STANDARD OPERATING
PROCEDURE
FOR
List of Contents
1. Equipment Description:
Circulating water pumps supply cooling water at the required flow rate
and head to the power plant condenser and the plant auxiliary cooling
water heat exchanger. The circulating water pumps must operate
economically and reliable over the life time of the plant. Total 03 pumps
for single unit.
6. Ensure the oil level in the bearing are normal(Thrust Brg. & motor NDE
side)
7. Ensure temperature and vibration probes are fitted and in working
condition.
8. Ensure air venting of pump and other piping is done
9. Condenser water box drain should be open of both pass A &B
10. Condenser water box vent should be open of both pass A&B
11. CW pump bearing sealing & cooling valve should be open & charged.
12. Fore bay level should be normal.
13. Condenser CW inlet valve & outlet valve of both pass should be opened
5. Start Permissive:
1. CW pump can be started provided following permissive are
available
a. Discharge BFV is 100% closed.
m. The pump set have not completed the limit of (3 cold start or 2Hot
start)
p. Incase other pump not running, discharge butter fly valve of stop
Note-: CW pump “ON” command can be given after all the above condition
is satisfied.
switchgear
operation)
6. Starting Procedure:
1. Confirm from local operator that Pump is running in normal condition
2. Check the discharge pressure, current, bearing temp and vibrations of
system is normal
3. Close all line and Pump air vents after proper venting of the system
4. Check for any oil leakage from the bearing.
5. Check for any water leakages from the pump glands and CW line
6. Record the reading –current, bearing temp. & temp. or vibration
7. Tripping Condition:
8. Stopping Procedure:
1. 100% close command shall be given to pump discharge BFV
2. When BFV is closed up to 80% (Limit switches provided) (Settable at site)
STOP COMMAND shall be given for CW motor.
3. Ensure BFV is 100% close within specified time (30-80 sec adjustable).
References: