
Water tank location mentioned as
loads. As mentioned in design 10 Bldg. No. BLD- Floor No.
10 kn/m2 as live load
report. Date 08-01-2020 Sht. No. S11
Scale 1:80 Job No. 605
G.Manager Architect Drawn by
MOHD MOHSIN

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT