You are on page 1of 2

*** ECONOMICAL DIA STATEMENT ***

Name of Work: Providing Drinking Water Facilities to village in GP Kashlog, Sewra Chandi, Parnoo, Sanghoi, Mango, Navgoan, Darlaghat etc. in Tehsil Arki Distt. Solan (H.P)
DATA : First Stage CALCULATIONS : PIPE RATES

GMS Tube as per 1239:1990 (Part-I)


Length of rising main = 4230.00 m Initial water requirement = 235550.00 lpd = 235.550 klpd Dia Rate
RL of highest discharge point = 793.08 m Initial net water requirement Q1 = 235550.00 lpd = 235.550 klpd 40 mm 427.00
RL of pump shaft level = 985.00 m Intermidiate water requirement = 278670.00 lpd = 278.670 klpd 50 mm 566.70
LWL in sump well = 985.00 m Intermidiate net water requirement Q2 = 278670.00 lpd = 278.670 klpd 65 mm 697.50
Pumping hour at the end of 1st 15 years = 24.00 hrs. Ultimate water requirement = 321720.00 lpd = 321.720 klpd 80 mm 871.80
No.of working pump set providing = 1.00 Nos. Ultimate net water requirement Q3 = 321720.00 lpd = 321.720 klpd 100 mm 1196.20
Construction period = 2.00 years Ist 15 years 2nd 15 years 125 mm 1460.40
Rate of population increase = 1.25 % Discharge at installation = 0.236 mld = 0.279 mld 150 mm 1747.50
Value of 'C' = 100 Discharge at the end of 15 years = 0.279 mld = 0.322 mld 200 mm 2097.00
Cost of pumping unit/Kw = 8713 /- Average discharge during 15 years = 0.257 mld = 0.300 mld 250 mm 2516.30
Energy charges/unit = 3.50 /- Avg. hours of pumping during 15 years = 22.140 hrs. = 22.390 hrs 300 mm 3019.60

MSERW Pipe as per IS/ISO: 3183-2007


interest rate = 8.50 % Average annual energy charges = 28283.850 /- = 28603.230 /- 350 mm 3623.60
Combined efficiency of P/machinary = 60.00 % Pumping rate (design discharge) = 278.67 klpd = 321.72 klpd 400 mm 4348.30
Percentage of stand bye Pump sets = 100.00 % 450 mm 5218.00
Life of pumping machinery = 15.00 years 500 mm 6261.50
Life of rising main = 30.00 years 550 mm 7513.90
Water available from Gravity source = 0.00 lpd 600 mm 9016.70
Persons Student Hospital Dhaba Hotels Pilgrim/F.P. Employee Govt.Res. Water Add for leakage/ Fire Fighting Total Water 650 mm 10820.00
wastage Demand
Requiirement Reqiurement
Water requirement per capita @ 70 10 340 135 135 70 45 135 700 mm 12984.00
Population as per Census of 2011 = 1226 0 0 0 0 0 0 0 750 mm 15580.80
Present population in 2019 = 3283 0 0 0 0 0 0 0 229810.00 0.00 0.00 229810.00 800 mm 18697.00
Initial Pop.after Const.period 2021 = 3365 0 0 0 0 0 0 0 235550.00 0.00 0.00 235550.00 850 mm 22436.40
Intermideate population after 15 yrs. 2036 = 3981 0 0 0 0 0 0 0 278670.00 0.00 0.00 278670.00 900 mm 26923.70
Ultimate population after 30 yrs. 2051 = 4596 0 0 0 0 0 0 0 321720.00 0.00 0.00 321720.00
S.No. Pipe Velocity Residual Static First stage of flow = 0.27867 mld 2nd stage of flow = 0.32172 mld Cost of pipes Total present Econ.
Size Ist 2nd head Head Friction Other Total KW req. Cost of Annual Capatalis- Total Friction Other Total KW req. Cost of Annual Capatalised Total capat. Cost/Rmt Total cost worth of all Dia of
stage stage head losses head i/c 100% pumps energy ed energy Capatalis- head losss head i/c 100% pumps energy energy cost of pump of 4230m investments R/main
flow flow loss standbye Charges charges ed cost loss standbye Charges charges & energy pipe length
(mm) (mps) (mps) (m) (m) (m) (m) (m) (KW) (Ths Rs.) (1000 Rs.) (1000 Rs.) (1000 Rs.) (m) (m) (m) (KW) (1000 Rs.) (1000 Rs.) (1000 Rs.) (1000 Rs.) (Rs.) (1000 Rs.) (1000 Rs.) (mm)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
1) 50 1.643 1.896 3.0 -191.92 471.46 47.15 329.69 35.26 307.22 498.64 4140.86 4448.08 615.15 61.52 487.74 60.22 524.70 861.24 7151.97 2258.01 566.70 2397.14 9103.23 0
2) 65 0.972 1.122 3.0 -191.92 131.37 13.14 -44.41 -4.75 -41.39 -67.17 -557.83 -599.22 171.41 17.14 -0.37 -0.05 -0.44 -0.72 -5.94 -1.88 697.50 2950.43 2349.33 0
3) 80 0.642 0.741 3.0 -191.92 47.79 4.78 -136.35 -14.58 -127.04 -206.19 -1712.24 -1839.28 62.35 6.24 -120.34 -14.86 -129.48 -212.52 -1764.83 -557.19 871.80 3687.71 1291.24 80
4) 100 0.411 0.474 3.0 -191.92 16.12 1.61 -171.19 -18.31 -159.54 -258.94 -2150.29 -2309.83 21.03 2.10 -165.79 -20.47 -178.36 -292.75 -2431.10 -767.54 1196.20 5059.93 1982.56 0
5) 125 0.263 0.303 3.0 -191.92 5.44 0.54 -182.94 -19.56 -170.43 -276.62 -2297.09 -2467.51 7.09 0.71 -181.12 -22.36 -194.82 -319.78 -2655.56 -838.41 1460.40 6177.49 2871.57 0
The Economical dia of pumping main is = 80 mm
*** Classification of Pipe line ***
Name of Work: Providing Drinking Water Facilities to village in GP Kashlog, Sewra Chandi, Parnoo, Sanghoi, Mango, Navgoan, Darlaghat etc. in Tehsil Arki Distt. Solan (H.P)

DATA: First Stage


Max.(design) discharge = 321.72 Kld GMS tube as per IS :1239 - 1990 ( Part - I ) MSERW Pipe IS/ISO:3183-2007 :-
Dia of Pipe line (internal) = 80.00 mm Outer Dia of pipeline = 89.90 mm Outer dia of Pipe = 88.90 mm

RD of End (delivery)Pt. = 4230.00 m Wall thk: (H) = Heavy Medium Grade of pipe = L290 or X42 Yld. Stress = 290.00 Mpa

RL of End (delivery Pt.) = 793.08 m 4.80 mm 4.00 mm Stress = Yld Str. = 66.67 % = 193.34 Mpa

Co-eff.of pipe friction ,'C' = 100 Mill Tolerance = 3.00 % Joint Efficiency, JE = 0.85 Mill Tolerance = 3.00 %
Corrosion allowance (thk) = as given below Joint Efficiency, JE = 0.85 MSERW Pipe IS/ISO:3183-2007 :-
Avr.Pipe thk.(Assumed) = 5.60 mm (for water Hammer effect) Outer Dia of pipeline = 88.90 mm Stress = Yield Stress = 66.67 = 140.01 Mpa
Mod.of elasticity of pipe = 2.10E+10 Kg/m2 Fibre Stress , S = 1/3 x 320 = 106.67 Mpa Grade of pipe = L210 or A Yld. Stress = 210.00 Mpa
Wave velocity, C = 1334.16 m/ sec. Joint Efficiency, JE = 0.85 Mill tolerance = 3.00 %
Corrosion allowance (thk) = 1.50 mm for GMS tube,or MSERW Pipe (IS/ISO:3183-2007) = 1.50 mm % MSERW Pipe (IS/ISO: 3183-2007) = 1.50 mm
< -------------- DATA ------------------ >

(i/c
Wall Thickness i/c

Nominal Working
R.D. Field Test Pr. (Design Pr.) Recommended Pipe
Tl. Length of Pipe line

design of flange

Refer Working Pr.in (15)


Tol. Frictional Losses
Wall thk.(Barlow equ) t

ANSI 16.5B & MS Flange


m Residual head)

Thickness worked out


Pressure for
tolerance & corroson

Water Hammer
=P.D /(2.S.JE)

as per IS: 6392:1971


R.L. of Lower Point

Forged Flange as per


Pipe Line ( name )

provided as per code


allowan.
(1st Pt)

Design Pr. For pipe,


(for losses)

Pipe to be provided

Max Static head

(6 + 7 + 8)
1.5 x (6 +8)

1.5 x (8)
From (1st)

(2nd Pt)

P = Max.
MSERW Pipe

IS:1239 -1990

Wall Thickness
MSERW Pipe
IS/ISO:3183-

( Part-I )
(Part-I)
IS/ISO:3183-2007

(11,12,13)

IS:1239 -1990
2007 Type and Class of Pipe Line
To

L290 or L210 L290 or

3.0
Col.(6+8) L210 or A
X42 or A X42 From RD To RD
(m) (m) (m) (m) (m) (m) (m) (m) (m) (m) (m) (mm) (mm) (mm) (mm) (mm) (mm) (mm) Reqd. Use
1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
1 0 120 985.00 4230.00 62.35 100.75 -188.92 -189.85 -283.38 -25.82 -25.82 -126.57 -0.13 -0.10 -0.07 1.37 1.40 1.43 1.43 5.48 5 5 0 to 120
2 120 240 955.58 4110.00 60.58 100.75 -159.50 -148.38 -239.25 1.83 1.83 -98.92 0.01 0.01 0.00 1.51 1.51 1.50 1.50 5.48 5 5 120 to 240
3 240 360 920.04 3990.00 58.81 100.75 -123.96 -97.72 -185.94 35.60 35.60 -65.15 0.18 0.13 0.10 1.69 1.63 1.60 1.60 5.48 5 5 240 to 360
4 360 480 858.93 3870.00 57.04 100.75 -62.85 -8.71 -94.27 94.94 94.94 -5.81 0.47 0.35 0.26 1.98 1.86 1.77 1.77 5.48 5 5 360 to 480
5 480 600 806.25 3750 55.28 100.75 -10.17 67.66 -15.26 145.85 145.85 45.11 0.72 0.54 0.39 2.24 2.06 1.90 1.90 5.48 5 5 480 to 600
6 600 720 762.54 3630 53.51 100.75 33.54 130.57 50.31 187.79 187.79 87.05 0.93 0.70 0.51 2.46 2.22 2.03 2.03 5.48 11 17 600 to 720
7 720 840 705.96 3510 51.74 100.75 90.12 212.79 135.18 242.60 242.60 141.86 1.20 0.91 0.66 2.74 2.44 2.18 2.18 5.48 17 17 720 to 840
8 840 960 701.28 3390 49.97 100.75 94.80 217.15 142.20 245.52 245.52 144.77 1.22 0.92 0.66 2.76 2.45 2.18 2.18 5.48 17 17 840 to 960
9 960 1080 713.69 3270 48.20 100.75 82.39 195.89 123.59 231.34 231.34 130.59 1.15 0.86 0.63 2.68 2.39 2.15 2.15 5.48 17 17 960 to 1080
10 1080 1200 658.45 3150 46.43 100.75 137.63 276.09 206.45 284.81 284.81 184.06 1.41 1.06 0.77 2.95 2.59 2.29 2.29 5.48 23 28 1080 to 1200
11 1200 1320 602.52 3030 44.66 100.75 193.56 357.33 290.34 338.97 357.33 238.22 1.77 1.33 0.97 3.32 2.87 2.50 2.50 5.48 23 28 1200 to 1320
12 1320 1440 559.24 2910 42.89 100.75 236.84 419.60 355.26 380.48 419.60 279.73 2.08 1.57 1.13 3.64 3.12 2.66 2.66 5.48 28 28 1320 to 1440
13 1440 1560 514.74 2790 41.12 100.75 281.34 483.70 422.01 423.21 483.70 322.46 2.40 1.81 1.31 3.97 3.36 2.85 2.85 5.48 28 28 1440 to 1560
14 1560 1680 482.17 2670 39.36 100.75 313.91 529.90 470.87 454.01 529.90 353.27 2.63 1.98 1.43 4.21 3.54 2.97 2.97 5.48 . . . . . . . . . . . . . . . . . 28 28 1560 to 1680
15 1680 1800 456.76 2550 37.59 100.75 339.32 565.36 508.98 477.65 565.36 376.91 2.80 2.11 1.53 4.38 3.67 3.08 3.08 5.48 . . . . . . . . . . . . . . . . . 28 28 1680 to 1800
16 1800 1920 454.14 2430 35.82 100.75 341.94 566.64 512.91 478.51 566.64 377.76 2.81 2.12 1.53 4.39 3.68 3.08 3.08 5.48 . . . . . . . . . . . . . . . . . 28 28 1800 to 1920
17 1920 2040 460.57 2310 34.05 100.75 335.51 554.34 503.27 470.31 554.34 369.56 2.75 2.07 1.50 4.33 3.63 3.05 3.05 5.48 . . . . . . . . . . . . . . . . . 28 28 1920 to 2040
18 2040 2160 467.55 2190 32.28 100.75 328.53 541.22 492.80 461.56 541.22 360.81 2.68 2.02 1.46 4.26 3.58 3.00 3.00 5.48 . . . . . . . . . . . . . . . . . 28 28 2040 to 2160
19 2160 2280 473.83 2070 30.51 100.75 322.25 529.14 483.38 453.51 529.14 352.76 2.62 1.98 1.43 4.20 3.54 2.97 2.97 5.48 . . . . . . . . . . . . . . . . . 28 28 2160 to 2280
20 2280 2400 480.07 1950 28.74 100.75 316.01 517.13 474.02 445.50 517.13 344.75 2.56 1.93 1.40 4.14 3.49 2.94 2.94 5.48 . . . . . . . . . . . . . . . . . 28 28 2280 to 2400
21 2400 2520 488.76 1830 26.97 100.75 307.32 501.44 460.98 435.04 501.44 334.29 2.49 1.87 1.36 4.06 3.43 2.90 2.90 5.48 . . . . . . . . . . . . . . . . . 28 28 2400 to 2520
22 2520 2640 500.54 1710 25.21 100.75 295.54 481.12 443.31 421.49 481.12 320.75 2.39 1.80 1.30 3.96 3.35 2.84 2.84 5.48 . . . . . . . . . . . . . . . . . 28 28 2520 to 2640
23 2640 2760 535.42 1590 23.44 100.75 260.66 426.15 390.99 384.84 426.15 284.10 2.11 1.59 1.15 3.67 3.14 2.68 2.68 5.48 . . . . . . . . . . . . . . . . . 28 28 2640 to 2760
24 2760 2880 552.14 1470 21.67 100.75 243.94 398.41 365.91 366.35 398.41 265.61 1.98 1.49 1.08 3.54 3.03 2.61 2.61 5.48 . . . . . . . . . . . . . . . . . 28 28 2760 to 2880

25 2880 3000 572.38 1350 19.90 100.75 223.70 365.40 335.55 344.35 365.40 243.60 1.81 1.36 0.99 3.36 2.90 2.52 2.52 5.48 . . . . . . . . . . . . . . . . . 23 28 2880 to 3000

26 3000 3120 590.17 1230 18.13 100.75 205.91 336.06 308.87 324.79 336.06 224.04 1.67 1.26 0.91 3.22 2.80 2.44 2.44 5.48 . . . . . . . . . . . . . . . . . 23 28 3000 to 3120
27 3120 3240 616.994 1110 16.36 100.75 179.09 293.17 268.63 296.19 296.19 195.45 1.47 1.11 0.80 3.01 2.64 2.32 2.32 5.48 . . . . . . . . . . . . . . . . . 23 28 3120 to 3240
28 3240 3360 630.42 990 14.59 100.75 165.66 270.38 248.49 281.00 281.00 180.25 1.39 1.05 0.76 2.93 2.58 2.28 2.28 5.48 . . . . . . . . . . . . . . . . . 23 28 3240 to 3360
29 3360 3480 643.89 870 12.82 100.75 152.19 247.52 228.29 265.76 265.76 165.01 1.32 0.99 0.72 2.86 2.52 2.24 2.24 5.48 . . . . . . . . . . . . . . . . . 23 28 3360 to 3480
30 3480 3600 669.28 750 11.06 100.75 126.80 206.78 190.20 238.60 238.60 137.86 1.18 0.89 0.65 2.72 2.42 2.17 2.17 5.48 . . . . . . . . . . . . . . . . . 17 17 3480 to 3600
31 3600 3720 676.661 630 9.29 100.75 119.42 193.06 179.13 229.45 229.45 128.71 1.14 0.86 0.62 2.67 2.39 2.14 2.14 5.48 . . . . . . . . . . . . . . . . . 17 17 3600 to 3720
32 3720 3840 699.34 510 7.52 100.75 96.74 156.39 145.11 205.00 205.00 104.26 1.02 0.77 0.55 2.55 2.29 2.07 2.07 5.48 . . . . . . . . . . . . . . . . . 17 17 3720 to 3840
33 3840 3960 728.31 390 5.75 100.75 67.77 110.28 101.66 174.27 174.27 73.52 0.86 0.65 0.47 2.39 2.17 1.98 1.98 5.48 . . . . . . . . . . . . . . . . . 11 17 3840 to 3960
34 3960 4080 748.86 270 3.98 100.75 47.22 76.80 70.83 151.95 151.95 51.20 0.75 0.57 0.41 2.27 2.09 1.92 1.92 5.48 . . . . . . . . . . . . . . . . . 5 5 3960 to 4080
35 4080 4200 768.41 150 2.21 100.75 27.67 44.82 41.51 130.63 130.63 29.88 0.65 0.49 0.35 2.17 2.00 1.86 1.86 5.48 . . . . . . . . . . . . . . . . . 5 5 4080 to 4200
36 4200 4230 787.86 30 0.44 100.75 8.22 12.99 12.33 109.41 109.41 8.66 0.54 0.41 0.30 2.06 1.92 1.81 1.81 5.48 . . . . . . . . . . . . . . . . . 5 5 4200 to 4230